Loading...
HomeMy WebLinkAboutDERR-2025-001282195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director January 7, 2025 CERTIFIED MAIL RETURN RECEIPT REQUESTED Alan Jenkins Environmental Contractors, Inc. 931 East 800 North Mapleton, Utah 84664 Re: Work Plan and Budget No. NIM-06 Bid Schedule Request Petroleum Storage Tank Fund Magna Mart, located at 8588 West 2700 South, Magna, Utah Facility Identification No. 4000122, Release Site NIM Dear Mr. Jenkins: The Division of Environmental Response and Remediation (DERR) received a revised Work Plan and Budget (WP&B) on September 23, 2024. The WP&B dated September 12, 2024, was prepared by Pure Enviro Management, LLC. The WP&B is for additional subsurface investigation, the replacement of seven on-site wells, and site restoration. As per discussions with your consultant, Pure Environmental, there is insufficient information included in the WP&B to assess costs that may be improvements to the property and which have been included as part of site restoration. Please resubmit a revised WP&B for this work, including an itemized Bid Specification and Schedule, by February 10, 2025. A sample Bid Specification and Schedule has been provided as an example of items reimbursable by the fund, but it is not intended to cover all project requirements. Your engineer should prepare a comprehensive Bid Specification and Schedule for this project with reimbursable costs outlined in the example broken out separately. Pursuant to Utah Admin. Code R311-207-4(8), you are required to obtain a minimum of three competitive bids by responsive bidders, or you must provide an acceptable sole source justification. In order to assist you in obtaining competitive bids, please see the attached list of local contractors. Also, previously submitted WP&Bs included bids that combined projects that included costs to be covered by the owner and costs to be covered by the Petroleum Storage Tank Fund (PST Fund). ERRA-21-24 Facility ID# 4000122 Page 2 Please separate out the work and costs to be covered by the PST Fund for the DERR review. If bidders cannot or will not separate costs in this manner, you may need to obtain separate bids for PST Fund covered work. In accordance with the Cost Guidelines for Utah Underground Storage Tank Sites, costs of upgrading or improving a site are ineligible for reimbursement from the PST Fund. This includes costs associated with redevelopment to meet state and local permitting and code requirements, such as upgrades to structures, curb, gutters, and stormwater drainage, and will remain the responsibility of the property owner. Additionally, the PST Fund cannot cover an improvement that was not present before the remediation project began and bids should clearly show the work being done so a determination of costs that can be reimbursed are easily distinguishable from those that are not reimbursable. If you have any questions, please contact Nicole Chavez, the DERR project manager, at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/NMC/ss Enclosures: Bid Specification and Schedule cc: Dorothy Adams, Executive Director, Salt Lake County Health Department Ron Lund, Environmental Health Director, Salt Lake County Health Department William Moore, Pure Enviro Management, LLC UNIT PRICES Contractor shall complete the portion of the Bid Schedule for listing unit prices, inserting its unit Bid price for each item. The unit Bid price times the quantity determines the total price for each Bid item. The summation of total Bid prices results in the Contract Total Price. In the case of an error in extension, the unit price shall govern. Failure to enter a price for any Bid item will cause the entire Bid to be thrown out as non-responsive. Unit prices shall include all Contractor’s costs, expenses, general conditions, overhead, labor, material, supervision, tools, equipment, insurance, bond premiums, taxes, fringe benefits, coordination and all other necessary costs, including the Contractor’s profit. Unit prices shall not increase by any change in material prices, wage rates or any other escalatory factors and shall remain in effect through the duration of the Remediation Project unless otherwise stated. The Work shall be furnished and installed complete in every respect or deleted from the Work in accordance with the Bid Schedule listed. Unit prices shall be based upon all Work complete in place in accordance with all applicable requirements of the Contract Documents. List of local Wasatch Front companies that could be included in the minimum of three consecutive bids: Company Name Location/Address Telephone ET Technologies Salt Lake City 801-977-0731 Direct Push Services Salt Lake 801-477-7077 Spackman Salt Lake 801-598-7928 Enviro Care North Salt Lake 801-299-1900 Pacific West Salt Lake 480-485-0295 Snap Trucking American Fork 801-830-7745 Bid Schedule No. Item Quantity Estimate Units Unit Price Total 1 Concrete replacement for red outlined area in attached map Ft³ $ $ 2 Concrete grading for red outlined area in attached map Ft³ $ $ 3 Concrete cost for new curb (approx. 72 feet of swell curbing) Ft³ $ $ 4 Trenching associated with the reinstallation and reconnection to the Storm Catch Basin Drain Box Ft $ $ 5 Piping associated with the reinstallation and reconnection to the Storm Catch Basin Drain Box Ft $ $ 6 Permitting costs associated with the reinstallation and reconnection to the Storm Catch Basin Drain Box and associated piping within the red outlined area 1 Lump Sum $ $ 7 Installation and connection cost to surface drain in red outlined area in attached map 1 Lump Sum $ $ Bid Total $ Bid Schedule 1 BID SCHEDULE PART 1 GENERAL 1.01 BIDDER A. Company Name ___________________________________________ B. Company Address _________________________________________ C. Company Phone Number ___________________________________ 1.02 CONSTRUCTION CONTRACT A. Name of Project: Magna Mart Project No. _______________ Contract No. _________________ Bidding No. _________________ 1.02 RELATED REQUIREMENTS A. APWA 01 29 00: Payment Procedure. 1.03 SCHEDULES TO BE ADDED TO THE AGREEMENT A. This Bid Schedule contains the schedules of prices which will be incorporated into the Agreement by reference. It is the intent that these schedules of prices covers all work and materials necessary for all the work shown on the plans. Payment for work items for which no bid item exists shall be considered incidental to and part of the price shown on the bid that such item most nearly accommodates. Payment for all items shall be full compensation for furnishing and installing the item designated. 1.04 SCHEDULES OF PRICES A. Total Price for Schedule 1 – PST Fund Eligible Work $ B. Total Price for Schedule 2 – PST Fund Non-Eligible Work $ C. Total of All Schedules $ Bid Schedule 2 D. Schedule 1: PST Fund Eligible Work (Inside the red line boundary shown on the attached figure) Item No. Specification Reference Number Classification of Unit Price Work Quantity Unit Unit Price Amount 1 Division 1 Mobilization, Traffic Control, Permitting, Survey (North Split) 1 Lump Sum $ $ 2 02 41 13 Remove Concrete Storm Drain Inlet Box 1 Each $ $ 3 02 41 13 Remove 8 Inch C900 PVC Drain Pipe 24 Foot $ $ 4 02 41 13 Remove Concrete Flatwork (Northwest Corner of Store) 79 Square Foot $ $ 5 02 41 13 Remove Concrete Flatwork (Swale Gutter) 72 Foot $ $ 6 02 41 14 Remove Concrete Pavement (North Area) 1,978 Square Foot $ $ 7 02 41 14 Remove Asphalt Pavement (North Area) 3,439 Square Foot $ $ 8 32 01 10 Remove and Replace 6 Foot Chain Link Fence 83 Foot $ $ 9 32 05 10 Parking Lot Grading and Subgrade Preparation (North Area) 5,417 Square Foot $ $ 10 32 11 23 Untreated Base Course (Parking Lot Pavement) (North Area) 134 Cubic Yard $ $ 11 32 13 13 Restore Concrete Pavement (7 Inch Thick) (Parking Lot) (North Area) 5,417 Square Foot $ $ 12 32 17 23 Restore Parking Lot Pavement Markings (North Area) 1 Lump Sum $ $ 13 33 41 00 Concrete Storm Drain Inlet Box 1 Each $ $ Bid Schedule 3 Item No. Specification Reference Number Classification of Unit Price Work Quantity Unit Unit Price Amount 14 33 41 00 8 Inch C900 PVC Storm Drain Pipe 24 Foot $ $ Schedule 1 Total (Enter in Paragraph 1.04) = $______________________________ BID SCHEDULE CONTINUES ON NEXT PAGE Bid Schedule 4 E. Schedule 2: PST Fund Non-Eligible Work (Outside the red line boundary shown on the attached figure, except as noted) Item No. Specification Reference Number Classification of Unit Price Work Quantity Unit Unit Price Amount 1 Division 1 Mobilization, Traffic Control, Permitting, Survey (South Split) 1 Lump Sum $ $ 16 02 41 13 Remove Canopy and Supports to Below Subgrade (South Area) 1 Lump Sum $ $ 17 02 41 14 Remove Concrete Pavement (South Area) 3,391 Square Foot $ $ 18 32 16 13 30” Concrete Curb and Gutter (All) 325 Foot $ $ 19 32 16 13 Concrete Sidewalk (All) 590 Square Foot $ $ 20 32 16 13 Concrete Driveway - 7 Inch Thick (All) 188 Square Foot $ $ 21 31 05 13 Landscape Rock (All) 21 Cubic Yard BY OTHERS 22 32 05 10 Parking Lot Grading and Subgrade Preparation (South Area) 3,391 Square Foot $ $ 23 32 11 23 Untreated Base Course (Parking Lot Pavement) (South Area) 84 Cubic Yard $ $ 24 32 13 13 Restore Concrete Pavement (7 Inch Thick) (Parking Lot) (South Area) 3,391 Square Foot $ $ 25 32 17 23 Restore Parking Lot Pavement Markings (South Area) 1 Lump Sum $ $ 26 32 84 23 Irrigation (All) 1,697 Square Foot BY OTHERS 27 32 84 23 Turf (All) 40 Square Yard BY OTHERS Bid Schedule 5 Item No. Specification Reference Number Classification of Unit Price Work Quantity Unit Unit Price Amount 28 32 93 43 Deciduous Shrub (All) 15 Each BY OTHERS 29 32 93 43 Deciduous Tree (All) 5 Each BY OTHERS 30 33 41 00 Underground Drainage Detention Structure (R- Tank SD or Equal) (All) 828 Cubic Feet $ $ 31 33 41 00 12 Inch C900 PVC Storm Drain Pipe 43 Foot $ $ 32 33 41 00 Catch Basin with Pretreatment Hood 1 Each $ $ 33 33 41 00 Cleanout Box 1 Each $ $ Schedule 2 Total (Enter in Paragraph 1.04) = $______________________________ END OF BID SCHEDULE --R/W I ! I ' i i I ')( e I 0: w w 5 u ffi ~ ---------------- • RIW -------- e MAIN STREET 2'-6• REVERSE CURB ANO GUTTER SEE DETAIL, SHEET C201 REMOVE AND REPLACE EXISTING CURB ANO GUTTER WITH 2'-6• CURB AND GUTTER, TYPE A SEE APWA PLAN NO. 205 LEGEND TYPICAL CURB AND GUTTER END DETAIL SEE DETAIL, SHEET C201 CONCRETE SIDEWALK SEEAPWAPLAN NO. 231 REMOV E AND REPLACE EXISTING PAVEMENT TO EDGE OF BUILDING --------R -----..---RtW ---~---- FLARE DRIVEWAY APPROACH SEE APWA PLAN NO. 221.2 PAVEMENT SEE DETAIL, SHEET C201 ASPHALT CONCRETE PAVEMENT TIE IN SEE APWA PLAN NO. 251 4" SOLID WHITE PAINT SAWCUT PAVEMENT NOTE : DIMENSIONS ARE TO FACE OF CURB UNLESS NOTED OTHERWISE. i i, 1 R/W ~-c-' j a. w ... ;; ~ I SCALE IN FEET =====================================================!:::==:::::IJ D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 1 0 0 . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L B . G O L D I N G 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 EPP MSD MSD MSD MAIN STREET B U C C A N E E R D R I V E N E X I S T I N G S I T E P L A N ELEV= 4251.841 E= 1474872.288 N= 7429249.289 MONUMENT ELEV= 4261.344 E= 1474854.961 N= 7428565.816 CONTROL POINT, NAIL ELEV= 4277.424 E= 1471284.199 N= 7428376.071 SECTION CORNER ELEV= 4280.56 E= 1471283.337 N= 7428287.807 MONUMENT 9180 WEST ELEV= 4264.067 E= 1474842.302 N= 7428364.312 CONTROL POINT, NAIL C100 MSD WV SCALE IN FEET 100 20 30 40 ELEV= 4264.844 E= 1475191.324 N= 7428295.347 CONTROL POINT, NAIL ELEV= 4264.286 E= 1474970.057 N= 7428355.491 CONTROL POINT, NAIL S FASTRAC S BUS S ST BUILDING LIGHT POLE STORM DRAIN, DROP INLET STORM DRAIN, MANHOLE ROOF DRAIN STEEL POLE BOLLARD WATER, HOSE BIB WATER, FIRE HYDRANT WATER, VALVE COLUMN WATER, WELL FENCE SIGN, "FASTRAC" SIGN, STREET SIGN, BUS LEGEND EPP MSD MSD MSD D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 1 0 1 . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L J . R U S B Y 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 MAIN STREET B U C C A N E E R D R I V E N S I T E P L A N LEGEND 1 2 3 SEE DETAIL, SHEET C201 2'-6" REVERSE CURB AND GUTTER 4 5 SEE DETAIL, SHEET C201 TYPICAL CURB AND GUTTER END DETAIL 6 7 8 4" SOLID WHITE PAINT SEE APWA PLAN NO. 205 AND GUTTER, TYPE A CURB AND GUTTER WITH 2'-6" CURB REMOVE AND REPLACE EXISTING SEE APWA PLAN NO. 231 CONCRETE SIDEWALK SEE DETAIL, SHEET C201 PAVEMENT SEE APWA PLAN NO. 251 ASPHALT CONCRETE PAVEMENT TIE IN 9 SAWCUT PAVEMENT SEE APWA PLAN NO. 221.2 FLARE DRIVEWAY APPROACH C101 UNLESS NOTED OTHERWISE. DIMENSIONS ARE TO FACE OF CURB NOTE: SCALE IN FEET 100 20 30 40 13'-0"11'-3" 2 4 ' - 0 " 9'-0" 8'-0" 75'-0" 1 3 ' - 8 " 1 0 6 ' - 9 " 10'-0"7'-8" 1 4 '- 0 " 1 8 '- 8 " 3 6 3'-0" 3'-0" 3 7 4 3 3 1 1 2 5 6 8 8 22'-9" 1 8 ' - 0 " 2 2 ' - 3 " 21'-9" 9 7'-0" 9'-0" TYP. 4'-0" EXISTING GUTTER EXISTING GUTTER OF BUILDING EXISTING PAVEMENT TO EDGE REMOVE AND REPLACE 10 BELOW SUBGRADE REMOVE CANOPY AND SUPPORTS TO M K S U P D A T E T O C A N O P Y A R E A B A G 0 1 / 2 1 / 2 0 2 5 10 10 EXISTING BUILDING EPP MSD MSD MSD M M M D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 1 0 2 . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L J . R U S B Y 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 N G R A D I N G A N D D R A I N A G E C102 1 2 3 4 Y= GRATE ELEV. X = PIPE INVERT ELEV. SEE APWA PLAN NO. 332.1 2'x 3' CLEANOUT BOX CATCH BASIN 15" RCP STORM DRAIN PIPE SEE DETAIL, SHEET C202 CATCH BASIN BOX CONTROL Y= SOLID LID ELEV. X = PIPE INVERT ELEV. Y= SLOPE X= LENGTH8" C900 PVC STORM DRAIN PIPE Y= TOP OF R-TANK X= BOTTOM OF R-TANK LEGEND4263.56 TOA X 4263.19 TOA X 4263.35 TOA X 4263.73 TOA X 4264.35 TOA X 4264.65 TOA X 4264.09 TOA X 4264.24 TOA X 4263.90 TOA X 4263.60 TOA X 4263.80 TOA X 4263.80 TOA X 4264.50 TOA X MATCH EXIST. 4264.41 TOA X MATCH EXIST. 4264.37 TOA X 4263.77 TOAX 4263.72 TOA X 4263.4 TOA X 4263.56 TOA X 4263.67 TOA X 4263.67 TOA X 4263.03 TBC X 4262.93 TBC - LOW X 4263.25 TBC - LOW X 4264.07 TBC X MATCH EXIST. 4264.28 TOA X MATCH EXIST. 4263.79 TOA X MATCH EXIST. 4263.52 TOA X 4264 4 2 6 4 4 2 6 4 4 2 6 4 0.0% -0.5% -0.5% -2.25% - 0 . 8 9 % -1 .6% - 1 . 0 % -0.4% -0 . 7 % -2 . 5 % -0 . 9 % 4264.00 TOA X 4263.49 TOA X 1 3 4 5 4261.81 PRETREATMENT HOOD 4263.06 23.68' 0.5% 14.4 1.0% I.E. 4261.69 I.E. 4261.74 I.E. 4261.50 MAIN STREET B U C C A N E E R D R I V E -1 . 0 % -0.4 % -1 . 0 % 4263.20 TBC X 4263.75 TBC X 3 4.0' 1.0% 2 STORAGE CAPACITY 828 CU. FT. REQ'D 4263.20 4261.69 SCALE IN FEET 100 20 30 40 4264.22 TOA X 4264.41 TOA X -1.5% -1.9% -1.9 % -2.6% -3.2 % -3.5%-1.0%-3.6%-5.0 % -1.6% -1.2% DOWNSPOUT DRAIN EXISTING ROOF EXISTING GUTTER REMOVE AND REPLACE 4264.89 FLOOR FINISHED FOR DESIGN STORM EVENT HIGHWATER ELEV. 4263.16 5 R-TANK "DOUBLE" SD OR EQUAL UNDERGROUND DRAINAGE DETENTION STRUCTURE Y= TOP OF R-TANK X= BOTTOM OF R-TANK MOUNTED TO SOUTH WALL 2 INCH DIA ORIFICE PLATE WITH 4265.33 4261.64 D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 1 0 3 . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L B . G O L D I N G 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 EPP MSD MSD MSD MAIN STREET B U C C A N E E R D R I V E N S E D I M E N T A N D E R O S I O N C O N T R O L ELEV= 4251.841 E= 1474872.288 N= 7429249.289 MONUMENT ELEV= 4261.344 E= 1474854.961 N= 7428565.816 CONTROL POINT, NAIL ELEV= 4277.424 E= 1471284.199 N= 7428376.071 SECTION CORNER ELEV= 4280.56 E= 1471283.337 N= 7428287.807 MONUMENT 9180 WEST ELEV= 4264.067 E= 1474842.302 N= 7428364.312 CONTROL POINT, NAIL C103 MSD WV SCALE IN FEET 100 20 30 40 ELEV= 4264.844 E= 1475191.324 N= 7428295.347 CONTROL POINT, NAIL ELEV= 4264.286 E= 1474970.057 N= 7428355.491 CONTROL POINT, NAIL S FASTRAC S BUS S ST BUILDING LIGHT POLE STORM DRAIN, DROP INLET STORM DRAIN, MANHOLE ROOF DRAIN STEEL POLE BOLLARD WATER, HOSE BIB WATER, FIRE HYDRANT WATER, VALVE COLUMN WATER, WELL FENCE SIGN, "FASTRAC" SIGN, STREET SIGN, BUS 1 2 3 SILT FENCE 4 CONCRETE WASHOUT ON-SITE PORTABLE RESTROOM DUMPSTER 5 STABILIZED ROADWAY ENTRANCE 2 3 4 5 1 1 1 1 LEGEND D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 1 0 4 . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L J . R U S B Y 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H MAIN STREET B U C C A N E E R D R I V E N J O I N T L A Y O U T P L A N C104 UNLESS NOTED OTHERWISE. DIMENSIONS ARE TO FACE OF CURB NOTE: SCALE IN FEET 100 20 30 40 M K S U P D A T E T O C A N O P Y A R E A B A G 0 1 / 2 1 / 2 0 2 5 (SIKAFLEX OR EQUAL) JOINT SEALANT SAWCUT JOINTCLASS 4000 CONCRETE UNTREATED BASE COURSE CONTROL JOINT TYP EXPANSION BOARD EXPANSION BOARD EXPANSION BOARD EXPANSION BOARD EXISTING BUILDING 1 / 3 D 7 " 8 " CONTROL JOINT JOINT LAYOUT PLAN D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 7 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 2 0 1 _ D e t a i l s . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L B . G O L D I N G 2 7 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 Know what'sbelow. before you dig.Call R 6 " 8 " 2'-0"6" 2'-6" 6 " 6 " 1 ' - 2 " LOT EXCAVATE CLAY AND REPLACE WITH GRANULAR BORROW FILL IF CLAY POCKETS ARE ENCOUNTERED IN EXCAVATING THE PARKING 1. "2 11 "2 1R=1 6" UNTREATED BASE COURSE BASE COURSE 8" UNTREATED 2'-6" CURB & GUTTER OR FLATTER TRANSITION FLOWLINE TO GRADE SURFACE ASPHALT CONCRETE 1 10 D E T A I L S C201 PAVEMENT NOTES: PAVEMENT 3 - TYPICAL CURB AND GUTTER END DETAIL 1 - 2'-6" REVERSE CURB AND GUTTER 2 " 6" UNTREATED BASE COURSE CONCRETE 7" CLASS 4000 PAVEMENT SECTION 2 - M K S U P D A T E P A V E M E N T B A G 0 1 / 2 1 / 2 0 2 5 D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 2 0 2 _ D e t a i l s . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L B . G O L D I N G 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 A A B B 3" 8 " OR APPROVED EQUAL D&L SUPPLY FU-3136 BICYCLE SAFE GRATE AND FRAME 3" 3 " 6"6" 6 " 3'-0" 3 ' - 0 " 3'-0" 2'-6" 2 ' - 6 " S E E U T I L I T Y P L A N S H E E T V A R I E S EACH WAY #5 BARS @ 12" O.C. 3 " MATCH GRADE SLOPE LID TO OR APPROVED EQUAL D&L SUPPLY FU-3136 BICYCLE SAFE GRATE AND FRAME EACH WAY #5 BARS @ 12" O.C. Know what'sbelow. before you dig.Call R ACCESS PORT, 6" OPENING REMOVABLE WATERTIGHT PIPE ADAPTER 1" PVC ANTI-SIPHON PIPE ADAPTER 1" PVC ANTI-SIPHON (HIDDEN) OUTLET PIPE DRILLED HOLE (NARROW END OUT) EXPANSION CONE ANCHOR SHIELD STAINLESS BOLT (TRIM TO LENGTH) PSA BACKING FOAM GASKET W/ MOUNTING FLANGE (SEE DETAIL A) ANCHOR W/ BOLT (SEE DETAIL B) STRUCTURE BETWEEN HOOD AND GASKET COMPRESSED DISTANCE OF 6" FOR PIPES 12" I.D. DISTANCE EQUAL 1/2 THE OUTLET PIPE DIAMETER WITH A MINIMUM 5. THE BOTTOM OF THE HOOD SHALL EXTEND DOWNWARD A OUTLET PIPE SIZE AS PER MANUFACTURER'S RECOMMENDATION. 4. THE SIZE AND POSITION OF THE HOOD SHALL BE DETERMINED BY (SEE CONFIGURATION DETAIL) PORT, A MOUNTING FLANGE, AND AN ANTI-SIPHON VENT AS DRAWN. 3. ALL HOODS SHALL BE EQUIPPED WITH A WATERTIGHT ACCESS MINIMUM 0.125" LAMINATE THICKNESS. RESIN COMPOSITE WITH ISO GEL COAT EXTERIOR FINISH WITH A 2. ALL HOODS SHALL BE CONSTRUCTED OF A GLASS REINFORCED OR PRE-APPROVED EQUAL WEB SITE: www.bmpinc.com TOLL FREE: (800) 504-8008 OR (888) 354-7585 (860) 434-0277, (860) 434-3195 FAX LYME, CT 06371 53 MT. ARCHER RD. BEST MANAGEMENT PRODUCTS, INC. QUALITY STRUCTURES SHALL BE AS MANUFACTURED BY: ALL HOODS AND TRAPS FOR CATCH BASINS AND WATER 1. MINIMUM DISTANCE FOR PIPES <12" I.D. IS 6". OUTLET PIPE DIAMETER (MIN.) BELOW THE PIPE INVERT. 2 1OF IS A DISTANCE POSITION HOOD SUCH THAT BOTTOM FLANGE DIA.2 1 MOUNTING FLANGE 10. SEAL HOOD AROUND ORIFICE PLATE WITH WATER TIGHT SEAL. ANCHOR SHIELDSE. STAINLESS STEEL BOLTS " 8 3OIL-RESISTANT CRUSHED CELL FOAM GASKET WITH PSA BACKING C. PVC ANTI-SIPHON VENT PIPE AND ADAPTER B. INSTALLATION INSTRUCTIONS A. INSTALLATION KIT SHALL INCLUDE: MANUFACTURER SUPPLIED INSTALLATION KIT. INSTALLATION INSTRUCTIONS SHALL BE FURNISHED WITH 9. BY MANUFACTURER. (SEE INSTALLATION DETAIL) 3/8" STAINLESS STEEL BOLTS AND OIL-RESISTANT GASKET AS SUPPLIED 8. THE HOOD SHALL BE SECURELY ATTACHED TO STRUCTURE WALL WITH BE FINISHED SMOOTH AND FREE OF LOOSE MATERIAL. THE SURFACE OF THE STRUCTURE WHERE THE HOOD IS MOUNTED SHALL 7. AND A MAXIMUM OF 24" ACCORDING TO STRUCTURE CONFIGURATION. THE ANTI-SIPHON VENT SHALL EXTEND ABOVE HOOD BY MINIMUM OF 3" 6. 3 ' - 0 " PROCEDURES. MANUFACTURERS RECOMMENDED WITH PRETREATMENT HOOD FOLLOW MINIMUM SUMP DEPTH OF 12", OR * C202 D E T A I L S PRETREATMENT HOOD PRETREATMENT HOOD NOTES: CONFIGURATION DETAIL INSTALLATION NOTE: DETAIL B DETAIL A SIDE VIEW FRONT VIEW CATCH BASIN BOX SECTION B-B SECTION A-A PLAN VIEW OUTLET PIPE 3 ' - 0 " 2'-0" SLOPE SLOPE 4 - ORIFICE PLATE WHERE SHOWN IN PLAN. DEBRIS SNOUT INSTALLATION PLATE TO FACILITATE OIL DRILL HOLES IN ORIFICE NOTE: BOLT WITH NUT (TYP-4) "2 1" x 12 1BOLT PLATE USING " Ø BOLT2 14 EACH " STEELPLATE4 1 Ø 8" C900 PVC Ø 2" 33" 6 -HOOD PRETREATMENT 6 " 6 " 5 - 6 - D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 2 0 3 _ D e t a i l s . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L B . G O L D I N G 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 Know what'sbelow. before you dig.Call R (USE CLASS GW, GP, SW, OR SP). MUST BE FREE OF LUMPS AND DEBRIS. ") OR SOIL 2 1MAY BE STONE (< 1 3" COMPACTED BEDDING MATERIAL FINISH GRADE 7 - UNDERGROUND DRAINAGE DETENTION STRUCTURE OVERLAP 12" MIN AT ALL JOINTS 8 OZ. NON-WOVEN GEOTEXTILE " FRAME AND COVER4 116 STORM DRAIN PIPE 8 INCH C900 PVC MAINTENANCE PORT 12" DIA. PVC SEE PLAN SHEETS 828 CU. FT. REQ'D DIMENSIONS / STORAGE VOLUME R-TANK SD OR EQUAL OR EQUIVALENT PLATE PLASTIC, SLATE NON-CORROSIVE SOLID SEE PATTERN NOTCH BOTTOM OF PIPE NON-CORROSIVE HOSE CLAMP 1" +/- VENTING PERFORATIONS STANDARD PROCTOR DENSITY BACKFILL COMPACTED TO 95% GEOTEXTILE NOTE: EXISTING BUILDING FINISHED FLOOR ELEVATION 4264.89 PIPE-NOTCHING PATTERN T Y P I C A L 1 8 . 1 2 " (8 OPENINGS TOTAL) 8" NOTCHES CUT IN SHADED AREAS "2 11 2'-0"STORM DRAIN PIPE 8 INCH C900 PVC FINISH GRADE C203 D E T A I L S SCALE IN FEET 1.50 3 4.5 6 ELEV. 4263.20 M I N 1 8 " FOR DESIGN STORM EVENT 4263.16 HIGH WATER ELEVATION ELEV. 4261.69 ELEV. 4261.69 ELEV. 4261.69 ELEV. 4263.20 SCALE x2 D A T E C H E C K E D B Y D R A W N B Y D E S I G N E D B Y 2 4 - J A N - 2 0 2 5 D G N F i l e : L : \ 2 0 2 2 \ 0 0 6 _ A l a n J e n k i n s C o m m e r c i a l L o t L i m i t e d S i t e P l a n \ C a d \ S h e e t _ F i l e s \ 2 0 2 2 0 5 - 0 0 6 _ C 3 0 1 _ D e t a i l s . d g n 123456 A U T H O R I Z E D B Y N O . M A D E B Y D A T E R E V I S I O N P R O J E C T N O . DRAWING NO. 8 5 8 8 W . M A G N A M A I N S T R E E T A L A N J E N K I N S C O M M E R C I A L B . G O L D I N G 2 4 - J A N - 2 0 2 5 2 0 2 1 0 5 - 0 0 7 S . A . H E N D R I C K S M . K . S M I T H S TA TE OF U TAHSEAL ELECTRONIC P R O F ESSIONAL E N GI N E E R No. 6288195 SMITH KIMBALL MATTHEW 07/14/2022 SECTION PERSPECTIVE VIEW SECTION Know what'sbelow. before you dig.Call R 6 ' M A X . 2 ' - 6 " SHEET FLOW PAVED PUBLIC ROAD SEE DETAIL, THIS SHEET SILT FENCE MIN. 8" THICK 20' RAD. COARSE AGGREGATE 2" TO 4" SIZE (NOTE 3C) SEDIMENT FABRIC UNDER GRAVEL 15' M IN. STABILIZED ROADWAY ENTRANCE NOTES: SHIFTS TO KEEP PAVED ROADWAY CLEAN. ENTERING/LEAVING THE SITE. SWEEP AS NEEDED DURING THE END OF EACH SHIFT WHEN CONSTRUCTION VEHICLES ARE SWEEP ROADWAY AND CLEAN UP ANY OFF-TRACKED SOIL AT 5. ACTIVITIES. EXPAND STABILIZED AREA AS REQUIRED TO ACCOMMODATE F. INSTALL ADDITIONAL CONTROLS AS NECESSARY. INSPECT ADJACENT AREAS FOR SEDIMENT DEPOSIT AND E. BUILDUP. INSPECT DAILY FOR LOSS OF GRAVEL OR SEDIMENT D. STRUCTURES USED TO TRAP SEDIMENTS. REQUIRED, AS CONDITIONS DEMAND, AND REPAIR ANY PERIODIC TOP DRESSING WITH 2 INCHES STONE MAY BE C. RIGHT OF WAY. PREVENT TRACKING OR FLOW OF MUD INTO THE PUBLIC B. STONES. REQUIRES PERIODIC TOP DRESSING WITH ADDITIONALA. MAINTENANCE:4. MORE THAN 3 MONTHS). (RECOMMENDED FOR ENTRANCE AREA THAT REMAINS PLACE FILTER FABRIC UNDER STONE IF DESIRED C. COMPACT SUBGRADE.B. SLOPE OF 1 PERCENT AWAY FROM PAVED ROADWAY. CLEAR AND GRUB AREA AND GRADE TO PROVIDE MAXIMUMA. SECTION 01 57 00. INSTALLATION/APPLICATION CRITERIA: REFER TO APWA 3. EQUIPMENT ENTER THE PUBLIC RIGHT OF WAY. APPLICATION: AT ANY SITE WHERE VEHICLES AND 2. ACCESS TO THE SITE. FOR CONTROLLING EQUIPMENT AND CONSTRUCTION VEHICLE DESCRIPTION: A TEMPORARY STABILIZED PAD OF GRAVEL 1. SILT FENCE NOTES: OR WATER BODY. IN AREAS THAT HAVE BEEN SEEDED AND MULCHED, REMOVE SILT FENCE UNLESS THEY ARE PROTECTING A WETLAND 9. AREA APPROVED BY THE ENGINEER. WHEN A STORM EVENT DEPOSITS SEDIMENT BEHIND THE FENCE, REMOVE THE SEDIMENT AND PLACE IT IN A STABLE 8. AREAS HAVE BEEN VEGETATED. MAINTAIN A PROPERLY FUNCTIONING SILT FENCE THROUGHOUT THE DURATION OF THE PROJECT OR UNTIL DISTURBED 7. IN THE END POSTS, OVERLAP THE END POSTS AND TWIST 180 DEGREES. AVOID USING SPLICES ALONG THE FENCE AS MUCH AS POSSIBLE. IF A SPLICE IS NECESSARY, BEFORE POUNDING 6. CUT DITCHES). DO NOT PLACE SILT FENCE ACROSS POTENTIAL CONCENTRATED FLOWS (e.g., PIPE OUTLETS, DRAINAGE CHANNELS, 5. TO PREVENT RUNOFF FROM FLOWING AROUND THE ENDS OF THE SILT FENCE, RUN THE ENDS OF THE FENCE UP SLOPE.4. WHEN EXCAVATING THE TRENCH, USE MACHINERY THAT WILL MINIMIZE DISTURBANCE.3. INSTALL A SEDIMENT TRAP. POSSIBLE. WHERE EXCESSIVE RUNOFF WILL ACCUMULATE AT A LOW POINT, PROVIDE AN OPENING IN THE FENCE AND TO AVOID CREATING LOW POINTS ALONG THE SILT FENCE, ALIGN THE FENCE ALONG THE CONTOUR AS MUCH AS 2. WHERE PERMITTED, POSITION THE SILT FENCE 5' BEYOND THE TOE OF SLOPE.1. MINIMUM WOOD POST 2" SQUARE BY 4' OF SILT FENCE GROUND ON BACKSIDE DO NOT DISTURB 1 ' - 6 " DISLODGE IT. ON THE TOP OF THE FENCE SHOULD NOT INSTALLATION, FIRMLY PULLING UPWARD FENCE SECURELY IN THE GROUND. AFTER ENTRENCH THE BOTTOM 12" OF SILT CONSTRUCTION SITE SHEET FLOW FROM FASTENED TO POST 3' WIDE FILTER FABRIC W A SH D O W N 5 0' MI N. PLAN VIEW ARE EVIDENT SUCH THAT NO GAPS PLACE GRAVEL BAGS FLOW FLOW SEDIMENT SEPARATION PONDING AREA FOR CURB INLET BACK OF CURB BASIN CATCH WHEN NOT LOCATED IN CURB ENCIRCLE CATCH BASIN OR GRAVEL BAGS TO EXTEND GRAVEL WATTLE WHEN INSTALLING CURB INLET PROTECTION DEVICES, NEVER BLOCK THE CURB INLET.4. BE REMOVED FROM THE TRAVELED WAY IMMEDIATELY. INSPECT BARRIERS AND REMOVE SEDIMENT AFTER EACH STORM EVENT, SEDIMENT AND GRAVEL MUST 3. SMALLER) GRAVEL. BAGS MUST BE LAYERED SUCH THAT NO GAPS ARE EVIDENT. USE SAND BAGS OF WOVEN GEOTEXTILE FABRIC (NOT BURLAP) AND FILL WITH 1/2 INCH (OR 2. SEDIMENT TO SEPARATE FROM RUNNOFF. PLACE GRAVEL BAG BARRIER ON GENTLY SLOPING STREET, WHERE WATER CAN POND AND ALLOW 1. DROP INLET BARRIER NOTES: CURB INLET WHEN NOT LOCATED IN CURB ENCIRCLE CATCH BASIN OR GRAVEL BAGS TO EXTEND GRAVEL WATTLE TOP OF CURB NOT BE HIGHER THAN GRAVEL BAG SHOULD BASIN CATCH C301 S W P P D E T A I L S 10 - STABILIZED ROADWAY ENTRANCE 9 - DROP INLET BARRIER 8 - SILT FENCE 3/29/2022 24"X36" 1/8" = 1'-0" 11"X17" 1/16" = 1'-0" NORTH 3/29/2022 24"X36" 1/8" = 1'-0" 11"X17" 1/16" = 1'-0" NORTH TYP. NO SOIL ON TOP OF ROOTBALL TYP. BARRIER FABRIC "DEWITT CO. PRO 5" LANDSCAPE ROCK, SEE SITE PLAN AND DETAILS WIDTH VARIES 3"(SEE PLAN) 3/8" MINUS LANDSCAPE ROCK NOTE: APPLY PRE-EMERGENT HERBICIDE PRIOR TO INSTALLATION CONTRACTOR SHALL PROVIDE SAMPLE TO OWNER FOR APPROVAL PERMA-BARK ROCK STAKER PARSONS 801-409-9500 BARRIER FABRIC "DEWITT CO. PRO 5" LANDSCAPE ROCK, SEE SITE PLAN AND DETAILS TREE BASE PROTECTION NO SOIL ON TOP OF ROOTBALL TYP. BARRIER FABRIC "DEWITT CO. PRO 5" 3/29/2022 NTS Landscape Rock Detail NTS Planting Detail NTS Tree Planting Detail 24"X36" 1/8" = 1'-0" 11"X17" 1/16" = 1'-0" NORTH 3/29/2022 NTS Backflow Prevention NTS Irrigation Controller NTS Xeribug Emitter NTS Pipe Sleeving Detail NTS Trench Detail NTS Drip Valve Detail 24"X36" 1/8" = 1'-0" 11"X17" 1/16" = 1'-0" NORTH Project Name:Drink Shop - Jenkins Project Address:8588 W Magna Main A/P #:000335 Dear Alan Jenkins, $1,912.73 $0.00 TOTAL $1,912.73 INCLUDED WITH BOND AGREEMENT (not due with this document) $100.00 Engineering Bond Amount:$42,505.00 TOTAL $42,605.00 Respectfully, Jefferson Thomson, EIT Development Review Engineer November 9, 2022 Below is a summary of the outstanding Engineering fees due at this time: FEES DUE AT THIS TIME Final Engineering Review Fee: 3rd Party Review Fee: Your immediate attention to these items will help avoid undue delays to receiving FINAL APPROVAL. If you have any questions or concerns, I may be contacted at (385) 468-6614 or jethomson@slco.org This letter is to inform you that the Drainage Plan for your project has been reviewed and found to be in conformity with Salt Lake County Standards. Prior to receiving FINAL APPROVAL from Engineering, it is necessary for you to sign the Urban Hydrology Requirements Agreement and pay for all remaining Engineering fees. A draft copy of the document is provided for your review and comment. Within the Urban Hydrology Requirements Agreement are: a summary of the outstanding engineering fees that are due at this time, the hydrology requirements for the project (see Attachment A), and the calculations for the Final Engineering Review When the above items are complete, your approval will be forwarded to Planning Services. Please be advised that Salt Lake County Ordinances require payment of all fees and posting of bonds prior to the approval of subdivision plats or issuance of building permits. A copy of the Engineering bond calculation has also been provided with this letter for your reference. This bond amount will be included in the overall bond calculation for the bond agreement document, which the County will prepare for you. Bond Processing Fee: Jenny Wilson Mayor Catherine Kanter Deputy Mayor of Operations Scott R. Baird, P.E., Director,Public Works and Municipal Services Kade D. Moncur, P.E., CFM, Director, Public Works Engineering cc: Subdivision Engineer Developer Inspection Services Urban Hydrology Project File Project Name: Drink Shop - Jenkins Date Approved: Project Address: 8588 W Magna Main A/P #: 000335 Applicant: Alan Jenkins $1,912.73 $0.00 $1,912.73 INCLUDED WITH BOND AGREEMENT (not due with this document) $100.00 $42,505.00 $42,605.00 SIGNATURE: REPRESENTING: DATE: received a copy thereof. I also acknowledge that I must inform my contractor, engineer, architect and all other agents of these requirements. do hereby certify that I have read the same, acknowledge that I shall adhere to these requirements, and have Engineering Bond Amount: (385) 468-6600 November 9, 2022 URBAN HYDROLOGY REQUIREMENTS AGREEMENT I, the undersigned, am the developer or the authorized representative of the project for which approval is given, and FEES DUE AT THIS TIME Final Engineering Review Fee: 3rd Party Review Fee: TOTAL Urban Hydrology approval of the drainage system proposed for this application is based upon the engineering review of the drainage and grading plans and the resulting requirements on the proceeding ATTACHMENT A. The requirements listed, together with the final plans, comprise the drainage approval. When infrastructure costs are involved, the applicant may be required to post a performance bond as a condition of approval. This development is subject to Title XVII, Chapter 17.20, of the revised Salt Lake County Ordinance which pertains to payment of storm drainage impact fees. Those fees and/or bonds which may appear below are in conformity with this Ordinance and the attached assessment data sheet (Attachment B). All fees must be paid and bonds posted (as required) prior to the approval of subdivision plats or issuance of building permits. Fee and bond amounts appear on FINAL approvals only. TOTAL Bond Processing Fee: Engineering Division 2001 South State Street Suite N3-600 Salt Lake City, Utah 84190 OFFICE OF PUBLIC WORKS AND MUNICIPAL SERVICES cc: Subdivision Engineer Developer Inspection Services Urban Hydrology Project File ATTACHMENT A Urban Hydrology Requirements Agreement Project Name:Drink Shop - Jenkins Project Address:8588 W Magna Main A/P #:000335 HYDROLOGY REQUIREMENTS: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. All public storm drain facilities and private facilities which directly connect to the public storm drain system or facility are required to have a pipe condition assessment performed using CCTV per Section 33 08 00 of the current Manual of Standard Specifications from APWA. OFFICE OF PUBLIC WORKS AND MUNICIPAL SERVICES Engineering Division 2001 South State Street Suite N3-600 Salt Lake City, Utah 84190 (385) 468-6600 The developer, his engineer and contractor shall meet with Salt Lake County inspectors two days prior to commencing construction of any irrigation or drainage systems. Call Ron Coshow at (801) 833-9819 to coordinate this meeting. The inspector will have the developer's copy of the approved site plans. Prior to any excavation or construction within an existing county right-of-way, the developer shall obtain an "Excavation Permit" as per Chapter 14.16 of the Revised Ordinances of Salt Lake County. Contact Engineering and Flood Control Services at (385) 468-6600 for more information. The developer shall be responsible for all costs incurred due to utility conflicts. Any design modifications resulting from utility conflicts must be submitted to Greater Salt Lake Municipal Services District and approved in writing by the Engineering Division prior to acceptance of improvements. The developer shall grade the property in accordance with the approved site grading and lot drainage plan so as to direct storm water to an approved public facility or to permanently retain all generated water on the subject property both during and after construction. All storm water generated from the project shall be maintained so as not to discharge any additional storm water onto adjacent properties or pond at the end of the curb and gutter. All outstanding balances for the 3rd Party Review Fee, Engineering Checking Fee, and Bond Processing Fee shall be paid at the Planning and Development Services Office prior to the approval of subdivision plat or issuance of building permit. A performance bond for this project shall be posted and processed through the Development Services Office prior to the approval of subdivision plat or issuance of building permit. For additional information, please contact Chara Ellis at (385) 468-6678. The drainage system designed by Matthew Kimball Smith, P.E., License No. 6288195, and stamped 'Approved' by Greater Salt Lake Municipal Services District shall be constructed as shown. Any changes, additions or deletions to the approved plans must be submitted to Greater Salt Lake Municipal Services District and approved in writing by the Engineering Division prior to commencing construction. Reinforced concrete pipe sizes referred to herein are based on class 3, rubber gasket reinforced concrete pipe, and shall have a minimum of one-foot of cover. Cleanouts shall be at maximum 400-foot intervals. Two feet of fill shall be placed over the crown of the reinforced concrete pipe during construction activities to protect against extremely high loads created by construction vehicles. The fill shall be graded to final grade with minimum one-foot of cover over pipe after heavy equipment has left the project. All catch basins and cleanout boxes shall be constructed to County standards. See Salt Lake County Public Works Standard Plans for details. All boxes shall be poured in place in accordance with the above standard drawings. Installation of pre-cast boxes is allowed in private storm drain and irrigation systems that are not within the public right-of-way or within development access roads. cc: Subdivision Engineer Developer Inspection Services Urban Hydrology Project File 1 of 2 ATTACHMENT A Urban Hydrology Requirements Agreement 13. 14. 15. 16. All cleanout boxes and catch basins that are part of a public storm drain system or within the public right-of- way shall conform to the current Standard Plans for Public Works Construction , published by Salt Lake County. Cleanout boxes and catch basins shall be inspected in the field by Salt Lake County inspectors prior to pouring concrete. Pre-cast boxes are not allowed except by Salt Lake County Certified manufacturers. Salt Lake County does not assume any ownership or liability for private storm drain or irrigation systems. The Developer shall assume all responsibility for the maintenance, operation and safety of private storm drain and irrigation systems associated with the project. Bonds on detention basins will not be released until a certified as-built survey is received and approved by this Division. GIS data to be submitted as part of as built drawings. Prepared by: Jefferson Thomson, EIT Development Review Engineer November 9, 2022 cc: Subdivision Engineer Developer Inspection Services Urban Hydrology Project File 2 of 2 ATTACHMENT B Urban Hydrology Requirements Agreement Project Name: Drink Shop - Jenkins Date Approved: November 9, 2022 Project Address: 8588 W Magna Main A/P #: 000335 Applicant: Alan Jenkins $0.00 N/A $0.00 Bond Total: $42,505 Engineering Checking Fee: $1,912.73 4.5% x Bond Total Previously Paid Amount (w/ application): $0.00 Engineering Checking Fee Balance:$1,912.73 Comments: OFFICE OF PUBLIC WORKS AND MUNICIPAL SERVICES Engineering Services 2001 South State Street Suite N3-600 Salt Lake City, Utah 84190 (385) 468-6600 FEE ASSESSMENT 3RD PARTY REVIEW 3rd Party Review Fee: ENGINEERING CHECKING FEE BALANCE cc: Subdivision Engineer Developer Inspection Services Urban Hydrology Project File 1 of 1 Project Name: Drink Shop - Jenkins Date Approved: November 9, 2022 Project Address: 8588 W Magna Main A/P #: 000335 Applicant: Alan Jenkins QUANTITY UNITS DESCRIPTION UNIT COST COST STORM DRAINAGE - PRIVATE 828 CF Underground Detention $15.00 $12,420.00 28 LF 12" C900 Storm Drain Pipe $100.00 $2,800.00 1 EA 3X3 Catch Basin with Snout $8,000.00 $8,000.00 1 EA 2X3 Catch Basin/Cleanout with Orifice $4,000.00 $4,000.00 SUBTOTAL $27,220.00 STORM DRAINAGE - PUBLIC 15 LF 15" RCP Pipe $150.00 $2,250.00 1 EA Connection to Existing System $500.00 $500.00 SUBTOTAL $2,750.00 STREET IMPROVEMENTS - PRIVATE 218 LF Reverse Pan Curb and Gutter $30.00 $6,540.00 SUBTOTAL $6,540.00 STREET IMPROVEMENTS - PUBLIC 107 LF APWA Plan #205 Curb and Gutter Type A $30.00 $3,210.00 107 LF Remove Curb and Gutter $5.00 $535.00 1 EA Drive Approach $2,250.00 $2,250.00 SUBTOTAL $5,995.00 Estimate by: JLT TOTAL $42,505.00 (385) 468-6600 ENGINEERING BOND OFFICE OF PUBLIC WORKS AND MUNICIPAL SERVICES Engineering Services 2001 South State Street Suite N3-600 Salt Lake City, Utah 84190 cc: Subdivision Engineer Developer Inspection Services Urban Hydrology Project File 1 of 1 By: MKS/SVL MAGNA MART ITEMIZED BID SCHEDULE / ENGINEER'S ESTIMATE OF PST FUND ELIGIBLE AND NON-ELIGIBLE COSTS ALAN JENKINS COMMERCIAL LOT 8588 W MAGNA MAIN Updated 2025/01/10 SCHEDULE 1 - PST FUND ELIGIBLE COSTS (BOUNDED BY RED OUTLINE ON MAP) NO.ITEM APWA SPEC.QUANTITY UNIT UNIT PRICE AMOUNT 1 MOBILIZATION, TRAFFIC CONTROL, PERMITTING, SURVEY (North Split)DIVISION 1 1 LUMP $15,000.00 $15,000.00 2 REMOVE CONCRETE STORM DRAIN INLET BOX 02 41 13 1 EACH $500.00 $500.00 3 REMOVE 8 INCH C900 PVC STORM DRAIN PIPE 02 41 13 24 FOOT $20.00 $480.00 4 REMOVE CONCRETE FLATWORK (NORTHWEST CORNER OF STORE)02 41 13 79 SQ. FT.$3.50 $276.50 5 REMOVE CONCRETE FLATWORK (SWALE GUTTER)02 41 13 72 FOOT $13.00 $936.00 6 REMOVE CONCRETE PAVEMENT (North Area)02 41 14 1,978 SQ. FT.$2.50 $4,945.00 7 REMOVE ASPHALT PAVEMENT (North Area)02 41 14 3,439 SQ. FT.$1.80 $6,190.20 8 REMOVE AND REPLACE 6 FOOT CHAIN LINK FENCE 32 01 10 83 FOOT $48.00 $3,984.00 9 PARKING LOT GRADING AND SUBGRADE PREPARATION (North Area)32 05 10 5,417 SQ. FT.$1.50 $8,125.50 10 UNTREATED BASE COURSE (PARKING LOT PAVEMENT) (North Area)32 11 23 134 CU. YD.$65.00 $8,710.00 11 RESTORE CONCRETE PAVEMENT (7 INCH THICK) (PARKING LOT) (North Area)32 13 13 5,471 SQ. FT.$14.50 $79,329.50 12 RESTORE PARKING LOT PAVEMENT MARKINGS (North Area)32 17 23 1 LUMP $500.00 $500.00 13 CONCRETE STORM DRAIN INLET BOX 33 41 00 1 EACH $1,500.00 $1,500.00 14 8 INCH C900 PVC STORM DRAIN PIPE 33 41 00 24 FOOT $75.00 $1,800.00 $132,276.70 NO.ITEM APWA SPEC.QUANTITY UNIT UNIT PRICE AMOUNT 15 MOBILIZATION, TRAFFIC CONTROL, PERMITTING, SURVEY (South Split)DIVISION 1 1 LUMP $12,500.00 $12,500.00 16 REMOVE CANOPY AND SUPPORTS TO BELOW SUBGRADE (South Area)02 41 13 1 LUMP $15,000.00 $15,000.00 17 REMOVE CONCRETE PAVEMENT (South Area)02 41 14 3,391 SQ. FT.$2.50 $8,477.50 18 30" CONCRETE CURB AND GUTTER (All)32 16 13 325 FOOT $36.00 $11,700.00 19 CONCRETE SIDEWALK (All)32 16 13 590 SQ. FT.$10.50 $6,195.00 20 CONCRETE DRIVEWAY, FLARED - 7 INCH THICK (All)32 16 13 188 SQ. FT.$36.00 $6,768.00 21 LANDSCAPE ROCK (All)31 05 13 21 CU YD $150.00 $3,142.59 22 PARKING LOT GRADING AND SUBGRADE PREPARATION (South Area)32 05 10 3,391 SQ. FT.$1.50 $5,086.50 23 UNTREATED BASE COURSE (PARKING LOT PAVEMENT) (South Area)32 11 23 84 CU. YD.$65.00 $5,460.00 24 RESTORE CONCRETE PAVEMENT (7 INCH THICK) (PARKING LOT) (South Area)32 12 05 3,391 SQ. FT.$14.50 $49,169.50 25 RESTORE PARKING LOT PAVEMENT MARKINGS (South Area)32 17 23 1 LUMP $500.00 $500.00 26 IRRIGATION (All)32 84 23 1,697 SQ FT $0.65 $1,103.05 27 TURF GRASS (All)32 92 00 40 SQ YD $65.00 $2,600.00 28 DECIDUOUS SHRUB (All)32 93 43 15 EACH $85.00 $1,275.00 29 DECIDUOUS TREE (All)32 93 43 5 EACH $400.00 $2,000.00 30 UNDERGROUND DRAINAGE DETENTION STRUCTURE (R-TANK SD or Equal) (All)33 41 00 828 CU FT $15.00 $12,420.00 31 12 INCH C900 PVC STORM DRAIN PIPE 33 41 00 43 FOOT $100.00 $4,300.00 32 CATCH BASIN WITH PRETREATMENT HOOD 33 41 00 1 EACH $8,000.00 $8,000.00 33 CLEANOUT BOX 33 41 00 1 EACH $4,000.00 $4,000.00 $155,697.14 $287,973.84 PST FUND ELIGIBLE COSTS SUBTOTAL PST FUND NON-ELIGIBLE COSTS SUBTOTAL TOTAL COSTS SCHEDULE 2 - PST FUND NON-ELIGIBLE COSTS