HomeMy WebLinkAboutDSHW-2023-091480Site Information Finalized Yes Facility Name Duchesne_Wasatch-Bluebench MSW Landfill Facility_ID 114 Facility Name Duchesne_Wasatch-Bluebench MSW Landfill Street Address 2000 South 20550 West, UT-87, Duchesne, UT 84021 City Duchesne ZIP Code 0 County Duchesne County Inspection Date 07-14-2023 Type of Visit Routine Oversite Is the Visit Announced?Yes 0.000000, 0.000000 Weather Conditions Sunny, High of 90 degrees Fahrenheit Inspection Goal Follow-Up on facility request to view Class IV material area and discuss windblown trash mitigation Facility Contact Hal Giles Participants Bryan Watt Hal Giles Follow Up Inspection Needed?Yes Recommended Follow Up Date 08-14-2023 Depart Office Date 07-14-2023 Depart Office time 07:00 AM (-6 GMT) Return to Office Date 07-14-2023 Return to Office time 12:00 PM (-6 GMT) 1. Pre-Inspection Review 1.1 Permit Review Yes Comment Class IV material location appears to be within the rules of the permit 1.2 Annual Report Review No Comment None 1.3 Previous Inspection Review Yes Comment None 1.4 Facility Contacts Confirmed Yes Comment Hal Giles confirmed as contact Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 1 of 7 1.5 Facility Contacted (If an announced inspection) Yes Comment Combined inspection with request from Hal Giles to view new Class IV location 1.6 Local Health Contacted No Comment None 1.7 Other No Comment None 2. Facility / Operational Controls (1-Good, 5-Poor) 2.1 Litter 3 2.2 Roads 1 2.3 Gate House Operations 1 2.4 Vectors 1 2.5 Communications 1 2.6 Recycling Area 1 2.7 Fugitive Dust Control 2 2.8 Waste Inspection Area 2 2.9 Scavenging Control 2 2.10 Open Burning 1 2.11 Fences, Gates, Locks, Access Control 1 2.12 Working Face 2 2.13 Daily - Soil 4 2.14 Daily - Alternative 1 2.15 Leachate Collection System 1 2.16 Other NA Comment (Required)As turning up the working face in windy conditions has historically been an issue, this does not appear to be the only factor contributing to wind-blown waste issue. Daily cover will likely need to be thicker than 1” as this amount of cover does not appear to be thick enough, particularly in areas prone to high winds. 3. Signs Required / Properly Posted 3.1 Operating Days / Hours Yes 3.2 Directions & Procedures Yes 3.3 Emergency Numbers Yes 3.4 List of Unacceptable Materials Yes 3.5 Other N/A Comment (Required)None Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 2 of 7 4. Operator / Representative / Employees 4.1 On-site While Open Yes 4.2 Training Yes 4.3 Other N/A Comment (Required)None 5. Monitoring 5.1 Methane N/A 5.2 Random Inspections No 5.3 Leachate Yes 5.4 Ground Water Yes 5.5 Other N/A Comment (Required)Daily random inspections need to be documented 6. Drainage / Erosion 6.1 Water Run-on Yes 6.2 Water Run-off Yes 6.3 Other N/A Comment (Required)None 7. Proper Storage / Isolation / Disposal 7.1 Special Waste Yes 7.2 Batteries N/A 7.3 Hazardous Waste N/A 7.4 Infectious Waste N/A 7.6 Dead Animals N/A 7.7 Asbestos N/A 7.8 Bulky Waste N/A 7.9 Contaminated Soil Yes 7.10 Ash Yes 7.11 Sludge N/A 7.12 Other N/A Comment (Required)None 8. Cover 8.1 Intermediate No 8.2 Final Yes 8.3 Vegetation Yes Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 3 of 7 8.4 Other N/A Comment (Required)Vegetation established n some slopes. May need to incorporate seeding program to help stabilize steep bank slopes with rill erosion 9. Inspection Records 9.1 Random Inspection Report No 9.2 Gas Monitoring System N/A 9.3 Surface Drainage Control Yes 9.4 Daily Records Yes 9.5 Weight or Volumes Yes 9.6 Intermediate Cover No 9.7 Final Cover Yes 9.8 Self Inspection (Quarterly Reports) Yes 9.9 Deviation From Plans No 9.10 Permit, Permit Application, and Rules Available Yes 9.11 Other N/A Comment (Required)Daily inspections need to occur and be documented 10. Monitoring / Sampling / Analysis Records 10.1 Explosive Gas Monitoring No 10.2 Leachate Sampling & Treatment Yes 10.3 Ground Water Sampling Results Yes 10.4 Other N/A Comment (Required)None 11. Special Waste Records 11.1 Lab Analysis Results N/A 11.2 Manifests N/A 11.3 Treatment Certification N/A 11.4 Paint Filter Test Results N/A 11.5 Onsite Treatment Documentation N/A 11.6 Other N/A Comment (Required)None 12. Waste Tires Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 4 of 7 12.1 Acceptance procedures for Waste Tires Yes 12.2 Waste Tire Pile Segregated Yes 12.3 Estimated Quanitity of Waste Tires Yes Number of Tires 2000 12.4 Waste Tire Fund Training No Comment (Required)Tires need to be transported. Some loose tires also need to be gathered up into one pile. Hal mentioned that he was in the process of getting rid of the tires 13 Other Items 13.1 Notice of Inspections Form Completed and Signed N/A 13.2 N/A 13.3 N/A 13.4 N/A Comment (Required)None 14. Special Permit Requirements 14.1 N/A 14.2 N/A 14.3 N/A Comment (Required)None General Comments Comments RESUBMISSION - Original Inspection Report was not transferred to EQDocs and cannot be accessed through EQDocs Trash scattered throughout permitted and unpermitted areas continues to be gradually cleaned up utilizing people and vacuum equipment. DWMRC Inspector Signature DWMRC Inspector Name Bryan Watt Date/Time 07-14-2023 Photos Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 5 of 7 Attach Photos Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 6 of 7 Form Locations Date Submitted: 03-14-2025 12:00 PM Submitted By: bryanwatt@utah.gov Solid Waste Program Facility Inspection Report Checklist Copy Page 7 of 7