Loading...
HomeMy WebLinkAboutDAQ-2025-001068 1 DAQC-164-25 Site ID 10007 (B5) MEMORANDUM TO: FILE – HOLCIM (US) INCORPORATED – Devil’s Slide THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Rob Leishman, Environmental Scientist DATE: February 11, 2025 SUBJECT: Holcim USA Incorporated (Holcim), Major, Title V, MACT, NSPS, Weber County, FRS # UT00000049002900001 INSPECTION TYPE: State Electronic Data Report (SEDR) Review REVIEW DATE: February 11, 2025 SOURCE LOCATION: Devil’s Slide/Weber County SOURCE CONTACT: Mark Miller – Director of Land and Environment – 972-221-4646 Javier Sosa – Plant Manager – 801-829-6821 APPLICABLE REGULATIONS: Title V Operating Permit PERMIT NUMBER: 2900001004 DATE OF PERMIT: November 18, 2021 Date of Last Revision: March 25, 2022 SOURCE INSPECTION EVALUATION: With the exception of sources that only monitor for opacity, quarterly report memoranda will only address the findings of the quarterly report. Approval Order and Title V permit conditions addressing continuous emission monitoring requirements will be addressed in Holcim’s relative accuracy performance specification test review memorandum. SOURCE REVIEW EVALUATION: Fourth Quarter 2024 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation Kiln 2043 THC 99% RATA Completed 11/20/24 Kiln NOx 0.00 - Kiln 2043 HCl 100% 11/05/24 05/02/24 Kiln SO2 0.00 - 1 8 2 2 Fourth Quarter 2024 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation Kiln 2043 O2 100% 11/08/24 07/18/24 Kiln SO2 0.00 - Kiln 2043 NOx 99% 11/05/24 07/18/24 Kiln HCl 0.00 - Kiln 2043 SO2 99% 11/05/24 07/18/24 Kiln THC 0.00 - Kiln 2043 CO2 100% 11/05/24 07/18/24 Kiln Hg 0.00 - Kiln 2043 Hg 99% 10/09/24 07/18/24 Excess Emission Report - Hourly Summary Point Source Channel Startup & Shutdown Control Equipment Problems Process Problems Other Known Causes Unknown Causes Emission Limit Kiln NOx 0 0 0 0 0 Kiln SO2 0 0 0 0 0 Kiln SO2 0 0 0 0 0 Kiln HCl 0 0 0 0 0 Kiln THC 0 0 0 0 0 Kiln Hg 0 0 0 0 0 CMS Performance Summary - Hourly Summary Point Source Channel Monitor Malfunction Non-monitor Malfunction QA Calibrations Other Known Causes Unknown Causes Kiln THC 3 0 8 13 0 Kiln HCl 3 0 4 3 0 Kiln O2 0 0 6 3 0 Kiln NOx 3 0 23 3 0 Kiln SO2 3 0 23 3 0 Kiln CO2 3 0 4 3 0 Kiln Hg 11 0 7 0 0 Pollutant Concentration Exceeded Span of CEM Monitor Outage During Point Source Operation Alternate Sampling CEM Modifications 0 Hours 129 Hours 0 Hours 0 Events 3 SOURCE INSPECTION SUMMARY EVALUATION: Holcim is maintaining its COMS as required in R307-170 and 40 CFR 603. Cylinder gas audits were conducted as required. CURRENT RECOMMENDATIONS: Deviations appear to be a result of breakdown or process related problems that do not warrant issuing a violation. Periods of excess emissions that were recorded by the CMS in service on each point source during this reporting period are summarized in the SEDR and described in Pivot Table 400 “Excess Emissions Review.” Holcim was in compliance during this reporting period. No further enforcement actions should be taken. Holcim’s NSPS monitoring system meets the performance standards of 40 CFR 60, Appendix B, Performance Specifications. HIGH PRIORITY VIOLATOR (HPV): Yes, due to prior violations which haven’t been settled as of this date. RECOMMENDATION FOR NEXT INSPECTION: Check DAS for daily zero and span drift. Check the QC program to ensure that monitor drift is being tracked and that the source can identify excessive drift. ATTACHMENTS: Excel spreadsheet review Holcim EER 4Q2024 Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No 1 Type Code 100 (Company Information)Type Code Company Manager Company Name AIRS # Phone Number Environmental Contact1 100 Javier Sosa Ortiz 02900001 801-829-2122 Clinton Badger 1 100 0 0 0 0 1 Type Code 110(Point Source Identification)Type Code Point Source Quarter1 - 4 Year Point Source Operating Hrs. in Quarter 1 110 4 2024 2043 1 110 0 0 0 1 Type Code 200(Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date Monitor Location1 200 CO2 ABB ACF5000 3.368022.6 0 30 Nov. 16 Stack 1 200 HCl ABB ACF5000 3.368022.6 0 20 Nov. 16 Stack 1 200 Hg Tekran 3310Xi 3122 0 20 Nov. 16 Stack 1 200 NOx ABB ACF5000 3.368022.6 0 1000 Nov. 16 Stack 1 200 O2 ABB ACF5000 3.368022.6 0 25 Nov. 16 Stack 1 200 SO2 ABB ACF5000 3.368022.6 0 325 Nov. 16 Stack 1 200 THC ABB AO2020 248861242 0 60 Oct. 24 Stack 1 200 0 0 0 0 0 0 1/0/1900 0 1 Type Code310 (Excess Emissions) SUMMARY REPORT Type Code Channel Total Hours of Excess Emissions Excess Emissions - % of Total Operating Hours RC 701 Hours - start up/Shutdown RC 702 Hours- Control Equipment Problems RC 703 Hours -Process Problems RC 704, 706, 707 Hours -Other Known Causes RC 705 Hours - Unknown Causes Emission Limitation Emission Limitation Units Emission Limitation Averaging Period1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0 0 0 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0 0 0 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0 0 0 1 TRUE 310 HCl 0 0.00% 0 0 0 0 0 0 0 0 1 TRUE 310 THC 0 0.00% 0 0 0 0 0 0 0 0 1 TRUE 310 Hg 0 0.00% 0 0 0 0 0 0 0 0 1 310 0 0 0 0 0 0 0 0 0 1 Type Code 300 (CMSPerformance Summary) Type Code Channel Point Source Operating Hours Downtime - % of Total Operating Hours Total CMS Downtime RC 721 Hours - Monitor Malfunction RC 722 Hours - Non-monitor Malfunction RC 723 Hours - QA Calibrations RC 724 Hours - Other Known Causes RC 725 Hours - Unknown Causes1 TRUE 300 THC 2043 1.17% 24 3 0 8 13 0 1 TRUE 300 HCl 2043 0.49% 10 3 0 4 3 0 1 TRUE 300 O2 2043 0.44% 9 0 0 6 3 0 1 TRUE 300 NOx 2043 1.42% 29 3 0 23 3 0 1 TRUE 300 SO2 2043 1.42% 29 3 0 23 3 0 1 TRUE 300 CO2 2043 0.49% 10 3 0 4 3 0 1 TRUE 300 Hg 2043 0.88% 18 11 0 7 0 0 1 300 0 0 0 0 0 0 1 Type Code 250 (Performance SpecificationRATA Results) Type Code Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units of Measurement CEM Value Reference Method Value Relative accuracy Pass/ Fail 1 324 Days 250 Hg 07/18/24 08/29/23 10 wscm 1.068 1.431 0.49% 0 1 Late 250 HCl 05/02/24 11/01/22 18 ppm 4.11 3.97 4.93% 0 1 125 Days 250 THC 11/20/24 07/18/24 4 ppmw 22.778 25.11 12.52% 0 1 364 Days 250 NOx 07/18/24 07/20/23 11 ppmw 282.367 293.751 5.63% 0 1 364 Days 250 O2 07/18/24 07/20/23 11 0 9.256 10.256 10.40% 0 1 364 Days 250 SO2 07/18/24 07/20/23 11 lb/hr 3.556 4.159 0.27% 0 1 364 Days 250 CO2 07/18/24 07/20/23 11 0 15.578 14.922 5.66% 0 1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0 1 Type Code 260 (CGA Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 Valid Cal. Gas 260 CO2 11/05/24 1 CC142824 11/30/29 EPA P1 % 7.83 7.48 4.63% P Low 1 Valid Cal. Gas 260 CO2 11/05/24 2 CC365043 05/04/28 EPA P1 % 17.06 16.52 3.28% P High 1 Valid Cal. Gas 260 HCl 11/05/24 1 CC515631 04/17/26 EPA P1 ppm 4.95 4.98 0.64% P Low 1 Valid Cal. Gas 260 HCl 11/05/24 2 CC513769 01/15/26 EPA P1 ppm 10.88 11.29 3.64% P High 1 Valid Cal. Gas 260 Hg 10/09/24 1 3310 Xi N/A NIST µg 5.26 4.94 6.55% P Low 1 Valid Cal. Gas 260 Hg 10/09/24 2 3310 Xi N/A NIST µg 11.22 10.7 4.88% P High 1 Valid Cal. Gas 260 NOx 11/05/24 1 CC142824 11/30/29 EPA P1 ppm 254.99 252.4 1.03% P Low 1 Valid Cal. Gas 260 NOx 11/05/24 2 CC174579 05/04/28 EPA P1 ppm 563.33 561.3 0.36% P High 1 Valid Cal. Gas 260 O2 11/08/24 1 ALM025754 02/04/29 EPA P1 % 5.2 5.07 2.62% P Low 1 Valid Cal. Gas 260 O2 11/08/24 2 EB025754 09/04/27 EPA P1 % 10.93 10.97 0.38% P High 1 Valid Cal. Gas 260 SO2 11/05/24 1 CC365043 05/04/28 EPA P1 ppm 77 81 4.94% P Low 1 Valid Cal. Gas 260 SO2 11/05/24 2 CC142824 11/30/29 EPA P1 ppm 174.68 179.8 2.85% P High 1 Expired Cal. Gas 260 THC RATA Completed 1 N/A N/A ppm N/A N/A N/A P Low 1 Expired Cal. Gas 260 THC RATA Completed 2 N/A N/A ppm N/A N/A N/A P High 1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 270(Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code Channel Start Date Start Time End Date End Time Hours 1 0 0 0 1/0/00 0:00 1/0/00 0:00 1 1 None Reported 1 0 TC 220 Hours 129.00 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00 1 129.00 TC 300 Hours 0.00 TRUE None Reported None Reported None Reported None Reported None Reported None Reported Point Source Point Source Point Source Point Source Point Source Point Source Yes Kiln Kiln Kiln Kiln Kiln 0 Kiln 0 Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln 0 Kiln Kiln Kiln Type Code 550 (Changes in Operation in Control Equipment When CEM Data Not Available) Type Code 500(Boiler Operating Daysw/o 18 Hours of Data) Holcim US Inc. 0 Type Code 450 (Data Excluded) Kiln Kiln Kiln Kiln Kiln Kiln Kiln 0 Kiln 0 Kiln Kiln Type Code 210(Pollutant ConcentrationExceeded Span of CEM) Type Code 220(Monitor OutageDuring Point Source Operation) Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) Type Code 240 (CEM Modifications) Type Code 530(Excess Emissions During Emergency Conditions) Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln Kiln 0 0 0 Holcim EER 4Q2024 Relative Accuracy Overview Point Source Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units Measured CEM Value Reference Method Value Relative Accuracy Pass/ Fail Kiln Hg 07/18/24 08/29/23 10 wscm 1.068 1.43 0.49% Kiln HCl 05/02/24 11/01/22 18 ppm 4.11 3.97 4.93% Kiln THC 11/20/24 07/18/24 4 ppmw 22.778 25.11 12.52% Kiln NOx 07/18/24 07/20/23 11 ppmw 282.367 293.75 5.63% Kiln O2 07/18/24 07/20/23 11 9.256 10.26 10.40% Kiln SO2 07/18/24 07/20/23 11 lb/hr 3.556 4.16 0.27% Kiln CO2 07/18/24 07/20/23 11 15.578 14.92 5.66% * NSPS CGA Fourth 2024 Audit Gas Ranges Audit Gas Ranges AP1 Low AP2 Low AP1 High AP2 High Kiln CO2 11/5/24 30 7.48 5 to 8 Kiln CO2 11/5/24 30 16.52 10 to 14 Kiln HCl 11/5/24 20 4.98 10 to 12 Kiln HCl 11/5/24 20 11.29 16 to 24 Kiln Hg 10/9/24 20 4.94 4 to 6 Kiln Hg 10/9/24 20 10.7 10 to 12 Kiln NOx 11/5/24 1000 252.4 200 to 300 Kiln NOx 11/5/24 1000 561.3 500 to 600 Kiln O2 11/8/24 25 5.07 4 to 6 Kiln O2 11/8/24 25 10.97 8 to 12 Kiln SO2 11/5/24 325 81 65 to 97.5 Kiln SO2 11/5/24 325 179.8 162.5 to 195 Kiln THC RATA Completed 60 N/A 12 to 18 Kiln THC RATA Completed 60 N/A 12 to 18 Point Source Channel Audit Date Low Span Audit Gas Used High Span Audit Gas Used Holcim EER 4Q2024 Monitoring Information TC 210, 230, & 240 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 240 (CEM Modifications) - 100 (All) * Count of Channel Column Labels Row Labels (blank) Grand Total (blank) (blank) Grand Total Holcim EER 4Q2024 Type Code 220 (Monitor Outage During Point Source Operation) - 600 (All) * Sum of Hours Column Labels Row Labels 723 724 721 Grand Total Kiln NOx Daily Calibration 23.0 23.0 THC monitor replacement causing adjacent monitor downtime 3.0 3.0 Monitor Anomaly / Malfunction 3.0 3.0 SO2 Daily Calibration 23.0 23.0 THC monitor replacement causing adjacent monitor downtime 3.0 3.0 Monitor Anomaly / Malfunction 3.0 3.0 O2 Daily Calibration 2.0 2.0 THC monitor replacement causing adjacent monitor downtime 3.0 3.0 Monitor Anomaly / Malfunction 3.0 3.0 Preventative Maintenance 1.0 1.0 CO2 Daily Calibration 4.0 4.0 THC monitor replacement causing adjacent monitor downtime 3.0 3.0 Monitor Anomaly / Malfunction 3.0 3.0 HCl Daily Calibration 4.0 4.0 THC monitor replacement causing adjacent monitor downtime 3.0 3.0 Monitor Anomaly / Malfunction 3.0 3.0 THC Daily Calibration 6.0 6.0 THC monitor replacement causing adjacent monitor downtime 3.0 3.0 Monitor Anomaly / Malfunction 8.0 8.0 Preventative Maintenance 2.0 2.0 Monitor Replacement 5.0 5.0 Hg Daily Calibration 7.0 7.0 Monitor Anomaly / Malfunction 11.0 11.0 Grand Total 72.0 23.0 34.0 129.0 Holcim EER 4Q2024 SO2 * SO2 Type Code 410 (SO2) - 6000 (All) SO2 * SO2 Count of Magnitude of Emissions Column Labels SO2 Row Labels Grand Total SO2 Grand Total NOx * NOx Type Code 420 (NOx) - 6000 (All) NOx * NOx Count of Magnitude of Emissions Column Labels NOx Row Labels Grand Total NOx Grand Total CO * CO Type Code 440 (CO) - 6000 (All) CO * CO Count of Magnitude of Emissions Column Labels CO Row Labels Grand Total CO Grand Total VOC/THC * VOC/THC Type Code 460 (VOC/THC) - 6000 (All) VOC/THC * VOC/THC Count of Magnitude of Emissions Column Labels VOC/THC Row Labels Grand Total VOC/THC Grand Total O2 * O2 Type Code 470 (TRS as O2) - 6000 (All) O2 * O2 Count of Magnitude of Emissions Column Labels O2 Row Labels Grand Total O2 Grand Total Hg * Hg Type Code 480 (Hg Mercury) - 6000 (All) Hg * Hg Count of Magnitude of Emissions Column Labels Hg Row Labels Grand Total Hg Grand Total HCl * HCl Type Code 401 HCl - 6000 (All) HCl * HCl Count of Magnitude of Emissions Column Labels HCl Row Labels Grand Total HCl Grand Total Holcim EER 4Q2024 Type Code 500 Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of Data) After February 28, 2005 (90% Operating Hours For each 30 BOD) - 500 (All) * Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 510 (F-factor, Equations & Conversion Factors) - 500 (All) Count of F-factor Column Labels Row Labels Grand Total Grand Total * Type Code 520 (Minimum Data Not Obtained <22/30 BODs) - 500 (All) Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 530 (Excess Emissions During Emergency Conditions) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * Type Code 540 (Fuel Pre-treatment Credit SO2) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * TypeCode 550 (Changes in Operation in Control Equipment When CEM Data Not Available) - 500 (All) Column Labels Row Labels Grand Total Grand Total