Loading...
HomeMy WebLinkAboutDAQ-2025-001499I,TAH DEPAflTMENT OF HE'(CEL& Hand Delivered September 12,2024 Mr. Bryce Bird, Director Utah Division of Air Quality Department of Environmental Quality 1950 West North Temple Salt Lake City, Utah 84116-4820 Re: Semi-Annual Compliance Reports - 40 CFR Part 63 Subpart HHHHH: Miscellaneous Coating Manufacturing Hexcel Corporation - Salt Lake City Operations AO Num ber - DAQE-ANI 13860 035-22 Dear Mr. Bird, In accordance with the Approval Order DAQE-ANl13860035-22 and 40 CFR Part 63 Subpart HHHHH: Miscellaneous Coating Manufactun'ng, Hexcel Corporation (Hexcel) is submitting the Semi-Annual Compliance Report. This report covers the period from March 15, 2024, to September 15,2024. If you have any questions, please contact me at the information found below. Thanks, ;H"^< Tyson Hone SLC Site Environmental Manager Hexcel Corporation Tyson.Hone@Hexcel.com (38s) 831-3472 [,rn/ Ad,ysv14 REVIEWEDInitials:Date: Mar 20, 2025Compliance status: In ComplianceFile #: 11386 (B2) HE'(CEL& 40 CFR Part 63 Subpart HHHHH: Miscellaneous Coating Manufacturing Semi-Annual Compliance Report In accordance with 40 CFR 63.8075, sections (e) Compliance Report (e)(1) through (8), Hexcel is required to submit a compliance report to the Utah Division of Air Quality (UDAQ) covering the six-month period from the last compliance report. The previous six-month compliance report period ended on March 15,2024. This report covers the following six (6) month period: Beginning: 03-15-2024 Ending: 09-15-2024 Section 1. - Facility Information Operatin g Perm it Number: DAQE-AN 1 I 3 86003 5 -22 Responsible OfficialName/Title: Tyson Hone - SLC Site Environmental Manager Street Address: 6700 S 5400 W City: West Valley City State: Utah ZipCode:84118 Facility Name: Hexcel Corporation - Salt Lake City Operations Facility Street Address: Same Facility Contact NamelTitle: Tyson Hone - SLC Site Environmental Manager Contact Phone Number: (385) 831-3472 Section 2. - Applicable records and information for periodic reports as specified in referenced subparts F, SS, TT, UU, and WW of this part 63. 40 CFR 63 Subpart F - This subpart is not applicable to the site as Hexcel does not meet the following applicability requirements found in 40 CFR 63.1800(b). 40 CFR 63 Subpart S,S - Hexcel's Mix Room regenerative thermal oxidizer (RTO) and closed vent system are regulated under 40 CFR 63 Subpart SS. The closed vent vapor collection systems are designed and operated under negative pressure. There was no needed maintenance performed on the emergency by-pass valve during this reporting period. The emergency bypass vent was not actuated or opened during the reporting period. Hexcel has temperature data for the Mix Room RTO on file for this period. There was no indication that during this period these units fell outside of temperature requirements while regulated hazardous air pollutant (HAP) chemicals were in unit. _.qi1r1 urpnnTM-FNTG- EXVIRONMENTAL QUALITY DIVISION OF AIR QUALITY 40 CFR 63 Subpart 7I- This subpart is not applicable to Hexcel. HE'(CEL& 40 CFR 6j Subpart UU - This subpart is not applicable to Hexcel. Hexcel does not store any hazardous air pollutant (HAP) chemicals in bulk storage tanks or dispense HAP chemicals via a pressurized piping system. The only solvents that are stored in bulk and dispensed through a pressurized piping distribution system are acetone and methyl ethyl ketone (MEK), which are not listed as HAPs. Any listed HAP is dispensed (poured or pumped) from individual drums placed immediately adjacent to the mix vessel inside the building. 40 CFR 63 Subpart WW - The size of the tanks on site are below the threshold for Group la and Group lb storage tanks and did not contain HAP chemicals, so these requirements are not applicable. Section 3. - Deviations from Emission Limits, Operating Limits or Work Limits. This section specifies any deviations from emission limits, operating limits or work limits the occurred during the reporting period. During the reporting period there were no incidents where the Mix House RTO deviated from emission limits, operating limits, or work practices. Section 4. - Certification In accordance with Approval Order DAQE-ANI13860032-19 and 40 CFR 63.8075(eX2) based on information and belief formed after reasonable inquiry, I certiff that the statements information in this document are true, accurate and complete. and and FH-'.al I tz /zrl (Signature of Responsible Offi cial)(Date) fyson Hone site Environmenlal ruona!Cf (Print or type the name and title of Responsible Official)