HomeMy WebLinkAboutDRC-2025-000261Deq submit <dwmrcsubmit@utah.gov>
Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
1 message
LLRW DWMRC <llrw@utah.gov>Thu, Jan 23, 2025 at 2:26 PM
To: Deq submit <dwmrcsubmit@utah.gov>
DRC
---------- Forwarded message ---------
From: Carlo Romano <cromano@utah.gov>
Date: Thu, Jan 23, 2025 at 8:55 AM
Subject: Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
To: LLRW DEQ <llrw@utah.gov>
Please see attached.
Carlo Romano, PE
Environmental Engineer III
Division of Waste Management and Radiation Control
Phone: 385-977-7573 |
wasteandradiation.utah.gov
Emails to and from this email address may be considered public records and thus subject to
Utah GRAMA requirements.
Statements made in this email do not constitute the official position of the Director of the
Division of Waste Management and Radiation Control. If you desire a statement of the
Division Director’s position, please submit a written request to the Director, including copies of
documents relevant to your request.
---------- Forwarded message ---------
From: Carlo Romano <cromano@utah.gov>
Date: Wed, Jan 22, 2025 at 2:40 PM
Subject: Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
To: Larry Kellum <lkellum@utah.gov>
Hi Larry,
I need this document uploaded into EQDocs so it can be assigned a DRC # and I can reference this in a letter. Pretty sure
I am supposed to send this to LLRW email but I wasn't sure. Should I be sending this to you or to Alekz/Peter?
1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…1/4
Carlo Romano, PE
Environmental Engineer III
Division of Waste Management and Radiation Control
Phone: 385-977-7573 |
wasteandradiation.utah.gov
Emails to and from this email address may be considered public records and thus subject to
Utah GRAMA requirements.
Statements made in this email do not constitute the official position of the Director of the
Division of Waste Management and Radiation Control. If you desire a statement of the
Division Director’s position, please submit a written request to the Director, including copies of
documents relevant to your request.
---------- Forwarded message ---------
From: Garrett Q. Dutson <gqdutson@energysolutions.com>
Date: Wed, Jan 8, 2025 at 1:45 PM
Subject: RE: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
To: Carlo Romano <cromano@utah.gov>
Cc: Lawrence Kellum <lkellum@utah.gov>, Vern C. Rogers <vcrogers@energysolutions.com>, Bailey Anderson
<bmanderson@utah.gov>, Brandon Davis <bbdavis@utah.gov>, Garrett Q. Dutson <gqdutson@energysolutions.com>,
Dave Booth <dbooth@energysolutions.com>, Nick Clarke <nmclarke@energysolutions.com>
Hi Carlo.
Thank you for meeting with us.
Attached is the RB&G report showing the 28 day compressive strength test results for the Southern wall
pour (erroneously labeled by the testing lab as “IVF west wall”) poured on November 11, 2024. The
cylinders met the project’s design strength of 4,000 psi at 28 days (see Drawing 9705-2(1)).
Please note that although the supplier’s mix design strength is 4500 psi the work and the wall looked great
both during the pour and after field curing including while the drain holes were being drilled and then lined
with the PVC sleeves.
Please let us know if you have further questions.
Thank you.
Garrett Q. Dutson, PE
1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…2/4
Project Engineer IV, Clive
ENERGYSOLUTIONS
299 South Main Street
Suite 1700
Salt Lake City, UT 84111
Direct: 801.649.2156
Cell: 801.721.1425
Email: gqdutson@energysolutions.com
From: Carlo Romano <cromano@utah.gov>
Sent: Wednesday, January 8, 2025 1:09 PM
To: Garre Q. Dutson <gqdutson@energysolutions.com>
Cc: Lawrence Kellum <lkellum@utah.gov>; Vern C. Rogers <vcrogers@energysolutions.com>; Bailey Anderson
<bmanderson@utah.gov>; Brandon Davis <bbdavis@utah.gov>
Subject: [EXTERNAL] IUF Construc on As-Builts: Remaining 28-day strength breaks
EXTERNAL: This message is from a NON-EnergySolu ons sender, please ensure it is from a legi mate
source.
DO NOT click links or open a achments if sender is unknown or the message seems suspicious in any
way.
Good afternoon Garrett,
As mentioned in our meeting Monday 1/6/2025, I have completed a review of the IUFConstruction As-Built Report. I
noticed that the report was submitted prior to the inclusion of the 28-day breaks for the South Wall modification. Could you
provide a copy of the data sheet showcasing that the concrete used to pour the South Wall has met strength
specifications? That's all I need to wrap up our review. I will note of this correspondence in the subsequent Division
response letter.
Thank you,
1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…3/4
Carlo Romano, PE
Environmental Engineer III
Division of Waste Management and Radiation Control
Phone: 385-977-7573 |
wasteandradiation.utah.gov
Emails to and from this email address may be considered public records and thus subject to
Utah GRAMA requirements.
Statements made in this email do not constitute the official position of the Director of the
Division of Waste Management and Radiation Control. If you desire a statement of the
Division Director’s position, please submit a written request to the Director, including copies of
documents relevant to your request.
Conc__Set IVF (11-11)_2024-11-11_1027370 28 day south wall.pdf
233K
1/23/25, 4:04 PM State of Utah Mail - Fwd: [EXTERNAL] IUF Construction As-Builts: Remaining 28-day strength breaks
https://mail.google.com/mail/b/AEoRXRS9HYVR1ytk0g9dInjc_3EMc6DLTqwGxNyr_Aqz3hjMWatD/u/0/?ik=adf9d5e615&view=pt&search=all&permthid…4/4
T. Henderson
Set IVF (11-11)
Area Location
Field Technician J. Kenison
IVF Facility
IVF west wall
Date/Time 11/11/2024
CONCRETE CYLINDERS
Lab Technician
7:28 AM
Concrete Supplier Kilgore
Truck No.76020431
Ticket No.246
Design Strength 4,500 psi at 28 days
Design Mix 4500 PSI
7 1/4
Design Air (%)NA
Date Retrieved 11/19/2024
Design Slump (in)
Air Temp (°F)43
Concrete Temp (°F)63
Concrete (cu yds)10
NA
NA
Water Added (gal)
Authorized By
Slump (in)7 1/4
NTAir Content (%)
Sample Location
Weather Fair, cloudy
1 of 1Sheet
PO 721936
1027370Report No.
RBG No.202408-007
ENERGY SOLUTIONS
Grantsville UT
Diameter
x Length
(in)
1
COMPRESSIVE
DIMENSIONS
STRENGTH
(psi)
FRACTURE
TYPE
SPECIFIED
STRENGTH
(psi)
MAXIMUM
LOAD
(lbs)
BREAK
DATE
AGE
(days)
TEST
ID
Area
(sq in)
NOTES/CONDITION
(i.e. moisture condition, defects, curing
history, sawed or molded, etc.)
See footer secton for further explanation.
(samples considered normal if blank)
12.574.00 x 7.9532,8903634011/19/20248A
Field cure12.574.00 x 7.8052,6103275011/19/20248B
12.574.00 x 7.9063,0803867011/25/202414C
Field cure12.574.00 x 7.9563,1003899011/25/202414D
Out of spec. 12.574.00 x 8.00345004,0305063012/9/202428E
Out of spec. Field cure12.574.00 x 8.00245004,0405076012/9/202428F
HG
REMARKS
Field cures were laying on side a couple days later after being made.
4,035 Average 28-day Strength (psi) :
EnergySolutions
299 South Main Street
Ste 1700
Salt Lake City UT 84111
Client
Technical
1435 West 820 North
Provo, Utah 84601
801-374-5771 Provo
801-521-5771 Salt Lake City
12/10/2024Date Printed KEY
Out of Spec/Fail: Out of
compliance with plans and
specifications.
Results relate only to the items tested. This report shall not be reproduced,
except in full, without the prior written approval of RB&G Engineering, Inc.
Accreditation is granted by AAP and is limited to
the standards for whichthe RB&G laboratory is
accredited.
FRACTURE TYPE (ASTM)
CL Centerline
H Hold
NA Not available/applicable
NT Not tested/required
All samples are considered normal condition unless listed in Notes above.
Compressive strength results are as per ASTM C39. Slump and air are as per
ASTM C143 and C231. Temperature: ASTM C1064. Sampling: ASTM C172.
Unbonded capping: ASTM C1231
Robert Johnson, PE (prin.), Jacob Boone (lab mgr),
Luke Price (asst lab mgr)
dquackenbush@energysolutions.com
gqdutson@energysolutions.com
jmcason@energysolutions.com
1
1 2 3 4 5 6