Loading...
HomeMy WebLinkAboutDRC-2025-000261Deq submit <dwmrcsubmit@utah.gov> Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks 1 message LLRW DWMRC <llrw@utah.gov>Thu, Jan 23, 2025 at 2:26 PM To: Deq submit <dwmrcsubmit@utah.gov> DRC ---------- Forwarded message --------- From: Carlo Romano <cromano@utah.gov> Date: Thu, Jan 23, 2025 at 8:55 AM Subject: Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks To: LLRW DEQ <llrw@utah.gov> Please see attached. Carlo Romano, PE Environmental Engineer III Division of Waste Management and Radiation Control Phone: 385-977-7573 | wasteandradiation.utah.gov Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. Statements made in this email do not constitute the official position of the Director of the Division of Waste Management and Radiation Control. If you desire a statement of the Division Director’s position, please submit a written request to the Director, including copies of documents relevant to your request. ---------- Forwarded message --------- From: Carlo Romano <cromano@utah.gov> Date: Wed, Jan 22, 2025 at 2:40 PM Subject: Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks To: Larry Kellum <lkellum@utah.gov> Hi Larry, I need this document uploaded into EQDocs so it can be assigned a DRC # and I can reference this in a letter. Pretty sure I am supposed to send this to LLRW email but I wasn't sure. Should I be sending this to you or to Alekz/Peter? 1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…1/4 Carlo Romano, PE Environmental Engineer III Division of Waste Management and Radiation Control Phone: 385-977-7573 | wasteandradiation.utah.gov Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. Statements made in this email do not constitute the official position of the Director of the Division of Waste Management and Radiation Control. If you desire a statement of the Division Director’s position, please submit a written request to the Director, including copies of documents relevant to your request. ---------- Forwarded message --------- From: Garrett Q. Dutson <gqdutson@energysolutions.com> Date: Wed, Jan 8, 2025 at 1:45 PM Subject: RE: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks To: Carlo Romano <cromano@utah.gov> Cc: Lawrence Kellum <lkellum@utah.gov>, Vern C. Rogers <vcrogers@energysolutions.com>, Bailey Anderson <bmanderson@utah.gov>, Brandon Davis <bbdavis@utah.gov>, Garrett Q. Dutson <gqdutson@energysolutions.com>, Dave Booth <dbooth@energysolutions.com>, Nick Clarke <nmclarke@energysolutions.com> Hi Carlo. Thank you for meeting with us. Attached is the RB&G report showing the 28 day compressive strength test results for the Southern wall pour (erroneously labeled by the testing lab as “IVF west wall”) poured on November 11, 2024. The cylinders met the project’s design strength of 4,000 psi at 28 days (see Drawing 9705-2(1)). Please note that although the supplier’s mix design strength is 4500 psi the work and the wall looked great both during the pour and after field curing including while the drain holes were being drilled and then lined with the PVC sleeves. Please let us know if you have further questions. Thank you. Garrett Q. Dutson, PE 1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…2/4 Project Engineer IV, Clive ENERGYSOLUTIONS 299 South Main Street Suite 1700 Salt Lake City, UT 84111 Direct: 801.649.2156 Cell: 801.721.1425 Email: gqdutson@energysolutions.com From: Carlo Romano <cromano@utah.gov> Sent: Wednesday, January 8, 2025 1:09 PM To: Garre Q. Dutson <gqdutson@energysolutions.com> Cc: Lawrence Kellum <lkellum@utah.gov>; Vern C. Rogers <vcrogers@energysolutions.com>; Bailey Anderson <bmanderson@utah.gov>; Brandon Davis <bbdavis@utah.gov> Subject: [EXTERNAL] IUF Construcon As-Builts: Remaining 28-day strength breaks EXTERNAL: This message is from a NON-EnergySoluons sender, please ensure it is from a legimate source. DO NOT click links or open aachments if sender is unknown or the message seems suspicious in any way. Good afternoon Garrett, As mentioned in our meeting Monday 1/6/2025, I have completed a review of the IUFConstruction As-Built Report. I noticed that the report was submitted prior to the inclusion of the 28-day breaks for the South Wall modification. Could you provide a copy of the data sheet showcasing that the concrete used to pour the South Wall has met strength specifications? That's all I need to wrap up our review. I will note of this correspondence in the subsequent Division response letter. Thank you, 1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…3/4   Carlo Romano, PE Environmental Engineer III Division of Waste Management and Radiation Control Phone: 385-977-7573 | wasteandradiation.utah.gov Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. Statements made in this email do not constitute the official position of the Director of the Division of Waste Management and Radiation Control. If you desire a statement of the Division Director’s position, please submit a written request to the Director, including copies of documents relevant to your request. Conc__Set IVF (11-11)_2024-11-11_1027370 28 day south wall.pdf 233K 1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…4/4 T. Henderson Set IVF (11-11) Area Location Field Technician J. Kenison IVF Facility IVF west wall Date/Time 11/11/2024 CONCRETE CYLINDERS Lab Technician 7:28 AM Concrete Supplier Kilgore Truck No.76020431 Ticket No.246 Design Strength 4,500 psi at 28 days Design Mix 4500 PSI 7 1/4 Design Air (%)NA Date Retrieved 11/19/2024 Design Slump (in) Air Temp (°F)43 Concrete Temp (°F)63 Concrete (cu yds)10 NA NA Water Added (gal) Authorized By Slump (in)7 1/4 NTAir Content (%) Sample Location Weather Fair, cloudy 1 of 1Sheet PO 721936 1027370Report No. RBG No.202408-007 ENERGY SOLUTIONS Grantsville UT Diameter x Length (in) 1 COMPRESSIVE DIMENSIONS STRENGTH (psi) FRACTURE TYPE SPECIFIED STRENGTH (psi) MAXIMUM LOAD (lbs) BREAK DATE AGE (days) TEST ID Area (sq in) NOTES/CONDITION (i.e. moisture condition, defects, curing history, sawed or molded, etc.) See footer secton for further explanation. (samples considered normal if blank) 12.574.00 x 7.9532,8903634011/19/20248A Field cure12.574.00 x 7.8052,6103275011/19/20248B 12.574.00 x 7.9063,0803867011/25/202414C Field cure12.574.00 x 7.9563,1003899011/25/202414D Out of spec. 12.574.00 x 8.00345004,0305063012/9/202428E Out of spec. Field cure12.574.00 x 8.00245004,0405076012/9/202428F HG REMARKS Field cures were laying on side a couple days later after being made. 4,035 Average 28-day Strength (psi) : EnergySolutions 299 South Main Street Ste 1700 Salt Lake City UT 84111 Client Technical 1435 West 820 North Provo, Utah 84601 801-374-5771 Provo 801-521-5771 Salt Lake City 12/10/2024Date Printed KEY Out of Spec/Fail: Out of compliance with plans and specifications. Results relate only to the items tested. This report shall not be reproduced, except in full, without the prior written approval of RB&G Engineering, Inc. Accreditation is granted by AAP and is limited to the standards for whichthe RB&G laboratory is accredited. FRACTURE TYPE (ASTM) CL Centerline H Hold NA Not available/applicable NT Not tested/required All samples are considered normal condition unless listed in Notes above. Compressive strength results are as per ASTM C39. Slump and air are as per ASTM C143 and C231. Temperature: ASTM C1064. Sampling: ASTM C172. Unbonded capping: ASTM C1231 Robert Johnson, PE (prin.), Jacob Boone (lab mgr), Luke Price (asst lab mgr) dquackenbush@energysolutions.com gqdutson@energysolutions.com jmcason@energysolutions.com 1 1 2 3 4 5 6