HomeMy WebLinkAboutDDW-2025-002012Danielle Zebelean <dzebelean@utah.gov>
Snowbird System Specific Sizing Renewal; System #18031; Project #11587
5 messages
Danielle Zebelean <dzebelean@utah.gov>Fri, Jan 31, 2025 at 1:26 PM
To: Kasey Carpenter <kasey@canyonwater.com>, kaseydc@hotmail.com
Hi Kasey,
While the module is not working for Alta currently, it is for Snowbird! I've pulled the data from 2018-2023. You'll notice that
there is a slight decrease this year due to the fact that we are no longer requiring the use of a variability factor. If you
would like to use one to increase your standards please let me know and I will update the report.
I am trying to get through all my renewals this winter. Let me know if you have any questions or need any changes prior to
February 27, 2025, or I will finalize the standards as is.
Thanks!
Dani Zebelean, P.E.
Environmental Engineer III | Division of Drinking Water
M: (385) 278-5110
Hours: M - Th 7 am to 5 pm
drinkingwater.utah.gov
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA
requirements.
3 attachments
DDW-2022-000316.pdf
318K
18031 11587 2025 DRAFT Water Use.pdf
30K
11587_SNOWBIRD_2025_Water_Use_Manual_V1.xlsx
44K
Kasey Carpenter <kasey@canyonwater.com>Tue, Feb 4, 2025 at 12:44 PM
To: Danielle Zebelean <dzebelean@utah.gov>
Hi Dani,
I have a few questions for you. So the minimum sizing standards just use the maximum from all of the reporting years?
So the Peak Day Source Demand per ERC was 239 gpd in 2020 and 187 gpd in 2023 but 239 is used because it's the
max? Is that the same for ERCs in the Capacity Calculations? I'm just confused why the 2025 draft is saying we have a
source deficiency and using 3,077 as the ERC calculation. The one from 2022 uses the 2020 number of 2,317 for ERCs.
Thanks
Kasey
Quoting Danielle Zebelean <dzebelean@utah.gov>:
3/3/25, 10:19 AM State of Utah Mail - Snowbird System Specific Sizing Renewal; System #18031; Project #11587
https://mail.google.com/mail/u/0/?ik=82c167e5f1&view=pt&search=all&permthid=thread-a:r1566729709683990383&simpl=msg-a:r570247302549885…1/3
Hi Kasey,
While the module is not working for Alta currently, it is for Snowbird!
I've pulled the data from 2018-2023. You'll notice that there is a slight
decrease this year due to the fact that we are no longer requiring the use
of a variability factor. If you would like to use one to increase your
standards please let me know and I will update the report.
I am trying to get through all my renewals this winter. Let me know if you
have any questions or need any changes prior to *February 27, 2025, *or I
will finalize the standards as is.
Thanks!
[image: Division Name] <https://drinkingwater.utah.gov/>
Dani Zebelean, P.E.
Environmental Engineer III | Division of Drinking Water
M: (385) 278-5110
Hours: M - Th 7 am to 5 pm
drinkingwater.utah.gov
<https://fb.com/UtahDEQ> <https://twitter.com/UtahDEQ>
[Quoted text hidden]
--
Kasey Carpenter
Salt Lake County Service Area #3
Danielle Zebelean <dzebelean@utah.gov>Tue, Feb 4, 2025 at 5:40 PM
To: Kasey Carpenter <kasey@canyonwater.com>
Hi Kasey,
Ah sorry I didn't catch that, another bug we are waiting to be fixed. The module should be using your most recent ERC
number not the maximum like in the other categories. Thank you for noticing that I will update the report tomorrow and
send you a new copy!
Thanks!
Dani Zebelean, P.E.
Environmental Engineer III | Division of Drinking Water
M: (385) 278-5110
Hours: M - Th 7 am to 5 pm
drinkingwater.utah.gov
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA
requirements.
[Quoted text hidden]
Danielle Zebelean <dzebelean@utah.gov>Thu, Feb 6, 2025 at 12:20 PM
To: Kasey Carpenter <kasey@canyonwater.com>
Hi Kasey,
Sorry for the delay. Attached is the updated report.
3/3/25, 10:19 AM State of Utah Mail - Snowbird System Specific Sizing Renewal; System #18031; Project #11587
https://mail.google.com/mail/u/0/?ik=82c167e5f1&view=pt&search=all&permthid=thread-a:r1566729709683990383&simpl=msg-a:r570247302549885…2/3
Thanks!
Dani Zebelean, P.E.
Environmental Engineer III | Division of Drinking Water
M: (385) 278-5110
Hours: M - Th 7 am to 5 pm
drinkingwater.utah.gov
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA
requirements.
[Quoted text hidden]
18031 11587 2025 DRAFT Water Use V2.pdf
80K
Kasey Carpenter <kasey@canyonwater.com>Fri, Feb 7, 2025 at 11:46 AM
To: Danielle Zebelean <dzebelean@utah.gov>
Thank you!
Quoting Danielle Zebelean <dzebelean@utah.gov>:
Hi Kasey,
Sorry for the delay. Attached is the updated report.
Thanks!
[image: Division Name] <https://drinkingwater.utah.gov/>
Dani Zebelean, P.E.
Environmental Engineer III | Division of Drinking Water
M: (385) 278-5110
Hours: M - Th 7 am to 5 pm
drinkingwater.utah.gov
<https://fb.com/UtahDEQ> <https://twitter.com/UtahDEQ>
Emails to and from this email address may be considered public records and
thus subject to Utah GRAMA requirements.
On Tue, Feb 4, 2025 at 5:40 PM Danielle Zebelean <dzebelean@utah.gov> wrote:
Hi Kasey,
Ah sorry I didn't catch that, another bug we are waiting to be fixed. The
module should be using your most recent ERC number not the maximum like in
the other categories. Thank you for noticing that I will update the report
tomorrow and send you a new copy!
Thanks!
[Quoted text hidden]
[Quoted text hidden]
3/3/25, 10:19 AM State of Utah Mail - Snowbird System Specific Sizing Renewal; System #18031; Project #11587
https://mail.google.com/mail/u/0/?ik=82c167e5f1&view=pt&search=all&permthid=thread-a:r1566729709683990383&simpl=msg-a:r570247302549885…3/3