Loading...
HomeMy WebLinkAboutDERR-2025-001757Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 11/26/2024 Tanknology WO#NW1-2377989 Test Purpose COMPLIANCE Customer PO# Customer Location SAIA, INC. 11465 JOHNS CREEK PARKWAY SUITE 330 JOHNS CREEK, GA 30097 SLC 794 S 6400 W Salt Lake City, UT 84104 Attn: ANDREA DALTON-LAY Attn: (678) 232-3691 () Test / Inspection Description Item Tested Date Tested Result Precision Line Tightness (.1 GPH) Tank VR3 TNK2 Line 1 Low Sulfur Diesel 11/26/2024 Pass Precision Line Tightness (.1 GPH) Satellite Line 1 11/26/2024 Tested w/ Primary Precision Line Tightness (.1 GPH) Satellite Line 2 11/26/2024 Tested w/ Primary Impact Valve Inspection See test report for details 11/26/2024 Pass RP 1200 ATG See test report for details 11/26/2024 Pass RP 1200 Sensors See test report for details 11/26/2024 Pass Regulatory Annual Inspn. 11/26/2024 P Tanknology Representative: Antonette Shockley Technician: David Mathie Telephone: ()Technician Certification: (See forms) Product Line Tightness Test Page 1 of 1 Work Order: 2377989 Date: 11/26/2024 Site Name/ID: SLC / SLC Address: 794 S 6400 W City: Salt Lake City State: UT Zip: 84104 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 3 Line # 1 TLD-1 VR3 TNK2 Low Sulfur Diesel Pressure 60 12:09 13:09 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Product Line Tightness Test Satellite Line Tightness Test Page 1 of 1 Work Order: 2377989 Date: 11/26/2024 Site Name/ID: SLC / SLC Address: 794 S 6400 W City: Salt Lake City State: UT Zip: 84104 Satellite Line # Fueling From - To Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Sat # 1 1 - 1S Low Sulfur Diesel Pressure Included with primary line test Sat # 2 2 - 2S Low Sulfur Diesel Pressure Included with primary line test Sat # Sat # Sat # Sat # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:2377989 Date:11/26/2024 Site Name/ID:SLC Address:794 S 6400 W City:Salt Lake City State:UT Zip:84104 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/ 40 Pass Fail Not Tested 1S/ 40 Pass Fail Not Tested 2/ 40 Pass Fail Not Tested 2S/ 40 Pass Fail Not Tested 3/ DEF Pass Fail Not Tested NA 4/ DEF Pass Fail Not Tested NA Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com SLC SAIA, INC. 794 S 6400 W Salt Lake City UT 84104 SLC Tanknology, Inc. 11465 JOHNS CREEK PARKWAY SUITE 330 JOHNS CREEK GA 30097 678-232-3691 800-964-1250 11/26/2024 VR2 TK1 VR3 TK2 DSL DSL 450 PLUS 450 PLUS 20048 20048 119.75 119.75 UT151 AST David Mathie 794 S 6400 W SLC 794 S 6400 W, Salt Lake City, UT 84104 SLC Tanknology, Inc. SAIA, INC. 11465 JOHNS CREEK PARKWAY SUITE 330 JOHNS CREEK, GA 30097 678-232-3691 11/26/2024 ANNULAR ANNULAR TRANS SUMP UDC UDC UDC UDC DSL DSL DSL 1 1S 2 2S UT151 David Mathie 794 S 6400 W SLC 794 S 6400 W, Salt Lake City, UT 84104 SLC Tanknology, Inc. SAIA, INC. 11465 JOHNS CREEK PARKWAY SUITE 330 JOHNS CREEK, GA 30097 678-232-3691 11/26/2024 UDC UEC 3 DEF 4 DEF UT151 David Mathie Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2377989 Site ID / Name:SLC / SLC Address:794 S 6400 W City:Salt Lake City State:UT Zip:84104 SAIA SLC 11/26/2024 754 S 6400 W SLC 5 1 DSL VR2 ✔DW ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ NA NA NA ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔✔ ✔ ✔ ✔ SAIA SLC 11/26/2024 754 S 6400 W SLC 5 2 DSL VR3 ✔DW ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ NA NA NA ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔✔ ✔ ✔ ✔ AST Annual Visual Inspection Checklist (Revised 05/11/2023) Facility ID#: Facility Name: Inspection Date: Street Address: City: ZIP: # of Tanks Inspected: Tank ID Numbers: Any item marked “No” requires additional information to describe the condition and date the condition is corrected. ITEM STATUS COMMENTS / DATE CORRECTED Containment 1 Is the containment structure in satisfactory condition (diking, impounding, double-wall tank, etc.)? Yes No 2 Are the drainage pipes/valves in good working condition for continued service? Yes No N/A Tank Foundation/Supports 3 Free of tank settlement or foundation washout? Yes No 4 Concrete pad or ring wall free of cracking or spalling? Yes No 5 Tank supports in satisfactory condition? Yes No 6 Is water able to drain away from tank? Yes No 7 Is the grounding strap between the tank and foundation/supports in good condition? Yes No N/A Cathodic Protection 8 Are cathodic protection system in operating condition and functional? Yes No N/A 9 Rectifier reading Volts: ________ Amps: _______ Are these readings within manufacturer specifications? Yes No N/A Tank External Coating 10 Free of visible signs of paint failure? Yes No Tank Shell / Heads 11 Free of noticeable shell/head distortions, buckling, denting, or bulging? Yes No 12 Free of visible signs of shell/head corrosion or cracking? Yes No Tank Manways, Piping, and Equipment 13 Flanged connection bolts tight and fully engaged with no sign of wear or corrosion? Yes No N/A Tank Roof 14 Free of standing water on roof? Yes No 15 Free of visible signs of coating cracking, crazing, peeling, or blistering? Yes No 16 Free of holes? Yes No AST Annual Visual Inspection Form Page 1 of 2 ITEM STATUS COMMENTS/DATE CORRECTED Venting 17 Normal and emergency vents free of obstructions? Yes No 18 Normal vent on tanks storing gasoline equipped with pressure/vacuum vent cap? Yes No N/A 19 Is the emergency vent in good working condition and functional, and tested as required by manufacturer? Yes No Insulated Tanks 20 Free of missing insulation? Yes No N/A 21 Insulation free of noticeable areas of moisture? Yes No N/A 22 Insulation free of mold? Yes No N/A 23 Insulation free of visible signs of damage? Yes No N/A 24 Insulation adequately protected from water intrusion? Yes No N/A Level and Overfill Prevention Equipment 25 Electronic or mechanical liquid level gauge tested for proper operation? Yes No N/A 26 Electronic or mechanical liquid level gauge calibrated during the previous 12 months? Yes No N/A 27 Is overfill prevention equipment in good working condition? Overfill Valve Audible Alarm Both Yes No N/A Verified by: Inspection Date: Operational? Yes No Repair Date: 28 Is tank ullage being determined and documented before filling the tank? Yes No N/A Electrical Equipment 29 Is tank/equipment grounding adequate and in good condition? Yes No 30 Is electrical wiring for control boxes, lights, and other high voltage equipment in good condition? Yes No N/A Additional Comments Inspector Information (Certified Individual or Professional Engineer) Printed Name: Signature: Date: AST Annual Visual Inspection Form Page 2 of 2 AST Annual Visual Inspection Checklist (Revised 05/11/2023) Facility ID#: Facility Name: Inspection Date: Street Address: City: ZIP: # of Tanks Inspected: Tank ID Numbers: Any item marked “No” requires additional information to describe the condition and date the condition is corrected. ITEM STATUS COMMENTS / DATE CORRECTED Containment 1 Is the containment structure in satisfactory condition (diking, impounding, double-wall tank, etc.)? Yes No 2 Are the drainage pipes/valves in good working condition for continued service? Yes No N/A Tank Foundation/Supports 3 Free of tank settlement or foundation washout? Yes No 4 Concrete pad or ring wall free of cracking or spalling? Yes No 5 Tank supports in satisfactory condition? Yes No 6 Is water able to drain away from tank? Yes No 7 Is the grounding strap between the tank and foundation/supports in good condition? Yes No N/A Cathodic Protection 8 Are cathodic protection system in operating condition and functional? Yes No N/A 9 Rectifier reading Volts: ________ Amps: _______ Are these readings within manufacturer specifications? Yes No N/A Tank External Coating 10 Free of visible signs of paint failure? Yes No Tank Shell / Heads 11 Free of noticeable shell/head distortions, buckling, denting, or bulging? Yes No 12 Free of visible signs of shell/head corrosion or cracking? Yes No Tank Manways, Piping, and Equipment 13 Flanged connection bolts tight and fully engaged with no sign of wear or corrosion? Yes No N/A Tank Roof 14 Free of standing water on roof? Yes No 15 Free of visible signs of coating cracking, crazing, peeling, or blistering? Yes No 16 Free of holes? Yes No AST Annual Visual Inspection Form Page 1 of 2 ITEM STATUS COMMENTS/DATE CORRECTED Venting 17 Normal and emergency vents free of obstructions? Yes No 18 Normal vent on tanks storing gasoline equipped with pressure/vacuum vent cap? Yes No N/A 19 Is the emergency vent in good working condition and functional, and tested as required by manufacturer? Yes No Insulated Tanks 20 Free of missing insulation? Yes No N/A 21 Insulation free of noticeable areas of moisture? Yes No N/A 22 Insulation free of mold? Yes No N/A 23 Insulation free of visible signs of damage? Yes No N/A 24 Insulation adequately protected from water intrusion? Yes No N/A Level and Overfill Prevention Equipment 25 Electronic or mechanical liquid level gauge tested for proper operation? Yes No N/A 26 Electronic or mechanical liquid level gauge calibrated during the previous 12 months? Yes No N/A 27 Is overfill prevention equipment in good working condition? Overfill Valve Audible Alarm Both Yes No N/A Verified by: Inspection Date: Operational? Yes No Repair Date: 28 Is tank ullage being determined and documented before filling the tank? Yes No N/A Electrical Equipment 29 Is tank/equipment grounding adequate and in good condition? Yes No 30 Is electrical wiring for control boxes, lights, and other high voltage equipment in good condition? Yes No N/A Additional Comments Inspector Information (Certified Individual or Professional Engineer) Printed Name: Signature: Date: AST Annual Visual Inspection Form Page 2 of 2 SAIA SLC 11/26/2024 754 S 6400 W SLC 5 5 USED COOLANT SHOP ✔DW ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ NA NA NA ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ DM 11/26/2024 ✔ ✔ ✔ ✔ REMOTE HLA FILL IN SHOP W.O.# NW1-2377989 +AAE- I10100 11/26/24 1:50 PM SAIA 794 S 6400 W SLC UT 84104 SYSTEM STATUS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME ALL FUNCTIONS NORMAL +AAMAAQ- I90200 11/26/24 1:50 PM SOFTWARE REVISION LEVEL VERSION 33.50 SOFTWARE+ACM- 342005-010-D- CREATED - 22.03.16.16.31 +AAMAAQ-9999FF1B+AAMAAQ- I20100 11/26/24 1:50 PM SAIA 794 S 6400 W SLC UT 84104 IN-TANK INVENTORY TANK PRODUCT VOLUME TC-VOLUME ULLAGE HEIGHT WATER TEMP 1 DEF 3131 3126 1467 90.30 70.35 2 North Tank 14121 14168 5927 79.45 0.00 52.65 3 South Tank 14334 14381 5714 80.51 0.00 52.68 +AAMAAQ- I30100 11/26/24 1:50 PM SAIA 794 S 6400 W SLC UT 84104 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 Pump 2 Satellite Normal 2 Pump 2 Main Normal 3 Pump 1 Satellite Normal 4 Pump 3 DEF Normal 5 Transitional Sump Normal 6 Pump 1 Main Normal 7 Pump 4 DEF Normal 8 South Tank Int Normal 9 North Tank Int Normal +AAMAAQ- I30200 11/26/24 1:50 PM SAIA 794 S 6400 W SLC UT 84104 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 Pump 2 Satellite 11/26/24 1:20 PM FUEL ALARM 06/12/22 11:28 PM FUEL ALARM 2 Pump 2 Main 11/26/24 1:20 PM FUEL ALARM 11/25/23 2:45 PM FUEL ALARM 11/11/23 9:11 AM FUEL ALARM 06/12/22 11:25 PM FUEL ALARM 3 Pump 1 Satellite 11/26/24 1:19 PM FUEL ALARM 11/02/23 10:28 AM SENSOR OUT ALARM 06/12/22 11:31 PM FUEL ALARM 4 Pump 3 DEF 11/26/24 1:27 PM FUEL ALARM 01/22/24 2:28 PM FUEL ALARM 06/12/22 11:30 PM FUEL ALARM 5 Transitional Sump 11/26/24 1:28 PM FUEL ALARM 08/20/24 5:36 PM FUEL ALARM 11/12/23 6:50 PM FUEL ALARM 11/06/23 10:36 AM FUEL ALARM 06/12/22 11:32 PM FUEL ALARM 6 Pump 1 Main 11/26/24 1:20 PM FUEL ALARM 03/16/24 12:58 AM FUEL ALARM 06/12/22 11:29 PM FUEL ALARM 7 Pump 4 DEF 11/26/24 1:21 PM FUEL ALARM 11/03/23 11:40 AM FUEL ALARM 06/12/22 11:27 PM FUEL ALARM 8 South Tank Int 11/26/24 1:15 PM FUEL ALARM 11/19/24 6:06 AM FUEL ALARM 11/16/24 9:46 PM FUEL ALARM 06/12/22 11:12 PM FUEL ALARM 06/12/22 10:37 PM FUEL ALARM 9 North Tank Int 11/26/24 1:11 PM FUEL ALARM 11/02/23 2:16 PM FUEL ALARM 06/12/22 10:15 PM FUEL ALARM +AAMAAQ- I11100 11/26/24 1:50 PM SAIA 794 S 6400 W SLC UT 84104 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 5 PIPE SUMP Transitional Sump FUEL ALARM CLEAR 11-26-24 01:37PM L 4 CONT. SMP Pump 3 DEF FUEL ALARM CLEAR 11-26-24 01:36PM L 3 CONT. SMP Pump 1 Satellite FUEL ALARM CLEAR 11-26-24 01:34PM L 6 CONT. SMP Pump 1 Main FUEL ALARM CLEAR 11-26-24 01:33PM L 2 CONT. SMP Pump 2 Main FUEL ALARM CLEAR 11-26-24 01:33PM L 1 CONT. SMP Pump 2 Satellite FUEL ALARM CLEAR 11-26-24 01:32PM L 7 CONT. SMP Pump 4 DEF FUEL ALARM CLEAR 11-26-24 01:32PM L 5 PIPE SUMP Transitional Sump FUEL ALARM ALARM 11-26-24 01:28PM L 4 CONT. SMP Pump 3 DEF FUEL ALARM ALARM 11-26-24 01:27PM L 7 CONT. SMP Pump 4 DEF FUEL ALARM ALARM 11-26-24 01:21PM L 2 CONT. SMP Pump 2 Main FUEL ALARM ALARM 11-26-24 01:20PM L 1 CONT. SMP Pump 2 Satellite FUEL ALARM ALARM 11-26-24 01:20PM L 6 CONT. SMP Pump 1 Main FUEL ALARM ALARM 11-26-24 01:20PM L 3 CONT. SMP Pump 1 Satellite FUEL ALARM ALARM 11-26-24 01:19PM L 8 ANNULAR South Tank Int FUEL ALARM CLEAR 11-26-24 01:19PM L 8 ANNULAR South Tank Int FUEL ALARM ALARM 11-26-24 01:15PM L 9 ANNULAR North Tank Int FUEL ALARM CLEAR 11-26-24 01:15PM L 9 ANNULAR North Tank Int FUEL ALARM ALARM 11-26-24 01:11PM L 8 ANNULAR South Tank Int FUEL ALARM CLEAR 11-19-24 09:57AM L 8 ANNULAR South Tank Int FUEL ALARM ALARM 11-19-24 06:06AM L 8 ANNULAR South Tank Int FUEL ALARM CLEAR 11-17-24 04:44AM L 8 ANNULAR South Tank Int FUEL ALARM ALARM 11-16-24 09:46PM L 5 PIPE SUMP Transitional Sump FUEL ALARM CLEAR 09-09-24 10:08AM P 1 Printer PAPER OUT CLEAR 08-23-24 02:49PM P 1 Printer PAPER OUT ALARM 08-23-24 02:47PM L 5 PIPE SUMP Transitional Sump FUEL ALARM ALARM 08-20-24 05:36PM T 1 Tank DEF PROBE OUT CLEAR 07-14-24 09:51AM T 1 Tank DEF PROBE OUT ALARM 07-04-24 05:16PM T 1 Tank DEF OVERFILL ALARM CLEAR 06-20-24 06:06PM T 1 Tank DEF OVERFILL ALARM ALARM 06-20-24 06:00PM L 4 CONT. SMP Pump 3 DEF FUEL ALARM CLEAR 06-03-24 02:26PM L 6 CONT. SMP Pump 1 Main FUEL ALARM CLEAR 06-03-24 10:29AM T 2 Tank North Tank OVERFILL ALARM CLEAR 06-01-24 12:46AM T 2 Tank North Tank OVERFILL ALARM ALARM 06-01-24 12:38AM T 1 Tank DEF OVERFILL ALARM CLEAR 04-11-24 10:45AM T 1 Tank DEF OVERFILL ALARM ALARM 04-11-24 10:39AM L 6 CONT. SMP Pump 1 Main FUEL ALARM ALARM 03-16-24 12:58AM T 2 Tank North Tank PROBE OUT CLEAR 01-30-24 07:00PM T 2 Tank North Tank PROBE OUT ALARM 01-30-24 06:56PM T 2 Tank North Tank LOW PRODUCT ALARM CLEAR 01-30-24 06:54PM T 2 Tank North Tank LOW PRODUCT ALARM ALARM 01-30-24 06:54PM T 2 Tank North Tank LOW PRODUCT ALARM CLEAR 01-30-24 06:53PM T 2 Tank North Tank LOW PRODUCT ALARM ALARM 01-30-24 06:53PM L 4 CONT. SMP Pump 3 DEF FUEL ALARM ALARM 01-22-24 02:28PM L 2 CONT. SMP Pump 2 Main FUEL ALARM CLEAR 11-27-23 11:18AM L 2 CONT. SMP Pump 2 Main FUEL ALARM ALARM 11-25-23 02:45PM L 2 CONT. SMP Pump 2 Main FUEL ALARM CLEAR 11-17-23 09:27AM L 5 PIPE SUMP Transitional Sump FUEL ALARM CLEAR 11-17-23 09:08AM L 5 PIPE SUMP Transitional Sump FUEL ALARM ALARM 11-12-23 06:50PM L 2 CONT. SMP Pump 2 Main FUEL ALARM ALARM 11-11-23 09:11AM +AAMAAQ- I11F00 11/26/24 1:51 PM SAIA 794 S 6400 W SLC UT 84104 Sensor Status Report - All Sensors +ACM- Sensor Location Status L 1 Pump 2 Satellite NORMAL L 2 Pump 2 Main NORMAL L 3 Pump 1 Satellite NORMAL L 4 Pump 3 DEF NORMAL L 5 Transitional Sump NORMAL L 6 Pump 1 Main NORMAL L 7 Pump 4 DEF NORMAL L 8 South Tank Int NORMAL L 9 North Tank Int NORMAL +AAMAAQ- I11F00 11/26/24 1:52 PM SAIA 794 S 6400 W SLC UT 84104 Selected Range: All Records: Sensor Status History Report - All Sensors +ACM- Sensor Location Status Active Clear L 1 Pump 2 Satellite FUEL ALARM 11/26/24 1:20P 11/26/24 1:32P L 1 Pump 2 Satellite FUEL ALARM 06/12/22 11:28P 06/12/22 11:32P L 2 Pump 2 Main FUEL ALARM 11/26/24 1:20P 11/26/24 1:33P L 2 Pump 2 Main FUEL ALARM 11/25/23 2:45P 11/27/23 11:18A L 2 Pump 2 Main FUEL ALARM 11/11/23 9:11A 11/17/23 9:27A L 2 Pump 2 Main FUEL ALARM 06/12/22 11:25P 06/12/22 11:29P L 3 Pump 1 Satellite FUEL ALARM 11/26/24 1:19P 11/26/24 1:34P L 3 Pump 1 Satellite SENSOR OUT ALARM 11/02/23 10:28A 11/02/23 10:32A L 3 Pump 1 Satellite FUEL ALARM 06/12/22 11:31P 06/12/22 11:35P L 4 Pump 3 DEF FUEL ALARM 11/26/24 1:27P 11/26/24 1:36P L 4 Pump 3 DEF FUEL ALARM 01/22/24 2:28P 06/03/24 2:26P L 4 Pump 3 DEF FUEL ALARM 06/12/22 11:30P 06/12/22 11:33P L 5 Transitional Sump FUEL ALARM 11/26/24 1:28P 11/26/24 1:37P L 5 Transitional Sump FUEL ALARM 08/20/24 5:36P 09/09/24 10:08A L 5 Transitional Sump FUEL ALARM 11/12/23 6:50P 11/17/23 9:08A L 5 Transitional Sump FUEL ALARM 11/06/23 10:36A 11/08/23 11:40A L 5 Transitional Sump FUEL ALARM 06/12/22 11:32P 06/12/22 11:35P L 6 Pump 1 Main FUEL ALARM 11/26/24 1:20P 11/26/24 1:33P L 6 Pump 1 Main FUEL ALARM 03/16/24 12:58A 06/03/24 10:29A L 6 Pump 1 Main FUEL ALARM 06/12/22 11:29P 06/12/22 11:33P L 7 Pump 4 DEF FUEL ALARM 11/26/24 1:21P 11/26/24 1:32P L 7 Pump 4 DEF FUEL ALARM 11/03/23 11:40A 11/08/23 12:42P L 7 Pump 4 DEF FUEL ALARM 06/12/22 11:27P 06/12/22 11:30P L 8 South Tank Int FUEL ALARM 11/26/24 1:15P 11/26/24 1:19P L 8 South Tank Int FUEL ALARM 11/19/24 6:06A 11/19/24 9:57A L 8 South Tank Int FUEL ALARM 11/16/24 9:46P 11/17/24 4:44A L 8 South Tank Int FUEL ALARM 06/12/22 11:12P 11/02/23 4:12P L 8 South Tank Int FUEL ALARM 06/12/22 10:37P 06/12/22 10:46P L 9 North Tank Int FUEL ALARM 11/26/24 1:11P 11/26/24 1:15P L 9 North Tank Int FUEL ALARM 11/02/23 2:16P 11/02/23 2:22P L 9 North Tank Int FUEL ALARM 06/12/22 10:15P 11/02/23 12:59P +AAMAAQ- I20600 11/26/24 1:52 PM SAIA 794 S 6400 W SLC UT 84104 TANK ALARM HISTORY TANK 1 DEF SETUP DATA WARNING 11/02/23 12:57 PM 11/02/23 12:35 PM OVERFILL ALARM 06/20/24 6:00 PM 04/11/24 10:39 AM LOW PRODUCT ALARM 11/02/23 1:33 PM INVALID FUEL LEVEL 11/02/23 12:57 PM 11/02/23 12:35 PM PROBE OUT 07/04/24 5:16 PM 11/06/23 11:11 AM DELIVERY NEEDED 11/02/23 1:33 PM TANK 2 North Tank SETUP DATA WARNING 11/07/23 10:13 AM OVERFILL ALARM 06/01/24 12:38 AM LOW PRODUCT ALARM 01/30/24 6:54 PM 01/30/24 6:53 PM PROBE OUT 01/30/24 6:56 PM DELIVERY NEEDED 11/25/24 7:52 PM 11/02/24 5:51 AM 10/10/24 6:05 PM TANK 3 South Tank SETUP DATA WARNING 11/07/23 10:13 AM DELIVERY NEEDED 11/25/24 10:37 PM 11/03/24 8:58 PM 10/10/24 7:06 PM +AAMAAQ- I6SU00 11/26/24 1:52 PM -------------------------------------------------------- +ACoAKgAq- SETUP FOR ALL TANKS +ACoAKgAq- -------------------------------------------------------- ULLAGE DISPLAY MODE: FULL ULLAGE FULL ULLAGE LABEL: ULLAGE USER ULLAGE: DISABLED PRINT TC VOLUMES: ENABLED TC REFERENCE TEMPERATURE: 60 DEG F PERIODIC TEST NEEDED WARNINGS: DISABLED DAYS BEFORE PERIODIC WARNING: 25 DAYS BEFORE PERIODIC ALARM: 30 ANNUAL TEST NEEDED WARNINGS: DISABLED DAYS BEFORE ANNUAL WARNING: 355 DAYS BEFORE ANNUAL ALARM: 365 TC DENSITY: DISABLED STICK HEIGHT: DISABLED LEAK TEST REPORT FORMAT: STANDARD LEAK TEST REGION: EPA -------------------------------------------------------- +ACoAKgAq- TANK SETUP +ACoAKgAq- -------------------------------------------------------- --- GENERAL SETUP - TANK 1 --- CONFIGURED: ENABLED LABEL: DEF PRODUCT CODE: 3 PROBE NUMBER: Pb 1: DEF Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 4599 GALLONS DIAMETER: 132.6 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000160 METER DATA PRESENT: DISABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 1 --- MAX VOLUME: 4599 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 25+ACU- LOW PRODUCT: 486 GALLONS HIGH WATER WARNING: 2.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 99 GALLONS SUDDEN LOSS LIMIT: 100 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 1 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 1 --- TANK PROFILE: LINEAR FULL VOLUME: 4599 --- TANK 1 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: LINEAR SOURCE: USER ENTERED LAST CHANGE: 2023-11-02 STATUS: ACTIVE CAPACITY: 4599 ENDSHAPE: 0.000 OFFSET: 0.00 TILT: 0.00 DIAMETER: 132.60 --- TANK 1 --- T1 SIPHON MANIFOLDED TO TANKS: NONE T1 LINE MANIFOLDED TO TANKS: NONE --- HRM - TANK 1 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 2 --- CONFIGURED: ENABLED LABEL: North Tank PRODUCT CODE: 2 PROBE NUMBER: Pb 2: North Tank PROBE OFFSET: 0.00 INCHES FULL VOLUME: 20048 GALLONS DIAMETER: 119.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: DISABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 2 --- MAX VOLUME: 20048 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 25+ACU- LOW PRODUCT: 1500 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 4.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 99 GALLONS SUDDEN LOSS LIMIT: 100 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 2 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 2 --- TANK PROFILE: ONE POINT --- TANK 2 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: ONE POINT SOURCE: USER ENTERED LAST CHANGE: 2023-11-07 STATUS: ACTIVE CAPACITY: 20048 ENDSHAPE: 0.000 OFFSET: 0.00 TILT: 0.00 DIAMETER: 119.75 --- TANK 2 --- T2 SIPHON MANIFOLDED TO TANKS: NONE T2 LINE MANIFOLDED TO TANKS: NONE --- HRM - TANK 2 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 3 --- CONFIGURED: ENABLED LABEL: South Tank PRODUCT CODE: 3 PROBE NUMBER: Pb 3: South Tank Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 20048 GALLONS DIAMETER: 119.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: DISABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 3 --- MAX VOLUME: 20048 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 25+ACU- LOW PRODUCT: 1500 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 4.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 99 GALLONS SUDDEN LOSS LIMIT: 100 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 3 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 3 --- TANK PROFILE: ONE POINT --- TANK 3 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: ONE POINT SOURCE: USER ENTERED LAST CHANGE: 2023-11-07 STATUS: ACTIVE CAPACITY: 20048 ENDSHAPE: 0.000 OFFSET: 0.00 TILT: 0.00 DIAMETER: 119.75 --- TANK 3 --- T3 SIPHON MANIFOLDED TO TANKS: NONE T3 LINE MANIFOLDED TO TANKS: NONE --- HRM - TANK 3 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS +AAMAAQ- I70300 11/26/24 1:52 PM LIQUID MODEL SENSOR LABEL MODEL 1 Pump 2 Satellite Tri-State(Single Float) 2 Pump 2 Main Tri-State(Single Float) 3 Pump 1 Satellite Tri-State(Single Float) 4 Pump 3 DEF Tri-State(Single Float) 5 Transitional Sump Tri-State(Single Float) 6 Pump 1 Main Tri-State(Single Float) 7 Pump 4 DEF Tri-State(Single Float) 8 South Tank Int Tri-State(Single Float) 9 North Tank Int Tri-State(Single Float) 10 Tri-State(Single Float) 11 Tri-State(Single Float) 12 Tri-State(Single Float) 13 Tri-State(Single Float) 14 Tri-State(Single Float) 15 Tri-State(Single Float) 16 Tri-State(Single Float) 17 Tri-State(Single Float) 18 Tri-State(Single Float) 19 Tri-State(Single Float) 20 Tri-State(Single Float) 21 Tri-State(Single Float) 22 Tri-State(Single Float) 23 Tri-State(Single Float) 24 Tri-State(Single Float) 25 Tri-State(Single Float) 26 Tri-State(Single Float) 27 Tri-State(Single Float) 28 Tri-State(Single Float) 29 Tri-State(Single Float) 30 Tri-State(Single Float) 31 Tri-State(Single Float) 32 Tri-State(Single Float) 33 Tri-State(Single Float) 34 Tri-State(Single Float) 35 Tri-State(Single Float) 36 Tri-State(Single Float) 37 Tri-State(Single Float) 38 Tri-State(Single Float) 39 Tri-State(Single Float) 40 Tri-State(Single Float) 41 Tri-State(Single Float) 42 Tri-State(Single Float) 43 Tri-State(Single Float) 44 Tri-State(Single Float) 45 Tri-State(Single Float) 46 Tri-State(Single Float) 47 Tri-State(Single Float) 48 Tri-State(Single Float) 49 Tri-State(Single Float) 50 Tri-State(Single Float) 51 Tri-State(Single Float) 52 Tri-State(Single Float) 53 Tri-State(Single Float) 54 Tri-State(Single Float) 55 Tri-State(Single Float) 56 Tri-State(Single Float) 57 Tri-State(Single Float) 58 Tri-State(Single Float) 59 Tri-State(Single Float) 60 Tri-State(Single Float) 61 Tri-State(Single Float) 62 Tri-State(Single Float) 63 Tri-State(Single Float) 64 Tri-State(Single Float) 65 Tri-State(Single Float) 66 Tri-State(Single Float) 67 Tri-State(Single Float) 68 Tri-State(Single Float) 69 Tri-State(Single Float) 70 Tri-State(Single Float) 71 Tri-State(Single Float) 72 Tri-State(Single Float) 73 Tri-State(Single Float) 74 Tri-State(Single Float) 75 Tri-State(Single Float) 76 Tri-State(Single Float) 77 Tri-State(Single Float) 78 Tri-State(Single Float) 79 Tri-State(Single Float) 80 Tri-State(Single Float) 81 Tri-State(Single Float) 82 Tri-State(Single Float) 83 Tri-State(Single Float) 84 Tri-State(Single Float) 85 Tri-State(Single Float) 86 Tri-State(Single Float) 87 Tri-State(Single Float) 88 Tri-State(Single Float) 89 Tri-State(Single Float) 90 Tri-State(Single Float) 91 Tri-State(Single Float) 92 Tri-State(Single Float) 93 Tri-State(Single Float) 94 Tri-State(Single Float) 95 Tri-State(Single Float) 96 Tri-State(Single Float) 97 Tri-State(Single Float) 98 Tri-State(Single Float) 99 Tri-State(Single Float) +AAMAAQ- I5P500 11/26/24 1:52 PM AUTOMATIC EVENTS - DEVICE TASKS REPORT Event ID - 0002 EVENT - OVERFILL ALARM : ALL TANKS ACTION - DEVICE - R 1 : Overfill Alarm ------ +AAM- W.O.# NW1-2377989 OVF