Loading...
HomeMy WebLinkAboutDERR-2024-005496Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name BIOFIRE DIAGNOSTICS LLC Address 1201 S 4800 W SALT LAKE CITY, UT 84104 Contact BIOFIRE DIAGNOSTICS LLC Phone Email None TANK LOCATION Name BIOMERIEUX 1001 MANUFACTURING BUILDING Address 1201 S 4800 W SALT LAKE CITY, UT 84104 A Operator None Phone None B Operator SAME Phone SAME Facility ID: 4002627 Inspection Date: 03/28/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1 Diesel No None None No No None None TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc April 1, 2020 / 15000 / Substance Stored Diesel / Tank Material- Mod Asphalt Coated or Bare Steel- Double-Walled ATG / LTT Test None LLD Test None Pipe Material- Mod None / Double-Walled Pipe type/STP Cont Pressure/Suction combo / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / Automatic shutoff / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-03-28 Page 1 of 3 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 1 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank 1 Suction Piping Leak Detection U.S. suction piping has a valid LTT every 3 years or monthly monitoring?Yes Piping qualifies as Safe Suction. (Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one check valve (under pump), and has proper slope of piping. If all these criteria are met, no leak detection is required on the piping.) No DISPENSER RESPONSES Dispenser 1 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Mar '23 Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS TANK 1 No Photos Question:Piping qualifies as Safe Suction. (Documentation is available and verifiable to show that piping operates at less than atmospheric pressure, has only one check valve (under pump), and has proper slope of piping. If all these criteria are met, no leak detection is required on the piping.) 2024-03-28 Page 2 of 3 Prepared by fueloperator.com Comments:None Inspection Information Inspector:Warner, Sean Record Created: March 28, 2024, 1:46 p.m. Inspection Date:March 28, 2024 2024-03-28 Page 3 of 3