HomeMy WebLinkAboutDAQ-2025-0013591 DAQC-206-25 Site ID 10354 (B4) MEMORANDUM TO: STACK TEST FILE – UNIVERSITY OF UTAH THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Robert Sirrine, Environmental Scientist DATE: February 21, 2025 SUBJECT: Location: Building 303, University of Utah, Salt Lake County, UT Contact: Bryan Cracroft, 801-585-1617 Tester: Alliance Technical Group, Ryan Lyons Source: Boilers 6-7, 9, and Turbine Cogen Unit with WHR Unit FRS Site ID#: UT0000004903500063 Permit# Title V operating permit 3500063004, dated August 25, 2023 Action Code: TR Subject: Review of Stack Test Report received February 11, 2025 On February 11, 2025, the DAQ received a test report for the University of Utah boilers 6-7, 9, and Turbine Cogen with a WHR Unit at the High Temperature Water Plant, Building 303 located at the University of Utah, in Salt Lake City, UT. The testing was performed on January 13-16, 2025, to demonstrate compliance with the NOX and CO emission limits found in Title V operating permit Conditions II.B.3.a and II.B.4.a. The DAQ- calculated test results are: Source Test Date RM/Pollutant DAQ Result Test Result Limit Boiler 6 1/15/25 7/NOX 0.14 lbs/hr 0.14 lbs/hr 0.54 lbs/hr 6.9 ppmdv** 6.86 ppmdv** 9.0 ppmdv** Boiler 7 1/15/25 7/NOX 0.19 lbs/hr 0.19 lbs/hr 0.54 lbs/hr 8.2 ppmdv** 8.21 ppmdv** 9.0 ppmdv** Boiler 9 1/16/25 7/NOX 0.02 lbs/hr 0.017 lbs/hr 0.79 lbs/hr 8.2 ppmdv** 8.16 ppmdv** 9.0 ppmdv** Turbine 1/14/25 7/NOX 1.21 lb/hr 1.2 lb/hr 2.65 lb/hr 5 ppmdv* 4.60 ppmdv* 9 ppmdv* 10/CO 0.16 lb/hr 0.16 lb/hr 4.48 lb/hr 1 ppmdv* 1.02 ppmdv* 25 ppmdv* Turbine & 1/13/25 7/NOX 5.71 lb/hr 5.7 lb/hr 8.97 lb/hr WHRU 11 ppmdv* 11.22 ppmdv* 15 ppmdv* 10/CO 4.29 lb/hr 4.3 lb/hr 10.84 lb/hr 14 ppmdv* 13.83 ppmdv* 30 ppmdv* ** ppmdv @ 3% O2 * ppmdv @ 15% O2 * - / $ - - $ ) 2 DEVIATIONS: None noted. CONCLUSION: The stack test report appears to be acceptable. RECOMMENDATION: Building 303 Boilers 6-7, 9, and Cogen Turbine alone and with the WHRU should be considered to be in Compliance with the CO and NOx emission limits at the time of testing. No further action is recommended. HPV: No. ATTACHMENTS: Stack test report received February 11, 2025 DAQ generated Excel spreadsheets U of U Bldg 303 Boiler 6 2025 rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Facilities Company Contact:Bryon Cracroft Contact Phone No.801-585-1617 Stack Designation:Bldg 303 Boiler 6 Test & Review Dates Test Date:1/15/2025 Review Date: 2/19/2025 Observer:none Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 0.54 0.14 ppm 9 6.86 Percent %O2 Correction as a whole #3.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 32.00 5.585 25.13 Contractor Information Contact: Ryon Lyons Contracting Company: Alliance Technical Group Address: 3683 W 2270 S Suite E, West Valley City Ut Phone No.: 708-214-4850 Project No.:Enter Diluent Used 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes U of U Bldg 303 Boiler 6 2025 rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Facilities Bldg 303 Boiler 6 Average Emission Dry SO2 NOX CO lbs./MMbtu 0.008 Average % concentration lbs./hr. 0.14 CO2 O2 ppm corrected for %O2 6.86 4.10 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)8.33E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 7.690E-07 lbs./hr.0.14 #VALUE! 4.10 ppm corrected for %O2 6.86 4.11 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.#VALUE! #VALUE! ppm corrected for %O2 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.#VALUE! #VALUE! ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU U of U Bldg 303 Boiler 6 2025 rev Calibration Error Test Test Date January 15, 2025 O2 CS - Cal. Span 19.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 19.00 19.06 0.06 0.32% Passed Cal. High-level 19.00 19.06 0.06 0.32% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 100.00% out of range 100% of Cal. Span High-level 100.00% Test Date CO2 CS - Cal. Span Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 15, 2025 NOx CS - Cal. Span 9.50 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 9.50 9.40 0.10 1.053% Passed Cal. High-level 9.50 9.40 0.10 1.053% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 100.00% out of range 100% of Cal. Span High-level 100.00% Test Date CO CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level U of U Bldg 303 Boiler 6 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 6 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 9.50 19.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 9.40 19.06 Low-Level 0.00% 0.00% ppmdv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0 TRUE TRUE 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.00 TRUE TRUE 0.00 Pass or Failed Invalid Run Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/15/2025 SO2 SO2 NOX CO CO2 O2 NOX 6.4 4.1 CO 0.0% 67.1% 0.0% 0.0% 21.6%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE TRUE 0.00% Drift Difference TRUE 0.0 TRUE TRUE 0.0 3% of Span Pass or Re-Calibrate Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Re-Calibrate Pass Pass NOTE These cells scans for th Cdir gas after the Cmentered. If this scan is incorrec Cdir to the correct gas Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog U of U Bldg 303 Boiler 6 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 6 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 9.50 19.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 9.40 19.06 Low-Level 0.00% 0.00% ppmdv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0 TRUE TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0 TRUE TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. Failed Bias Dialog Failed Cal Error Dialog U of U Bldg 303 Boiler 6 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 6 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 Low-Level 0.00% 0.00% ppmv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Failed Cal Error Dialog U of U Bldg 303 Boiler 7 2025 rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Facilities Company Contact:Bryon Cracroft Contact Phone No.801-585-1617 Stack Designation:Bldg 303 Boiler 7 Test & Review Dates Test Date:1/15/2025 Review Date: 2/19/2020 Observer:none Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 0.54 0.19 ppm 9 8.21 Percent %O2 Correction as a whole #3.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 32.00 5.585 25.13 Contractor Information Contact: Ryon Lyons Contracting Company: Alliance Technical Group Address: 3683 W 2270 S Suite E, West Valley City Ut Phone No.: 708-214-4850 Project No.:Enter Diluent Used 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes U of U Bldg 303 Boiler 7 2025 rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Facilities Bldg 303 Boiler 7 Average Emission Dry SO2 NOX CO lbs./MMbtu 0.010 Average % concentration lbs./hr. 0.19 CO2 O2 ppm corrected for %O2 8.21 4.35 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)9.97E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 9.066E-07 lbs./hr.0.19 #VALUE! 4.35 ppm corrected for %O2 8.21 4.36 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.#VALUE! #VALUE! ppm corrected for %O2 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.#VALUE! #VALUE! ppm corrected for %O2 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU U of U Bldg 303 Boiler 7 2025 rev Calibration Error Test Test Date January 15, 2025 O2 CS - Cal. Span 19.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 19.00 19.06 0.06 0.32% Passed Cal. High-level 19.00 19.06 0.06 0.32% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 100.00% out of range 100% of Cal. Span High-level 100.00% Test Date CO2 CS - Cal. Span Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 15, 2025 NOx CS - Cal. Span 9.50 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 9.50 9.40 0.10 1.053% Passed Cal. High-level 9.50 9.40 0.10 1.053% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 100.00% out of range 100% of Cal. Span High-level 100.00% Test Date CO CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level U of U Bldg 303 Boiler 7 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 7 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 9.50 19.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 9.40 19.06 Low-Level 0.00% 0.00% ppmdv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0 TRUE TRUE 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.00 TRUE TRUE 0.00 Pass or Failed Invalid Run Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/15/2025 SO2 SO2 NOX CO CO2 O2 NOX 7.5 4.4 CO 0.0% 79.1% 0.0% 0.0% 22.9%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE TRUE 0.00% Drift Difference TRUE 0.0 TRUE TRUE 0.0 3% of Span Pass or Re-Calibrate Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Re-Calibrate Pass Pass NOTE These cells scans for th Cdir gas after the Cmentered. If this scan is incorrec Cdir to the correct gas Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog U of U Bldg 303 Boiler 7 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 7 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 9.50 19.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 9.40 19.06 Low-Level 0.00% 0.00% ppmdv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0 TRUE TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0 TRUE TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. Failed Bias Dialog Failed Cal Error Dialog U of U Bldg 303 Boiler 7 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 7 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 Low-Level 0.00% 0.00% ppmv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Failed Cal Error Dialog U of U Bldg 303 Boiler 9 2025 rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Facilities Company Contact:Bryon Cracroft Contact Phone No.801-585-1617 Stack Designation:Bldg 303 Boiler 9 Test & Review Dates Test Date:1/16/2025 Review Date: 2/21/2025 Observer:none Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 0.79 0.02 ppm 9 8.16 Percent %O2 Correction as a whole #3.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 35.00 6.681 25.13 Contractor Information Contact: Ryon Lyons Contracting Company: Alliance Technical Group Address: 3683 W 2270 S Suite E, West Valley City Ut Phone No.: 708-214-4850 Project No.:Enter Diluent Used 8710 Round Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes U of U Bldg 303 Boiler 9 2025 rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Facilities Bldg 303 Boiler 9 Average Emission Dry SO2 NOX CO lbs./MMbtu 0.010 Average % concentration lbs./hr. 0.02 CO2 O2 ppm corrected for %O2 8.16 3.52 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)9.91E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 9.464E-07 lbs./hr.0.02 #VALUE! 3.52 ppm corrected for %O2 8.16 3.53 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.#VALUE! #VALUE! ppm corrected for %O2 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.#VALUE! #VALUE! ppm corrected for %O2 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU U of U Bldg 303 Boiler 9 2025 rev Calibration Error Test Test Date January 16, 2025 O2 CS - Cal. Span 19.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 19.00 19.06 0.06 0.32% Passed Cal. High-level 19.00 19.06 0.06 0.32% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 100.00% out of range 100% of Cal. Span High-level 100.00% Test Date CO2 CS - Cal. Span Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 16, 2025 NOx CS - Cal. Span 9.50 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 9.50 9.40 0.10 1.053% Passed Cal. High-level 9.50 9.40 0.10 1.053% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 100.00% out of range 100% of Cal. Span High-level 100.00% Test Date CO CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level U of U Bldg 303 Boiler 9 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 9 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 9.50 19.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 9.40 19.06 Low-Level 0.00% 0.00% ppmdv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0 TRUE TRUE 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.00 TRUE TRUE 0.00 Pass or Failed Invalid Run Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/16/2025 SO2 SO2 NOX CO CO2 O2 NOX 7.84 3.53 CO 0.0% 82.5% 0.0% 0.0% 18.6%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% TRUE TRUE 0.00% Drift Difference TRUE 0.0 TRUE TRUE 0.0 3% of Span Pass or Re-Calibrate Pass Pass Up-scale Gas Drift TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0.0 TRUE TRUE 0.0 Pass or Re-Calibrate Pass Pass NOTE These cells scans for th Cdir gas after the Cmentered. If this scan is incorrec Cdir to the correct gas Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog U of U Bldg 303 Boiler 9 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 9 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 9.50 19.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 9.40 19.06 Low-Level 0.00% 0.00% ppmdv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmdv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% TRUE TRUE 0.00%± 5% of Span Difference TRUE 0 TRUE TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. CM - Up-scale Gas 9.40 19.06 SBi - Up-Scale Bias TRUE 0.00% TRUE TRUE 0.00% Difference TRUE 0 TRUE TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. Failed Bias Dialog Failed Cal Error Dialog U of U Bldg 303 Boiler 9 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Boiler 9 CS Calibration Span 9.50 19.00 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.50 19.00 High-Level 9.50 19.00 0 to 20% of Cal. Span 0.00% 0.00% 40 to 60% of Cal. Span 100.0% 100.0% 100% of Cal. Span 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 Mid-Level 9.40 19.06 High-Level 9.40 19.06 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 Low-Level 0.00% 0.00% ppmv Difference 0 0 Status Passed Cal.Passed Cal. Mid-Level 1.05% 0.32% ppmv Difference 0.1 0.06 Status Passed Cal.Passed Cal. High-Level 1.05% 0.32% ppmv Difference 0.1 0.06 Status Passed Cal.Passed Cal. Failed Cal Error Dialog U of U Bldg 303 Turbine 2025 rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Facilities Company Contact:Bryon Cracroft Contact Phone No.801-585-1617 Stack Designation:Bldg 303 Solar Taurus 70 Cogen Turbine Test & Review Dates Test Date:1/14/2025 Review Date: 2/19/2025 Observer:none Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 2.65 4.48 1.21 0.16 ppm 9 25 4.60 1.02 Percent %O2 Correction as a whole #15.00 15.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 53.00 15.321 25.15 Contractor Information Contact: Ryon Lyons Contracting Company: Alliance Technical Group Address: 3683 W 2270 S Suite E, West Valley City Ut Phone No.: 708-214-4850 Project No.:Enter Diluent Used 8710 Round Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes U of U Bldg 303 Turbine 2025 rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Facilities Bldg 303 Solar Taurus 70 Cogen Turbine Average Emission Dry SO2 NOX CO lbs./MMbtu 0.017 0.002 Average % concentration lbs./hr. 1.21 0.16 CO2 O2 ppm corrected for %O2 4.60 1.02 2.99 15.51 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.63E-02 2.72E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.893E-07 8.132E-08 lbs./hr.1.17 0.20 2.98 15.45 ppm corrected for %O2 4.44 1.21 3.01 15.44 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.69E-02 2.27E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 4.923E-07 6.594E-08 lbs./hr.1.20 0.16 2.98 15.60 ppm corrected for %O2 4.59 1.01 3.01 15.60 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)1.76E-02 1.89E-03 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 5.259E-07 5.654E-08 lbs./hr.1.24 0.13 3.01 15.47 ppm corrected for %O2 4.78 0.844 3.04 15.42 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU U of U Bldg 303 Turbine 2025 rev Calibration Error Test Test Date January 14, 2025 O2 CS - Cal. Span 24.03 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 12.00 12.03 0.03 0.12% Passed Cal. High-level 24.03 24.08 0.05 0.21% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 49.94% 100% of Cal. Span High-level 100.00% Test Date January 14, 2025 CO2 CS - Cal. Span 10.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 5.00 5.00 0.00 0.000% Passed Cal. High-level 10.00 10.02 0.02 0.200% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 14, 2025 NOx CS - Cal. Span 30.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.01 0.01 0.033% Passed Cal. Mid-level 15.00 14.99 0.01 0.033% Passed Cal. High-level 30.00 29.96 0.04 0.133% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date January 14, 2025 CO 4.48 CS - Cal. Span 30.00 25 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 -0.02 0.02 0.067% Passed Cal. Mid-level 15.00 14.99 0.01 0.033% Passed Cal. High-level 30.00 30.01 0.01 0.033% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% U of U Bldg 303 Turbine 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Solar Taurus 70 Cogen Turbine CS Calibration Span 30.00 30.00 10.00 24.03 Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 15.00 15.00 5.00 12.00 High-Level 30.00 30.00 10.00 24.03 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 50.0% 49.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 15.00 15.00 5.00 12.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.01 -0.02 0.00 0.00 Mid-Level 14.99 14.99 5.00 12.03 High-Level 29.96 30.01 10.02 24.08 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 14.99 14.99 5.00 12.03 Low-Level 0.03% 0.07% 0.00% 0.00% ppmdv Difference 0.01 0.02 0 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.03% 0.00% 0.12% ppmdv Difference 0.01 0.01 0 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.13% 0.03% 0.20% 0.21% ppmdv Difference 0.04 0.01 0.02 0.05 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.01 -0.01 0.01 0.03 System Bias. SBi - Zero Bias TRUE 0.00% 0.03% 0.10% 0.12%± 5% of Span Difference TRUE 0 0.01 0.01 0.03 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.97 15.01 5.03 11.97 SBi - Up-Scale Bias TRUE 0.07% 0.07% 0.30% 0.25% Difference TRUE 0.02 0.02 0.03 0.06 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/14/2025 SO2 SO2 NOX CO CO2 O2 NOX 4.1 1.07 3.0 15.4 CO 0.0% 13.6% 3.6% 30.1% 64.3%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level -0.02 -0.09 0.05 0.00 System Bias. SBi - Zero Bias TRUE 0.10% 0.23% 0.50% 0.00%± 5% of Span Difference TRUE 0.0 0.1 0.1 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.94 14.93 5.02 12.02 SBi - Up-Scale Bias TRUE 0.17% 0.20% 0.20% 0.04% Difference TRUE 0.1 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.10% 0.20% 0.40% 0.12% Drift Difference TRUE 0.0 0.1 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.10% 0.13% 0.10% 0.21% Difference TRUE 0.0 0.1 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass NOTE These cells scans for th Cdir gas after the Cmentered. If this scan is incorrec Cdir to the correct gas Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog U of U Bldg 303 Turbine 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Solar Taurus 70 Cogen Turbine CS Calibration Span 30.00 30.00 10.00 24.03 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 15.00 15.00 5.00 12.00 High-Level 30.00 30.00 10.00 24.03 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 50.0% 49.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 15.00 5.00 12.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.01 -0.02 0.00 0.00 Mid-Level 14.99 14.99 5.00 12.03 High-Level 29.96 30.01 10.02 24.08 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 14.99 14.99 5.00 12.03 Low-Level 0.03% 0.07% 0.00% 0.00% ppmdv Difference 0.01 0.02 0 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.03% 0.00% 0.12% ppmdv Difference 0.01 0.01 0 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.13% 0.03% 0.20% 0.21% ppmdv Difference 0.04 0.01 0.02 0.05 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level -0.02 -0.09 0.05 0.00 System Bias. SBi - Zero Bias TRUE 0.10% 0.23% 0.50% 0.00%± 5% of Span Difference TRUE 0.03 0.07 0.05 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.94 14.93 5.02 12.02 SBi - Up-Scale Bias TRUE 0.17% 0.20% 0.20% 0.04% Difference TRUE 0.05 0.06 0.02 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/14/2025 SO2 SO2 NOX CO CO2 O2 NOX 4.1 0.79 3.0 15.6 CO 0.0% 13.6% 2.6% 30.1% 64.9%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level -0.02 -0.15 0.05 0.13 System Bias. SBi - Zero Bias TRUE 0.10% 0.43% 0.50% 0.54%± 5% of Span Difference TRUE 0.0 0.1 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.94 14.93 5.01 12.01 SBi - Up-Scale Bias TRUE 0.17% 0.20% 0.10% 0.08% Difference TRUE 0.1 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.20% 0.00% 0.54% Response Spec. Difference TRUE 0.0 0.1 0.0 0.1 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.00% 0.00% 0.10% 0.04% Difference TRUE 0.0 0.0 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog U of U Bldg 303 Turbine 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 Bldg 303 Solar Taurus 70 Cogen Turbine CS Calibration Span 30.00 30.00 10.00 24.03 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 15.00 15.00 5.00 12.00 High-Level 30.00 30.00 10.00 24.03 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 50.0% 49.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 15.00 5.00 12.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.01 -0.02 0.00 0.00 Mid-Level 14.99 14.99 5.00 12.03 High-Level 29.96 30.01 10.02 24.08 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 14.99 14.99 5.00 12.03 Low-Level 0.03% 0.07% 0.00% 0.00% ppmv Difference 0.01 0.02 0 0 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.03% 0.03% 0.00% 0.12% ppmv Difference 0.01 0.01 0 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.13% 0.03% 0.20% 0.21% ppmv Difference 0.04 0.01 0.02 0.05 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level -0.02 -0.15 0.05 0.13 System Bias. SBi - Zero Bias TRUE 0.10% 0.43% 0.50% 0.54%± 5% of Span Difference TRUE 0.03 0.13 0.05 0.13 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.94 14.93 5.01 12.01 SBi - Up-Scale Bias TRUE 0.17% 0.20% 0.10% 0.08% Difference TRUE 0.05 0.06 0.01 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/14/2025 SO2 SO2 NOX CO CO2 O2 NOX 4.4 0.67 3.0 15.4 CO 0.0% 14.6% 2.2% 30.4% 64.2%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level -0.02 -0.07 0.07 0.14 System Bias. SBi - Zero Bias TRUE 0.10% 0.17% 0.70% 0.58%± 5% of Span Difference TRUE 0.0 0.1 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 15.07 14.94 5.01 11.98 SBi - Up-Scale Bias TRUE 0.27% 0.17% 0.10% 0.21% Difference TRUE 0.1 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.27% 0.20% 0.04% Response Spec. Difference TRUE 0.0 0.1 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.10% 0.03% 0.00% 0.12% Difference TRUE 0.1 0.0 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog U of U Bldg 303 Turbine plus WRHU 2025 rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name University of Utah Facilities Company Contact:Bryon Cracroft Contact Phone No.801-585-1617 Stack Designation:Bldg 303 Solar Taurus 70 Cogen Turbine Plus WHRU Test & Review Dates Test Date:1/13/2025 Review Date: 2/19/2025 Observer:none Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./MMBtu lbs./hr. 8.97 10.84 5.71 4.29 ppm 9 30 11.22 13.83 Percent %O2 Correction as a whole #15.00 15.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 53.00 15.321 25.13 Contractor Information Contact: Ryon Lyons Contracting Company: Alliance Technical Group Address: 3683 W 2270 S Suite E, West Valley City Ut Phone No.: 708-214-4850 Project No.:Enter Diluent Used 8710 Round Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes U of U Bldg 303 Turbine plus WRHU 2025 rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification University of Utah Facilities Bldg 303 Solar Taurus 70 Cogen Turbine Plus WHRU Average Emission Dry SO2 NOX CO lbs./MMbtu 0.041 0.031 Average % concentration lbs./hr. 5.71 4.29 CO2 O2 ppm corrected for %O2 11.22 13.83 5.62 10.67 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)4.06E-02 3.08E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 2.277E-06 1.728E-06 lbs./hr.5.66 4.30 5.65 10.69 ppm corrected for %O2 11.02 13.74 5.65 10.72 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)4.15E-02 3.13E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 2.332E-06 1.758E-06 lbs./hr.5.74 4.33 5.60 10.67 ppm corrected for %O2 11.26 13.95 5.65 10.68 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)4.19E-02 3.10E-02 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 2.362E-06 1.744E-06 lbs./hr.5.73 4.23 5.60 10.64 ppm corrected for %O2 11.38 13.802 5.60 10.67 Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU U of U Bldg 303 Turbine plus WRHU 2025 rev Calibration Error Test Test Date January 13, 2025 O2 CS - Cal. Span 24.03 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.01 0.01 0.04% Passed Cal. Mid-level 12.00 12.03 0.03 0.12% Passed Cal. High-level 24.03 24.04 0.01 0.04% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 49.94% 100% of Cal. Span High-level 100.00% Test Date January 13, 2025 CO2 CS - Cal. Span 10.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 5.00 5.02 0.02 0.200% Passed Cal. High-level 10.00 10.03 0.03 0.300% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date January 13, 2025 NOx CS - Cal. Span 30.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 15.00 14.95 0.05 0.167% Passed Cal. High-level 30.00 30.03 0.03 0.100% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date January 13, 2025 CO 10.84 CS - Cal. Span 30.00 30 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.03 0.03 0.100% Passed Cal. Mid-level 15.00 14.98 0.02 0.067% Passed Cal. High-level 30.00 29.93 0.07 0.233% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% U of U Bldg 303 Turbine plus WRHU 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 dg 303 Solar Taurus 70 Cogen Turbine Plus WHR CS Calibration Span 30.00 30.00 10.00 24.03 Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 15.00 15.00 5.00 12.00 High-Level 30.00 30.00 10.00 24.03 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 50.0% 49.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 15.00 15.00 5.00 12.00 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.03 0.00 0.01 Mid-Level 14.95 14.98 5.02 12.03 High-Level 30.03 29.93 10.03 24.04 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 14.95 14.98 5.02 12.03 Low-Level 0.00% 0.10% 0.00% 0.04% ppmdv Difference 0 0.03 0 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.17% 0.07% 0.20% 0.12% ppmdv Difference 0.05 0.02 0.02 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.10% 0.23% 0.30% 0.04% ppmdv Difference 0.03 0.07 0.03 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.02 0.00 0.02 System Bias. SBi - Zero Bias TRUE 0.00% 0.03% 0.00% 0.04%± 5% of Span Difference TRUE 0 0.01 0 0.01 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.94 15.02 5.01 12.05 SBi - Up-Scale Bias TRUE 0.03% 0.13% 0.10% 0.08% Difference TRUE 0.01 0.04 0.01 0.02 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/13/2025 SO2 SO2 NOX CO CO2 O2 NOX 19.0 23.75 5.7 10.7 CO 0.0% 63.3% 79.2% 56.5% 44.6%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.03 -0.03 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.10% 0.20% 0.00% 0.04%± 5% of Span Difference TRUE 0.0 0.1 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.95 14.95 4.99 12.01 SBi - Up-Scale Bias TRUE 0.00% 0.10% 0.30% 0.08% Difference TRUE 0.0 0.0 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.10% 0.17% 0.00% 0.00% Drift Difference TRUE 0.0 0.1 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.03% 0.03% 0.20% 0.00% Difference TRUE 0.0 0.1 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass NOTE These cells scans for th Cdir gas after the Cmentered. If this scan is incorrec Cdir to the correct gas Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog U of U Bldg 303 Turbine plus WRHU 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 g 303 Solar Taurus 70 Cogen Turbine Plus WH CS Calibration Span 30.00 30.00 10.00 24.03 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 15.00 15.00 5.00 12.00 High-Level 30.00 30.00 10.00 24.03 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 50.0% 49.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 15.00 5.00 12.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.03 0.00 0.01 Mid-Level 14.95 14.98 5.02 12.03 High-Level 30.03 29.93 10.03 24.04 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 14.95 14.98 5.02 12.03 Low-Level 0.00% 0.10% 0.00% 0.04% ppmdv Difference 0 0.03 0 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.17% 0.07% 0.20% 0.12% ppmdv Difference 0.05 0.02 0.02 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.10% 0.23% 0.30% 0.04% ppmdv Difference 0.03 0.07 0.03 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.03 -0.03 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.10% 0.20% 0.00% 0.04%± 5% of Span Difference TRUE 0.03 0.06 0 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.95 14.95 4.99 12.01 SBi - Up-Scale Bias TRUE 0.00% 0.10% 0.30% 0.08% Difference TRUE 0 0.03 0.03 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/13/2025 SO2 SO2 NOX CO CO2 O2 NOX 19.5 24.17 5.6 10.7 CO 0.0% 64.9% 80.6% 55.9% 44.4%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.06 -0.17 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.20% 0.67% 0.40% 0.04%± 5% of Span Difference TRUE 0.1 0.2 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.99 14.97 5.00 12.01 SBi - Up-Scale Bias TRUE 0.13% 0.03% 0.20% 0.08% Difference TRUE 0.0 0.0 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.10% 0.47% 0.40% 0.00% Response Spec. Difference TRUE 0.0 0.1 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.13% 0.07% 0.10% 0.00% Difference TRUE 0.0 0.0 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog U of U Bldg 303 Turbine plus WRHU 2025 rev Division of Air Quality Stack Test Review of University of Utah Facilities SO2 NOX CO CO2 O2 g 303 Solar Taurus 70 Cogen Turbine Plus WH CS Calibration Span 30.00 30.00 10.00 24.03 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2 Low-Level 0.00 0.00 0.00 0.00 Mid-Level 15.00 15.00 5.00 12.00 High-Level 30.00 30.00 10.00 24.03 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 50.0% 50.0% 50.0% 49.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 15.00 15.00 5.00 12.00 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2 Low-Level 0.00 0.03 0.00 0.01 Mid-Level 14.95 14.98 5.02 12.03 High-Level 30.03 29.93 10.03 24.04 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 14.95 14.98 5.02 12.03 Low-Level 0.00% 0.10% 0.00% 0.04% ppmv Difference 0 0.03 0 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.17% 0.07% 0.20% 0.12% ppmv Difference 0.05 0.02 0.02 0.03 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.10% 0.23% 0.30% 0.04% ppmv Difference 0.03 0.07 0.03 0.01 Status Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.06 -0.17 0.04 0.00 System Bias. SBi - Zero Bias TRUE 0.20% 0.67% 0.40% 0.04%± 5% of Span Difference TRUE 0.06 0.2 0.04 0.01 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.99 14.97 5.00 12.01 SBi - Up-Scale Bias TRUE 0.13% 0.03% 0.20% 0.08% Difference TRUE 0.04 0.01 0.02 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:1/13/2025 SO2 SO2 NOX CO CO2 O2 NOX 19.7 24.06 5.6 10.7 CO 0.0% 65.7% 80.2% 56.0% 44.4%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.06 -0.06 0.07 0.08 System Bias. SBi - Zero Bias TRUE 0.20% 0.30% 0.70% 0.29%± 5% of Span Difference TRUE 0.1 0.1 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 14.96 15.03 5.01 12.04 SBi - Up-Scale Bias TRUE 0.03% 0.17% 0.10% 0.04% Difference TRUE 0.0 0.0 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.37% 0.30% 0.25% Response Spec. Difference TRUE 0.0 0.1 0.0 0.1 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Up-scale Gas Drift TRUE 0.10% 0.13% 0.10% 0.04% Difference TRUE 0.0 0.1 0.0 0.0 Pass or Re-Calibrate Pass Pass Pass Pass Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog