HomeMy WebLinkAboutDERR-2025-001313EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 01/03/2025 1200563 Ogden Cardlock 1500 W. 2550 S. Ogden, UT 84401 541-295-9890 Chad Lujan Max LaRou UT-412 60 P.S.I. REG Auto 0 81 15 81 0 0 0 30 81 0 0 0 PASS PRM Auto 0 75 15 75 0 0 0 30 75 0 0 0 PASS CLR DSL Auto, Sats 5-7 0 69 15 69 0 0 0 30 69 0 0 0 PASS DYE DSL Auto 0 53 15 53 0 0 0 30 53 0 0 0 PASS CLR Auto 0 44 15 44 0 0 0 30 44 0 0 0 PASS 01/03/2025 Max LaRou UT-412 EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 01/03/2025 1200563 Ogden Cardlock 1500 W 2550 S Ogden, UT 84401 541-295-9890 Chad Lujan Zak Goldberg EST-410373 60 Psi #1 Clear Bulk 0 87 15 87 0 0 0 30 87 0 0 0 Pass Premium Bulk 0 76 15 76 0 0 0 30 76 0 0 0 Pass Regular Bulk 0 64 15 64 0 0 0 30 64 0 0 0 Pass #2 Red Small Bulk 0 58 15 58 0 0 0 30 58 0 0 0 Pass #2 Red Big Bulk 0 47 15 47 0 0 0 30 47 0 0 0 Pass #1 Red Bulk 0 42 15 42 0 0 0 30 42 0 0 0 Pass 01/03/2025 Zak Goldberg EST-410373 EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 1200563 Ogden Cardlock Zak Goldberg ESTA-410373 60 Psi #2 Clear Bulk 0 34 15 34 0 0 0 30 34 0 0 0 Pass Zak Goldberg ESTA-410373 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 1 REG Auto V.R. FX1V 4 36 22 100 1 11 4 4 4 4 4 2 PRM Auto V.R. FX1V 4 32 19 110 1 12 5 4 4 4 4 3 CLR DSL Auto V.R. FX1DV 4 40 21 145 1 11 7 4 4 4 4 4 DYE DSL Auto V.M.I. LD2000 4 38 19 200 1 17 5 4 4 4 4 5 CLR Auto V.R. FX1V 4 36 22 175 1 12 4 4 4 4 4 Max LaRou UT-412 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 6 Red Bulk VMI LD3000 4 38 20 290 1 18 6 4 4 4 4 7 Prem Bulk VMI LD3000 4 38 21 350 1 21 4 4 4 4 4 8 #2 Red S VMI LD3000 4 37 20 400 1 4 9 #2 RedDsl VMI LD3000 4 36 21 280 1 4 10 #1 Red VMI LD3000 4 38 22 290 1 19 5 4 4 4 4 11 #2 Clr Dsl VMI LD3000 4 37 19 180 2 18 5 4 4 4 4 Zak Goldberg UT-435 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 12 #1 Clr Dsl VMI LD3000 4 40 19 340 2 18 5 4 4 4 4 Zak Goldberg UT-435 PEI/RP1200-12 pei.org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´1RµRU/LQHLV´<HVµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 1 HS DYE DSL V.R. TLS 350 15,000 120 4 4 4 4 4 98 13,500 90 4 4 4 4 2 LS DYE DSL V.R. TLS 350 6,000 120 4 4 4 4 4 99 1/2 5,400 90 4 4 4 4 3 1LS DYE DSL V.R. TLS 350 6,000 120 4 4 4 4 4 99 1/2 54,400 90 4 4 4 4 4 LS CLR DSL V.R. TLS 350 15,000 120 4 4 4 4 4 98 13,500 90 4 4 4 4 Max LaRou UT-412 PEI/RP1200-12 pei.org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´1RµRU/LQHLV´<HVµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 5 LS CLR DSL V.R. TLS 350 6,000 120 4 4 4 4 4 99 1/2 5,400 90 4 4 4 4 6 REG V.R TLS 350 20,000 120 4 4 4 4 4 100 18,000 90 4 4 4 4 7 PRM V.R. TLS 350 8,000 120 4 4 4 4 4 97 1/2 7,200 90 4 4 4 4 8 CLR V.R. TLS 350 6,000 120 4 4 4 4 4 99 1/2 5,400 90 4 4 4 4 Max LaRou UT-412 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 1 HS DYE DSL V.R. TLS 350 15,000 120 4 4 4 4 98 4 1.5 4 4 2 LS DYE DSL V.R. TLS 350 6,000 120 4 4 4 4 99 1/2 4 1.5 4 4 3 1LS DYE DSL V.R. TLS 350 6,000 120 4 4 4 4 99 1/2 4 1.5 4 4 4 LS CLR DSL V.R. TLS 350 15,000 120 4 4 4 4 98 4 1.5 4 4 Max LaRou UT-412 01/03/2025 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 5 LS CLR DSL V.R. TLS 350 6,000 120 4 4 4 4 99 1/2 4 1.5 4 4 6 REG V.R. TLS 350 20.000 120 4 4 4 4 100 4 1.5 4 4 7 PRM V.R. TLS 350 8,000 120 4 4 4 4 97 1/2 4 1.5 4 4 8 CLR V.R. TLS 350 6,000 120 4 4 4 4 99 1/2 4 1.5 4 4 Max LaRou UT-412 01/03/2025 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 L1 PRM STP PRM 4 4 4 4 4 4 4 4 L2REG STP REG 4 4 4 4 4 4 4 4 L3 2 CLR STP CLR DSL 4 4 4 4 4 4 4 4 L4 HS DYE STP DYE DSL 4 4 4 4 4 4 4 4 L5 EFree STP E Free 4 4 4 4 4 4 4 4 L6 1 CLR STP CLR DSL 4 4 4 4 4 4 4 4 L7 1LS DYE STP DYE DSL 4 4 4 4 4 4 4 4 Max LaRou UT-412 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Ogden Cardlock 1200563 01/03/2025 L8 2LS DYE DSL DYE DSL 4 4 4 4 4 4 4 4 Max LaRou UT-412 Pressure/Vacuum (P/V) Vent Valve Data Sheet Facility Name: Test Date: Address: Test Company: Precision Testing Technologies City: Tester Name: Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): 2.5" to 6" wc <=0.05 cfh @ 2" wc 2.5" to 6" wc <=0.05 cfh @2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc Ogden Cardlock 01/06/2025 Zak Goldberg UT-435 Clear N/A N/A 4 N/A N/A N/A N/A Reg OPW 523V 4 N/A N/A N/A N/A Premium OPW 523V 4 N/A N/A N/A N/A Ogden Cardlock Zak Goldberg UT-435 01/06/2025