DAQC-050-25
Site ID 15663 (B1)
Jeffery Cowlishaw
Staker Parson Companies
2350 South 1900 West
Ogden, Utah 84401
Dear Mr. Cowlishaw:
Re: Staker Parson Companies – Temporary Relocation/Operation, Notice of Intent – Uintah
County
Your Notice of Intent dated January 15, 2025, to relocate portable aggregate equipment to the
temporary project for Staker Parson Companies’ Maeser East Facility, located 3.3 miles southwest
of Maeser, Utah, was received by the Utah Division of Air Quality (DAQ) and has been reviewed.
The following equipment has been approved for operation for this temporary project:
Keestract/R62 track crusher with 250 kW diesel engine
The State of Utah has permitted portable equipment for Staker Parson Companies on the Approval
Order (AO) DAQE-AN115180014-15 dated July 6, 2015. The above relocation address is a
permitted aggregate facility with established emission and production limits. All equipment
operating at this site must be in accordance with the current AO for this site
DAQE-AN156630002-20 dated January 10, 2020. The total production of aggregate from all
temporary projects when combined with the permanent equipment’s production cannot exceed the
12-month rolling limits as per Condition II.B.1.a.A of this AO.
Approval is granted to relocate and operate this equipment at the new location for a period not to
exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the
operation of equipment at this temporary site may be for up to 180 working days in any calendar
year not to exceed 365 consecutive days, starting from the initial relocation date.
+ 2 / 6 Ú à Û Ù Û Þ
DAQC-050-25
Page 2
The owner/operator shall maintain records of the actual operation hours, days, and production
rate, of the above referenced equipment at this relocation site and have the ability to submit the
information to the DAQ upon the request of representatives of the director. Please make certain
that the plant operator is aware of all the location specific requirements for this site and the
conditions of the aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9
observations be performed for all applicable portable crushers, screens, and attached conveyors.
Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after
April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep
maintenance records to ensure proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction
requirements for additional information.
This approval for relocation in no way releases the owner or operator from any liability for
compliance with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation
process please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SW:rh
Enclosure: Submitted Temporary Relocation Form
cc: TriCounty Health Department
4 * - - $ . — ) @ E v A ? A D @ D w ? B ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Wed, Jan 15, 2025 at 3:27 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Staker and Parson Companies has requested a Temporary Relocation. Please see the information below. Any
attachments can be access by clicking on the links.
Recipient Data:
Time Finished: 2025-01-15 15:27:27 MST
IP: 165.225.10.101
ResponseID: R_1NIjnSpumPNWZcN
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/vwQzQOfmzw3--
TKo7GUj9qXTelDL%2EIDq8dfmU7Z4fHAyNZdhU4cHptvkd7Sdr8aZ5%2EG7CWzmGnG74aTGye9jj-
JOkz2VLd9Hk2PJGWGm-mbXQgLxsrbC45DbZMkVlYLqfWLkxkVQa8kkSp-VcIehSlHm4ouchr%
2E1f6y8ljMzoREQ0KNCGjkdDOGP5ko3OCKHiQli8dxUCF5JjVAcdg3-SNt5mxoiGI%
2EVRQY6aZ2DeHXKJ48ikkzpi2YcXFcDCCDN2zmWVZzr-gBy13J1m1kp506bfDgs3ZbCphIENAI
MDTCa7o4ec37xl1204pY4feitWvRCyMGdCEAerjjN2hM8rg
Response Summary:
Please fill out the information below:
Contact Person: Jeffery Cowlishaw
Company Name: Staker and Parson Companies
Mailing Address: 2350 S 1900 W
City: Ogden
Zip: 84401
Phone Number: 385-405-4315
Email: jeffery.cowlishaw@stakerparson.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
No
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
BB254D3C71
Briefly give directions to the site and/or physical address:
5220 West Hwy 121 Maeser, UT. Approximately 5 miles west of Vernal on Hwy 121.
Proposed Relocation Information:
Closest City Maeser
County Uintah
UTM X Coordinates 4,477,643.115 N
UTM Y Coordinates 616,088.136 E
Approximate distance to the nearest house/business 1.5 miles
UTM X Coordinates to nearest house/business 4,479,259.106 N
UTM Y Coordinates to nearest house/business 617,895.918 E
Does this site currently have a permit with DAQ?
1/16/25, 10:31 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1821332281658313041%7Cmsg-f:1821355596170288918&s…1/2
Yes
If yes, what is the Permit (DAQ-AN) # ?
DAQE-AN156630001-16
If yes, what is the Permit Holder's Name?
Staker Parson Companies
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
SYNC Aggregate
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Track crusher
Make/Model Keestrack/R6e
Serial or ID# 54CR-129
Design Capacity 500TPH/250kW
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_2D7dwAlqTOwqlTU
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 16
Starting time of operation (am/pm) 6AM
Ending time of operation (am/pm) 10PM
Maximum hourly production rate for project 500TPH
Expected startup date 01/15/2025
Expected completion date 01/15/2026
What type of application is this for?
New Application
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1gvfAifJ0ymEc1I
1/16/25, 10:31 AM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1821332281658313041%7Cmsg-f:1821355596170288918&s…2/2