HomeMy WebLinkAboutDERR-2025-000949Tank # / Tank Facility ID / Product Leak Detection: UST Monthly Compliance Inspection Facility Information Name:Fast Stop 1109 Certification/Inspection #:56710 Address:6030 W 20800 N State ID:0100133 Phone Number:Form Completed By:Larry Vasquez Date:11/20/2024 T2 DSL 1 T2 DSL 1 Diesel T3 DSL 2 T3 DSL 2 Diesel T5 DYE DSL T5 DYE DSL Dyed Diesel T6 ETH FREE T6 ETH FREE Ethanol Free Unleaded T4 PUL T4 PUL Premium Tanks: 1 Is release detection equip. operating w/o alarms or unusual conditions? Y N NA Y N NA Y N NA Y N NA Y N NA 2 Is tank free of water? Y N NA Y N NA Y N NA Y N NA Y N NA 3 Primary Tank Release Detection Method Inspected:Interstitial Monitoring Interstitial Monitoring Interstitial Monitoring Interstitial Monitoring Interstitial Monitoring 4 Date of last passing result:11/20/2024 11/20/2024 11/20/2024 11/20/2024 11/20/2024 5 Are Inventories reconciled daily and are the variances within the guideline set by the facility owner? Y N NA Y N NA Y N NA Y N NA Y N NA Lines: 6 Are line leak detectors present? Y N NA Y N NA Y N NA Y N NA Y N NA 7 LD s operating properly (no slow flow)? Y N NA Y N NA Y N NA Y N NA Y N NA 8 Primary Line Release Detection Method Inspected Sump Sensor Monitoring Sump Sensor Monitoring Sump Sensor Monitoring Sump Sensor Monitoring Sump Sensor Monitoring 9 Date of last passing result:11/20/2024 11/20/2024 11/20/2024 11/20/2024 11/20/2024 Fill/Overfill: 10 Fill caps, adapters, gaskets in good condition? Y N NA Y N NA Y N NA Y N NA Y N NA 11 Fills properly marked? Y N NA Y N NA Y N NA Y N NA Y N NA 12 Spill bucket free of liquid/debris? Y N NA Y N NA Y N NA Y N NA Y N NA 13 Spill bucket free of damage/drain work correctly? Y N NA Y N NA Y N NA Y N NA Y N NA 14 Does the spill bucket drain assembly work correctly? Y N NA Y N NA Y N NA Y N NA Y N NA 15 For double wall spill bucket, is the interstitial monitoring equipment functioning, in good condition and not in alarm? Y N NA Y N NA Y N NA Y N NA Y N NA 16 Fill cap in place and sealed tightily? Y N NA Y N NA Y N NA Y N NA Y N NA 17 Overfill drop tube free of obstructions? Y N NA Y N NA Y N NA Y N NA Y N NA Vapor: 18 Vapor cap in place and sealed tightly? Y N NA Y N NA Y N NA Y N NA Y N NA 19 Vapor recovery adapter intact? Y N NA Y N NA Y N NA Y N NA Y N NA 20 Vapor recovery lids painted orange? Y N NA Y N NA Y N NA Y N NA Y N NA 21 Is Vapor Bucket free of damage and free of liquid/debris? Y N NA Y N NA Y N NA Y N NA Y N NA STP Secondary Containment: 22 Sump containment free of water/fuel/debris? Y N NA Y N NA Y N NA Y N NA Y N NA 23 STP and piping free of leaks and seeps? Y N NA Y N NA Y N NA Y N NA Y N NA 24 Sump containment free of damage? Y N NA Y N NA Y N NA Y N NA Y N NA 25 For DW containment with Brine, are levels correct? Y N NA Y N NA Y N NA Y N NA Y N NA 12/9/24, 2:26 PM Monthly Inspection UST CO about:blank 1/2 Tank # / Tank Facility ID / ProductLeak Detection: 13 26 Sensors located @ lowest point in containment? Y N NA Y N NA Y N NA Y N NA Y N NA T1 RUL T1 RUL Unleaded Tanks: 1 Is release detection equip. operating w/o alarms or unusual conditions? Y N NA 2 Is tank free of water? Y N NA 3 Primary Tank Release Detection Method Inspected:Interstitial Monitoring 4 Date of last passing result:11/20/2024 5 Are Inventories reconciled daily and are the variances within the guideline set by the facility owner? Y N NA Lines: 6 Are line leak detectors present? Y N NA 7 LD s operating properly (no slow flow)? Y N NA 8 Primary Line Release Detection Method Inspected Sump Sensor Monitoring 9 Date of last passing result:11/20/2024 Fill/Overfill: 10 Fill caps, adapters, gaskets in good condition? Y N NA 11 Fills properly marked? Y N NA 12 Spill bucket free of liquid/debris? Y N NA 13 Spill bucket free of damage/drain work correctly? Y N NA 14 Does the spill bucket drain assembly work correctly? Y N NA 15 For double wall spill bucket, is the interstitial monitoring equipment functioning, in good condition and not in alarm? Y N NA 16 Fill cap in place and sealed tightily? Y N NA 17 Overfill drop tube free of obstructions? Y N NA Vapor: 18 Vapor cap in place and sealed tightly? Y N NA 19 Vapor recovery adapter intact? Y N NA 20 Vapor recovery lids painted orange? Y N NA 21 Is Vapor Bucket free of damage and free of liquid/debris? Y N NA STP Secondary Containment: 22 Sump containment free of water/fuel/debris? Y N NA 23 STP and piping free of leaks and seeps? Y N NA 24 Sump containment free of damage? Y N NA 25 For DW containment with Brine, are levels correct? Y N NA 26 Sensors located @ lowest point in containment? Y N NA Dispensing Equipment:Qty:Facility Notes: 27 UDC free of water/fuel/debris? Y N NA 28 All meters/ piping free from leaks and seeps? Y N NA 29 UDC in good condition & free from damage? Y N NA 30 For DW containment with Brine, are levels correct? Y N NA 31 Sensors located lowest point in UDC? Y N NA 32 Shear valves properly set and secured? Y N NA 33 Nozzles, swivels, hoses and connectors free of leaks? Y N NA 34 All product and whip hoses in good condition? Y N NA Cathodic Protection: 35 Rectifier is on? Y N NA Contractor Signature:Date:11/20/2024 Printed Name:Larry Vasquez Certification Number: 12/9/24, 2:26 PM Monthly Inspection UST CO about:blank 2/2 If any answers in Questions 3,4,5,6,7,11,13 or 14 are No, the system has failed the test. Overfill Alarm Inspection Facility Information Name:Fast Stop 1109 Certification/Inspection #:56712 Address:6030 W 20800 N, Plymouth, UT, 84330 State ID:0100133 Phone Number:Form Completed By:Larry Vasquez Date:11/20/2024 Overfill Alarm Information This procedure is to determine wheather the high level alarm is operational and will trigger when the tank is no more than 90% full. See PEI/RP1200 Section 7.3 for inspection procedure. This procedure is applicable to tank level monitor stems that touch the bottom of the tank when in place. Tank #T1 RUL T2 DSL 1 T3 DSL 2 T4 PUL T5 DYE DSL Tank Facility ID T1 RUL T2 DSL 1 T3 DSL 2 T4 PUL T5 DYE DSL Product Stored Unleaded Diesel Diesel Premium Dyed Diesel Tank Level Brand Veeder Root Veeder Root Veeder Root Veeder Root Veeder Root Tank Level Model TLS-350 TLS-350 TLS-350 TLS-350 TLS-350 1. Tank Diameter, in 117.500 91.500 91.500 91.500 91.500 2. Actual Tank Capacity, gal 19761 14543 14543 11593 7795 3.Overfill alarm activates in the test mode at the console? Y Y Y Y Y 4.When activated, overfill alarm can be heard or seen while delivering to the tank? Y Y Y Y Y 5.After removing the probe, it has been inspected and any damage or missing parts replaced? Y Y Y Y Y 6. Float moves freely on stem without binding?Y Y Y Y Y 7. Moving product level float up stem triggers alarm?Y Y Y Y Y 8.Inch level from bottom of stem when 90% alarm is triggered 105.75 82.35 82.35 82.35 82.35 9. Calculated tank volume from Question 8 17780 13080 13085 10428 7011 10. Tank % full 89.98 89.94 89.97 89.95 89.94 11. Is Question 10 less than 90%Y Y Y Y Y 12.Fuel float level on the console agrees with the gauge stick reading? Y Y Y Y Y 13. Overfill activates at 90% or less of tank capacity?Y Y Y Y Y 14.Fuel float level on the console agrees with the gauge stick reading Y Y Y Y Y Test Results Pass Pass Pass Pass Pass Tank #T6 ETH FREE Tank Facility ID T6 ETH FREE 12/9/24, 2:26 PM Overfill Alarm Inspection about:blank 1/2 If any answers in Questions 3,4,5,6,7,11,13 or 14 are No, the system has failed the test. Product Stored Ethanol Free Unleaded Tank Level Brand Veeder Root Tank Level Model TLS-350 1. Tank Diameter, in 91.500 2. Actual Tank Capacity, gal 7795 3.Overfill alarm activates in the test mode at the console? Y 4.When activated, overfill alarm can be heard or seen while delivering to the tank? Y 5.After removing the probe, it has been inspected and any damage or missing parts replaced? Y 6. Float moves freely on stem without binding?Y 7. Moving product level float up stem triggers alarm?Y 8.Inch level from bottom of stem when 90% alarm is triggered 82.35 9. Calculated tank volume from Question 8 7005 10. Tank % full 89.87 11. Is Question 10 less than 90%Y 12.Fuel float level on the console agrees with the gauge stick reading? Y 13. Overfill activates at 90% or less of tank capacity?Y 14.Fuel float level on the console agrees with the gauge stick reading Y Test Results Pass Comments Operator Certification Contractor Printed Name:Larry Vasquez Contractor Signature: 12/9/24, 2:26 PM Overfill Alarm Inspection about:blank 2/2 UST Overfill Equipment Inspection Facility Information Name:Fast Stop 1109 Certification/Inspection #:56711 Address:6030 W 20800 N, Plymouth, UT, 84330, Plymouth, UT, 84330 State ID:0100133 Phone Number:Form Completed By:Larry Vasquez Date:11/20/2024 Tank Information 1.Tank #T1 RUL T2 DSL 1 T3 DSL 2 T4 PUL T5 DYE DSL 2.Tank Facility ID T1 RUL T2 DSL 1 T3 DSL 2 T4 PUL T5 DYE DSL 3.Product Unleaded Diesel Diesel Premium Dyed Diesel 4.Nominal Capacity, gallons 19761 14543 14543 11593 7795 5.Actual Capacity, gallons 19761 14543 14543 11593 7795 6.Req. Shutoff %95 95 95 95 95 7.Calculated Shutoff Vol., gallons 18772.95 13815.85 13815.85 11013.35 7405.25 8.Calculated Shut-off Level, inches 106 82.37 82.37 83.37 82.12 9.Drop Tube Length, inches 35.75 50 50.5 52 58 10.Top of Droptube to Shutoff Level, inches 49.25 59 62 57.5 60.5 11.Tank Dia/depth, inches 117.5 91.5 91.5 91.5 91.5 12.Riser Length, inches 9 9.5 10 4 5 13.Measured Shut-off Level, inches 77.25 42 39.5 38 36 14.Overfill Prevention Device Brand OPW OPW OPW OPW OPW 15.Overfill Type Drop Tube Flapper valve Drop Tube Flapper valve Drop Tube Flapper valve Drop Tube Flapper valve Drop Tube Flapper valve Automatic Shutoff Device Inspection 16.Drop tube removed from tank?Yes Yes Yes Yes Yes 17.Drop tube and float mechanisms are free of debris? Yes Yes Yes Yes Yes 18.Float moves freely without binding and poppet moves into flow path? Yes Yes Yes Yes Yes 19.Bypass valve in the drop tube is open and free of blockage (if present)? Yes Yes Yes Yes Yes 20.Flapper is adjusted to shut off flow at required shutoff capacity? Yes Yes Yes Yes Yes Ball Float Valve Inspection 21.Tank top fittings are vapor-tight and leak-free? NA NA NA NA NA 22.Ball float cage free of debris?NA NA NA NA NA 23.Ball is free of holes and cracks and moves freely in cage? NA NA NA NA NA 12/9/24, 2:26 PM UST OverFill about:blank 1/2 24.Vent hole in pipe is open and near top of tank? NA NA NA NA NA 25.Ball float pipe is proper length to restrict flow at required shutoff capacity? NA NA NA NA NA 26.Test Result Pass Pass Pass Pass Pass 1.Tank #T6 ETH FREE 2.Tank Facility ID T6 ETH FREE 3.Product Ethanol Free Unleaded 4.Nominal Capacity, gallons 7795 5.Actual Capacity, gallons 7795 6.Req. Shutoff %95 7.Calculated Shutoff Vol., gallons 7405.25 8.Calculated Shut-off Level, inches 82.12 9.Drop Tube Length, inches 55.5 10.Top of Droptube to Shutoff Level, inches 63.75 11.Tank Dia/depth, inches 91.5 12.Riser Length, inches 6 13.Measured Shut-off Level, inches 33.75 14.Overfill Prevention Device Brand OPW 15.Overfill Type Drop Tube Flapper valve Automatic Shutoff Device Inspection 16.Drop tube removed from tank?Yes 17.Drop tube and float mechanisms are free of debris?Yes 18.Float moves freely without binding and poppet moves into flow path?Yes 19.Bypass valve in the drop tube is open and free of blockage (if present)?Yes 20.Flapper is adjusted to shut off flow at required shutoff capacity?Yes Ball Float Valve Inspection 21.Tank top fittings are vapor-tight and leak-free?NA 22.Ball float cage free of debris?NA 23.Ball is free of holes and cracks and moves freely in cage?NA 24.Vent hole in pipe is open and near top of tank?NA 25.Ball float pipe is proper length to restrict flow at required shutoff capacity?NA 26.Test Result Pass Manufacture's suggested procedures were used. Comments Operator Certification Contractor Printed Name:Larry Vasquez Contractor Signature: Certification Number: 12/9/24, 2:26 PM UST OverFill about:blank 2/2 UST Operator Inspection -Utah YEAR ;J_tJJ?-/ Facility Name fr)L..../-, ')fr)f'.. !/()CJ Faclllty ID O lot:,/ J 3 Address Id) is Iv I ~0~(}0 Ni ?I lJM'l~ I Primary Class B Operator NAME(S) AND INITIALS OF PERSON(S) CONDUCTING MO~HLY INSf>ECTIONS: ~ 5tMMS ~> Please respond to ALL of the following questions with a Y (Yes), N (No), or NA (Not Applicable) answer. Months of the Current Year J F M A M J J A s 0 N D Monthly Inspection -Release Detection 1 Release detection equipment is operating with no alarms or other unusual ✓ ✓ ✓ / / / ✓ ✓ --Y y operating conditions. ✓ I 2 Records of release detection (tanks and piping) are reviewed and current. .., v ,/ / / / ./ ,/ / rY y Monthly Inspection -Spill Prevention Equipment 3 Equipment is undamaged, intact and free from defects. V ✓ ./ / / ,,.... / V / V 4 Equipment is free from debris, water, or product. V ' ✓ ✓ / / ,, / / / , \ s Fill Pipe is unobstructed. V ✓ / / ✓ ,,, / Iv / '~ \ 6 Fill cap is un-broken and is securely on the fill piP.e . V ✓,,,..., / / ,.. / ....-../'-I~ 7 Double walled spill prevention equipment -Interstitial area is free from leaks. ✓ / V / / /' / ✓ ~ ' y Initials of person performing Inspection. ~· ~ ~ X-. I.JV ,tit! f-5:) ~ (If, ~V l.11 .. Annual Inspection -Containment Sumps Date of annual Inspection 8 Secondary Containment Sumps Visual Inspection of sump indicates no damage and it is free from debris, water and fuel. (STP, Dispenser and Transition) The penetration fittings for conduits and piping entering the STP Sumps are intact. 9 Double Walled Sumps Interstitial area is free from leaks. 10 Hand-held release detection Hand-held release detection equipment (bailer, gauge stick, etc.) is serviceable and equipment operable. I certify under penalty of law that I am the Class B Operator referenced above and that I am familiar with information on this form and that it is true, accurate and was completed in accordance with R311-203-7. Signature of the Primary Class B Operator (Sign this document after the last inspection of the Current Year) Date B Operator# Comments/Follow up: Turn over for record of lnlcr~tlllal Monitoring v!Nual ln~11ccllons 1111d l11111rcss cd C urrent rcctllll•r checks.