DAQ-2025-000522
1 DAQC-067-25 Site ID 10129 (B4) MEMORANDUM TO: STACK TEST FILE – WASATCH INTEGRATED WASTE MANAGEMENT DISTRICT – Landfill THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Paul Morris, Environmental Scientist DATE: January 21, 2025 SUBJECT: Location: 1997 East 3500 North, Layton, Davis County, UT Contact: Jesse Simonsen – 801-614-5624 Bryan Black – 801-301-8151 Tester: Alliance Technical Group, LLC Source: Landfill Gas Generator (LFG) FRS ID #: UT0000004901100033 Permit#: 1100033004, Date of Last Revision: September 18, 2024 Action Code: TR Subject: Review of Stack Test Report received January 14, 2025 On January 14, 2025, the DAQ received a stack test report for the Landfill Gas Generator (LFG) located at Wasatch Integrated Waste Management District’s Davis landfill located in Layton, UT. Testing was performed on December 16, 2024, to demonstrate compliance with the emission limits found in Permit Conditions II.B.3.c, II.B.3.d, and II.B.3.e. Source Test Date Pollutant DAQ Result Test Result Limit LFG 12/16/2024 NOx 0.4 g/hp-hr 0.3 g/hp-hr 0.5 g/hp-hr 1.65 lb/hr 1.4 lb/hr 2.46 lb/hr CO 2.2 g/hp-hr 2.2 g/hp-hr 2.5 g/hp-hr 9.88 lb/hr 9.9 lb/hr 12.31 lb/hr VOC 0.05 g/hp-hr 0.06 g/hp-hr 0.88 g/hp-hr 0.23 lb/hr 0.27 lb/hr 4.33 lb/hr DEVIATIONS: No deviations reported. CONCLUSION: The submitted test report appear to be acceptable. RECOMMENDATION: Emissions appear to have been in compliance with the applicable limits during the time of testing. HPV: No. ATTACHMENTS: Stack test report received January 14, 2025, and DAQ generated Excel test review spreadsheets. 6 3 NMOC 2024 Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name Wasatch Integrated Landfill Company Contact:Jesse Simonsen Contact Phone No.801-726-3658 Stack Designation:LFG Test & Review Dates Test Date:12/16/2024 & Review Date: 1/21/2025 Observer: Reviewer:Paul Morris Emission Limits Emission Rates NMHC NOX CO NMHC NOX CO g/HP-hr 0.8800 0.5000 2.5000 0.053 0.375 2.245 lbs./hr. 4.3 2.5 12.3 0.23 1.651 9.875 ppm Percent %O2 Correction as a whole #15.00 15.00 15.00 Test Information Heat Input Stack I.D. inches As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) 17.25 1.623 0.9910 1.716 0.84 25.27 1.3 Contractor Information Contact: Charles Horton Contracting Company: Alliance Technical Group, LLC Address: 3683 W 2270 S, Suite E West Valley City, UT 84120 Phone No.: (464) 352-7568 Project No.: Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Round Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2 Anthrocite 2 Bituminous 2 Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes NMOC 2024 Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification Wasatch Integrated Landfill LFG Average Emission Dry NMHC NOX CO g/HP-hr 0.053 0.375 2.245 EBW Average % concentration lbs./hr.0.23 1.65 9.87 1995 CO2 O2 ppm or % 8.98 61.38 603.44 10.62 8.34 Run 1 Enter O2 or CO2 Dry NMHC NOX CO CO2 O2 O2 Atomic Weight 44 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 1.002E-06 7.947E-06 4.394E-05 lbs./hr.0.23 1.81 9.99 10.61 8.24 ppm or %8.77 66.53 604.34 10.62 8.26 Run 2 Dry NMHC NOX CO CO2 O2 Atomic Weight 44 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 1.071E-06 7.348E-06 4.363E-05 lbs./hr.0.24 1.64 9.76 10.60 8.33 ppm or %9.37 61.51 600.01 10.62 8.31 Raw Value Run 3 Dry NMHC NOX CO CO2 O2 Atomic Weight 44 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 1.006E-06 6.703E-06 4.406E-05 lbs./hr.0.23 1.50 9.88 10.66 8.45 ppm or %8.80 56.11 605.957 10.55 8.46 Raw Value Run 4 Dry NMHC NOX CO CO2 O2 Atomic Weight 44 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm or %Raw Value Run 5 Dry NMHC NOX CO CO2 O2 Atomic Weight 44 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm or %Raw Value C For Cal Drift Raw Value C For Cal Drift C For Cal Drift C For Cal Drift C For Cal Drift O2 CO2 Clear lbs./MMBTU NMOC 2024 Calibration Error Test Test Date December 16, 2024 O2 CS - Cal. Span 23.88 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. RR03646 02/24/32 Mid-level 10.00 10.00 0.00 0.00% Passed Cal. CC731666 07/06/32 High-level 23.88 23.87 0.01 0.04% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 41.88% 100% of Cal. Span High-level 100.00% Test Date December 16, 2024 CO2 CS - Cal. Span 24.00 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. RR03646 02/24/32 Mid-level 10.30 10.30 0.00 0.000% Passed Cal. CC731666 07/06/32 High-level 24.00 24.00 0.00 0.000% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 42.92% 100% of Cal. Span High-level 100.00% Test Date December 16, 2024 NMHC CS - Cal. Span 45.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.18 0.18 0.400% Passed Cal. CC718971 04/09/32 Mid-level 23.00 23.31 0.31 0.689% Passed Cal. High-level 45.00 45.33 0.33 0.733% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 51.11% 100% of Cal. Span High-level 100.00% Test Date December 16, 2024 NOx CS - Cal. Span 100.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. EB0089838 08/09/29 Mid-level 50.00 50.11 0.11 0.110% Passed Cal. High-level 100.00 99.87 0.13 0.130% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.00% 100% of Cal. Span High-level 100.00% Test Date December 16, 2024 CO 12.31 CS - Cal. Span 850.00 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. CC729836 05/03/29 Mid-level 450.00 449.69 0.31 0.036% Passed Cal. High-level 850.00 852.78 2.78 0.327% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 52.94% 100% of Cal. Span High-level 100.00% Valid Cal Gas Valid Cal Gas Valid Cal Gas Valid Cal Gas Valid Cal Gas Valid Cal Gas Valid Cal Gas NMOC 2024 Division of Air Quality Stack Test Review ofWasatch Integrated Landfill NMHC NOX CO CO2 O2 LFG CS Calibration Span 45.00 100.00 850.00 24.00 23.88 Units ppm ppm ppm % % Unprotected CV - Cylinder Value: NMHC NOX CO CO2 O2Low-Level 0.00 0.00 0.00 0.00 0.00 Mid-Level 23.00 50.00 450.00 10.30 10.00 High-Level 45.00 100.00 850.00 24.00 23.88 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 51.1% 50.0% 52.9% 42.9% 41.9% 100% of Cal. Span 100.0% 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 23.00 50.00 450.00 10.30 10.00 Calibration Error Test Cs - Measured Concentration NMHC NOX CO CO2 O2 Low-Level 0.18 0.00 0.00 0.00 0.00 Mid-Level 23.31 50.11 449.69 10.30 10.00High-Level 45.33 99.87 852.78 24.00 23.87 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 23.31 50.11 449.69 10.30 10.00 Low-Level 0.40% 0.00% 0.00% 0.00% 0.00% ppmdv Difference 0.18 0 0 0 0 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.69% 0.11% 0.04% 0.00% 0.00% ppmdv Difference 0.31 0.11 0.31 0 0 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.73% 0.13% 0.33% 0.00% 0.04% ppmdv Difference 0.33 0.13 2.78 0 0.01 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values NMHC NOX CO CO2 O2 CO - Low-Level 0.18 0.00 0.00 0.00 0.01 System Bias. SBi - Zero Bias 0.00% 0.00% 0.00% 0.00% 0.04%± 5% of Span Difference 0 0 0 0 0.01 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 23.03 50.00 450.12 10.33 10.05 SBi - Up-Scale Bias 0.62% 0.11% 0.05% 0.12% 0.21% Difference 0.28 0.11 0.43 0.03 0.05 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:12/16/2024 SO2 NMHC NOX CO CO2 O2 NOX8.9 66.5 604.51 10.6 8.3 CO 19.8% 66.5% 71.1% 44.3% 34.6% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values NMHC NOX CO CO2 O2 CO - Low-Level 0.18 0.00 0.00 0.00 0.00 System Bias. SBi - Zero Bias 0.00% 0.00% 0.00% 0.00% 0.00%± 5% of Span Difference 0.0 0.0 0.0 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 23.00 50.00 450.13 10.30 10.00 SBi - Up-Scale Bias 0.69% 0.11% 0.05% 0.00% 0.00% Difference 0.3 0.1 0.4 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift 0.00% 0.00% 0.00% 0.00% 0.04% Drift Difference 0.0 0.0 0.0 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Pass Up-scale Gas Drift 0.07% 0.00% 0.00% 0.12% 0.21% Difference 0.0 0.0 0.0 0.0 0.1 Pass or Re-Calibrate Pass Pass Pass Pass Pass LFG Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 1.623 25.27 1.30 25.37 799 10.61 8.24 81.16 30.03 28.71 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 442.3940 0.9910 0.84 44.936 100.40 59 38.248 4.726 0.1100 0.9990 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat InputBtu/hr Low Mid High 1.3024 123.010 255,448 11,979 227,356.72 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2.00 1.414 796 61 52 831 749 81.421.90 1.378 798 63 52 737 735 2.7 3 1.90 1.378 798 63 53 640 638 1.5 4 2.00 1.414 799 63 53 942 927 14.8 5 1.80 1.342 800 64 54 6 1.50 1.225 801 64 54 7 1.20 1.095 801 64 55 8 1.40 1.183 799 65 55 9 1.90 1.378 800 65 55 10 1.90 1.378 800 65 56 11 2.00 1.414 801 65 56 12 1.80 1.342 801 66 56 13 1.60 1.265 801 66 57 14 1.40 1.183 799 15 1.50 1.225 799 16 1.50 1.225 798 17 18 1920 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog CO Calibration Gas Failed Bias Dialog NMOC 2024 Division of Air Quality Stack Test Review ofWasatch Integrated Landfill NMHC NOX CO CO2 O2 LFG CS Calibration Span 45.00 100.00 850.00 24.00 23.88 Units ppm ppm ppm % % CV - Cylinder Value: NMHC NOX CO CO2 O2Low-Level 0.00 0.00 0.00 0.00 0.00Mid-Level 23.00 50.00 450.00 10.30 10.00 High-Level 45.00 100.00 850.00 24.00 23.88 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 51.1% 50.0% 52.9% 42.9% 41.9%100% of Cal. Span 100.0% 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 23.00 50.00 450.00 10.30 10.00 Calibration Error Test Measured Concentration NMHC NOX CO CO2 O2Low-Level 0.18 0.00 0.00 0.00 0.00 Mid-Level 23.31 50.11 449.69 10.30 10.00 High-Level 45.33 99.87 852.78 24.00 23.87 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 23.31 50.11 449.69 10.30 10.00 Low-Level 0.40% 0.00% 0.00% 0.00% 0.00% ppmdv Difference 0.18 0 0 0 0 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.69% 0.11% 0.04% 0.00% 0.00% ppmdv Difference 0.31 0.11 0.31 0 0 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.73% 0.13% 0.33% 0.00% 0.04% ppmdv Difference 0.33 0.13 2.78 0 0.01 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values NMHC NOX CO CO2 O2 CO - Low-Level 0.18 0.00 0.00 0.00 0.00 System Bias. SBi - Zero Bias 0.00% 0.00% 0.00% 0.00% 0.00%± 5% of Span Difference 0 0 0 0 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 23.00 50.00 450.13 10.30 10.00 SBi - Up-Scale Bias 0.69% 0.11% 0.05% 0.00% 0.00% Difference 0.31 0.11 0.44 0 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:12/16/2024 SO2 NMHC NOX CO CO2 O2 NOX 9.5 61.5 600.04 10.6 8.3 CO 21.1% 61.5% 70.6% 44.0% 34.8% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values NMHC NOX CO CO2 O2 CO - Low-Level 0.18 0.00 0.00 0.00 0.00 System Bias. SBi - Zero Bias 0.00% 0.00% 0.00% 0.00% 0.00%± 5% of Span Difference 0.0 0.0 0.0 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 23.10 50.01 449.91 10.23 9.95 SBi - Up-Scale Bias 0.47% 0.10% 0.03% 0.29% 0.21% Difference 0.2 0.1 0.2 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift 0.00% 0.00% 0.00% 0.00% 0.00% Response Spec. Difference 0.0 0.0 0.0 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Pass Up-scale Gas Drift 0.22% 0.01% 0.03% 0.29% 0.21% Difference 0.1 0.0 0.2 0.1 0.1 Pass or Re-Calibrate Pass Pass Pass Pass Pass LFG Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 1.62 25.27 1.30 25.37 799 10.60 8.33 81.07 30.03 28.63 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 440.2787 0.9910 0.84 45.036 107.10 61 38.172 5.041 0.1167 0.9990 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 1.2884 121.81 253,145 11,862 223,613.26 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 1.90 1.378 796 63 55 854 770 83.9 2 1.90 1.378 798 63 56 749 745 4.1 3 2.00 1.414 798 64 56 643 641 2.241.80 1.342 798 64 56 944 928 16.9 5 1.60 1.265 797 64 57 6 1.30 1.140 796 65 57 7 1.20 1.095 796 65 58 8 1.60 1.265 797 65 58 9 1.80 1.342 798 65 58 10 1.90 1.378 800 66 59 11 1.90 1.378 800 66 59 12 1.80 1.342 801 66 60 13 1.60 1.265 801 66 60 14 1.40 1.183 800 15 1.50 1.225 800 16 1.50 1.225 800 17 1819 20 21 22 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog NMOC 2024 Division of Air Quality Stack Test Review ofWasatch Integrated Landfill NMHC NOX CO CO2 O2 LFG CS Calibration Span 45.00 100.00 850.00 24.00 23.88 Units ppm ppm ppm % % CV - Cylinder Value: NMHC NOX CO CO2 O2Low-Level 0.00 0.00 0.00 0.00 0.00Mid-Level 23.00 50.00 450.00 10.30 10.00 High-Level 45.00 100.00 850.00 24.00 23.88 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 51.1% 50.0% 52.9% 42.9% 41.9%100% of Cal. Span 100.0% 100.0% 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 23.00 50.00 450.00 10.30 10.00 Calibration Error Test Measured Concentration NMHC NOX CO CO2 O2Low-Level 0.18 0.00 0.00 0.00 0.00 Mid-Level 23.31 50.11 449.69 10.30 10.00 High-Level 45.33 99.87 852.78 24.00 23.87 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 23.31 50.11 449.69 10.30 10.00 Low-Level 0.40% 0.00% 0.00% 0.00% 0.00% ppmv Difference 0.18 0 0 0 0 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.69% 0.11% 0.04% 0.00% 0.00% ppmv Difference 0.31 0.11 0.31 0 0 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. High-Level 0.73% 0.13% 0.33% 0.00% 0.04% ppmv Difference 0.33 0.13 2.78 0 0.01 Status Passed Cal. Passed Cal. Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values NMHC NOX CO CO2 O2 CO - Low-Level 0.18 0.00 0.00 0.00 0.00 System Bias. SBi - Zero Bias 0.00% 0.00% 0.00% 0.00% 0.00%± 5% of Span Difference 0 0 0 0 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 23.10 50.01 449.91 10.23 9.95 SBi - Up-Scale Bias 0.47% 0.10% 0.03% 0.29% 0.21% Difference 0.21 0.1 0.22 0.07 0.05 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:12/16/2024 SO2 NMHC NOX CO CO2 O2 NOX 9.0 56.3 605.97 10.6 8.5 CO 19.9% 56.3% 71.3% 44.0% 35.4% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values NMHC NOX CO CO2 O2 CO - Low-Level 0.16 0.00 0.00 0.00 0.00 System Bias. SBi - Zero Bias 0.04% 0.00% 0.00% 0.00% 0.00%± 5% of Span Difference 0.0 0.0 0.0 0.0 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 23.12 50.29 450.11 10.16 10.07 SBi - Up-Scale Bias 0.42% 0.18% 0.05% 0.58% 0.29% Difference 0.2 0.2 0.4 0.1 0.1 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift 0.04% 0.00% 0.00% 0.00% 0.00% Response Spec. Difference 0.0 0.0 0.0 0.0 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Pass Pass Up-scale Gas Drift 0.04% 0.08% 0.02% 0.29% 0.08% Difference 0.0 0.3 0.2 0.1 0.1 Pass or Re-Calibrate Pass Pass Pass Pass Pass LFG Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms 1.62 25.27 1.30 25.37 800 10.66 8.45 80.89 30.04 28.60 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 443.1006 0.9910 0.84 45.050 109.60 63 38.079 5.159 0.1193 0.9990 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 1.2960 122.63 254,596 11,942 224,219.25 Enert > #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2.00 1.414 800 64 58 839 753 85.2 2 1.90 1.378 800 64 58 753 749 4.8 3 1.90 1.378 800 64 58 649 646 2.441.80 1.342 801 65 59 943 925 17.2 5 1.50 1.225 801 65 59 6 1.50 1.225 800 65 59 7 1.30 1.140 799 66 59 8 1.40 1.183 799 66 60 9 1.90 1.378 798 67 60 10 2.00 1.414 799 67 60 11 1.90 1.378 798 67 61 12 1.70 1.304 800 67 61 13 1.70 1.304 800 68 61 14 1.50 1.225 800 15 1.40 1.183 800 16 1.60 1.265 801 17 1819 20 21 22 23 24 Failed Bias Dialog Failed Cal Error Dialog Failed Drift Dialog Failed Bias Dialog