Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2025-001327
IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION OVERFILL OPERABILITY PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 2/17/2025 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 1/10/2025 Order Number: 2375406 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN 45954/9420 2187 W. 4700 SOUTH State ID 4001832 SALT LAKE CITY, UT 84129 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 01/10/2025 4001832 Speedway #9420 2187 W. 4700 S. S.L.C., UT 84118 214-415-0146 Jacob Powell Max LaRou UT-412 50 P.S.I. REG 0 68 15 68 0 0 0 30 68 0 0 0 PASS PRM 0 58 15 58 0 0 0 30 58 0 0 0 PASS DSL 0 51 15 51 0 0 0 30 51 0 0 0 PASS 01/10/2025 Max LaRou UT-412 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV0//'DQGHOHFWURQLFOLQHOHDNGHWHFWRUV(//'ZLWKVXEPHUVLEOH WXUELQHSXPS673V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\POOLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGVWLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGVWKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHWWULSZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Speedway #9420 4001832 01/10/2024 1 REG V.M.I. LD2000 4 32 16 85 1 18 4 4 4 4 4 2 PRM V.M.I. LD2000 4 30 18 90 1 19 5 4 4 4 4 3 DSL V.R. FX1DV 4 35 15 90 1 12 5 4 4 4 4 Max LaRou UT-412 PEI/RP1200-12 pei.org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´1RµRU/LQHLV´<HVµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Speedway #9420 01/10/2025 1 Reg VR TLS 450 9728 92 4 4 4 4 4 75 5/8 8758 90 4 4 4 4 2 Prm VR TLS 450 9728 92 4 4 4 4 4 75 5/8 8758 90 4 4 4 4 3 Dsl VR TLS 450 9728 92 4 4 4 4 4 75 5/8 8758 90 4 4 4 4 Zak Goldberg UT-435 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Speedway #9420 1 Reg VR TLS 450 9728 92 4 4 4 4 75 5/8 4 1 4 4 2 Prm VR TLS 450 9728 92 4 4 4 4 75 5/8 4 1 4 4 3 Dsl VR TLS 450 9728 92 4 4 4 4 75 5/8 4 1 4 4 Zak Goldberg UT-435 01/10/2025 PE I / R P 1 2 0 0 - 1 2 pe i . o r g 50 A P P E N D I X C - 1 0 SHEAR VALVE OPERATION INSPECTION )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH 7KLVGDWDVKHHWLVIRULQVSHFWLQJVKHDUYDOYHVORFDWHGLQVLGHGLVSHQVHUV6HH3(,536HFWLRQIRUWKHLQVSHFWLRQSURFHGXUH 3URGXFW*UDGH 'LVSHQVHU,' 6KHDU9DOYH7\SH3URGXFW9DSRU ,VWKHVKHDUYDOYHULJLGO\ DQFKRUHGWRWKHGLVSHQVHUER[ IUDPHRUGLVSHQVHULVODQG" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R ,VWKHVKHDUVHFWLRQSRVL WLRQHGEHWZHHQóLQFKDERYH RUEHORZWKHWRSVXUIDFHRIWKH GLVSHQVHULVODQG" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R ,VWKHOHYHUDUPIUHHWRPRYH"<HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ 'RHVWKHOHYHUDUPVQDSVKXW WKHSRSSHWYDOYH" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ &DQDQ\SURGXFWEHGLVSHQVHG ZKHQWKHSURGXFWVKHDUYDOYHLV FORVHG" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ $´1RµWR/LQHVRUD´<HVµIRU/LQHLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV )DLO 3DVV )DLO 3DVV )DLO 3DVV )DLO 3DVV )DLO 3DVV )DLO 3DVV )DLO 3DVV )DLO 3DVV )DLO Comments: 7HVWHU·V1aPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies, Inc. 801-886-9224 Date: Speedway #9420 4001832 R/P 1/2, 7/8 P 4 4 4 4 4 4 R/P/D 3/4, 5/6 P 4 4 4 4 4 4 Max LaRou UT-412 01/10/2025 FORM 1 SUMMARY OF SOURCE TEST DATA SOURCE INFORMATION FACILITY PARAMETERS GDF Name and addresss GDF Representative and Title _________________________________ PHASE II SYSTEM TYPE (Check One) Balance ____ Hirt ____ Red Jacket ____ Hasstech ____ Healy ____Other GDF Phone No. (___)________________ Permit Conditions Source: GDF Vapor Recovery System GDF # A/C # Manifolded? Y or N Operating Parameters Number of Nozzles Served by Tank #1 ______ Number of Nozzles Served by Tank #3 ______ Number of Nozzles Served by Tank #2 ______ Number of Nozzles Served by Tank #4 ______ Applicable Regulations: VN Recommended Source Test Results and Comments Tank #: 1.Product Grade 2.Actual Tank Capacity, gallons 3.Gasoline Volume 4.Ullage, gallons (#2-#3) 5.Initial Pressure, inches H 2 O 6.Pressure After 1 Minute, inches H 2 O 7.Pressure After 2 Minutes, inches H 2 O 8.Pressure After 3 Minutes, inches H 2 O 9.Pressure After 4 Minutes, inches H 2 O 10.Final Pressure After 5 Minutes, inches H 2 O 11.Allowable Final Pressure Test Conducted by: Test Company: Date of Test: California Air Resources Board July 26, 2012 TP-201.3, Page 14 40CFR63CCCCCC Precision Testing Technologies Speedway #9420 V.R.S. Dual Point 4 1 REG 9,728 7,307 2 PRM 9,728 8,256 3,903 2.00 1.95 1.91 1.87 1.85 1.84 1.65 Max LaRou UT-412 01/10/2025 Speedway #9420 Pressure/Vacuum (P/V) Vent Valve Data Sheet Facility Name: Test Date: Address: Test Company: Precision Testing Technologies City: Tester Name: Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): 2.5" to 6" wc <=0.05 cfh @ 2" wc 2.5" to 6" wc <=0.05 cfh @2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc Speedway #9420 01/10/2025 Max LaRou UT-412 REG OPW 723V 4 0.03 cfh @ 2"wc 3.4"wc 0.17 cfh @ 4"wc -7.8"wc PRM OPW 723V 4 0.03 cfh @ 2"wc 4.1"wc 0.16 cfh @ 4"wc -8.3"wc Speedway #9420 Max LaRou UT-412 01/10/2025 California Air Resources Board October 8, 2003 TP-201.1B, Page 5 Form 1 Static Torque of Rotatable Phase I Adaptors Measurement Units: (Check Box): pound-inches pound-feet Vapor Adaptor 1 Vapor Adaptor 2 Vapor Adaptor 3 Vapor Adaptor 4 Brand:Brand:Brand:Brand: Model:Model:Model:Model: Grade:Grade:Grade:Grade: Torque 1:Torque 1:Torque 1:Torque 1: Torque 2:Torque 2:Torque 2:Torque 2: Torque 3:Torque 3:Torque 3:Torque 3: Average:Average:Average:Average: 360 Rotation:360 Rotation: 360 Rotation:360 Rotation: Product Adaptor 1 Product Adaptor 2 Product Adaptor 3 Product Adaptor 4 Brand:Brand:Brand:Brand: Model:Model:Model:Model: Grade:Grade:Grade:Grade: Torque 1:Torque 1:Torque 1:Torque 1: Torque 2:Torque 2:Torque 2:Torque 2: Torque 3:Torque 3:Torque 3:Torque 3: Average:Average:Average:Average: 360 Rotation: 360 Rotation: 360 Rotation:360 Rotation: Comments: ___________________________________________________________________ Test Company:Conducted By: Test Date:Facility Name: Facility Address:City: Precision Testing Technologies Max LaRou UT-412 01/10/2025 Speedway #9420 4 OPW 61VSA REG 75 70 65 70 Yes OPW 61SALP REG 50 50 50 50 Yes OPW 61VSA PRM 100 85 85 90 Yes OPW 61SALP PRM 65 65 60 63 Yes Yes Yes Yes Yes