Loading...
HomeMy WebLinkAboutDERR-2025-001139718 E. Bridger Lane, Elk Ridge, Utah 84651(801)361-2930 Fax (815)572-9616 rockwellutah@yahoo.com Rockwell Solutions, Inc. 718 E Bridger Lane Elk Ridge, UT 84651 (801) 361-2930 February 12, 2025 Mr. Kevin Beery Department of Environmental Quality Division of Environmental Response and Remediation PO Box 144840 Salt Lake City, Utah 84114-4840 Re: Well Abandonment Jenkins Oil Santa Clara Facility ID: 6000046 2753 W Santa Clara Drive Release ID: IVB Santa Clara, Utah Dear Mr. Beery: Rockwell Solutions completed well abandonment activities at the above-referenced site in December 2024 and February 2025. The following monitoring wells were abandoned: MW-1 MW-18 MW-31 MW-33 MW-5 MW-19 MW-32 MW-35 MW-7 MW-20 MW-26R MW-36 MW-9 MW-21 MW-28 MW-37 MW-15 MW-27 MW-31 MW-17 MW-28 MW-32 The following remediation wells were abandoned: MW-2 MW-30 AS-6 MW-3 AS-1 AS-7 MW-6 AS-2 AS-8 MW-23 AS-3 AS-9 MW-26 AS-4 AS-10 MW-29 AS-5 SVE-1 SVE-6 SVE-2 SVE-7 SVE-3 SVE-8 SVE-4 SVE-9 SVE-5 SVE-10 718 E. Bridger Lane, Elk Ridge, Utah 84651(801)361-2930 Fax (815)572-9616 rockwellutah@yahoo.com Also, vapor well VW-1 was abandoned. All wells were plugged/abandoned in accordance with current environmental industry standards and Utah Division of Water Rights requirements. Each well was abandoned by Rockwell Solutions personnel. At all monitoring well locations, the well can was removed, the well was filled with bentonite chips and cut off below grade, and the surface was backfilled and patched to match the surrounding pavement or material. Monitoring wells MW-8, MW-24, MW-25, and MW-34 and vapor wells VW-2, VW-3, VW-4, and VW-5 could not be located and are assumed to have been destroyed. Figures 1, 2, and 3 show the locations of all of the site monitoring wells, remediation wells, and vapor wells. All monitoring wells and remediation wells for the site have been properly abandoned. If you need additional information or have any questions, please contact me at (801) 361-2930. Thank you, David S. Hansen Certified UST Consultant CC#130 cc: Andrea Johnson, Jenkins Oil A T L S N A C A R A D RIV E Figure 1 Jenkins Oil 2753 W Santa Clara Drive Santa Clara, UtahNORTH Approx. scale in feet 00 180 V E Y A R D R V E IN D I JENKINS OIL Groundwater Monitoring Well MW-31 MW-25 MW-5 MW-15 MW-7 MW-27 MW-9 MW-36 MW-19 Monitoring Well Network MW-35 MW-17 MW-26 MW-11 MW-28 MW-24 MW-1 MW-33 MW-37 MW-20 6-9 - MW-32 MW-34 MW-21 MW-8 MW-18 MW-6 MW-29 MW-30 SVE-1 l v Santa C ara Dri e AS/SVE System Layout Jenkins Oil 2753 W. Santa Clara Dr. Santa Clara, Utah NORTH Approx. scale in feet 00 30 Point of Release MW-26 Groundwater Monitoring Well Product Piping to Dispensers MW-12 Destroyed Monitoring Well SVE-2 SVE-3 SVE-4 SVE-5 AS-1 AS-2 AS-3 AS-4 AS-5 MW-2 MW-23 2008 Excavation 2008 Excavation SVE-6 MW-12 Soil Vapor Extraction Well Air Sparge Well 2010 Excavation Figure 2 Clover Patch Building Jenkins Oil Office SVE System Piping AS System Piping MW-26 MW-3 Catox SVE-7 SVE-9SVE-8 SVE-10 AS-6 AS-8 AS-7 AS-10 AS-9 MW-14 MW-13 2010 Excavation Site Map Showing Vapor Wells Jenkins Oil 2753 W. Santa Clara Dr. Santa Clara, Utah NORTH Approx. scale in feet 00 30 Figure 3 Map is from 2010 Access Environmental report