Loading...
HomeMy WebLinkAboutDWQ-2025-001787 LARGE UNDERGROUND WASTEWATER DISPOSAL SYSTEM OPERATING PERMIT Utah Department of Environmental Quality, Division of Water Quality NAME OF SYSTEM:WILLOW PARK CONTACT NAME/ MAILING ADDRESS/ PHONE / EMAIL:Steve Marchbanks / Lehi City / 153 North 100 East Lehi, Utah 84043 / (385) 201-2718 / smarchbanks@lehi-ut.gov SYSTEM LOCATION:9300 West 300 North, Lehi, Utah County, Utah 84043 ISSUE DATE:March 5, 2025EXPIRATION DATE:March 11, 2030 ISSUED BY: _____________________________________________, John K. Mackey, PE, Director, Division of Water Quality Until such time as this permit expires or is modified or revoked, the permittee is authorized to operate a large underground wastewater disposal system (LUWDS) in conformance with all the requirements, limitations, and conditions set forth in Utah Administrative Code R317-5, with the attached schedules as follows: SCHEDULE A Waste Disposal LimitationsThe permittee is authorized to operate and maintain a large underground wastewater disposal system (LUWDS) that hasbeen constructed in accordance with plans and specifications approved by the Division of Water Quality and with the following conditions:System type:Conventional Gravity Conventional with Pump-to-Gravity Pressure Distribution Alternative (describe)_____________________________________________________Maximum Daily Design Flow:6,000 gallons per day (gpd)_____________________________________ Components of wastewater disposal system (check all that apply): Grease Trap ___________________________Septic Tank(s) 1-2500 gal & 2-1750 gal tanksin series Pump Tank w/ Floats____________________ Recirculating Tank________________________ Control Panel___________________________ EffluentTreatment________________________ Distribution Box____________________Distribution Valve________________________ Pressure Distribution____________________Drip Irrigation________________________ Trenches1,254 linear feet x 3’ wide ______Deep Trench_______________________________ Bed__________________________________ Mound_______________________________ Other (describe):________________________________________________________________________ Drainfield media:Gravel;Chambers (Describe)_______________________________________Effluent parameters will meet R317-4 for domestic wastewater or additional treatment may be required. Discharge of untreated or partially treated sewage or septic tank effluent directly or indirectly to the ground surface or to the surface waters of the State of Utah constitutes a public health hazard and is prohibited. This permit does not relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law(s), rule(s) or standard(s). No cooling water, air conditioner water, groundwater, oil, hazardous materials, roof drainage, storm water runoff, or other aqueous or non-aqueous substance which is, in the judgment of the Division, detrimental to the performance of the LUWDS or to groundwater, shall be discharged into the wastewater treatment system.No activities shall be conducted that could cause an adverse impact on existing or potential beneficial uses of groundwater. SCHEDULE B Required Servicing and Inspections 1.AnnuallySemi-Annually (Every 6 months)Other (specify)_______________________________ 2.All servicing and inspections must be conducted by a certified maintenance person per R317-11. Level 2 is required for conventional systems and Level 3 for all other LUWDS. Nameof person performing LUWDS maintenance:Shane Youd___________________________________________ Level 2Level 3Note: Permittee must notify the Division within 30 days if maintenance person is replaced. 3.If sample results exceed Effluent Sampling Parameters (other than flow of wastewater)listed in R317-4-13, Table 7.3, report to the Division within 5days and follow rules in R317-5-9.2.D. Inspection Components TYPE OF SYSTEM Measure sludge/ scum levels, pump when necessary:Septic TankPump TankGrease Trap Inspect and clean when necessary:Pump/FloatsControl PanelPump Filter Flush/ cleanpressure laterals; inspect for ponding or surfacing in drainfield; Adjust squirt height for equal pressure. Follow Manufacturers Recommendations*:RecirculationTankPre-Treatment UnitMiscellaneous Conventional Gravity or Pump-to-Gravity Pressure Distribution or Drip Irrigation Mound, At-Grade Packed Bed *Manufacturer recommendations may require more frequent inspections Minimum Frequency of Periodic Inspections TYPE OF SYSTEM Every 12 months Every 6 months Conventional Gravity or Pump-to-Gravity5,000- 15,000 gal/day15,000 + gal/day At-Grade Alternative System (first 5 years only) Pressure Distribution, Drip Irrigation, or Mound Packed Bed Treatment System (to lower waste strength levels) Monitoring and Reporting Requirements Item or Parameter Minimum Frequency Type of Sample Effluent Discharge Standards Flow of wastewater (gpd) Monthly Estimate based on meter readings Approved design flow (gpd) Reporting Monitoring, maintenance practices, solids handling and results shall be reported on Division approved forms and must be submitted by August 1, following the “reporting year” period of July 1 to June 30. Submit Annual Inspection Reports(via Email, US Mail, or Fax) to: Email: LUWDS@utah.govTelephone: 385-501-9580Fax: 801-536-4301 Mailing Address: Division of Water Quality,c/o LUWDS, PO Box 144870,Salt Lake City,UT 84114-4870 SCHEDULE C Special & General Conditions 1.All septage/sludge shall be managed by a permitted liquid waste operator (septic system pumper) as defined in R317-550 2.Any observations of excessive kitchen wastes, surfacing sewage, etc., shall be reported to the Division within 5 working days. 3.The permittee must maintain all treatment and control facilities in good working order and in conformance with permit requirements.