Exam Review
Acronyms
GPM= gallons per minute
MGD= million gallons per day
TTHM= total trihalomethane
PSI= pounds per square inch
NTU= Nephelometric Turbidity Unit
mg/L= milligrams per litre or ppm= parts per
million are the same
TON= Threshold Odor Number for odor in the water. Should be conducted at 60 degrees C
System Monitoring
To Ensure
Drinking Water is
safe monitor for:
Bacteria
Turbidity
Chlorine residual
Sample Bottles
Sampling bottle/bag should
be filled just above the fill
line or about one inch from
top.
Bottles need to be sterilized
by the lab & ready for use
Bottles have Sodium
Thiosulfate in them to
neutralize the chlorine
Bacteriological Sampling
Procedures
Should allow sample tap water to
run several minutes or as long as
necessary to clear service line
Results are meaningless if sample
is contaminated
Sample identification cards need
to filled out completely
Red water could indicate bacteria
or an electro-chemical
phenomenon
Bacteriological Sampling Procedures
If sample is OK, this only indicates that water was safe at point of sample.
Coliform is an indicator of bacteria presence, absence of coliform indicates water is safe
Sample should be transported as soon as possible in a cool container with ice pack.
Routine bactis should be taken at the customer’s tap at various points that represent the entire system
Chain of custody forms need to be filled out
completely
Not smooth nosed
Composite Sample
A series of grab samples
taken from the same
sampling point at different
times and mixed together
Grab samples represent
instantaneous conditions at
the time and location the
sample was taken
Nitrates
Fertilizing lawns and
farms can cause elevated
levels of nitrates
Nitrates cause
Methemoglobinemia
known as “blue baby”
syndrome
Nephelometric Turbidity
Unit (NTU)
The method used to measure
the cloudiness of the water.
The higher the NTU, the dirtier
the water, the greater the
possibility of microbiological
contamination.
Turbidity can mask bacteria
The use of light through water
to measure
Particle Counter
The method used to measure
the cloudiness of the water –
the amount of particles and
the size of particles.
The dirtier the water, the
greater the possibility of
microbiological contamination.
Weirs
Measured from the
crest of the weir to
the horizontal water
surface in the weir
stilling basin
Membrane Filter Test
Analyzes coliform
bacteria colonies
Any positive sample
requires repeats
More than one positive
is a quality violation
GWR
TC+ bacterial Samples
Requires Triggered Source Water sample (TSW)
All sources that were in operation at time of +TC sample
You can email DDW on sources not sampled – not running
Test for fecal coliform
GWR continued
5 additional samples if
first Triggered Source
Water sample is Fecal+
2 or more sources
requires you to submit
new sample site plan
Correct significant
deficiencies within 120
days
New Minimum PSI Standards
Water pressure is
measured in psi
Maintain minimum of 20
psi at all times
20 psi during fire flow
30 psi during peak
instantaneous demand
40 psi during peak day
demand
Sanitary Surveys Performed
By
Executive Secretary shall ensure a sanitary survey is conducted at least every 3 years
Division of Drinking Water
DEQ District Engineers
Local Health Departments
Forest Service Engineers
Utah Rural Water Association staff
Consulting Engineers
Others authorized by Executive
Secretary
Aesthetics
Means attractive or appealing.
With respect to water it means taste,
odor, or coloration of the water.
Things that affect this are extreme
hardness or high total dissolved solids
Effects range from bad smell and poor
taste to causing stains on laundry
and/or fixtures
Hydrogen sulfide causes rotten egg
odors
Water Storage Reservoirs
Provides adequate water to the water system during average and peak demands
Provides adequate pressures throughout the water systems
Must be covered to prevent algae and bacterial growth
Reserve storage
Fire protection
Most susceptible to degradation from external sources
Measured as volume
Screen Sizes
#14 mesh for air vents and air vacuum release valve
Air vac vent pipe above the flood line
#4 mesh for overflow and drain lines
#14 mesh = 14 squares per inch
#4 mesh = 4 squares
per inch
#14
#4
Pressure Tanks
Blow off valves should
be able to discharge at
pumping rate
Frequent on & off cycling
of the booster pump
shows lack of air in tank
& is water logged
Blow off
Reservoir Maintenance
Comprehensive inspections and
cleaning inside of tank should be
done every 3 to 5 years or more
frequently
Repair
Disinfect
Take bacti’s
Inspect Vents- for ice, screen
holes, etc.
Long & short life coatings for
tank interiors
Surface Reservoirs
Most significant reason for
turn over is a change in
surface water temperature
and density
Act as pre-sedimentation
basins
Water is most dense at
39.2 deg F, 4 deg C.
Colder water has more
oxygen
SCBA
Self Contained
Breathing Apparatus
Always use when
around gas leaks &
oxygen deficient
areas
Confined Spaces
Reservoir site entry
Sources- where
chemicals are stored
Vehicles- Keep away from manhole
Vaults- Carbon Monoxide (CO) will settle to the floor.
Minimum oxygen level of
19.5%
Chemical Handling
All chemicals should
be stored according
to the manufacturer’s
specs
Chemical compound
has multiple
chemicals such as
calcium carbonate
Tank Maintenance
Cycling of water (movement) to prevent freezing
Cathodic protection to protect from corrosion
Age of the water in the tank attributed to quality problems cause by low demand or short circuiting
Sandblasting is recommended for preparing interior of tank
Should be sampled for possible water quality changes
Disinfection of Reservoirs
Facility disinfected before it is put on line
Disinfected after cleaning, repair, painting
AWWA C652
Full reservoir – 10 mg/l/ 24 hours
6 hour/24 hour
Spraying interior – 200 mg/l – 30 minute detention time
Fill 5 %/ 50 ppm – 6 hours, then fill rest of tank <2 ppm – 24 hours
At least one bacteriological sample (TC-)
Water Distribution Systems
Leaks get worse
Do a water audit to identify water & revenue losses
Leak surveys should be done during low flows
Cracked mains should be replaced
Pressures can be measured at a fire hydrant or pressure regulating station
Distribution system pressures
20 psi at all times for peak instantaneous flows
Minimum Water main size
8 inch with fire hydrants
Unless you have an engineer signature to buy off on it
4 inch without fire hydrants
Distribution Systems
Water mains
10 Feet horizontal distance from sewer main
Water main and sewer mains must cross at least
18” of separation
Water line is on top
Water & sewer not installed in the same trench.
Anaerobic growth develops in water devoid of
oxygen causing odor problems
Hydraulic adequacy determined by pressure measurements throughout system at various times
Looped to prevent dead ends, quality problems, and better flow
Customer Service Connection
Corporation valve (corp stop) for customer service line shut off
¾” most common customer service connection
Thaw service line with hot
water or warm air
Consider flow rate &
pressure for sizing
New Main Installation
Jacking and Boring is the
most common technique
for the construction of a
pipeline under a heavily
traveled highway or
railway without
disrupting the traffic
New Water Mains
Steps taken to put into service
Pressure and leak test
Flush out debris
Keep pipe clean
Disinfect the pipe – AWWA C651
Take a chlorine residual
Flush highly chlorinated water
Bacteriological Samples –
2 samples taken 24 hours apart. Why?
Special conditions
Keep ends of pipe plugged when unmanned
Pressure Testing New Water Main
Should be done at 50%
higher than normal
operating pressure or 150
psi whichever is larger
Duration 4 Hours
New connections installed
under pressure are called
hot taps
Water Mains
Never shut main valve completely
(may cause a back siphon)
Disinfect with tablets or granular @
25 mg/L for 24 hours
Continuous Feed – 10 mg/L after 24
hours
Fill main with water
Flush out debris
Fill with chlorinated water
Backfilling Mains
Notify other utilities or blue stakes before digging
Soil placed equally on both sides half way up of the pipe in layers hand tamped
Pipe should covered by about 12” of soil
“Well Point” used to dewater trenches
Shallow mains more
susceptible to freezing
Thrust Blocking
Thrust Block - a concrete mass cast in place between a fitting and the undisturbed soil at the side or bottom of the pipe trench.
Purpose is to keep fittings from moving & either coming loose or apart from the force of the water pressure in the pipe.
Thrust anchors – used when thrust blocks cannot be used
Restrained fitting – use of clamps or anchor screws on fittings
Tie rods – used on mechanical joint fittings that a located close together
Block should be centered on thrust force
Thrust Blocks
Should be place behind
the foot of the hydrant
at the flow line
Fire Hydrants
Hydrant bury is the distance below the
ground to the main connection.
Because of increased population growth
and scaling of pipes, hydrant flow tests
should be performed periodically & after
major changes to distribution system
Dropping a weighted string down the
barrel of hydrant to check for water is
called “Stringing”
Nozzles are usually 2.5 and 4.5 inches
Painted different colors to show flow
Hydrant Cap Color Codes
Class Color Water Flow (GPM)
AA Light blue 1500 or more
A Green 1000–1499
B Orange 500–999
C Red Less than 500
Fire Hydrants
Flushing hydrants can stir up silt creating water quality problems
Should be tested for flow with a pitot gauge
Flow tests show quantity of
available water
Should be metered by
contractors to account for water use
Dry Barrel Hydrants
Drain hole drains barrel to
protect from freezing
Partially open drain valve would
cause excessive leakage from
drain hole
Must be tested for leakage with
main valve open & caps on
Use a listening device to check
for leaking valve seat
Operating valve located in the
base of the hydrant
Flush Hydrants
Means hydrant is
flush with a wall or
ground
For areas where
post hydrants are
not suitable
Flushing the System
Dead End Systems
Water Quality Issues
Customer Complaints
Be mindful of
environmental concerns
During periods of low
demand
Flushing Procedure
Notify customers thru billing,
newspaper, or electronic
media of times and places
affected or anything affecting
the condition of their water
Explain Intent Of Flushing
Notify Hospitals, Dialysis
Patients, Restaurants,
Laundromats, & Others That
May Be Affected
Flushing The System
When The System
Has Become
Contaminated
Newly Installed Or
Repaired Mainlines
Flushing Hydrants
Helps remove taste &
odor causing deposits
Helps remove
encrustations that may
restrict flow
Helps remove sand,
rust, & biological
materials that cause
water quality problems
FLUSHING PROCEDURE
Try To Avoid Flooding Traffic
Areas
Open Hydrant Fully For 5 To
10 Minutes To Stir Up Deposits
Don’t let nearby areas drop
below 20 psi to avoid negative
pressures
Record Pertinent Data: Odor,
Water Appearance, Times, &
Places, Etc.
Fire Fighters
Fire fighters can create
negative pressures
Dead end systems
would likely have
inadequate flows for
firemen
Valves
All system valves
should be exercised
annually
Purpose is to isolate
sections of the
system
Gate Valves
Most commonly used valve in distribution system
Gate Valve: Isolation only, should be either all the way open or all the way closed
Cavitation (formation & collapse of bubbles) can occur
Fully open has least amount of head loss from other valves
Can be repacked without taking out of service
Globe Valves
Best for flow control
throttling, & pressure
regulating
Butterfly Valves -
Higher resistance to
flow
Operates easily &
quickly
They cost less than
gate valves
Used for flow control
& isolation
Ball & Plug Valves
Sluice Gate & Sleeve Valves
PRV Valves
Pressure
Sustaining/Reducing:
maintain either upstream or
downstream pressures
depending on the position
of the pilot screw.
Need to be maintained
periodically
Help reduce water hammer
Pressure Reducing Valves
Installed in parallel
to handle high & low
flows
Altitude Valve
A good valve to
regulate tank levels
Altitude valve:
opens when system
psi drops below a
certain pressure and
closes when the
reservoir reaches a
predetermined level.
Pump Control Valves
Allow pumps to be
started & stopped
against a closed valve
Best method to control
water hammer
Check Valves
Keep flows going
one direction
Flow must be
directional with
pump discharge
lines, customer
service lines, and
water treatment
plants
Air Release Valves (air-vacs)
Allow air in & out
Should be placed at high points in the system
Need to be screened & protected from flooding
Relief valve outlet 12”
above ground
Water Hammer
Occurs when a valve is
closed quickly or pump
shuts down and causes
the water pressures to
rise and fall rapidly.
Sounds like some
hammering on pipe.
Can damage pipes,
causing them burst.
System Mapping
Accurate mapping
ensures the operators
can locate the valves
and main lines in case
of a main break or leak
pH
pH: expression that
refers to the basic or
acidic conditions of the
water
pH is measured on a
scale from 0 to 14.
Less than 7 is more
acidic, greater than 7 is
more basic or higher
alkalinity 7 is neutral.
pH
pH and alkalinity tests can be performed to assess the corrosiveness of the water
Alkalinity expressed as Calcium Carbonate
Chlorine lowers the pH & chlorine rate may need to be increased
Water Hardness
Caused mainly by salts of calcium and magnesium, such as bicarbonate, carbonate, sulfate, chloride and nitrate.
Causes formation of soap curds
Deposits show chemical instability
Deposits of scale in boilers & fixtures
Damages in some industrial
processes
Objectionable tastes in water
Langlier Saturation Index (LSI)
Measures corrosiveness of water
LSI (Carrier)Indication
-2.0 to less than -0.5: Serious corrosion or aggressive
-0.5 to less than 0: Slightly corrosion but non-scale forming
LSI = 0.0 Balanced but pitting corrosion possible
0.0 to less than 0.5: Slightly scale forming and corrosive
0.5 to less than 2: Scale forming but non corrosive
Corrosive
Electrochemical phenomenon
Measurements:
Langelier index
Positive number: Deposit
Negative number: Corrosive
Metal coupons used to measure corrosiveness of
water – determined by weight loss of coupon
Adjustments can be accomplished by:
Chemicals which increase or decrease the
depositing, or
Sequester the problem with the use of
polyphosphates
pH/Alkalinity adjustment w/Lime, Sequestering &
Chelation
Alkalinity
A measurement of the water’s capacity to neutralize an acid
Alkalinity is determined by titrating to an end point with a pH meter or the use of the methyl orange test
Use sulfuric acid to perform test
Affects the coagulation process
Insoluble calcium carbonate compounds cause build up of scale
Hardness expressed as mg/L in CaCO3, to be considered soft should be 0 to 50 mg/L
Head Loss
Valves, elbows, pipe
characteristics, etc.
contribute to loss of flows
Pipe roughness coefficient
tests to see if friction losses
are increasing
Bursting strength of pipe
refers to pipe’s ability to
withstand internal forces
Head Loss
Friction head loss: caused by valves, bends, pipe roughness, etc.
Friction headloss is in direct proportion to the increase in the velocity of the water flow
Various factors can slow down the velocity of water.
Alkalinity expressed as Calcium Carbonate
FRICTIONAL HEADLOSS
Energy used up by water movement
Two Conditions that affect head loss:
1. Roughness of the pipe
2. Velocity of the water
. Two Conditions that affect Roughness:
1. Age – Condition
2. Type of pipe Materials
C-Factor
Indicates the smoothness pipe material
The higher the C value, the smoother the pipe.
To calculate measure flow, pipe diameter, distance between two pressure gauges, and the friction losses between the gauges.
3 most common types of plastic pipe are PVC, PE, & ABS
PVC least susceptible to corrosion
C value reduced by tuberculation
PVC has higher C- factor
than concrete
Water Loss
Affected by: leaks,
pressures, efficiency of the
meter maintenance,
attention given to leak
reduction & unauthorized use
of water
Some systems 10% of the
water produced
Other systems not until 20%
Consumer Calls
Persons name, address, & phone
What’s the problem: taste, odor, discolor,etc.
When was problem first noticed?
Duration of problem?
Are neighbors having same problems?
Has it resulted in any illness?
Has Local Health Dept. or DDW been notified?
Can they get a sample in a clean glass?
Cross Connections
Determined by the degree of hazard
Cross connection: a connection between a potable and an unapproved source.
Two Types of Backflow:
Backsiphonage: backflow caused by a negative or below atmospheric pressure in a water system.
Backpressure: when users pressure is higher than the system pressure
Water user is responsible to keep contaminants out of the water system
Flush out debris and trapped air in newly installed assemblies
An effective program helps minimize degradation of the water system
Responsible for most waterborne disease outbreaks
Devices and Assemblies
Keep contaminants out
Air Gap: a physical break between to connections. Minimum of 1” or two times the diameter of the pipe & safest method of backflow prevention
Double Check Assembly: Has two independent internally loaded check valves, 2 shut off valves, & 4 test cocks.
Cross Connections
Reduced Pressure Principle Assembly: For High Hazards, has 2 spring loaded check valves, a relief valve, 4 test cocks, and 2 shut off valves. Relief port can’t be submerged & installed 12” above floor
Pressure Vacuum Breaker: internal check valve, an internal loaded air poppet, 2 shut off valves and 2 test cocks. Not designed for back pressure
Cross Connection
Atmospheric Vacuum
Breakers not designed to protect against back pressure
Prior to the installation of any backflow
prevention assembly or device owner should be advised thermal expansion hazards
Wire to Water Efficiency
The combined efficiency of
the pump and the motor
together. Also called the
over all efficiency.
Water HP/Electrical
HPx100%=over all
efficiency
The amount of energy
required to overcome the
inefficiencies of the pump
and motor
Electric Motors
Upon start up an electric motor will develop a torque to turn the pump shaft and impeller
Torque causes motor to draw a high amperage
Amperage drops once the pump is up to speed.
To change rotation on 3 phase, switch any 2 leads
Transformers step down voltage
Circuit breakers protect from circuit overloads
Digital Multimeters
Ohm meters measure
resistance
Volt meters measure voltage
Amp meters measure current
Tachometer would show
pump speed
Setting should be set to next
highest level of what you
measuring
Lightning Arrestor
Becomes a low resistance
conductor to ground when
the line voltage exceeds a
predetermined amount
Used to protect equipment
from lightning strikes.
No device made to protect
against a direct hit.
Power Sources
Primary Sources- Power
Company
Auxiliary Sources-
Diesel, Natural Gas, &
Gasoline Powered
Generators may be
necessary in an
emergency
Meter Sizing Considerations
Pressure at the service connection
Highest fixture in the building being
served
Any back flow prevention device
A 5/8 inch meter should be tested
every 5 to 10 years.
Meter should not have more than
20 psi of head loss.
One inch and smaller meters
shouldn’t exceed 15 psi of head loss
Small Meter Installation
Meter pit located on public property
Meter pit relatively safe from vehicle & snow removal equipment
Riser pipes should be 1 to 2 inches away from meter box walls
Use of meter yoke
Use jumper cable to protect from electrical shock from piping in the home
Meter Accuracy
Measure water flow
Worn meters will cause the meter to under register, allowing the customer to receive more water than they pay for.
Unaccountable water loss is the term used in determining meter accuracy & leakage
Over time a worn meter will cost the water system revenue.
Formula: Meter Accuracy= (Meter,GPM)(100%)/Volume,GPM
Magnetic Meters
Maintenance calibration
should include flow at
zero flow rate
Compound Meters
For low to intermediate
flows
Occasionally high flows
Positive Displacement Meter
Nutating disk:
nutating means
nodding. When the
water flows the disk
rotates.
Oscillating Piston Meter
Displacement type
Water flows into a
chamber and displaces
piston
Oscillating circular
motion moves meter
Higher head loss than
nutating disk
Velocity Meter & Venturi
Mechanical rotors or
propellers are turned by
velocity of water to measure
flow
Venturi meters measure
differential pressure & have
no moving parts.
Venturi meters are best for
providing uninterrupted flow
Velocity Meter
Iron
Consumer complaints
Can cause stains on laundry & fixtures
Formation of iron bacteria that form slick slimes on pipe walls
Taste and odor problems
Reacts with chlorine increasing use
Can be removed thru aeration, flushing & polyphosphates
Mixed with manganese react with dissolved oxygen forming insoluble compounds
Manganese
Iron mixed with
manganese reacts
with dissolved
oxygen forming
insoluble
compounds
Causes black stains
Electrolysis
Decomposition of material by an outside electric current
Electric current caused by movement of water in the line
Cathodic protection installed to prevent corrosion
Magnesium anodes help prevent galvanic corrosion
Galvanic corrosion caused by connecting dissimilar metals
Metal coupons evaluated for weigh loss
Tanks – Cathodic Protection
Anodes
Ground Water
Water passing thru
porous soil is called
percolation
Water bearing
geological formation
is called an aquifer
Wells
Sanitary seal – prevents contamination from entering
Well casing – pipe placed inside well to keep it open
Grout – mixture of cement, water and sand pumped between the casing & the drilling hole (annulus)
Specific capacity is the well yield in GPM per foot of drawdown
Well Maintenance
Water needs to be
pumped to waste
until it clears up
ACCURATE RECORD KEEPING
Shows decreases in flow and pressures
Insures each piece of equipment receives proper attention to prolong its life
Shows when preventive maintenance or repairs were last performed
Reduces liability to operator & improves customer service
Work orders best way to track system maintenance