Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2025-001841
IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 3/11/2025 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 3/10/2025 Order Number: 2378175 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #29514, MKT 1606 309 EAST 400 SOUTH State ID 4001444 SALT LAKE CITY, UT 84111 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2378175 Date: 3/10/2025 Site Name/ID: 7-ELEVEN #29514, MKT 1606 / 29514 Address: 309 EAST 400 SOUTH State ID 4001444 City: SALT LAKE CITY State: UT Zip: 84111 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 TNK1 Regular RUL 2 Pressure 50 10:26 10:56 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 TNK2 Regular RUL Pressure 50 10:26 10:56 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 TNK3 Premium PUL Pressure 50 10:26 10:56 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #29514, MKT 1606 309 EAST 400 SOUTH State ID 4001444 SALT LAKE CITY UT 84111 29514 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 03/10/2025 RUL 2 RUL Veeder Root PLLD Veeder Root PLLD Veeder Root PLLD 30 2 30 2 2 26 UT151 David Mathie NW1-2378175 PUL TTNK1 Regular:1 TTNK2 Regular:1 TTNK3 Premium:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2378175 Date:3/10/2025 Site Name/ID:7-ELEVEN #29514, MKT 1606 Address:309 EAST 400 SOUTH State ID 4001444 City:SALT LAKE CITY State:UT Zip:84111 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #29514, MKT 1606 7-ELEVEN, INC. 309 EAST 400 SOUTH State ID 4001444 SALT LAKE CITY UT 84111 4001444 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 03/10/2025 1 2 3 RUL2 RUL PUL VR350 VR350 VR350 12033 12033 12033 96 96 96 81 81 81 1.5 1.5 1.5 UT151 David Mathie Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2378175 Site ID / Name:29514 / 7-ELEVEN #29514, MKT 1606 Address:309 EAST 400 SOUTH State ID 4001444 City:SALT LAKE CITY State:UT Zip:84111 W.O.# NW1-2378175 +AAE- I10100 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 MAR 10, 2025 11:22 AM SOFTWARE REVISION LEVEL VERSION 333.04 SOFTWARE+ACM- 346333-100-E CREATED - 13.06.07.08.25 S-MODULE+ACM- 330160-162-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV +AAMAAQ- I11B00 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SERVICE NOTICE SESSION REPORT START TIME END TIME MAR 10, 2025 9:11 AM MAR 10, 2025 11:12 AM +AAMAAQ- I20100 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 RU2 SOUTH 3904 3923 7920 33.36 0.00 52.74 2 RUL MIDDLE 8026 8067 3754 60.49 0.00 52.42 3 PUL 2457 2467 9576 24.75 0.00 54.25 +AAMAAQ-9999FF1B+AAMAAQ- I20600 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 TANK ALARM HISTORY TANK 1 RU2 SOUTH HIGH WATER ALARM MAR 10, 2025 10:32 AM OVERFILL ALARM MAR 10, 2025 10:37 AM LOW PRODUCT ALARM APR 23, 2024 2:35 PM INVALID FUEL LEVEL MAR 10, 2025 10:29 AM APR 23, 2024 8:00 PM HIGH WATER WARNING MAR 10, 2025 10:32 AM DELIVERY NEEDED APR 23, 2024 7:31 AM LOW TEMP WARNING MAR 10, 2025 10:41 AM TANK 2 RUL MIDDLE HIGH WATER ALARM MAR 10, 2025 10:33 AM OVERFILL ALARM MAR 10, 2025 10:38 AM INVALID FUEL LEVEL MAR 10, 2025 10:29 AM HIGH WATER WARNING MAR 10, 2025 10:33 AM DELIVERY NEEDED MAR 10, 2025 10:30 AM LOW TEMP WARNING MAR 10, 2025 10:42 AM TANK 3 PUL HIGH WATER ALARM MAR 10, 2025 10:34 AM OVERFILL ALARM MAR 10, 2025 10:38 AM HIGH WATER WARNING MAR 10, 2025 10:34 AM DELIVERY NEEDED FEB 22, 2025 12:20 PM DEC 31, 2024 1:12 PM NOV 9, 2024 6:38 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 +AAMAAQ- I20700 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 TANK LEAK TEST HISTORY T 1:RU2 SOUTH LAST GROSS TEST PASSED: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 10, 2025 9:04 AM 3931 32.7 STANDARD LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 10, 2025 7:08 AM 29 7173 59.6 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 23, 2025 7:58 AM 27 5970 49.6 CSLD FEB 21, 2025 5:48 PM 28 8737 72.6 CSLD MAR 1, 2025 4:05 AM 26 8231 68.4 CSLD APR 30, 2024 12:02 AM 25 6961 57.9 CSLD MAY 2, 2024 1:14 AM 27 7113 59.1 CSLD JUN 27, 2024 5:42 AM 28 6808 56.6 CSLD JUL 31, 2024 4:32 AM 26 6684 55.6 CSLD AUG 4, 2024 6:03 AM 28 6763 56.2 CSLD SEP 14, 2024 6:29 AM 25 5654 47.0 CSLD OCT 31, 2024 6:19 AM 27 6720 55.8 CSLD NOV 7, 2024 4:51 AM 25 6902 57.4 CSLD DEC 24, 2024 7:55 AM 28 6006 49.9 CSLD TANK LEAK TEST HISTORY T 2:RUL MIDDLE LAST GROSS TEST PASSED: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 10, 2025 9:29 AM 8088 67.2 STANDARD LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 10, 2025 10:13 AM 37 8667 72.0 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 28, 2025 10:36 AM 36 7514 62.4 CSLD FEB 18, 2025 7:35 PM 39 10068 83.7 CSLD MAR 1, 2025 1:54 AM 32 9357 77.8 CSLD APR 5, 2024 5:36 AM 12 8203 68.2 CSLD MAY 20, 2024 3:51 PM 33 8143 67.7 CSLD JUN 1, 2024 12:13 AM 35 6356 52.8 CSLD JUL 6, 2024 9:21 AM 36 7747 64.4 CSLD AUG 31, 2024 10:24 PM 34 6626 55.1 CSLD SEP 2, 2024 1:45 PM 33 6900 57.3 CSLD OCT 22, 2024 11:19 PM 32 8061 67.0 CSLD NOV 29, 2024 8:56 AM 41 7286 60.6 CSLD DEC 1, 2024 2:17 AM 35 7240 60.2 CSLD TANK LEAK TEST HISTORY T 3:PUL LAST GROSS TEST PASSED: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 10, 2025 9:04 AM 2467 20.5 STANDARD LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE MAR 10, 2025 7:07 AM 29 2300 19.1 CSLD FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME +ACU- VOLUME TEST TYPE JAN 31, 2025 6:12 AM 30 3352 27.9 CSLD FEB 1, 2025 3:48 AM 28 3392 28.2 CSLD MAR 10, 2025 7:07 AM 29 2300 19.1 CSLD APR 30, 2024 6:36 AM 33 4625 38.4 CSLD MAY 6, 2024 7:37 AM 27 4799 39.9 CSLD JUN 27, 2024 5:41 AM 27 4555 37.9 CSLD JUL 10, 2024 5:39 AM 29 4672 38.8 CSLD AUG 1, 2024 6:22 AM 26 3472 28.9 CSLD SEP 4, 2024 5:33 AM 27 3209 26.7 CSLD OCT 14, 2024 7:23 AM 25 3413 28.4 CSLD NOV 1, 2024 7:15 AM 29 3072 25.5 CSLD DEC 15, 2024 1:35 AM 29 3746 31.1 CSLD +AAMAAQ- I38200 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:RU2 MAR 10, 2025 10:10 AM PLLD SHUTDOWN ALARM MAR 10, 2025 10:10 AM GROSS LINE FAIL Q 2:RUL MAR 10, 2025 10:14 AM PLLD SHUTDOWN ALARM MAR 10, 2025 10:14 AM GROSS LINE FAIL Q 3:PUL MAR 10, 2025 10:11 AM PLLD SHUTDOWN ALARM MAR 10, 2025 10:11 AM GROSS LINE FAIL +AAMAAQ- I37400 MAR 10, 2025 11:22 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 PRESSURE LINE LEAK TEST HISTORY Q 1:RU2 LAST 3.0 PASS: MAR 10, 2025 11:19 AM FIRST 0.10 PASS EACH MONTH: JAN 10, 2002 4:08 AM FIRST 0.20 PASS EACH MONTH: MAR 4, 2025 2:35 AM FEB 2, 2025 2:55 AM JAN 3, 2025 7:29 AM DEC 2, 2024 7:27 PM NOV 2, 2024 9:30 PM OCT 1, 2024 1:33 AM SEP 3, 2024 6:43 AM AUG 4, 2024 3:20 AM JUL 1, 2024 3:47 AM JUN 1, 2024 1:26 AM MAY 2, 2024 3:21 AM APR 3, 2024 11:58 PM Q 2:RUL LAST 3.0 PASS: MAR 10, 2025 11:19 AM FIRST 0.10 PASS EACH MONTH: FIRST 0.20 PASS EACH MONTH: MAR 4, 2025 1:33 PM FEB 4, 2025 12:52 PM JAN 3, 2025 10:15 AM DEC 4, 2024 1:59 PM NOV 2, 2024 11:21 AM OCT 3, 2024 2:21 AM SEP 1, 2024 1:51 AM AUG 4, 2024 11:28 AM JUL 3, 2024 11:41 AM JUN 2, 2024 12:05 AM MAY 4, 2024 1:37 AM APR 3, 2024 2:24 PM Q 3:PUL LAST 3.0 PASS: MAR 10, 2025 11:20 AM FIRST 0.10 PASS EACH MONTH: FIRST 0.20 PASS EACH MONTH: MAR 4, 2025 2:34 AM FEB 2, 2025 2:54 AM JAN 3, 2025 8:26 AM DEC 2, 2024 2:48 AM NOV 2, 2024 2:24 AM OCT 1, 2024 4:32 PM SEP 1, 2024 6:58 PM AUG 2, 2024 1:25 AM JUL 1, 2024 6:56 PM JUN 1, 2024 9:23 PM MAY 2, 2024 3:06 AM APR 3, 2024 11:57 PM +AAMAAQ- IA0100 MAR 10, 2025 11:23 AM TYPE CODE LENGTH SERIAL NO. D/CODE TANK 1 RU2 SOUTH MAG C000 96.00 494709 2404 TANK 2 RUL MIDDLE MAG C000 96.00 494711 2404 TANK 3 PUL MAG C000 96.00 494710 2404 +AAMAAQ- 931 TANK 1 SETUP CONDITIONS PRODUCT: RU2 SOUTH PRODUCT CODE 1 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10829 HIGH PRODUCT LIMIT: 11431 LOW PRODUCT: 900 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 3 TANK FULL CAPACITY: 12033 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 97.90 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 932 TANK 2 SETUP CONDITIONS PRODUCT: RUL MIDDLE PRODUCT CODE 2 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10829 HIGH PRODUCT LIMIT: 11431 LOW PRODUCT: 900 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 3 TANK FULL CAPACITY: 12033 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 96.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- 933 TANK 3 SETUP CONDITIONS PRODUCT: PUL PRODUCT CODE 3 HIGH WATER LIMIT 1.5 OVERFILL LIMIT: 10829 HIGH PRODUCT LIMIT: 11431 LOW PRODUCT: 900 SUDDEN LOSS LIMIT: 25 LEAK LIMIT: 15 THERMAL COEFF: 0.000690 DELIVERY DELAY: 3 TANK FULL CAPACITY: 12033 0 0 0 0 3/4 HEIGHT CAPACITY: 0 0 0 0 0 1/2 HEIGHT CAPACITY: 0 0 0 0 0 1/4 HEIGHT CAPACITY: 0 0 0 0 0 TANK DIAMETER: 96.00 TANK TILT ADDER: 0.00 MANIFOLDED TANKS: NONE TANK CONFIGURED: NO +AAMAAQ- I62A00 MAR 10, 2025 11:23 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 RU2 SOUTH 6016 2 RUL MIDDLE 6016 3 PUL 6016 4 0 +AAMAAQ- I63600 MAR 10, 2025 11:23 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 RU2 SOUTH 3008 2 RUL MIDDLE 3008 3 PUL 3008 4 0 +AAMAAQ- I61100 MAR 10, 2025 11:23 AM LEAK TEST METHOD - - - - - - - - - - - - TEST CSLD : ALL TANK Pd +AD0- 95+ACU- CLIMATE FACTOR:EXTREME EVAP COMP: NO GROSS TEST AUTO-CONFIRM: ENABLED REPORT ONLY: DISABLED TST EARLY STOP:DISABLED +AAMAAQ- I78000 MAR 10, 2025 11:23 AM PRESSURE LINE LEAK SETUP Q 1:RU2 TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 200 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 5 PSI T 1:RU2 SOUTH DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:RUL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 300 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 5 PSI T 2:RUL MIDDLE DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET:-2.0PSI MECHANICAL BLENDER: NO Q 3:PUL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 250 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: DISABLED SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 5 PSI T 3:PUL DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO +AAMAAQ- I7BD00 MAR 10, 2025 11:23 AM PRESSURE LLD SETUP REPORT Q 1:RU2 - NO ALARM ASSIGNMENTS - Q 2:RUL - NO ALARM ASSIGNMENTS - Q 3:PUL - NO ALARM ASSIGNMENTS - +AAMAAQ- I10200 MAR 10, 2025 11:23 AM 164529 7-11 29514 309 E. 400 S. SLC UT 84111 A0672021605001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163737 164000 2 PLLD SENSOR BD 3946 3920 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 PLLD POWER BD 100808 100770 10 UNUSED 15000000 15000000 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 ELEC DISP INT. 101354 101331 COMM 2 UNUSED 15000000 15000000 COMM 3 SERIAL SAT BD 486375 487446 COMM 4 UNUSED 15000000 15000000 COMM 5 RS485 SERIAL BD 15000000 69173 COMM 6 MT COMM BOARD 15000000 411065 +AAM-