HomeMy WebLinkAboutDDW-2025-001176West Haven Capacity Calculation.xlsx Page 1 of 2/3/2025 Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* System Name West Haven Special Service District System Number Utah 29120 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -373 Number of other connections - - - 2 ERCs of other connections 2.0 (Example: water use of 2 factories equals to water use of 55 homes.) Total Equivalent Residential Connections (ERCs)375.0 MIN. REQUIREMENTS FOR INDOOR WATER USE Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 208.3)400 (150,000) 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >180 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >48%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.10 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >2.00 2 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Irrigation zone 1 3 4 5 MIN. REQUIREMENTS FOR IRRIGATION USE 6 Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 325 45.2 178 35,640 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,455 Maximum fire suppression duration (in hours) for water system or pressure zone 1 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >87,300 (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) 2. Summary of Water System Capacity Requirements MINIMUM REQUIREMENTS FOR WATER SYSTEM Source (indoor + outdoor)Storage (indoor + outdoor + fire) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 1,125 253.5 578 272,940 2.1 Does this system have adequate source capacity (per R309-510-7)? This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Required Source Capacity 253.5 gpm Existing Source Capacity 3,200.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 1262.2% 2.2 Does this system have adequate storage capacity (per R309-510-8)? This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Total Required Storage 272,940 gal Existing Storage Capacity 1,000,000 gal Storage Capacity Deficit None gal Required Fire Storage 87,300 gal Is storage deficiency solely due to fire storage?Not Applicable Existing % of Total Req'd 366.4% West Haven Capacity Calculation.xlsx Page 2 of 2/3/2025 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) MINIMUM REQUIREMENTS FOR INDOOR USE Source Storage Facility Type GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs Modern Recreation Camp 60 0 30 0 0.00 0 0.0 Semi-Developed Camp w/ flush toilets 20 0 10 0 0.00 0 0.0 Semi-Developed Camp w/o flush toilets 5 0 2.5 0 0.00 0 0.0 RV Park N/A 100 N/A 50 0.13 0 0.0 Number of people per camp site 0 Source (GPD/vehicle) Storage (Gal. /vehicle) ERC/1000 vehicles served Vehicles served/day ERCs Roadway Rest Stop w/ flushometer valves 7 3.5 8.8 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) West Haven Special Service District Total Existing Source Capacity (in gpm)3,200 4.1 Projected ERCs Calculation (optional)WS001 Roy 29016 10"2000 Total Projected ERCs 447 WS001 Roy 29016 6"1200 Existing Residential Connections 400 Obligated Future ERCs (enter below)47 47 Future residential units Maximum ERCs (assuming indoor use only)5760 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)1,000,000 WS001 Roy PWS#29016 1,000,000 WS001 Roy City consective connection with garanteed 1,000,000 storage.