HomeMy WebLinkAboutDERR-2025-002113195 North 1950 West • Salt Lake City, UT
Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840
Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. 800 346-3128
www.deq.utah.gov
Printed on 100% recycled paper
State of Utah
SPENCER J. COX
Governor
DEIDRE HENDERSON
Lieutenant Governor
Department of
Environmental Quality
Tim Davis
Interim Executive Director
DIVISION OF ENVIRONMENTAL
RESPONSE AND REMEDIATION
Brent H. Everett
Director
ERRP-069-25
March 24, 2025
Marc Westfall
7-Eleven, Inc.
P.O. Box 711
Dallas, Texas 75221
Re:No Further Action for Underground Storage Tanks
7-Eleven #33981, located at 425 North 700 West, Centerville, Utah
Facility Identification No. 3000242
Dear Mr. Westfall:
A review of the information submitted in the Closure Notice received on March 17, 2025,
for the above-referenced underground storage tanks, indicates that contaminant concentrations are
below State of Utah cleanup levels (Utah Admin. Code, R311-211-6). No corrective action is
currently required at this site for the lines and dispensers.
Corrective action may be needed in the future if contamination is found that exceeds State
of Utah cleanup levels.
If you have any questions regarding this matter, please contact Gary Harris, the Division
of Environmental Response and Remediation project manager, at (801) 536-4100.
Sincerely,
Brent H. Everett, Director
Division of Environmental Response and Remediation
BHE/GH/tt
cc: Brian E. Hatch, Director, Davis County Health Department
Jay Clark, Environmental Health Director, Davis County Health Department
GH3-17-2025
PETROLEUM STORAGE TANK PERMANENT CLOSURE NOTICE FACILITY ID# 3000242
State Use Only
Date Processed I by
Date Mailed to LIID
LUST ID#
Date to LUST Review
identified below b Josie Messersmith
Phone# (801) 261-0090
Address 2890 East Cottonwood Parkwa , Suite 300 Ci Salt Lake City State UT Zi 84121
FACILITY INFORMATION
Tank Owner 7-Eleven, Inc. I Phone# (214) 415-0146
Address PO Box 711 (Loe. 0148) I City Dallas State TX I Zip 75221-0711
Facility Name 7-Eleven Store No. 33981
Address 425 North 700 West I City Centerville State UT I Zip 84014
Contact person Marc Westfall Phone# (214) 415 -0146
Total number ofregulated petroleum storage tanks at this site before closure 4
Total number ofreg;ulated petroleum storage tanks at this site after closure 4
TANKS CLOSED
Piping Only Tank# 1 2 3 4 Ix] Please complete for each tank
Type (Steel,FRP,etc.) FRP FRP FRP FRP
Date Installed Piping 5/1/1999 Piping 5/1/1999 Piping 5/1/1999 Piping 5/1/1999
Capacity (Gallons) 12,000 10,000 10,000 10,000
Substance stored* GASOLINE GASOLINE GASOLINE DIESEL
Date last operated currently in use currently in use currently in use currently in use
Date Closed 12/16/2024 12/16/2024 12/16/2024 12/16/2024
Removed/In Place/Change in STPs, piping, dispensers, UDCs, and vent lines were removed and replaced. Service (CIS)?
*Indicate the specific substance stored m each tank to be closed (regular, unleaded, diesel, waste 011, etc.)
TANK REMOVER Name Taber Dehart I Cert.# TR 0418 I ExP. Date 3/15/2025
Company Westech Fuel Equipment I Phone# (435) 668-2554
Address PO Box 57307 I City Salt Lake City I State UT I Zip 84157
SOIL/GROUNDWATER SAMPLER Name Steve Yorgason I Cert. # GS 1630 I ExP. Date 04/15/2025
Company Stantec Consulting Services, Inc. I Phone# (801) 261-0090
Address 2890 East Cottonwood Parkway, Suite 300 I City Salt Lake City I State UT I Zip 84121
CLOSURE INFORMATION
Fuel was emptied DNA I Sludge was removed DNA I Tank was cleaned D NA
Tank was: I Purged D I Inerted D I Method Used: Not Applicable
Location of Closure Records: Stantec Consulting Services Inc.
For In-Place Closure: tanks filled with: NA
For Change-In-Service: Substance to be stored: NA
1
2-25-2025
DISPOSAL SITES USED
Location Name Contact Name Phone# Date Amount
Tank(s) NA ---Tank#
Product From Tank(s) NA -------
Contaminated Water NA From Tank Cleaning --------
Sludge NA --------
Contaminated Water
From Excavation NA ------
Contaminated Soil NA -------
SITE ASSESSMENT
Complete the Facility Site Plat (Closure Notice) and Sample Information Table (Closure Notice) on pages 3 and 4 to show the locations,
depths, and other information on all soil/groundwater samples taken for closure. The samples must be consistently identified by sample ID#
on the site plat, table, and lab analysis report.
I!] Completed Facility Site Plat (Closure Notice) is attached .
The following must be included (enter the distance, and direction (N,S,E,W) from the area of contamination or, where applicable,
use OH for overhead, NP for not present):
NP Water Line NP Sewer Line NP Natural Gas NP Storm Drain NP Telephone NP Electrical NP Property Line NP Buildings
!Xlcompleted Sample Information Table (Closure Notice) is attached.
!Xlcertified lab analytical environmental sample results are attached .
lx!Unified Soil Classification (USC) sample results are attached.
!xi chain of Custody form is attached .
Samples were properly: Ix! Collected [XI Labeled Ix! Packaged Ix] Transported
Ix] Samples were in sight of the person in custody at all times or in a secured locked place.
I certify under penalty of law that the closure site assessment at this facility was conducted in accordance with 40 CFR
280.52, 40 CFR 280.72, and U.A.C. R311-205, and that any additional samples required by 40 CFR 280.52, 40 CFR 280.72 and
U.A.C. R311-205-2(l)(a) were properly collected.
X,
Si~nature of Certified Groundwater/Soil Sampler r-~
I
I Date Full name of Certified Sampler Steve Y orgason
If contamination at the facility is confirmed, any person providing remedial assistance for a fee must be a Certified UST Consultant. The
Certified UST Consultant providing assistance is :
CERTIFIED UST CONSULTANT
Name Anna Skinner I Cert. #CC 0271 I Exp. Date 12/31/2026
Company Stantec Consulting Services Inc. I Address 2890 East Cottonwood Parkway, Suite 33
City Salt Lake City I State UT I Zip 83279 I Phone# 801-261-0090
Please explain any unusual circumstances that occurred during the site assessment or closure:
Soil sample SS-14 contained detectable napthalene and GRO, with levels below ISLs . Similarly, SS-22 had a detectable level ofDRO that was below
ISLs . Approximately 1 foot of pea gravel was present at the bottom of the piping trench. Samples were collected 8 to 10 inches below the bottom oftll
pea gravel. As indicated on the attached site-plat, an additional soil sample (SS-23) was completed due to a change in the excavation plan.
2
Facility Site Plat (Closure Notice)
The site plat must be drawn to an appropriate identified scale. It must show planned sampling locations, substances stored in tanks, and
other relevant information. Tank and sample identification numbers must be consistent with the information given on p. 1 and 4 of the
Closure Notice.
North
~ Scale: 1"= Feet
SEE ATTACHED SITE PLAT
I Facility ID: I DrawnBy:
X = Sample locations (SS-#, WS-#, USC-#)
0 = Monitoring Wells (MW-#)
D = Soil boring (SB-#), or Geoprobe Boring (GP-#)
• = Water Wells (domestic, livestock, etc.)
Slope of Surface Topography: (N,NW,W,SW,S,SE,E,NE)
Land Use At Site: _Residential _Commercial _Industrial
Surrounding Land: _Residential _Commercial _Industrial
3
I Date:
Site Plat Must Indicate Actual Locations Of:
✓ Current & former tanks, piping & dispensers
✓ Location of all samples to be taken
✓ Buildings, fences, & property boundaries
✓ Utility conduits (sewers, gas, water, storm drains, electrical, etc.)
✓ Depth to groundwater (if encountered)
✓ Excavations, GW monitoring wells & soil stockpiles
425 NORTH
PHILLIPS 66FORMER
STORE NO. 339817-ELEVEN
FOR:
JOB NUMBER:DRAWN BY:CHECKED BY:APPROVED BY:DATE:
ELEVEN
0
(,n-n-Out Burger)
u,
'I'"
I -Ill
= I-
= Ill
I-z -
-+-CLOSURE SOIL SAMPLE
SA-SEWER
E-ELECTRICAL
G-NATURAL GAS
W· WATER
t:'
()stantec
2890 E COTTONWOOD PKWf, STE 300
SALT LAKE CITY, UTAH
PHONE : (801) 261-0090
~
STORE NO. 33981
425 NORTH 700 WEST
CENTERVILLE, UTAH
203724144
FILEPATH : U:\203724144\0S_report_ deliv\deliverable\cp\cp _site_plan_ 33981.pdf
♦
55.5
I ss.1-+-
I ~
I SS-9 1!.::f :ll
-----..iS~-11 •♦·
~ r:,-]I SS-141f:,
1U 12
DISPENSER
·♦.I SLANDS ♦
ls.15 E♦ll ss.11 E♦
14 ,a
♦SS -19 I
1 ~ 1 SS-18 •♦·
17
CURRENT
STs
20 E♦J1 -♦-
10 SS-21
£.♦lJ SS-22 1'.._
20 1 "'CANOPY
e-==-,=e-==-,~
0
0
"""
No warranty is made by Stantec Consulting Services Inc. as to the accuracy, reliability, or completeness of these data. Original data were
compiled from various sources. This infom,ation may not meet National Map Accuracy Standards. This product was developed
electronically, and may be updated without notification. Any reproduction ma y result in a loss of scale and or information.
FIGURE:
SITE PLAN 1
JR/AS 10/24/2024
SAMPLE INFORMATION TABLE (Closure Notice)
Complete table for all samples that were taken for closure. Sample ID numbers on the table must be consistent with the sample ID
numbers given on the site plat and in the lab analysis report.
Sample Substance Sample Depth2 Compounds3 Analysis method(s)4 # stored in tank type1
SS-1 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-2 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-3 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-4 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-5 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-6 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-7 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-8 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-9 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-10 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-11 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-12 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-13 gasoline and diesel ss 3 MBTEXN, GRO, and ORO 8260 and 8015
SS-14 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SS-15 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SS-16 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SS-17 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SS-18 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SS-19 gasoline and diesel ss 3 MBTxEXN, GRO and ORO 8260 and 8015
SS-20 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SS-21 gasoline and diesel ss 3 MBTEXN, GRO and ORO 8260 and 8015
SAMPLE INFORMATION CONTINUES ON PAGE 5
4
2/19/25
SAMPLE INFORMATION TABLE (Closure Notice)
Complete table for all samples that were taken for closure . Sample ID numbers on the table must be consistent with the sample ID
numbers given on the site plat and in the lab analysis report.
Sample Substance Sample Depth2
# stored in tank tvpe1
SS-22 gasoline and diesel ss 3
SS-23 gasoline and diesel ss 3
USC-1 gasoline and diesel USC 3
USC-2 gasoline and diesel USC 3
1 Soil (SS), Groundwater (GW), or Unified Soil Classification (USC).
2 Final depth (in feet) below grade at which samples were taken .
3 Contammant compound(s) analyzed for each sample (TPH , BTEXN , O&G , etc).
4 Appropriate analysis methods for contaminant compound(s) in each sample
State Certified Laboratory used Chemtech-Ford
Address 9632 South 500 West
Compounds3 Analysis method(s)4
MBTEXN, GRO, and DRO 8260 and 8015
MBTEXN, GRO, and DRO 8260 and 8015
USC ASTM-D2487
USC ASTM-D2487
I Citv Sandv I State UT I Zip 84070
Contact Person Mark Broadhead I Phone# (801) 262-7299
I certify under penalty oflaw that I am the Owner of the tank(s) described above and that I am familiar with the information on this form
and that it is true, accurate and complete and further, that the procedures described herein were followed during tank closure.
Si nature of PST owner
Full Name of owner Marc Westfall Date
Return completed Closure Notice form, Facility Site Plat and Sample Information Table, Soil/Groundwater sample lab analysis results,
USC sample results, and Chain of Custody form within 90 days of PST Closure to :
Mailing Address : Street Address:
State of Utah Dept. of Environmental Quality
DERR I PST Section
P .O . Box 144840
Salt Lake City, Utah 84114-4840
Multi Agency State Office Building
195 North 1950 West (First Floor)
Salt Lake City, Utah 84116
5