Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2025-000935
IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 2/1/2025 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 1/31/2025 Order Number: 2377226 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-Eleven 36340 715 S Main St State ID 1000774 Pleasant Grove, UT 84062 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2377226 Date: 1/31/2025 Site Name/ID: 7-Eleven 36340 / 36340 Address: 715 S Main St State ID 1000774 City: Pleasant Grove State: UT Zip: 84062 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 TNK1 Regular RUL Pressure 50 09:47 10:47 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 TNK2 Premium PUL Pressure 50 09:47 10:47 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 TNK3 Diesel Low Sulfur Diesel Pressure 50 09:47 10:47 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-Eleven 36340 715 S Main St State ID 1000774 Pleasant Grove UT 84062 36340 Tanknology, Inc. 7-ELEVEN, INC. P.O. BOX 711 DALLAS TX 75221 972-828-7575 01/31/2025 RUL PUL Veeder Root FX1V Vaporless LD- 2000 Vaporless LD- 2000 30 15 150 2 10 3 30 30 200 2 20 3 32 32 110 2 20 3 UT151 David Mathie NW1-2377226 Low Sulfur Diesel TTNK1 Regular:1 TTNK2 Premium:1 TTNK3 Diesel:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2377226 Date:1/31/2025 Site Name/ID:7-Eleven 36340 Address:715 S Main St State ID 1000774 City:Pleasant Grove State:UT Zip:84062 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 40 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2025 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-Eleven 36340 7-ELEVEN, INC. 715 S Main St State ID 1000774 Pleasant Grove UT 84062 1000774 Tanknology, Inc. P.O. BOX 711 DALLAS TX 75221 972-828-7575 800-964-1250 01/31/2025 1 2 3 RUL PUL DSL VR350 VR350 VR350 11527 11627 7829 92 92 92 77 77 76.5 1.5 1.5 1.5 UT151 David Mathie 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-Eleven 36340 Name :TANKNOLOGY INC. Address :715 S Main St State ID 1000774 Pleasant Grove, UT 84062 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-785-0378 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :10 Products per Nozzle :3 Tanks Manifolded ?Yes Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK1 Regular RUL 11527 8568 2959 TNK2 Premium PUL 11627 6205 5422 10:38 2.00 2.00 2.00 1.99 1.99 1.98 1.89 Pass Total 23154 14773 8381 All 10:38 2.00 2.00 2.00 1.99 1.99 1.98 1.89 Pass Comments: Tester :David Mathie Test Date :1/31/2025 Signature :Work Order :2377226 WO: 2377226 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 20 0.0424 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.26 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -4.05 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 4.16 Pass Neg Leak Rate (CFH)0.21 17 0.0360 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.99 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 20 0.0424 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.23 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -4.09 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 4.05 Pass Neg Leak Rate (CFH)0.21 15 0.0318 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.92 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0233 Total -ve LR: 0.0678 Test Date 1/31/2025 Technician Name David Mathie WO #2377226 Facility Name / Loc #7-Eleven 36340 36340 Street 715 S Main St State ID 1000774 City, St, Zip Pleasant Grove, UT 84062 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2377226 Site ID / Name:36340 / 7-Eleven 36340 Address:715 S Main St State ID 1000774 City:Pleasant Grove State:UT Zip:84062