Loading...
HomeMy WebLinkAboutDERR-2025-000728 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRP-017-25 January 21, 2025 Sara Gallien Walmart, Inc. 2101 Southeast Simple Savings Drive Bentonville, Arkansas 72716 Re: Notice of Approval to Remove Delivery Prohibition Tag Walmart Supercenter #5237, located at 1632 North 2000 West, Clinton, Utah Facility Identification No. 3000571 Dear Ms. Gallien: The Division of Environmental Response and Remediation (DERR) has received all the documentation necessary to re-issue the attached certificate of compliance for the 20,000-gallon gasoline, 12,000-gallon gasoline, 8,000-gallon gasoline, and 10,000-gallon diesel tanks at this facility. This notice satisfies the requirement for written authorization to remove the delivery prohibition tags in accordance with Utah Admin. Code R311-206-8(f). Please remove and discard any tags that were attached to the fill due to revocation of the certificate of compliance. If you have additional questions or concerns, please contact the DERR project manager identified on the red tags, at (801) 536-4100. Sincerely, Brent H. Everett, Director Division of Environmental Response and Remediation BHE/GH/tt Enclosure: Certificate of Compliance cc: Brian E. Hatch, Director, Davis County Health Department Jay Clark, Environmental Health Director, Davis County Health Department UST Red Tag Removal Letter – CoC Issuance Sign-Off Sheet ERRU#____________ Author Subject File Name on Google Drive Enclosures Attached CoC Attached Tank Data Sheet(internal use only – do not mail) Payment of Fees Confirmed? Priority CC’s Special Instructions Draft Approval Process Project Manager Section Manager Final Approval Process Section Secretary Author Branch Secretary Administrative Secretary Section Secretary Scan # Certified Mail Enclosures Included CC’s Mailed Mailed By GH GH CoC Tank Data Sheet Rush 01/21/2025 Yes Red Tag Removal Yes 3000571 Gary Harris  01/21/2025 01/21/2025 TT :: 017-25 01/21/2025 GH GH 01/21/2025 SS 01/21/2025 01/21/2025 2025 UST CERTIFICATE OF COMPLIANCE ISSUED TO:LOCATION OF TANKS: SARA GALLIEN Walmart Supercenter # 5234 WALMART INC.1632 N 2000 W 2101 SE SIMPLE SAVINGS DR CLINTON UT 84015 BENTONVILLE, AR 72716 Facility ID: 3000571 Tank #Capacity Substance Desc Compliance Financial Assurance Mechanism 1 20000 Gasoline Yes PST Fund 2A 12000 Gasoline Yes PST Fund 2B 8000 Gasoline Yes PST Fund 3 10000 Diesel Yes PST Fund This certificate will automatically lapse if any of the required fees are not paid. It may also be revoked for failure to comply with state and federal UST regulations. Possession of this certificate does not signify coverage under the Utah PST Fund. Cleanup requirements may be obtained from the Division of Environmental Response and Remediation. UTAH DEPARTMENT OF ENVIRONMENTAL QUALITY Underground Storage Tank Inspection Verification Form Facility ID:3000571 Owner Name:WALMART INC.Facility Name:Walmart Supercenter # 5234 Owner Address:2101 SE SIMPLE SAVINGS DR Street Address:1632 N 2000 W BENTONVILLE, AR 72716 CLINTON, UT 84015 Operator A:MOISES DE JESUS DIAZ CARABALLO / (801) 779- 3165 / 12/31/2027 Operator B:MOISES DE JESUS DIAZ CARABALLO / (801) 779 -3165 / 12/31/2027 Owner Email:Sara.Gallien@walmart.com UTM Coordinates X/Y:410896 / 4554562 Disp ID/Alt ID Substance UDC Pipe Flex Loc Install Date UDC Install Date Fire Valve Sat Present UDC Test Disp Flex CP Test 1 - 1/2 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/7/2025 2 - 3/4 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 3 - 5/6 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 4 - 7/8 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 5 - 9/10 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 6 - 11/12 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 7 - 13/14 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 8 - 15/16 Gas/Diesel Yes Steel Flex in Sump 01/14/2025 01/14/2025 Yes No 1/9/2025 Tank ID/Alt ID:1 / 1 EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / No PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / Yes Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:12/10/2024 / 20000 / LLD Model:Veeder Root PLLD Substance Stored:Gasoline / Regular Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:Yes / ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / Interstitial DW / ALD ATG Specs: / / Liquid Status STP Sump Test:01/09/2025 Spill Bk Test: ATG Test:1/16/2025 PVV Test:Overfill Test:1/16/2025 LTT Test:LLD Test:01/16/2025 CP Tank Test:CP Pipe Test: Tank ID/Alt ID:2 / 2A EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / Yes PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / Yes Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:12/10/2024 / 12000 / LLD Model:Veeder Root PLLD Substance Stored:Gasoline / Regular Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:Yes / ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / Interstitial DW / ALD ATG Specs: / / Liquid Status STP Sump Test:01/09/2025 Spill Bk Test: ATG Test:1/16/2025 PVV Test:Overfill Test:1/16/2025 LTT Test:LLD Test:01/16/2025 CP Tank Test:CP Pipe Test: Tank ID/Alt ID:3 / 2B EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled Siphon/Compart:No / Yes PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / Yes Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:12/10/2024 / 8000 / LLD Model:Veeder Root PLLD Substance Stored:Gasoline / Premium Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:Yes / ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / Interstitial DW / ALD ATG Specs: / / Liquid Status STP Sump Test:01/09/2025 Spill Bk Test: ATG Test:1/16/2025 PVV Test:Overfill Test:1/16/2025 LTT Test:LLD Test:01/16/2025 CP Tank Test:CP Pipe Test: Tank ID/Alt ID:4 / 3 EGen/AST/Stat e: No / No / No Pipe Material-Mod:Flexible Plastic - Double-Walled 1/21/2025 Page 1 of 2 Siphon/Compart:No / Yes PVV/StageI:Yes Pipe Type/STP Cont:Pressurized / Yes Tank Status:Currently In Use Two point STP Flex Connectors:Steel Flex in Sump Installed/Cap/Loc:12/10/2024 / 10000 / LLD Model:Veeder Root PLLD Substance Stored:Diesel / Diesel #1 Spill/Overfill/Sm deliv:5 gal. Double Walled Spill Bucket / Automatic shutoff / No Tank Material-Mod:Fiberglass Reinforced Plastic - Double-Walled PST Fund/Other Type:Yes / ATG:Veeder Root / TLS-450 Interstitial Monitor Tank/Pipe Rel Det:Interstitial DW / Interstitial DW / ALD ATG Specs: / / Liquid Status STP Sump Test:01/09/2025 Spill Bk Test: ATG Test:1/16/2025 PVV Test:Overfill Test:1/16/2025 LTT Test:LLD Test:01/16/2025 CP Tank Test:CP Pipe Test: 1/21/2025 Page 2 of 2