Loading...
HomeMy WebLinkAboutDAQ-2025-000837.rAf COMPASS MINERALS \-/ Compass Minerals 755 N 10500 W Ogden, UT 84404 www.compassminerals.com T (801) 731-3100 January 23,2025 Mr. Bryce Bird Utah Division of Air Quality 195 North 1950 West Salt Lake City, Utah 84174 i',i\/i5|oN oF AIR (lllnLlTY RE:40 CFR 63 Subpart DDDDD Compliance Certification (Operating Permit No. 5700001004) Mr. Bird, ln accordance with Operating Permit provision ll.B.20.e and Utah Administrative Code (UAC) R307-415-5c(5), the following compliance certification is submitted for Compass Minerals Ogden lnc. (Compass Minerals). This compliance certification covers the period from 07/03/2019 to 7213U2O24 and includes identification of each term or condition of the permit that is the basis for this certification, the compliance status of each identified term or condition, and the methods used to determine compliance status. On July 26rh,2024 Zeeco performed a tune up on Boilers #1 and #2 per the requirements listed in 40 CFR 63.7540(a)(10)(i)through (vi). A detailed description of the requirements, as well as the work performed by Zeeco is listed below. Per 40 CFR 63.7540 (aX10)(i): Zeeco inspected the burners and cleaned and replaced as needed components ofthe burners. Per 40 CFR 53.7540 (aX10Xii): Zeeco inspected the flame pattern and adjusted the burner as necessary to optimize the flame pattern consistent with manufacturer's specifications. Per 40 CFR 63.7540 (aX1OXiii): Zeeco inspected the system controlling the air-to-fuel ratio and ensured that they were calibrated and functioning properly. Per 40 CFR 63.7540 (aX10Xiv): Zeeco optimized the total emissions of CO and NOx consistent with the manufacturer's specifications. Per 40 CFR 63.7540 (aX10Xv): Zeeco measured concentrations in the effluent stream, please see attached report. Per 40 CFR 53.7540 (aX10)(vi): Compass maintains these reports on-site. Please contact lan Wright (wrishti@compassminerals.com, (801) 732-3011) if you have any questions regarding the information provided. REVIEWED Initials JBR Date 1/12/2025 Comp Status Meets File # 10917 Blue 2 both boilers tune up .zAr COMPASS MINERALS \-/ Respectfully, Compass Mlnerals 765 N 10500 W Ogden, UT 84404 T (801) 731-3100 Ken Potts Plant Manager Compass Minerals Ogden lnc. Cc: EPA Region 8 . Boiler Burners . Duct Burners . Burner Monogement Systems 80 Spring Lane Plainville, CT 06062 USA Phone: 918-893-8598 Fax: 918-251-5519 CUSTOMER: Compass Minerals PO#: ZEECO S.O.: DATE: 7126124 PROJECT NAME: Compass Minerals PERSONNEL CONTACTED: Aaron Ried SERVICE TECHNICIAN: Scott Flatt ATTACHMENTS: N/A , , ', . l',1 ;6 ii 1'171 ' 1 -1 1: i', ,' ::'rr.'NlAi- O' IAL ITY-l I i 1. Safety checks were performed by site personnel on boilers 1 and 2. 2. Site installed new Pitot tubes for the Air flow in Boiler #1. 3. Zeroed and checked air flow transmitter on boiler ff1 and set upper range value. 4. Tuned Boiler # 1 combustion. Tuned airflow to match Gas flow for the best efficiency, Nox was under 9 ppm throughout the firing range. 5. 6. 7. Site installed new Pitot tubes for the Air flow in Boiler #2. Zeroed and checked air flow transmitter on boiler #2 and set upper range value. Tuned Boiler # 2 combustion. Tuned airflow to match Gas flow for the best efficiency, Nox was under 9 ppm throughout the firing range.