Loading...
HomeMy WebLinkAboutDERR-2025-001510FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTIONS ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT P.O. BOX 3360 DES MOINES, IA 50316 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HEADQUARTERS WWW.SENECACO.COM STORE.SENECACO.COM Seneca Account Rep: Phone: Date of Test: Scope of Work: Seneca Job # Customer PO # Technician: Certification:(see test reports attached) Testing Summary Test Summary Description Component Tested Date Tested Result Customer Information Name: Street Address: City: State: Zip: Contact: Phone Number: Site Information Site Name: Testing Summary Street Address: City: State: Zip: Facility No. Field Notes 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HE ADQUARTERS P.O. BOX 3360 DES MOINES, IA 50316 WWW.SENECACO.COM STORE.SENECACO.COM Testing Summary Testing Summary FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTIONS ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT Inspection Date: Site Name: Address: City/State/Zip: Tank Number 1 2 3 4 5 6 7 8 Product: Equipment Manufacturer: List Type of Equipment (automatic, high level alarm, ball float): Drop tube removed from tank? Drop tube and float devices are free of debris? Float moved freely and poppet moves into flow path? Bypass valve in the drop tube (if present) is open and free blockage? Flapper is adjusted to shut off flow at 95% capacity? Electronic device and probe are opening properly? Alarm activates at 90% capacity or within one minutes of overfill? Alarm can be heard from where the tank is fueled? Tank Top fittings are vapor tight and leak free? Ball float cage free of debris? Ball is free of holes and cracks and moves freely in cage? Vent hole in pipe is open and near top of tank? Ball float pipe is proper length to restrict flow at 90% capacity? Pass Pass Pass Pass Pass Pass Pass PasInspection Results (select one) (No to any question indicates a test failure)Fail Fail Fail Fail Fail Fail Fail Fail Inspection Company: Technician: Over Fill Equipment Inspection Automatic Shutoff Device Inspection/Tested per Manufacturer Guidelines Over Fill Alarm Inspection/Tested per Manufactuer Guidelines Ball Float Valve Inspection/Tested per Manufacturer Guidelines Comments: Seneca Companies, Inc. follows the PEI RP 1200 standard for certification of overfill devices 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HEADQUARTERS P.O. BOX 3360 DES MOINES, IA 50316 WWW.SENECACO.COM STORE.SENECACO.COM FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTIONS ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTIONS ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT OPV 3 FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTION ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT Site Name: Site Address: -ob : City: State: =ip: Date: Scope of Work: Arrival Time to Site: Departure Time from Site: DP leak/Sump/SB Cathodic Protection MC/LLD Vapor Recovery Calibration Technician: Post-Test SiJnature: **By signing below, you confirm that the items listed above have been visually verified by you. Site Contact: Post-Test SiJnature: Inspector on site" Yes No If yes, please Jive name: Service TestinJ A.All B.TestinJ Yes No Notes: All shear valves have been set to open (if applicable). TestinJ and Service Environmental Checklist Dispatch Type: 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HEADQUARTERS P.O. BOX 3360 DES MOINES, IA 50316 WWW.SENECACO.COM STORE.SENECACO.COM Testers must upload a copy of this completed form with reports/photos and email to Mark Shirley and Emma Petrowitz.