HomeMy WebLinkAboutDAQ-2025-001072
1
DAQC-171-25
Site ID 16015 (B5)
MEMORANDUM
TO: FILE – HOLLY ENERGY PARTNERS – Light Oil Dock
THROUGH: Harold Burge, Major Source Compliance Section Manager
FROM: Rob Leishman, Environmental Scientist
DATE: February 12, 2025
SUBJECT: Holly Energy Partners, Light Oil Dock (Holly LOD), Major, MACT, SIP, Title V,
Davis County, FRS # UT00000049001100013
INSPECTION TYPE: State Electronic Data Report (SEDR) Review
REVIEW DATE: February 12, 2025
SOURCE LOCATION: West Bountiful/Davis County
SOURCE CONTACT: Daria Underwood – 214-954-3935
APPLICABLE
REGULATIONS: Title V operating permit – 1100458001 – dated February 8, 2021
SOURCE INSPECTION
EVALUATION: With the exception of sources that only monitor for opacity,
quarterly report memoranda will only address the findings of the
quarterly report. Approval Order and Title V permit conditions
addressing continuous emission monitoring requirements will be
addressed in Holly LOD’s relative accuracy performance
specification test review memorandum.
SOURCE REVIEW EVALUATION:
Fourth Quarter 2024
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During
Point Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
LOD 2198 VOC 99% 12/05/24 11/19/24 LOD VOC 0.00 10000 ppm -
6 hour RA
1 8 2
2
Excess Emission Report - Hourly Summary
Point
Source Channel
Startup
&
Shutdown
Control
Equipment
Problems
Process
Problems
Other
Known
Causes
Unknown
Causes
Emission
Limit
LOD VOC 0 0 0 0 0 10000 ppm - 6 hour
RA
CMS Performance Summary - Hourly Summary
Point
Source Channel Monitor
Malfunction
Non-monitor
Malfunction
QA
Calibrations
Other
Known
Causes
Unknown
Causes
LOD VOC 0 0 13 0 0
Pollutant Concentration
Exceeded Span of CEM
Monitor Outage During
Point Source Operation
Alternate
Sampling CEM Modifications
0 Hours 0 Hours 0 Hours 0 Events
SOURCE INSPECTION
SUMMARY EVALUATION: Holly LOD maintains its CEMS as required in R307-170 and 40
CFR 60.13.
CURRENT
RECOMMENDATIONS: All deviations appear to be a result of breakdown or process
related problems that do not warrant issuing a violation. Holly
LOD was in compliance during this reporting period. No further
enforcement action is necessary. Holly LOD’s NSPS monitoring
system meets the performance standards of 40 CFR 60,
Appendix B, Performance Specifications.
HIGH PRIORITY
VIOLATOR (HPV): No
RECOMMENDATION
FOR NEXT INSPECTION: Check DAS for daily zero and span drift.
Check the QC program to ensure that monitor drift is being
tracked and that the source can identify excessive drift.
ATTACHMENTS: Excel spreadsheet review
,.tttf $nctor i rrDsrREAM
January 29,2025
Utah Division of Air Quality
195 North 1950 West
Salt Lake City Utah 84116
Re:ll; _.-_ __-- __ ____---_ .,1
Dear SirlMadam:
Enclosed please find the Q4-2024 Woods Cross Terminal Continuous Emission Monitoring System (CEMS) Report.
Per Utah Administrative Code R307-170-9, the electronic ASCII report file will be sent to Rob Leishman, UDAQ,
with this report, via e-mail. The following information is applicable to report contents:
The continuous monitoring system calibration and drift checks were routinely performed, and a quarterly
cylinder gas audit (CGA) was completed on 1215/2024 and found within the required performance
specifications. The data used to show compliance with the standard were obtained in accordance with
approved methods and procedures.
The minimum data requirements have been met, with minimal missin8 data. Overall CEMS downtime was
0.57% including required QC (daily span/zero checks) and CGA during the 4'h quarter. Total CEMS QC and CGA
downtime was 12.5 hours.
VRU required approximately 10 hours 33 minutes of downtime during this quarter for routine maintenance.
All activities were under planned preventative maintenance and operational needs in alignment with the
permit. During VRU downtime, LOD effluent was diverted to the VCU or loading operations were discontinued.
Compliance with the general requirements under Utah Administrative Code R307-170-5 has been achieved
during the reporting period.
I certify under penalties of law that, based upon inquiry of personnel involved, and to the best of my knowledge,
the statements and information contained in this report are truthful and accurate, and are a complete record of all
monitoring-related events that occurred during the reporting period.
lf you have any questions or need additional information, please contact me at John.Paris@hfsinclair.com.
Attachment:trlLl HEP CEMS EER Worksheet, 4th Quarter 2024
Ll ir\i ' [)r-r,,r,F.i i,,:5i,1 6i. --
i! Vi l-.'rl'Nll:1 ir ii I,1.i (i L IALITY-t
i
4'h Quarter 2024 cEMs Report
Woods Cross Terminal, Approval Order DAQE-AN0101200238{7
Holly Energy Partners
1.
2.
3.
4.
'esident - Operations
Corporate Offlce:
0peraUons Offlce:
2828 N. Hanvood, Sulte 1il0o
1602 West Maln Street
Dallas, TX 75201-1507 2!l-8713555
Artesla, NM 88210 57$7484000
Attachment: HEP CEMS EER Worksheet, 4th Quarter 2024
(Note: A copy of the attached EER worksheet, in CSV format, was submitted to Mr. Rob Leishman on
January 30,2025, via email from Estee Lafrenz, ERM, on behalf of HEP)
1OO t&rkTCunnlnghanHoltyEnerP.O.Eo(1260Artesla,Newm01l-00013 (21,+)871-3555JohnParis
1r0 LoD 4 20?4 2198
200 LoD
220 LOo
230 LOD
250 LOD
28{' LOO
260 LOD
s00 LoD
310 LOD
460 LoD
700
700
700
700
700
720
720
720
720
720
7g
730
730
730
730
730
730
7g
7g
730
730
730
730
730
o
l7l79no24
tu5no21
7a5no21
ttnu20x
5000 20,@0 u8/2016 \,8U
12 ppm 1102.5 976,7
Zgrzxl2 Certltled Malter ptrcent
7llol2a32 C.nlfied Master percent
2.21+6 pess
0.51 0.511 .0.2ott Pass
1.007 1.096 0.(r(,t pass
0-m 0
10000 ppm 6hourRA
voc
voc
, ?627795
2 RAIX,:rI
low
mld
12.5
voc
701 Startup/Shutdom
702 Controt Equipment Problems
703 Procsss Probtqns
704 OthGrXmwnCau*s
706 Unknown C€usc!
721 I'bnitor Equipment l<unction
722 NonmonltorEq!lpment Matlunctlon
723 QACatibrationt
724 Othu Xmwn Caucos
726 Unkn0vn Caura
703 A Pomrlailure.
703 B Contotwtvaraiture.
703 c PumplolluE
7u A olhcrhnMcsu3es. B€tlnaryproductproc€srchsngetorwlnlorErades
705 A Unknwn crwe.
721 A Dallycrtlbrallonchectexceedrnce. CaEsof dritlunknm' Rtrallb.atcdlmtrument.
72lg DstrrecordGrraltuE.
72lC Powertailurc.Notoadlngdurlnsout0ge.
721O Monildtailure
722 A VRU Equipmntlailule. VCU ussd rorconttot.
7 A {QA,/QC)-VCUusedtorcontrol.
724 A Meterproving. VCIJ Bedlorcontrcl.
7u g VRU maintananco. vCU usodlorcontrol.
7 c a.lonltormalntsnancq
t-rinH orpnnrMrrui-5n-
E NVIROI.!MENTAL QUALIT\
t---- -_-_-_-r
II rrP, -3 )r)t l
I
Irl
DIVISION OF AIR OUALITY
FEB
Holly EP LOD EER 4Q2024
Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No
1 Type Code 100
(Company Information)Type Code Company Manager Company Name AIRS # Phone Number
Environmental
Contact
1 100
Mark T
Cunningham 01100013 (214)871-3555 John Paris0
1 100 0 0 0 0
1 Type Code 110
(Point Source Identification)Type Code Point Source
Quarter
1 - 4 Year
Point Source
Operating Hrs. in
Quarter
1 110 4 2024 2198
1 110 0 0 0
1 Type Code 200
(Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date Monitor
Location
1 200 VOC IR 8400D 5086 5000 20000 8/8/2016 VRU
1 200 0 0 0 0 0 0 1/0/1900 0
1
Type Code310
(Excess Emissions)
SUMMARY REPORT
Type Code Channel
Total Hours of Excess
Emissions
Excess Emissions -
% of Total
Operating Hours
RC 701 Hours -
start
up/Shutdown
RC 702 Hours-
Control Equipment
Problems
RC 703 Hours -
Process Problems
RC 704, 706, 707
Hours -Other Known
Causes
RC 705 Hours -
Unknown
Causes
Emission
Limitation
Emission
Limitation
Units
Emission
Limitation
Averaging
Period
1 TRUE 310 VOC 0 0.00% 0 0 0 0 0 10000 ppm 6 hour RA
1 310 0 0 0 0 0 0 0 0 0
1 Type Code 300 (CMS
Performance Summary) Type Code Channel
Point Source Operating
Hours
Downtime - % of
Total Operating
Hours
Total CMS
Downtime
RC 721 Hours -
Monitor
Malfunction
RC 722 Hours -
Non-monitor
Malfunction
RC 723 Hours -
QA Calibrations
RC 724 Hours -
Other Known
Causes
RC 725
Hours -
Unknown
Causes
1 TRUE 300 VOC 2198 0.57% 12.5 0 0 12.5 0 0
1 300 0 0 0 0 0 0
1
Type Code 250
(Performance Specification
RATA Results)
Type Code Channel
Date of Most Current
RATA
Date of Preceding
RATA
Months Between
RATA's
Units of
Measurement CEM Value Reference Method
Value
Relative
accuracy Pass/ Fail
1 364 Days 250 VOC 11/19/24 11/21/23 12 ppm 1102.5 976.7 2.21% pass
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
1 Type Code 260
(CGA Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 260 VOC 12/05/24 1 P627795 07/09/32 Certified Master Gaspercent 5100 5110 -0.20% pass low
1 Valid Cal. Gas 260 VOC 12/05/24 2 R817032 07/10/32 Certified Master Gaspercent 10970 10960 0.06% pass mid
1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 Type Code 270
(Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code Channel Start Date Start Time End Date End Time Hours
1 0 0 0 1/0/00 0:00 1/0/00 0:00
1
1 None Reported
1 0 TC 220 Hours 0.00 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00
1 12.50 TC 300 Hours 12.50 FALSE
Yes None Reported None Reported None Reported None Reported None Reported
Point Source
Point Source
Point Source
Point Source
Point Source
Point Source
Yes
LOD
0
LOD
LOD
LOD
0
Type Code 550
(Changes in Operation in
Control Equipment When
CEM Data Not Available)
Type Code 500
(Boiler Operating Days
w/o 18 Hours of Data)
Holly Energy Partners Operating, L.P.
0
Type Code 450
(Data Excluded)
LOD
0
LOD
0
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code 220
(Monitor Outage
During Point Source Operation)
Type Code 230
(Manual Sample - Alternate
Sampling During Monitor
Outage)
Type Code 240
(CEM Modifications)
Type Code 530
(Excess Emissions During
Emergency Conditions)
0
LOD
0
0
0
Holly EP LOD EER 4Q2024
Relative Accuracy Overview
Point Source Channel
Date of Most
Current
RATA
Date of
Preceding
RATA
Months Between
RATA's
Units
Measured CEM Value Reference Method
Value
Relative
Accuracy Pass/ Fail
LOD VOC 11/19/24 11/21/23 12 ppm 1102.5 976.70 2.21% pass
*
NSPS CGA Fourth 2024
Audit Gas Ranges Audit Gas Ranges
AP1 Low AP2 Low AP1 High AP2 High
LOD VOC 12/5/24 20000 5110 4000 to 6000
LOD VOC 12/5/24 20000 10960 10000 to 12000
Point Source Channel Audit Date Low Span Audit Gas Used High Span Audit Gas Used
Holly EP LOD EER 4Q2024
Monitoring Information TC 210, 230, & 240
Type Code 210
(Pollutant Concentration Exceeded Span of CEM) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 230
(Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) VOC Grand Total
(blank)0 0
LOD 0 0
Grand Total 0 0 0
*
Type Code 240
(CEM Modifications) - 100 (All)
*
Count of Channel Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
Grand Total
Holly EP LOD EER 4Q2024
Type Code 220
(Monitor Outage During Point Source Operation) - 600 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
0 0
LOD
VOC
0 0 0
Grand Total 0 0
Holly EP LOD EER 4Q2024
VOC/THC *
VOC/THC Type Code 460 (VOC/THC) - 6000 (All)
VOC/THC *
VOC/THC Count of Magnitude of Emissions Column Labels
VOC/THC Row Labels (blank)0 Grand Total
VOC/THC LOD
VOC/THC #N/A 1 1
VOC/THC Grand Total 1 1
Holly EP LOD EER 4Q2024
Type Code 500
Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of
Data) After February 28, 2005 (90% Operating Hours For each 30 BOD)
- 500
(All)
*
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 510
(F-factor, Equations & Conversion Factors) - 500 (All)
Count of F-factor Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 520
(Minimum Data Not
Obtained <22/30 BODs) - 500
(All)
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 530
(Excess Emissions During Emergency Conditions) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 540
(Fuel Pre-treatment Credit SO2) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
TypeCode 550
(Changes in Operation in Control Equipment When CEM Data Not
Available) - 500
(All)
Column Labels
Row Labels Grand Total
Grand Total