Loading...
HomeMy WebLinkAboutDERR-2025-001963UTAH STATE FUEL NETWORK 4315 S 2700 W SALT LAKE CITY, UT 84129 RE:Request for Petroleum Storage Tank Records EMERY UDOT STA #4457, located at 250 S 200 E, EMERY Facility Identification No. 5000215 Dear : PST operators are required to ensure that certain tests are conducted for their tank system. Dates highlighted in "Yellow" - tests are due soon. Dates highlighted in "Red" - tests are due and you are out of compliance. Tank ID/Alt ID Description LTT -------------------- LLD Spill Bucket -------------------- Overfill Tank or Flex -------------------- Pipe CP ATG -------------------- Sump 3/3 Diesel-Diesel #2 (U.L.S.)-4000 2/20/2025 N/A N/A N/A N/A N/A N/A N/A 4/4 Gasoline-Regular-2000 2/20/2025 N/A N/A N/A N/A N/A N/A N/A LTT - Line Tightness Test LLD - Line Leak Detector Overfill ±Overfill Device Tank or Flex/Pipe CP - Corrosion Tests ATG ±Automatic Tank Gauging Sump - Tank Top Sump and applicable Dispenser Sumps Please note that UDC tests are not listed, but are required on your facility's next sump test cycle starting July 1, 2023, if applicable. Also, effective immediately pressure vent valves must be tested every three years for gasoline tanks. Please submit a copy of the required tests to the DERR within 30 days of the date due. If you have any questions please call David Wilson at 801-536-4100. 195 North 1950 West - Salt Lake City, UT Mailing Address: - P.O. Box 144840 - Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 - Fax (801) 359-8853 - T.D.D. (801) 536-4414 www.deq.utah.gov Printed on 100% recycled paper January 07, 2025 State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 T.E.I. SYSTEM 4000 / T.E.I. LT3 / T.E.I. ULLAGE PRECISION TANK & LINE TEST RESULTS SUMMARY INVOICE ADDRESS: TANK LOCATION: WORK ORDER # TECH # 94027 VAN # 8502 TECHNICIAN: SM STATE TECH # STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 UTAH DOT#436 # 5000215 250 SOUTH 200 EAST EMERY, UTAH 25005 UT 0121 DATE:2-25-2025 TIME START: TIME END: GROUNDWATER DEPTH: TIME SYSTEM FILLED OR TOPPED: TANK TANK CAPACITY 2000 4000 PRODUCT R/UL DSL TANK VENT PRODUCT LINE PASS PASS LINE LEAK DETECTOR PASS PASS WATER IN TANK PUMP TYPE PRESS PRESS TANK MATERIAL CONVAULT CONVAULT 1 2 3 4 5 6 PRODUCT LINES TESTED AT 50 PSI FOR 15 MINUTES LINE RATES (GPH) 1 2 3 4 5 6 R/UL -.002 DSL -.005 ADDITIONAL INFORMATION:MECHANICAL LINE LEAK DETECTORS PASS 3 GPH SIMULATED LEAK TEST ABOVEGROUND TANKS WITH UNDERGROUND PRODUCT LINES INSTALLED NEW PV VALVE ON UNLEADED VENT CERTIFIED TECHNICIAN SIGNATURE: DATE:2-25-2025 All tests are performed in a professional manner, and within common practices of the industry. However due to the variables of tank testing, these results cannot be guaranteed. There are no warranties expressed, written or implied. These systems meet all requirements set forth by USEPA 40 CFR and has recieved third party certification. Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 08:28:07 -07'00' Reason: I am the author of this document UTAH STATE FUEL NETWORK AST ANNUAL INSPECTION Facility Name and Site Address: Date: Facility ID # Purpose:Regular Reinspection Complaints Annual Inspection Nu m b e r Te s t e d Sa t i s f i e d Re j e c t e d A d v i s e Pumps Tested for Calibration Is tank grounding strap in good condition ? Is tank coating free of corrosion / damage ? Is tank free of noticable distortion, denting, buckeling ? Flanged connection bolts appear tight ? Normal and emergency vents appear in good condition ? Inspection Remarks: Technician signature Inspected By: Steven B. Martin UT121 Applied Environmental Services L.C. UTAH DOT # 436 250 SOUTH 200 EAST EMERY, UTAH 2-25-2025 5000215 X X X X X NO DEDICATED GROUND STRAPS X X N/A X X INSTALLED NEW PV VALVE X State Fuel Contact : Brett Gurney 385-602-4872 801-540 9258 Aesutah@aol.com Email: Brettgurney@utah.gov X X X X X X X X Fill and vapor connections in good condition ? CONVAULT ASTS WITH UNDERGROUND PRODUCT LINES INSTALLED NEW PV VALVE ON UNLEADED VENT XTank containment structure in satisfactory condition ? Free of tank settlement and foundation washout ? Tank supports in satisfactory condition ? Is water able to drain off tank pad and tank top ? Gasoline vent has P/V valve installed where required ? Valves / syphons / solenoids appear in good condition ? Spill containment visable and appears in good condition Electrical junction boxes and conduits in good condition Tank monitor free of active alarms ? Emergency shutoff installed ? Dispenser static test ? Tank overfill equipment installed ? Piping sumps appear in good condition ? COMMENTS / ACTION Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 08:30:58 -07'00' Reason: I am the author of this document UTAH DOT # 436 250 SOUTH 200 EAST EMERY, UTAH 5000215 STATE FUEL NETWORK APPLIED ENVIRONMENTAL SERVICES PO BOX 141152 SALT LAKE CITY, UT BRETT GURNEY 385-602-4872 801-540-9258 2-25-2025 1 R/UL RED J FX1V X 29 12 200 3 9 3 X X X X 2 DSL RED J FX2D X 29 12 200 2 11 2 X X X X STEVEN B MARTIN Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2025.03.11 08:33:11 -07'00' Reason: I am the author of this document