Loading...
HomeMy WebLinkAboutDERR-2025-001480 WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 PRODUCT PIPING INTEGRITY TESTING Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/26/25 This procedure is to test the integrity of product piping. Tests were performed with Petro-Tite line tester. Tank Number 1 (NE) 2 (SW) 3 (NW) 4 (SE) Product Stored RUL MUL PUL DSL Piping Run Only Out Only Out Piping Type FRP of FRP of Test Pressure (PSI) 50 Service 50 Service Test Duration (minutes) 30 30 Leak Rate (GPH) 0.004 0.003 Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature MU L PU L DS L RU L WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 MECHANICAL AND ELECTRONIC LINE LEAK DETECTOR PERFORMANCE TESTS Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/26/25 This data sheet can be used to test the mechanical line leak detector (MLLD) and electronic line leak detector (ELLD) with su bmersible turbine pump (STP) systems. See PEI/RP 1200 Sections 9.1 and 9.2 for test procedures. Line Number 1 2 3 4 Product Stored RUL MUL PUL DSL Leak Detector Manufacturer Red Jacket Red Jacket Leak Detector Model FX1V FX1V Type Of leak Detector ☒MLLD ☐ELLD ☐MLLD ☐ELLD ☒MLLD ☐ELLD ☐MLLD ☐ELLD MLLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure 28 Out 24 Out Check valve holding pressure 14 Of 16 Of Line resiliency (ml) (line bleedback volume as measured from check valve holding pressure to 0 psig) 65 Service 65 Service Step through time in seconds (time the MLLD hesitates at metering pressure before going to full operating pressure as measured from 0 sig with no leak induced on the line) 1 1 Metering pressure (STP pressure when simulated leak rate 3 gph at 10 psig) 10 10 Opening time in seconds (the time the MLLD opens to allow full pressure after simulated leak is stopped) 1 1 Does the STP pressure remain at or below the metering pressure for at least 60 seconds when the simulated leak is induced? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No Does the leak detector reset (trip) when the line pressure is bled off to zero psig? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No Does STP properly clycle on/off under normal fuel system operating conditions? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No A "No" answer to any of the above questions indicates that the MLLD fails the test. ELLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure How many test cycles are observed before alarm/shutdown occurs? Does the simulated leak cause on alarm? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" answer to the above question indicates that the ELLD fails the test. Does the simulated leak cause an STP shutdown? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Fast Break Owner: 379 South Corner Store Address: 379 South 300 West Address: 379 South 300 West City, State, Zip: Salt Lake City, Utah 84101 City, State, Zip: Salt Lake City, Utah 84101 Facility I.D.#: 4001552 Phone #: 385-399-6789 Testing Company: Westech Phone #: 801-266-2545 Date: 2/26/25 This procedure is to determine whether the automatic tank gauge (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank monitor stems the touch the bottom of the tank when in place. Tank Number 1 2 3 4 Product Stored RUL MUL PUL DSL ATG Brand and Model TLS 350 Out TLS 350 Out 1. Tank Volume, gallons 8,272 Of 5,264 Of 2. Tank Diameter, inches 96 Service 96 Service 3. After removing the ATG from the tank, it has been inspected and any damaged or missing parts replaced? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 4. Float moves freely on the stem without binding? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 5. Fuel float level agree with the value programmed into the console? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 6. Water float level agree with the value programmed into the console? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 7. Inch level from the bottom of the stem when 90% alarm is triggered? 80 7/8 80 7/8 8. Inch level at which the overfill alarm activates corresponds with the value programmed in the gauge? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No 9. Inch level from the bottom when the water float first triggers an alarm? 1.5 1.5 10. Inch level at which the water float alarm activates corresponds with the value programmed in the gauge? ☒Yes ☐No ☐Yes ☐No ☒Yes ☐No ☐Yes ☐No If any answers in Lines 3, 4, 5, or 6 are "No" the system has failed the test. Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature