HomeMy WebLinkAboutDERR-2025-0015091 LHD USE ONLY Date Received Reviewer Date LHD Approved Date mailed to State STATE USE ONLY Date Received Date Mailed to LHD Date Received From LHD Reviewer/Date Approved Mgr. Review/Date PETROLEUM STORAGE TANK CLOSURE PLAN (rev. 10/21) FACILITY ID# 9000324 Closure Plan prepared at the request of the owner/operator (identified below) by Aaron Spackman of (company name) Spackman Enterprises Phone # 801-598-7928 Address PO BOX 1276 City Centerville State UT Zip 84014 A Contractor may prepare this Closure Plan as the owner/operator's agent. In preparing the Closure Plan, the Contractor must act with the owner/operator's knowledge and approval. The owner/operator must sign the Closure Plan. Submit Closure Plan to: DERR/PST, P.O. Box 144840, Salt Lake City, Utah, 84114-4840 This Closure Plan is submitted in compliance with the requirements contained in 40 CFR 280 Subpart G and U.A.C. R311-204. FACILITY INFORMATION Tank Owner Uintah School District Phone # 435-828-3193 Address 826 S 1500 E City Naples State UT Zip 84078 Facility Name Uintah School District Address 210 S 100 W City Vernal State UT Zip 84078 Contact person Donny Laws Phone # Total number of regulated petroleum storage tanks at this site 3 Total number of regulated petroleum storage tanks at this site to be closed 3 Piping closure only Tank # 1 2 3 Tank Type (Steel,FRP,etc.) FRP FRP FRP Piping Type (Steel,FRP,etc.) DWFRP DWFRP DWFRP Date Installed 12/31/1986 12/31/1986 12/31/1986 Capacity 12000 12000 12000 Substance stored* GAS DSL GAS Date last operated Unknown Unknown Unkown Removal/In Place/Change in Service (CIS)? Removal Removal Removal *Indicate the specific substance stored in each tank to be closed (gasoline, diesel, new oil, waste oil, etc.) For waste oil tanks: Have degreasing or other types of solvents been stored or mixed with the waste oil? Yes (identify if known) No Not Known Analysis for lead or other contaminants may be required prior to disposal of contaminated soil or other material. (Check with your disposal facility.) 02/27/2025 Laura Perdue 02/27/2025 2 TANK REMOVER Name Aaron Spackman Cert. # TR 0436 Exp. Date 04/15/25 Company Spackman Enterprises Phone # 801-598-7928 Address PO BOX 1276 City Centerville State UT Zip 84014 SOIL/GROUNDWATER SAMPLER Name Aaron Spackman Cert. # GS 1738 Exp. Date 02/15/25 Company Spackman Enterprises Phone # 801-598-7928 Address PO BOX 1276 City Centerville State UT Zip 84014 Before the closure plan is submitted for approval, the local health and fire departments where the facility is located must be contacted. CONTACT LOCAL HEALTH DISTRICT: Name of Dist. Utah Derr Date 2/26/25 Contact Laura Perdue Title Environmental Inspector Phone# 256-656-2847 CONTACT LOCAL FIRE DEPT. Name of Dept. Uintah Fire District Date 12/26/25 Contact Sam Howard Title Fire Chief Phone# 435-828-6718 DISPOSAL INFORMATION Tank(s) will be disposed at: Facility Uintah County Landfill Address 2801 E 500 N City Vernal State UT Zip 84078 Contact person Scale Phone# 435-789-6018 Product lines will either be: removed or cleaned, secured in place, and capped. Vent lines will either be: removed or cleaned and secured open. Piping will be disposed at: Facility Same Address City State Zip Contact person Phone# Tank(s) will be emptied by: company Sump and Trap Cleaning Phone# 801-595-8151 Tank(s) will be cleaned by: company Sump and Trap Cleaning Phone# 801-595-8151 Contaminated water in the tank/rinsate will be disposed at: Facility Sump and Trap Cleaning Contact person Josh Greenwood Phone# 801-595-8151 Tank(s) will be: purged or rendered inert by the following method: Dry Ice Residual sludges will be disposed at the following facility: Sump and Trap Cleaning Address 618 S 4050 W City Salt Lake City State UT Zip 84104 Contact person Josh Greenwood Phone# 801-595-8151 FOR CLOSURE IN PLACE ONLY For this closure method, you are subject to the requirements of UAC R315-302-2(6), which requires annotating the property title and submitting documentation to the Division of Waste Management and Radiation Control (DWMRC). For information on how to comply with these requirements, contact the DWMRC Solid Waste Landfill Section Manager at (801) 536-0200. Approval for in-place closure has been granted by the Local Fire Department. (Must submit approval in writing with Closure Plan) Fire Dept. Phone# Contact person Date Approval for in-place closure has been granted by the Local Health Department. Health Dept. Phone# Contact person Date Substance to be used to fill tanks: 3 SITE ASSESSMENT A site assessment must be performed for all PST closures and change-in-service. Site assessments must be performed as outlined in 40 CFR 280.72 and U.A.C. R311-205. If contamination is suspected, additional samples must be collected at the location where contamination is most likely to be present. If groundwater is encountered, a soil sample must be collected, in the unsaturated zone, in addition to each groundwater sample. Soil and groundwater samples must be analyzed for the compounds shown in the following table, using appropriate lab methods. Substance or Product Type Contaminant Compounds to be Analyzed for Each Substance or Product Type ANALYTICAL METHODS1 Soil, Groundwater or Surface Water Gasoline Total Petroleum Hydrocarbons (purgeable TPH as gasoline range organics C6 - C10) Benzene, Toluene, Ethyl benzene, Xylenes, Naphthalene, (BTEXN) and MTBE EPA 8015 or EPA 8260 EPA 8021 or EPA 8260 Diesel Total Petroleum Hydrocarbons (extractable TPH as diesel range organics C10 – C28) Benzene, Toluene, Ethyl benzene, Xylenes, and Naphthalene (BTEXN) EPA 8015 EPA 8021 or EPA 8260 Used Oil Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) Benzene, Toluene, Ethyl benzene, Xylenes, Naphthalene (BTEXN) & MTBE; and Halogenated Volatile Organic Compounds (VOX) EPA 1664 or EPA 1664 (SGT*) EPA 8021 or EPA 8260 New Oil Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Other Type of analyses will be based upon the substance or product stored, and as approved by the DERR Division Director Method will be based upon the substance or product type Total Petroleum Hydrocarbons (purgeable TPH as gasoline EPA 8015 or EPA 8260 range organics C6 - C10) Total Petroleum Hydrocarbons (extractable TPH as diesel EPA 8015 range organics C10 – C28) Unknown Oil and Grease (O&G) or Total Recoverable Petroleum Hydrocarbons (TRPH) EPA 1664 or EPA 1664 (SGT*) Benzene, Toluene, Ethyl benzene, Xylenes, and Naphthalene EPA 8021 or EPA 8260 (BTEXN) and MTBE; and Halogenated Volatile Organic Compounds (VOX) 1 The following modifications to these certified methods are considered acceptable by the DERR Division Director: • Dual column confirmation may not be required for TPH and BTEXN/MTBE analysis. • A micro-extraction or scale-down technique may be used for aqueous samples, but only for the determination of extractable TPH as diesel range organics (C10 – C28). • Hexane may be used as an extraction solvent. • *Silica Gel Treatment (SGT) may be used in the determination of Total Recoverable Petroleum Hydrocarbons. NOTE: The sample preparation method and any modification(s) to a certified method must be reported by the laboratory. 4 CONTAMINATED MATERIALS MUST BE DISPOSED AT AN ACCEPTABLE FACILITY: All materials generated from PST closures must be managed and disposed in a manner that does not place those materials in direct contact with the environment. On-site stockpiling of contaminated soils may be required prior to any soil management activities. Any person providing remedial assistance for a fee, including aeration and over-excavation (of more than 50 yd3), must be a Certified UST Consultant. Contaminated soils generated as part of tank removal are to be disposed at the following facility: Address City State Zip Contact person Phone Complete the Facility Site Plat and Sample Information Table on pages 4 and 5 to provide site assessment information. CONTAMINATION INFORMATION If contamination at the facility is suspected or confirmed, the information must be reported to the DERR Division Director at (801) 536- 4100 within 24 hours. The Division of Water Quality must be notified at (801) 536-4300 if Free Product is encountered or if surface water has been impacted. If contamination is confirmed, any person assisting in the remediation process for a fee must be a Certified UST Consultant. SAMPLE INFORMATION TABLE Complete table for all samples to be taken for closure. Sample # Substance stored in tank Sample type1 Depth2 Compounds3 Analysis method(s)4 TH-1 GAS/DSL SOIL 12' MBTEXN TPH DRO GRO 8015,8260 TH-2 GAS/DSL SOIL 12 MBTEXN TPH DRO GRO 8015,8260 TH-3 GAS/DSL SOIL 12 MBTEXN TPH DRO GRO 8015,8260 TH-4 GAS/DSL SOIL 12 MBTEXN TPH DRO GRO 8015,8260 P1 GAS/DSL SOIL 3 MBTEXN TPH DRO GRO 8015,8260 P2 GAS/DSL Soil 3 MBTEXN TPH DRO GRO 8015,8260 USC-1 USC USC 12 MBTEXN TPH DRO GRO 8015,8260 USC-2 USC USC 12 MBTEXN TPH DRO GRO 8015,8260 1 Soil (SS), Groundwater (GW), or Unified Soil Classification (USC). 2 Approx. depth in feet below grade. The required minimum site assessment samples must be taken at 0-2 feet below the backfill/native soil interface. 3 Contaminant compounds to be analyzed for each sample (from table on p. 3). 4 Appropriate analysis methods for contaminant compound(s) in each sample (from table on p. 3). 5 Facility Site Plat (Closure Plan) The site plat must be drawn to an appropriate identified scale. It must show planned sampling locations, substances stored in tanks, and other relevant information. Tank and sample identification numbers must be consistent with the information given on pages 1 and 4 of the Closure Plan. North Scale: 1”= Feet Facility ID: 9000324 Drawn By: Aaron Spackman Date: 2/26/25 X = Sample locations (SS-#, WS-#, USC-#) Site Plat Must Indicate Approximate Locations of: ● = Monitoring Wells (MW-#) -Current & former tanks, piping & dispensers ○= Soil boring (SB-#), or Geoprobe Boring (GP-#) -Location of all samples to be taken ◘ = Water Wells (domestic, livestock, etc.) -Buildings, fences, & property boundaries Slope of Surface Topography: (N,NW,W,SW,S,SE,E,NE) -Utility conduits (sewers, gas, water, storm drains, electrical, etc.) Land Use At Site: Residential Commercial Industrial Surrounding Land: _ Residential Commercial Industrial 6 Approximate depth to groundwater in the vicinity of the tanks: 2 0feet. Regional groundwater flow direction: Unkown State Certified Laboratory to be used: Chemtech Ford Address 9632 S 500 W City Sandy State UT Zip 84070 Contact Person Office Phone 801-262-7299 Please explain any unusual or extenuating circumstances expected regarding the site assessment or closure: I certify under penalty of law that I am the owner/operator of the tank(s) referenced above and that I am familiar with the information on this form and that it is true, accurate and complete, and further, that the procedures described herein will be followed during tank closure. Signature of tank owner Donny Laws (Feb 27, 2025 06:54 MST) Full Name of tank owner Donny Laws Date 02/27/2025 Created: 2025-02-27 By: Status: Transaction ID: Aaron Spackman (aspackman@spackmanenterprises.com) Signed CBJCHBCAABAAs7w_IUyiG5A1SU05wFTpBCQYLnMSc9bT Uintah School District Closure Plan Final Audit Report 2025-02-27 "Uintah School District Closure Plan" History Document created by Aaron Spackman (aspackman@spackmanenterprises.com) 2025-02-27 - 3:55:43 AM GMT Document emailed to Donny Laws (donny.laws@uintah.net) for signature 2025-02-27 - 3:55:51 AM GMT Email viewed by Donny Laws (donny.laws@uintah.net) 2025-02-27 - 1:48:38 PM GMT Document e-signed by Donny Laws (donny.laws@uintah.net) Signature Date: 2025-02-27 - 1:54:55 PM GMT - Time Source: server Agreement completed. 2025-02-27 - 1:54:55 PM GMT