Loading...
HomeMy WebLinkAboutDDW-2025-002058System Number 18021 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -16,733 Number of other connections - - - 756 ERCs of other connections 4,819 Total Equivalent Residential Connections (ERCs)21,552.0 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 800 11,973.3 400 8,620,800 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >16733 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >100%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.10 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >50.00 2 Irrigation zone 4 3 4 5 6 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 570 6,824.3 285 4,907,958 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 2,500 Maximum fire suppression duration (in hours) for water system or pressure zone 2 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >300,000 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 1,370 18,797.6 685 13,828,758 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 18,797.6 gpm Existing Source Capacity 23,950.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 127.4% MIN. REQUIREMENTS FOR INDOOR WATER USE MINIMUM REQUIREMENTS FOR WATER SYSTEM Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* (Example: water use of 2 factories equals to water use of 55 homes.) Source MIN. REQUIREMENTS FOR IRRIGATION USE System Name Source Taylorsville Bennion Improvement District Storage (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) There are 24 other connections that get irrigation water including parks. Due to the unknown amount of acreage of connections receiving DW for irrigation, the number is estimated at 50. Source (indoor + outdoor) Storage Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Yes No Yes No Enter number of non-residential connections, e.g., 2 industrial connections. Convert "Number of other connections" (Cell E9) to ERCs here. [ERCs of other connections = peak day demand of other connections in gal per day / 800 gpd] Enter estimated irrigated acre Enter total irrigated acres of other connections here. Enter fire flow in gpm. Enter duration in hours. Autolink to 4.2 "Total Existing Source Capacity" cell below. Select Irrigated Zone # from the pick list. See "Irrigation Demands & Map" tab on the bottom of the screen or WaterLink. Less than 100% indicates: (1) additional source capacity is needed, and Autolink to 2 "Total Source" cell above. Source deficit indicates that: (1) additional source capacity is needed, and (2) source deficiency should be assessed. TBID Cap Calculation Page 1 of 2 2/21/2025 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 13,828,758 gal Existing Storage Capacity 55,500,000 gal Storage Capacity Deficit None gal Required Fire Storage 300,000 gal Not Applicable Existing % of Total Req'd 401.3% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person* GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 0 30 0 0.00 0.0 20 0 10 0 0.00 0.0 5 0 2.5 0 0.00 0.0 N/A 100 N/A 50 0.13 0.0 Number of people per camp site Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 7 3.5 8.8 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)23,950 4.1 Projected ERCs Calculation (optional)WS002 Taylosville East Well 900 Total Projected ERCs 16,763 WS003 Barker Well 1800 Existing Residential Connections 16733 WS004 JVWCD Consecutive Conn 3750 Obligated Future ERCs (enter below)30 WS021 Taylosville West Well 2200 WS023 Atheron East Well 1500 WS024 Atheron West Well 3000 WS027 Pioneer Well 3000 WS028 Valley Well 3800 WS026 Rawson Well 2000 WS029 Swensen Well 2000 Maximum ERCs (assuming indoor use only) 43110 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)55,500,000 ST001 Low Zone North #1 500,000 ST002 Low zone north #2 1,000,000 ST003 Low Zone North #3 1,000,000 ST004 Low Zone North #4 1,000,000 ST005 Low Zone South #1 4,500,000 ST006 Low Zone South #2 4,500,000 ST007 Low Zone South #3 4,500,000 ST008 Low Zone South #4 4,500,000 ST009 Middle Zone #1 5,000,000 ST010 Middle Zone #2 4,500,000 ST011 Middle Zone #3 5,000,000 The connection with JVWCD can provide upto 9000 gpm if needed. This is about 3,000 gpm for 3 connection sites. The GPM listed was adjusted to meet the needs of the system. RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Semi-Developed Camp w/ flush toilets Taylorsville Bennion Improvement District Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? Autolink to 4.3 "Total Existing Storage Capcity" cell below. If applicable, enter number of people per camp site here. Storage deficit indicates that: (1) additional storage volume is needed, and (2) storage deficiency should be assessed. Use this number in Cell I8 ("Number of residential connections") on Page 1 to calculate PROJECTED demand & req'ts (including both existing & future connections). Diaphragm or air pressure tanks shall NOT be considered effective storage volume for (1) community systems, or (2) NTNC with significant demand UNLESS an exception has been granted. Autolink to 2 "Total Storage" cell above. If applicable, use this number in cell I8 or cell I9 on Page 1. If NO, answer one of question set 2.01 to 2.05 in ESS. If YES, answer one of question set 2.06 to 2.10 in ESS. Less than 100% indicates: (1) additional storage capacity is needed, and (2) storage deficiency should be assessed. TBID Cap Calculation Page 2 of 2 2/21/2025