Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2025-001373
IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION OVERFILL OPERABILITY PV VENT CAP SPILL BUCKET TEST STAGE 1 PD STAGE I SURVEY 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 2/21/2025 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 2/14/2025 Order Number: 2380351 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242 CENTERVILLE, UT 84014 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2380351 Date: 2/14/2025 Site Name/ID: 7-ELEVEN #33981, MKT 1606 / 33981 Address: 425 N 700 WEST State ID 3000242 City: CENTERVILLE State: UT Zip: 84014 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 TNK1 RUL Pressure 60 09:47 10:47 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 TNK2 RUL 2 Pressure 60 09:47 10:47 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 TNK3 PUL Pressure 60 09:47 10:47 0.00 Pass Yes Tank # 3 Line # 2 TLD-1 TNK3 PUL Pressure 60 09:47 10:47 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 TNK4 Low Sulfur Diesel Pressure 60 11:18 12:18 0.00 Pass Yes Tank # 4 Line # 2 TLD-1 TNK4 Low Sulfur Diesel Pressure 60 11:18 12:18 0.00 Pass Yes Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242 CENTERVILLE UT 84014 33981 Tanknology, Inc. 7-ELEVEN, INC. - PROJECT FORUM P.O. BOX 711 DALLAS TX 75221 972-828-7908 02/14/2025 RUL RUL 2 Low Sulfur DieselVeeder Root DPLLD Veeder Root DPLLD Veeder Root DPLLD Veeder Root DPLLD 36 2 33 2 2 37 38 2 UT151 David Mathie NW1-2380351 PUL TTNK1:1 TTNK2:1 TTNK3:1 TTNK4:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2380351 Date:2/14/2025 Site Name/ID:7-ELEVEN #33981, MKT 1606 Address:425 N 700 WEST State ID 3000242 City:CENTERVILLE State:UT Zip:84014 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 40 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 85 Pass Fail Not Tested 13/14 91 Pass Fail Not Tested 15/16 85 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested 17/18 85 Pass Fail Not Tested 17/18 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:2380351 Date:2/14/2025 Site Name/ID:7-ELEVEN #33981, MKT 1606 Address:425 N 700 WEST State ID 3000242 City:CENTERVILLE State:UT Zip:84014 Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 19/20 85 Pass Fail Not Tested 19/20 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN #33981, MKT 1606 7-ELEVEN, INC. - PROJECT FORUM 425 N 700 WEST State ID 3000242 CENTERVILLE UT 84014 3000242 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7908 800-964-1250 02/14/2025 1 2 3 4 RULL RUL2 PUL DSL VR450PLUS VR450PLUS VR450PLUS VR450PLUS 11682 9816 9816 9816 91.1 91.1 91.1 91.1 76.25 76.25 76.25 76.25 1 1 1 1 UT151 David Mathie 425 N 700 WEST State ID 3000242 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242, CENTERVILLE, UT 84014 33981 Tanknology, Inc. 7-ELEVEN, INC. - PROJECT FORUM P.O. BOX 711 DALLAS, TX 75221 972-828-7908 02/14/2025 SB FILL STP SB FILL STP SB FILL STP SB FILL RUL1 RUL1 RUL2 RUL2 PUL PUL DSL UT151 David Mathie 425 N 700 WEST State ID 3000242 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242, CENTERVILLE, UT 84014 33981 Tanknology, Inc. 7-ELEVEN, INC. - PROJECT FORUM P.O. BOX 711 DALLAS, TX 75221 972-828-7908 02/14/2025 STP UDC UDC UDC UDC UDC UDC DSL 1/2 3/4 5/6 7/8 9/10 11/12 UT151 David Mathie 425 N 700 WEST State ID 3000242 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242, CENTERVILLE, UT 84014 33981 Tanknology, Inc. 7-ELEVEN, INC. - PROJECT FORUM P.O. BOX 711 DALLAS, TX 75221 972-828-7908 02/14/2025 UDC UDC UDC UDC 13/14 15/16 17/18 19/20 UT151 David Mathie 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242 CENTERVILLE , UT 84014 3000242 Tanknology, Inc. 7-ELEVEN, INC. - PROJECT FORUM 972-828-7908 02/14/2025 P.O. BOX 711 DALLAS, TX 75221 1 RUL1 5 OPW 2 RUL2 5 OPW 3 PUL 5 OPW 4 DSL 5 OPW 15 WC 836 15 WC 841 5MIN 0 15 WC 844 15 WC 849 5MIN 0 15 WC 852 15 WC 857 5MIN 0 15 WC 900 15 WC 905 5MIN 0 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-ELEVEN #33981, MKT 1606 Name :TANKNOLOGY INC. Address :425 N 700 WEST State ID 3000242 CENTERVILLE, UT 84014 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-292-9370 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :20 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?N0 Total # of Tanks Tested :3 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK1 RUL 11682 9086 2596 11:18 2.00 1.96 1.93 1.90 1.87 1.85 1.65 Pass TNK2 RUL 2 9816 8260 1556 11:26 2.00 1.95 1.90 1.86 1.82 1.79 1.46 Pass TNK3 PUL 9816 8259 1557 11:34 2.00 19.50 19.00 18.60 18.20 18.00 1.46 Pass Total 31314 25605 5709 All Comments: Tester :David Mathie Test Date :2/14/2025 Signature :Work Order :2380351 WO: 2380351 PVVC tested ==>Rul1 Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.64 Pass Neg Leak Rate (CFH)0.21 18 0.0382 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.39 Pass PVVC tested ==>Rul2 Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.72 Pass Neg Leak Rate (CFH)0.21 16 0.0339 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.51 Pass PVVC tested ==>Pul Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 7 0.0148 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.59 Pass Neg Leak Rate (CFH)0.21 15 0.0318 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.63 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0381 Total -ve LR: 0.1039 Test Date 2/14/2025 Technician Name David Mathie WO #2380351 Facility Name / Loc #7-ELEVEN #33981, MKT 1606 33981 Street 425 N 700 WEST State ID 3000242 City, St, Zip CENTERVILLE, UT 84014 Pressure Vacuum Vent Cap Test Form TP-201.1E Stage I Vapor System Survey Survey to determine compliance with Requirements of Title 40 Part 63 National Emission Standards for Hazardous Air Pollutants for Source Categories Survey Date 2/14/2025 Work Order 2380351 Cust Name / Location Number 7-ELEVEN 33981 Street Address 425 N 700 WEST State ID 3000242 City, State, ZipCode CENTERVILLE UT 84014 Product Stage I Type Drop Tubes Type Drop Tubes Max inches from tank Bottom Fill Adapters Type Vapor Adapters Type NESHAP Work Required? Vent Caps Type Labeled Positive Cracking Pressure Labeled Negative Cracking Pressure TNK1 RUL Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No Rul1 Pressure Vacuum cap 3 8 TNK2 RUL 2 Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No Rul2 Pressure Vacuum cap 3 8 TNK3 PUL Dual Point Straight w/ Flapper 6.00 Swivel Regular (poppet) No Rul2 Pressure Vacuum cap 3 8 Describe Work Required Surveyed by Signature 7-ELEVEN #33981, MKT 1606 425 N 700 WEST State ID 3000242 CENTERVILLE , UT 84014 33981 Tanknology, Inc. 7-ELEVEN, INC. - PROJECT FORUM 972-828-7908 800-800-4633 02/14/2025 RUL1 1 11682 91.125 OPW RUL2 2 9816 91.125 OPW PUL 3 9816 91.125 OPW DSL 4 9816 91.125 OPW UT151 David Mathie P.O. BOX 711 DALLAS, TX 75221 Overfill Prevention Equipment Inspection OPW 61 and 71 Series Overfill Prevention Device Inspection Date:2/14/2025 Customer Name:7-ELEVEN, INC. - PROJECT FORUM Location #:7-ELEVEN #33981, MKT 1606 Location Address:425 N 700 WEST State ID 3000242 ,CENTERVILLE ,UT , 84014 OPW Model Number: PART 1) Proper height setting calculation Maximum Tank Volume per: A gallons Max shut off requirement for Flapper is 95% B 95% Multiply Maximum tank volume by 95% C gallons Use tank chart to determine height of calculated volume D inches Measure top of fill riser threads, or face seal adapter when used, to tank top E inches Tank diameter From Chart F inches Upper Tube in tank (G) F - D = G G inches Subtract 2 inches from upper tube in tank G - 2"= H H inches Calculated minimum upper tube length (I) H + E = I I inches Actual measured upper tube length (Without fill adapter) (J) J inches PART 2) Device certification criteria evaluation Criteria 1 Does the overfill prevention device meet the 95% requirement? Criteria 1a If the final shutoff volume is installed greater than 95%, is there at least 250 gallons of ullage above the overfill device activation point to ensure that none of the tank top fittings are exposed to product, meeting the criteria established in EPA 280.20iic and per OPW installation guidelines. Criteria 2 Is the Actual measured upper tube length 6.5 inches or more than the fill riser? (J must be 6.5" or more than E) Criteria 3 Does the overfill prevention device function as required? (Inspect the device for damage, contamination, freedom of movement, weakening due to wear and corrosion) PART 3) Device Certification PASS / FAIL Technician certifies that the device is operationally compliant. TNK1 11682.000 0.95 11097.900 81.500 42.750 91.125 9.625 7.625 50.375 50.750 Yes NA Yes Yes Pass TNK2 9816.000 0.95 9325.200 81.500 39.000 91.125 9.625 7.625 46.625 47.125 Yes NA Yes Yes Pass TNK3 9816.000 0.95 9325.200 81.500 37.875 91.125 9.625 7.625 45.500 46.000 Yes NA Yes Yes Pass TNK4 9816.000 0.95 9325.200 81.500 41.750 91.125 9.625 7.625 49.375 49.875 Yes NA Yes Yes Pass Comments: Signature of Technician: Date: 2/14/2025 David Mathie WO: NW1- 2380351 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2380351 Site ID / Name:33981 / 7-ELEVEN #33981, MKT 1606 Address:425 N 700 WEST State ID 3000242 City:CENTERVILLE State:UT Zip:84014 W.O.# NW1-2380351 Cust Ref#: REQ 1/31 $7262.5 +AAE- I10100 02/14/25 12:40 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 02/14/25 12:40 PM SOFTWARE REVISION LEVEL VERSION 33.58 SOFTWARE+ACM- 342005-010-P- CREATED - 24.07.02.14.24 +AAMAAQ- I20100 02/14/25 12:40 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 IN-TANK INVENTORY TANK PRODUCT VOLUME TC-VOLUME ULLAGE HEIGHT WATER TEMP 1 RUL1 N 1-4 11-16 9089 9166 2593 66.69 0.00 47.81 2 RUL2 S 5-10 17-20 8268 8330 1548 71.30 0.00 49.16 3 PUL 8263 8345 1553 71.70 0.00 45.64 4 DSL 8173 8210 1643 70.13 0.00 50.01 +AAMAAQ- I30100 02/14/25 12:40 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 Disp 1-2 Normal 2 Disp. 3-4 Normal 3 Disp. 5-6 Normal 4 Disp.. 7-8 Normal 5 Disp. 9-10 Normal 6 Disp.11-12 Normal 7 Disp. -13-14 Normal 8 Disp. 15-16 Normal 9 Disp. 17-18 Normal 10 Disp. 19-20 Normal 11 RUL1 Spill Bucket Normal 12 RUL1 STP sump Normal 13 RUL 2 Spill Bucket Normal 14 RUL2 STP sump Normal 15 PUL Spill Bucket Normal 16 PUL STP sump Normal 17 DSL Spill Bucket Normal 18 DSL STP sump Normal +AAMAAQ- I30200 02/14/25 12:40 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 Disp 1-2 02/14/25 9:28 AM FUEL ALARM 02/10/25 1:37 PM FUEL ALARM 02/10/25 1:36 PM SENSOR OUT ALARM 02/10/25 1:35 PM FUEL ALARM 02/10/25 1:34 PM SENSOR OUT ALARM 02/10/25 11:57 AM FUEL ALARM 02/10/25 11:46 AM FUEL ALARM 2 Disp. 3-4 02/14/25 9:26 AM FUEL ALARM 02/12/25 11:28 AM SENSOR OUT ALARM 02/10/25 11:58 AM FUEL ALARM 3 Disp. 5-6 02/14/25 9:25 AM FUEL ALARM 02/11/25 1:44 PM SENSOR OUT ALARM 4 Disp.. 7-8 02/14/25 9:24 AM FUEL ALARM 02/11/25 2:30 PM FUEL ALARM 02/11/25 2:29 PM SENSOR OUT ALARM 02/11/25 2:16 PM FUEL ALARM 02/11/25 1:52 PM SENSOR OUT ALARM 5 Disp. 9-10 02/14/25 9:22 AM FUEL ALARM 02/11/25 1:26 PM SENSOR OUT ALARM 6 Disp.11-12 02/14/25 9:27 AM FUEL ALARM 02/10/25 1:29 PM SENSOR OUT ALARM 02/10/25 11:43 AM FUEL ALARM 7 Disp. -13-14 02/14/25 9:25 AM FUEL ALARM 02/10/25 2:27 PM SENSOR OUT ALARM 02/10/25 2:25 PM FUEL ALARM 02/10/25 2:25 PM SENSOR OUT ALARM 8 Disp. 15-16 02/14/25 9:24 AM FUEL ALARM 02/11/25 12:51 PM SENSOR OUT ALARM 9 Disp. 17-18 02/14/25 9:23 AM FUEL ALARM 02/11/25 12:39 PM SENSOR OUT ALARM 01/31/25 2:17 PM SENSOR OUT ALARM 10 Disp. 19-20 02/14/25 9:29 AM FUEL ALARM 02/11/25 1:06 PM SENSOR OUT ALARM 01/31/25 2:06 PM SENSOR OUT ALARM 11 RUL1 Spill Bucket 02/14/25 10:07 AM FUEL ALARM 01/31/25 1:38 PM SENSOR OUT ALARM 12 RUL1 STP sump 02/14/25 9:51 AM FUEL ALARM 02/11/25 10:02 AM FUEL ALARM 02/11/25 9:08 AM FUEL ALARM 02/11/25 9:07 AM SENSOR OUT ALARM 01/31/25 2:32 PM FUEL ALARM 01/31/25 2:25 PM SENSOR OUT ALARM 01/31/25 2:15 PM SENSOR OUT ALARM 01/31/25 2:03 PM SENSOR OUT ALARM 01/31/25 1:56 PM SENSOR OUT ALARM 01/31/25 1:01 PM SENSOR OUT ALARM 01/31/25 12:53 PM SENSOR OUT ALARM 01/31/25 12:43 PM SENSOR OUT ALARM 01/31/25 12:29 PM SENSOR OUT ALARM 01/31/25 11:28 AM SENSOR OUT ALARM 01/31/25 11:15 AM SENSOR OUT ALARM 01/31/25 11:06 AM SENSOR OUT ALARM 01/31/25 10:06 AM SENSOR OUT ALARM 01/31/25 9:31 AM SENSOR OUT ALARM 01/31/25 9:09 AM SENSOR OUT ALARM 01/31/25 9:05 AM FUEL ALARM 01/31/25 8:50 AM SENSOR OUT ALARM 01/31/25 8:27 AM SENSOR OUT ALARM 01/31/25 8:11 AM SENSOR OUT ALARM 01/31/25 7:41 AM SENSOR OUT ALARM 01/31/25 7:24 AM SENSOR OUT ALARM 13 RUL 2 Spill Bucket 02/14/25 10:05 AM FUEL ALARM 01/31/25 10:15 AM SENSOR OUT ALARM 01/31/25 7:56 AM SENSOR OUT ALARM 01/31/25 6:16 AM SENSOR OUT ALARM 01/31/25 2:11 AM SENSOR OUT ALARM 01/31/25 12:48 AM SENSOR OUT ALARM 01/30/25 11:02 PM SENSOR OUT ALARM 01/30/25 10:32 PM SENSOR OUT ALARM 01/30/25 8:38 PM SENSOR OUT ALARM 01/30/25 6:50 PM SENSOR OUT ALARM 01/30/25 6:06 PM SENSOR OUT ALARM 01/30/25 5:26 PM SENSOR OUT ALARM 14 RUL2 STP sump 02/14/25 9:58 AM FUEL ALARM 02/14/25 9:49 AM FUEL ALARM 02/11/25 9:11 AM SENSOR OUT ALARM 02/11/25 8:56 AM FUEL ALARM 02/11/25 8:56 AM SENSOR OUT ALARM 02/11/25 8:56 AM FUEL ALARM 01/31/25 12:41 PM SENSOR OUT ALARM 01/31/25 12:12 PM SENSOR OUT ALARM 01/31/25 11:29 AM SENSOR OUT ALARM 01/31/25 10:58 AM SENSOR OUT ALARM 01/31/25 10:17 AM SENSOR OUT ALARM 01/31/25 10:08 AM SENSOR OUT ALARM 01/31/25 9:51 AM SENSOR OUT ALARM 01/31/25 4:24 AM FUEL ALARM 01/31/25 4:23 AM SENSOR OUT ALARM 01/30/25 11:07 PM FUEL ALARM 01/30/25 11:05 PM SENSOR OUT ALARM 01/30/25 3:54 PM FUEL ALARM 15 PUL Spill Bucket 02/14/25 10:06 AM FUEL ALARM 01/31/25 1:57 PM SENSOR OUT ALARM 01/31/25 1:09 PM SENSOR OUT ALARM 01/31/25 10:57 AM SENSOR OUT ALARM 16 PUL STP sump 02/14/25 9:50 AM FUEL ALARM 01/31/25 2:18 PM SENSOR OUT ALARM 01/31/25 2:03 PM SENSOR OUT ALARM 01/31/25 1:51 PM SENSOR OUT ALARM 01/31/25 1:37 PM SENSOR OUT ALARM 01/31/25 1:15 PM SENSOR OUT ALARM 01/31/25 1:07 PM SENSOR OUT ALARM 01/31/25 12:36 PM SENSOR OUT ALARM 01/31/25 12:12 PM SENSOR OUT ALARM 01/31/25 11:15 AM SENSOR OUT ALARM 01/31/25 10:41 AM SENSOR OUT ALARM 01/31/25 10:01 AM SENSOR OUT ALARM 01/31/25 9:22 AM SENSOR OUT ALARM 01/31/25 8:43 AM SENSOR OUT ALARM 01/31/25 8:03 AM SENSOR OUT ALARM 01/31/25 6:46 AM SENSOR OUT ALARM 01/31/25 6:26 AM SENSOR OUT ALARM 01/31/25 5:58 AM SENSOR OUT ALARM 01/31/25 5:39 AM SENSOR OUT ALARM 01/31/25 5:15 AM SENSOR OUT ALARM 01/31/25 4:16 AM SENSOR OUT ALARM 01/31/25 3:20 AM SENSOR OUT ALARM 01/31/25 3:01 AM SENSOR OUT ALARM 01/31/25 2:39 AM SENSOR OUT ALARM 01/31/25 2:02 AM SENSOR OUT ALARM 17 DSL Spill Bucket 02/14/25 10:03 AM FUEL ALARM 01/31/25 1:25 PM SENSOR OUT ALARM 01/31/25 7:53 AM SENSOR OUT ALARM 01/31/25 6:10 AM SENSOR OUT ALARM 01/31/25 5:40 AM SENSOR OUT ALARM 01/31/25 4:21 AM SENSOR OUT ALARM 01/31/25 3:56 AM SENSOR OUT ALARM 01/31/25 1:17 AM SENSOR OUT ALARM 01/30/25 6:45 PM SENSOR OUT ALARM 01/30/25 5:38 PM SENSOR OUT ALARM 18 DSL STP sump 02/14/25 12:33 PM FUEL ALARM 02/14/25 10:09 AM SENSOR OUT ALARM 02/14/25 10:08 AM FUEL ALARM 02/14/25 9:48 AM FUEL ALARM 01/31/25 1:52 PM SENSOR OUT ALARM 01/31/25 12:14 PM SENSOR OUT ALARM 01/31/25 11:48 AM SENSOR OUT ALARM 01/31/25 11:17 AM SENSOR OUT ALARM 01/31/25 10:56 AM SENSOR OUT ALARM 01/31/25 10:02 AM SENSOR OUT ALARM 01/31/25 9:55 AM FUEL ALARM 01/31/25 9:45 AM SENSOR OUT ALARM 01/31/25 9:37 AM SENSOR OUT ALARM 01/31/25 9:12 AM SENSOR OUT ALARM 01/31/25 8:44 AM SENSOR OUT ALARM 01/31/25 8:38 AM SENSOR OUT ALARM 01/31/25 7:42 AM SENSOR OUT ALARM 01/31/25 6:35 AM SENSOR OUT ALARM 01/31/25 5:26 AM SENSOR OUT ALARM 01/31/25 4:58 AM SENSOR OUT ALARM 01/31/25 4:26 AM SENSOR OUT ALARM 01/31/25 3:23 AM SENSOR OUT ALARM 01/31/25 2:44 AM SENSOR OUT ALARM 01/31/25 2:12 AM SENSOR OUT ALARM 01/31/25 12:19 AM SENSOR OUT ALARM +AAMAAQ- I20600 02/14/25 12:41 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 TANK ALARM HISTORY TANK 1 RUL1 N 1-4 11-16 SETUP DATA WARNING 02/11/25 2:01 PM HIGH WATER ALARM 02/14/25 10:44 AM OVERFILL ALARM 02/14/25 10:47 AM PROBE OUT 01/29/25 4:07 PM HIGH WATER WARNING 02/14/25 10:44 AM DELIVERY NEEDED 02/14/25 10:41 AM TANK 2 RUL2 S 5-10 17-20 SETUP DATA WARNING 02/11/25 2:01 PM HIGH WATER ALARM 02/14/25 10:31 AM OVERFILL ALARM 02/14/25 10:35 AM SUDDEN LOSS ALARM 02/14/25 10:29 AM PROBE OUT 02/12/25 8:14 AM 01/29/25 4:07 PM HIGH WATER WARNING 02/14/25 10:30 AM DELIVERY NEEDED 02/14/25 10:27 AM TANK 3 PUL SETUP DATA WARNING 02/11/25 2:01 PM HIGH WATER ALARM 02/14/25 10:43 AM OVERFILL ALARM 02/14/25 10:47 AM PROBE OUT 01/29/25 4:07 PM HIGH WATER WARNING 02/14/25 10:43 AM DELIVERY NEEDED 02/14/25 10:39 AM TANK 4 DSL SETUP DATA WARNING 02/11/25 2:01 PM HIGH WATER ALARM 02/14/25 10:30 AM OVERFILL ALARM 02/14/25 10:34 AM PROBE OUT 01/31/25 2:37 PM 01/29/25 4:07 PM HIGH WATER WARNING 02/14/25 10:30 AM DELIVERY NEEDED 02/14/25 10:37 AM 02/14/25 10:26 AM +AAMAAQ- I38200 02/14/25 12:41 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 PRESSURE LINE LEAK ALARM HISTORY REPORT Ln 1: RUL1 N 1-4 11-16 GROSS LINE FAIL 02/14/25 11:59 AM PLLD SHUTDOWN ALARM 02/14/25 11:59 AM GROSS LINE FAIL 02/12/25 3:29 PM PLLD SHUTDOWN ALARM 02/12/25 3:29 PM GROSS LINE FAIL 02/12/25 3:03 PM PLLD SHUTDOWN ALARM 02/12/25 3:03 PM GRS TST NEEDED ALM 02/11/25 5:06 PM SETUP DATA WARNING 01/30/25 4:40 PM Ln 2: RUL2 S 5-10 17-20 GROSS LINE FAIL 02/14/25 11:53 AM PLLD SHUTDOWN ALARM 02/14/25 11:53 AM PLLD OPEN ALARM 02/11/25 3:07 PM PLLD OPEN ALARM 02/11/25 9:11 AM PLLD OPEN ALARM 01/31/25 12:35 PM Ln 3: PUL GROSS LINE FAIL 02/14/25 11:56 AM PLLD SHUTDOWN ALARM 02/14/25 11:56 AM GROSS LINE FAIL 02/14/25 8:34 AM PLLD SHUTDOWN ALARM 02/14/25 8:34 AM PLLD OPEN ALARM 02/10/25 11:34 AM PLLD OPEN ALARM 02/10/25 11:25 AM PLLD OPEN ALARM 01/31/25 12:28 PM PLLD OPEN ALARM 01/31/25 11:49 AM SETUP DATA WARNING 01/31/25 9:37 AM Ln 4: DSL 1-2 9-10 GROSS LINE FAIL 02/14/25 12:34 PM PLLD SHUTDOWN ALARM 02/14/25 12:34 PM SETUP DATA WARNING 02/11/25 10:25 AM PLLD OPEN ALARM 02/11/25 10:24 AM SETUP DATA WARNING 02/11/25 10:19 AM PLLD OPEN ALARM 02/10/25 1:55 PM SETUP DATA WARNING 01/31/25 10:23 AM +AAMAAQ- I37400 02/14/25 12:41 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 PRESSURE LINE LEAK TEST HISTORY Ln 1: RUL1 N 1-4 11-16 LAST 3.0 PASS: 02/14/25 12:12 PM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 02/13/25 12:19 PM Ln 2: RUL2 S 5-10 17-20 LAST 3.0 PASS: 02/14/25 12:10 PM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 02/12/25 4:01 PM Ln 3: PUL LAST 3.0 PASS: 02/14/25 12:12 PM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 02/12/25 5:54 PM Ln 4: DSL 1-2 9-10 LAST 3.0 PASS: 02/14/25 12:38 PM FIRST 0.1 PASS EACH MONTH: NOT AVAILABLE FIRST 0.2 PASS EACH MONTH: 02/12/25 12:52 PM +AAM- +AAMAAQ- I20700 02/14/25 12:41 PM 297762 7-11 33981 425 No. 700 West Centerville Ut 84014 Z07296088305001 TANK LEAK TEST HISTORY - PASSED TEST RESULTS T 1: RUL1 N 1-4 11-16 AVERAGE +ACU- REPORT TYPE DATE/TIME METHOD HOURS VOLUME VOLUME ---------------- -------------- ------ ----- ------- ------ LAST GROSS 02/14/25 9:55 SLD 9162 78.4 LAST PERIODIC 02/14/25 11:59 CSLD 97 9442 80.8 FULLEST PERIODIC 02/01/25 22:10 CSLD 26 9452 80.9 T 2: RUL2 S 5-10 17-20 AVERAGE +ACU- REPORT TYPE DATE/TIME METHOD HOURS VOLUME VOLUME ---------------- -------------- ------ ----- ------- ------ LAST GROSS 02/14/25 9:42 SLD 8321 84.8 LAST PERIODIC 02/14/25 11:47 CSLD 35 8487 86.5 FULLEST PERIODIC 02/01/25 5:49 CSLD 15 8516 86.8 T 3: PUL AVERAGE +ACU- REPORT TYPE DATE/TIME METHOD HOURS VOLUME VOLUME ---------------- -------------- ------ ----- ------- ------ LAST GROSS 02/14/25 9:36 SLD 8341 85.0 LAST PERIODIC 02/14/25 11:55 CSLD 117 8479 86.4 FULLEST PERIODIC 02/01/25 8:54 CSLD 12 8502 86.6 T 4: DSL AVERAGE +ACU- REPORT TYPE DATE/TIME METHOD HOURS VOLUME VOLUME ---------------- -------------- ------ ----- ------- ------ LAST GROSS 02/14/25 9:27 SLD 8213 83.7 LAST PERIODIC 02/14/25 12:25 CSLD 62 8324 84.8 FULLEST PERIODIC 02/03/25 9:04 CSLD 44 8362 85.2 +AAMAAQ- I6SU00 02/14/25 12:41 PM -------------------------------------------------------- +ACoAKgAq- SETUP FOR ALL TANKS +ACoAKgAq- -------------------------------------------------------- ULLAGE DISPLAY MODE: FULL ULLAGE USER ULLAGE FULL ULLAGE LABEL: 100+ACU- ULLAGE USER ULLAGE: 90+ACU- PRINT TC VOLUMES: ENABLED TC REFERENCE TEMPERATURE: 60 DEG F PERIODIC TEST NEEDED WARNINGS: ENABLED DAYS BEFORE PERIODIC WARNING: 25 DAYS BEFORE PERIODIC ALARM: 30 ANNUAL TEST NEEDED WARNINGS: DISABLED DAYS BEFORE ANNUAL WARNING: 355 DAYS BEFORE ANNUAL ALARM: 365 TC DENSITY: DISABLED STICK HEIGHT: DISABLED LEAK TEST REPORT FORMAT: STANDARD LEAK TEST REGION: EPA -------------------------------------------------------- +ACoAKgAq- TANK SETUP +ACoAKgAq- -------------------------------------------------------- --- GENERAL SETUP - TANK 1 --- CONFIGURED: ENABLED LABEL: RUL1 N 1-4 11-16 PRODUCT CODE: 1 PROBE NUMBER: Pb 1: RUL1 PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11682 GALLONS DIAMETER: 91.1 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000690 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 1 --- MAX VOLUME: 11682 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 482 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 25 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 1 --- TANK TEST METHOD: CSLD GROSS TEST AUTO CONFIRM: DISABLED PROBABILITY OF DETECTION: 95+ACU- CLIMATE FACTOR: MODERATE CSLD EVAPORATION COMPENSATION: DISABLED STAGE II VAPOR RECOVERY: DISABLED --- PROFILE - TANK 1 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 11682 003 45.6 5756 002 68.3 9327 004 22.8 2186 --- TANK 1 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2025-02-11 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 11682 003 45.6 5756 002 68.3 9327 004 22.8 2186 --- TANK 1 --- T1 SIPHON MANIFOLDED TO TANKS: NONE T1 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 1 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 1 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 2 --- CONFIGURED: ENABLED LABEL: RUL2 S 5-10 17-20 PRODUCT CODE: 1 PROBE NUMBER: Pb 2: RUL2 PROBE OFFSET: 0.00 INCHES FULL VOLUME: 9816 GALLONS DIAMETER: 91.1 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000690 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 2 --- MAX VOLUME: 9816 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 399 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 25 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 2 --- TANK TEST METHOD: CSLD GROSS TEST AUTO CONFIRM: DISABLED PROBABILITY OF DETECTION: 95+ACU- CLIMATE FACTOR: MODERATE CSLD EVAPORATION COMPENSATION: DISABLED STAGE II VAPOR RECOVERY: DISABLED --- PROFILE - TANK 2 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 9816 003 45.6 4940 002 68.3 7926 004 22.8 1917 --- TANK 2 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2025-02-11 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 9816 003 45.6 4940 002 68.3 7926 004 22.8 1917 --- TANK 2 --- T2 SIPHON MANIFOLDED TO TANKS: NONE T2 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 2 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 2 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 3 --- CONFIGURED: ENABLED LABEL: PUL PRODUCT CODE: 3 PROBE NUMBER: Pb 3: PUL PROBE OFFSET: 0.00 INCHES FULL VOLUME: 9816 GALLONS DIAMETER: 91.1 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000690 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 3 --- MAX VOLUME: 9816 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 399 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 25 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 3 --- TANK TEST METHOD: CSLD GROSS TEST AUTO CONFIRM: DISABLED PROBABILITY OF DETECTION: 95+ACU- CLIMATE FACTOR: MODERATE CSLD EVAPORATION COMPENSATION: DISABLED STAGE II VAPOR RECOVERY: DISABLED --- PROFILE - TANK 3 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 9816 003 45.6 4864 002 68.3 7874 004 22.8 1848 --- TANK 3 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2025-02-11 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 9816 003 45.6 4864 002 68.3 7874 004 22.8 1848 --- TANK 3 --- T3 SIPHON MANIFOLDED TO TANKS: NONE T3 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 3 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 3 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 4 --- CONFIGURED: ENABLED LABEL: DSL PRODUCT CODE: 4 PROBE NUMBER: Pb 4: DSL PROBE OFFSET: 0.00 INCHES FULL VOLUME: 9816 GALLONS DIAMETER: 91.1 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS ENABLED PERIODIC TEST FAIL: ALARMS ENABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 4 --- MAX VOLUME: 9816 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 15+ACU- LOW PRODUCT: 399 GALLONS HIGH WATER WARNING: 0.80 INCHES HIGH WATER ALARM: 1.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 25 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 4 --- TANK TEST METHOD: CSLD GROSS TEST AUTO CONFIRM: DISABLED PROBABILITY OF DETECTION: 95+ACU- CLIMATE FACTOR: MODERATE CSLD EVAPORATION COMPENSATION: DISABLED STAGE II VAPOR RECOVERY: DISABLED --- PROFILE - TANK 4 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 9816 003 45.6 4976 002 68.3 7965 004 22.8 1933 --- TANK 4 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2025-02-11 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 91.1 9816 003 45.6 4976 002 68.3 7965 004 22.8 1933 --- TANK 4 --- T4 SIPHON MANIFOLDED TO TANKS: NONE T4 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 4 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 60 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 95+ACU- --- HRM - TANK 4 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS +AAMAAQ- I61100 02/14/25 12:41 PM LEAK TEST +AHwAPA----- START TEST TIME -----+AD4AfA- TEST TEST TEST START TANK METHOD TYPE HOURS METHOD YEAR MONTH DAY OCCUR HH:MM ---- ------ -------- ----- ------------ ---- ----- --- ----- ----- 1 CSLD PERIODIC 2 CSLD PERIODIC 3 CSLD PERIODIC 4 CSLD PERIODIC +AAMAAQ- I70300 02/14/25 12:41 PM LIQUID MODEL SENSOR LABEL MODEL 1 Disp 1-2 Tri-State(Single Float) 2 Disp. 3-4 Tri-State(Single Float) 3 Disp. 5-6 Tri-State(Single Float) 4 Disp.. 7-8 Tri-State(Single Float) 5 Disp. 9-10 Tri-State(Single Float) 6 Disp.11-12 Tri-State(Single Float) 7 Disp. -13-14 Tri-State(Single Float) 8 Disp. 15-16 Tri-State(Single Float) 9 Disp. 17-18 Tri-State(Single Float) 10 Disp. 19-20 Tri-State(Single Float) 11 RUL1 Spill Bucket Normally Closed 12 RUL1 STP sump Tri-State(Single Float) 13 RUL 2 Spill Bucket Normally Closed 14 RUL2 STP sump Tri-State(Single Float) 15 PUL Spill Bucket Normally Closed 16 PUL STP sump Tri-State(Single Float) 17 DSL Spill Bucket Normally Closed 18 DSL STP sump Tri-State(Single Float) 19 Tri-State(Single Float) 20 Tri-State(Single Float) 21 Tri-State(Single Float) 22 Tri-State(Single Float) 23 Tri-State(Single Float) 24 Tri-State(Single Float) 25 Tri-State(Single Float) 26 Tri-State(Single Float) 27 Tri-State(Single Float) 28 Tri-State(Single Float) 29 Tri-State(Single Float) 30 Tri-State(Single Float) 31 Tri-State(Single Float) 32 Tri-State(Single Float) 33 Tri-State(Single Float) 34 Tri-State(Single Float) 35 Tri-State(Single Float) 36 Tri-State(Single Float) 37 Tri-State(Single Float) 38 Tri-State(Single Float) 39 Tri-State(Single Float) 40 Tri-State(Single Float) 41 Tri-State(Single Float) 42 Tri-State(Single Float) 43 Tri-State(Single Float) 44 Tri-State(Single Float) 45 Tri-State(Single Float) 46 Tri-State(Single Float) 47 Tri-State(Single Float) 48 Tri-State(Single Float) 49 Tri-State(Single Float) 50 Tri-State(Single Float) 51 Tri-State(Single Float) 52 Tri-State(Single Float) 53 Tri-State(Single Float) 54 Tri-State(Single Float) 55 Tri-State(Single Float) 56 Tri-State(Single Float) 57 Tri-State(Single Float) 58 Tri-State(Single Float) 59 Tri-State(Single Float) 60 Tri-State(Single Float) 61 Tri-State(Single Float) 62 Tri-State(Single Float) 63 Tri-State(Single Float) 64 Tri-State(Single Float) 65 Tri-State(Single Float) 66 Tri-State(Single Float) 67 Tri-State(Single Float) 68 Tri-State(Single Float) 69 Tri-State(Single Float) 70 Tri-State(Single Float) 71 Tri-State(Single Float) 72 Tri-State(Single Float) 73 Tri-State(Single Float) 74 Tri-State(Single Float) 75 Tri-State(Single Float) 76 Tri-State(Single Float) 77 Tri-State(Single Float) 78 Tri-State(Single Float) 79 Tri-State(Single Float) 80 Tri-State(Single Float) 81 Tri-State(Single Float) 82 Tri-State(Single Float) 83 Tri-State(Single Float) 84 Tri-State(Single Float) 85 Tri-State(Single Float) 86 Tri-State(Single Float) 87 Tri-State(Single Float) 88 Tri-State(Single Float) 89 Tri-State(Single Float) 90 Tri-State(Single Float) 91 Tri-State(Single Float) 92 Tri-State(Single Float) 93 Tri-State(Single Float) 94 Tri-State(Single Float) 95 Tri-State(Single Float) 96 Tri-State(Single Float) 97 Tri-State(Single Float) 98 Tri-State(Single Float) 99 Tri-State(Single Float) +AAMAAQ- I78000 02/14/25 12:41 PM PRESSURE LINE LEAK SETUP Q 1: RUL1 N 1-4 11-16 PIPE TYPE: OPW FLEXWORKS 15 LINE LENGTH: 170 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 1 - RUL1 N 1-4 11-16 PRESSURE OFFSET: 0.0 psi Q 2: RUL2 S 5-10 17-20 PIPE TYPE: OPW FLEXWORKS 15 LINE LENGTH: 170 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 2 - RUL2 S 5-10 17-20 PRESSURE OFFSET: 0.0 psi Q 3: PUL PIPE TYPE: OPW FLEXWORKS 15 LINE LENGTH: 300 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 3 - PUL PRESSURE OFFSET: 0.0 psi Q 4: DSL 1-2 9-10 PIPE TYPE: OPW FLEXWORKS 15 LINE LENGTH: 220 FEET 0.2 GAL/HR TEST: REPETITIVE 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 5.0 psi TANK: 4 - DSL PRESSURE OFFSET: 0.0 psi Q 5: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 6: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 7: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 8: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 9: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 10: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 11: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 12: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 13: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 14: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 15: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 16: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi PEI/RP1200-12 pei.org42 APPENDIX C-2 PIPING SECONDARY CONTAINMENT INTEGRITY TESTING )DFLOLW\1DPH 2ZQHU $GGUHVV $GGUHVV &LW\6WDWH=LS&RGH &LW\6WDWH=LS&RGH )DFLOLW\,' 3KRQH 7HVWLQJ&RPSDQ\ 3KRQH 'DWH 7KLVSURFHGXUHLVWRWHVWWKHLQWHJULW\RIWKHLQWHUVWLWLDOVSDFHRIGRXEOHZDOOHGSLSLQJ6HH3(,536HFWLRQIRUWKHWHVW SURFHGXUH 7DQN1XPEHU 3LSLQJ5XQ 3LSLQJ0DWHULDO 3URGXFW6WRUHG 7HVW6WDUW7LPH ,QLWLDO7HVW3UHVVXUHSVLJ 7HVWSURFHGXUHVSHFLILHV SVLJ 7HVW(QG7LPH )LQDO7HVW3UHVVXUHSVLJ 3UHVVXUH&KDQJH1R UHGXFWLRQLQSUHVVXUH DOORZHGIRUSDVV Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB TANKNOLOGY 801-831-7097 UT151 DAVE MATHIE 5 5 5 5 5 5 5 5 5 5 5 5 0 0 0 0 0 0