DAQC-012-25
Site ID 10303 (B1)
Kamren Garfield
Sunroc Corporation
730 North 1500 West
Orem, UT 84057
Dear Mr. Garfield:
Re: Sunroc Corporation – Temporary Relocation/Operation, Notice of Intent – Millard County
Your Notice of Intent dated January 2, 2025, to relocate portable aggregate equipment to the
temporary project for Ash Grove Cement’s Quarry, permitted by the Approval Order (AO)
DAQE-AN103030035-24, dated November 27, 2024, located off Highway 132, Leamington, UT, was
received by the Utah Division of Air Quality (DAQ) and has been reviewed.
The following equipment has been approved for operation for this temporary project:
KPI-JCI jaw crusher
Cedarapids crusher-screen plant
Caterpillar 708 hp generator
The State of Utah has permitted the above portable aggregate equipment for operation in the State of
Utah on Sunroc Corporation’s AO DAQE-AN125750006A-21, dated January 12, 2021. Approval is
granted to relocate and operate this equipment at the new location for a period not to exceed 180
operational days. Approval is subject to the conditions of the dust control plan submitted for this
location and the above portable AO. Hours of operation for this equipment shall be held to 16 hours
each day. The maximum production rate shall be held to the requested 600 tons per hour.
Emissions for this project have been estimated at the following:
Pollutant gram/sec lbs/hr lbs/24 hr tons/yr
PM10 2.31 18.35 183.45 14.31
SOx 0.92 7.32 73.24 5.71
NOx 6.11 48.49 484.88 37.82
CO 1.60 12.67 126.69 9.88
VOC 0.25 1.98 19.75 1.54
+ 2 / 6 Û Ý Û Ù Û Þ
DAQC-012-25
Page 2
Approval is granted to relocate and operate this equipment at the new location for a period not to
exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of
equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed
365 consecutive days, starting from the initial relocation date. The operational days per site cannot be
extended beyond the stipulated 365 consecutive day period.
The owner/operator shall maintain records of the actual operation hours, days, and production rate, of
the above referenced equipment at this relocation site and have the ability to submit the information to
the DAQ upon the request of representatives of the Director. Please make certain that the plant
operator is aware of all the location specific requirements for this site and the conditions of the
aforementioned AO.
Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations
be performed for all applicable portable crushers, screens, and attached conveyors. Subpart OOO also
mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which
are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure
proper spray bar operations.
Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary
project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for
additional information.
This approval for relocation in no way releases the owner or operator from any liability for compliance
with all other applicable federal, state, and local regulations including the UAC.
If you have any questions regarding this relocation authorization or the temporary relocation process
please contact Susan Weisenberg at (385) 306-6512.
Sincerely,
Jay P. Morris
Assistant Director
JPM:SPW:jl
Enclosure: Submitted Temporary Relocation Form
cc: Central Utah Public Health Department
cody.watkins@ashgrove.com Ash Grove Cement
4 * - - $ . — ) A B v A ? A D @ C w B G ˜
Susan Weisenberg <sweisenberg@utah.gov>
Portable/Temporary Relocation Form
1 message
noreply@qemailserver.com <noreply@qemailserver.com>Thu, Jan 2, 2025 at 4:22 PM
Reply-To: trigger@qemailserver.com
To: sweisenberg@utah.gov
Susan/Chad:
Site # -- Sunroc Corporation has requested a Temporary Relocation. Please see the information below. Any attachments
can be access by clicking on the links.
Recipient Data:
Time Finished: 2025-01-02 16:22:47 MST
IP: 67.177.56.121
ResponseID: R_5O9zM91Bg9XnAXi
Link to View Results: Click Here
URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/
ZOJFcsHADv7K7ElzUvcPrqQBLYpnNTBANri3NMkPBVq3bnWcBHWbaa9mSNxI06VDi97PPURPB89pOKSx6RLixGwD-
dqS2kOpqf-KujmpWYcafX6y5Znpw4gAGyPQcR7wTTiaizH11FWPAdFUFa38AvaWcnGF9YQ%
2ElOJ6QXlCVux3VojGM7k8PbFnrBVtiGQKFjDO2X8QBlfsjaEXfIwiax4OYeYHmXcs%2ESV-mUHhzCi0OYkJ%
2ErnI2NaigQ1U3zB26foRU0y47FXY-ZIwGGkBoaH3ifNvxEjhjt3RrJ79o2575QZyjeUewsxb4tPqn6ApIbAt31xEIuHGpIDc-
lGKZQ
Response Summary:
Please fill out the information below:
Contact Person: Kamren Garfield
Company Name: Sunroc Corporation
Mailing Address: 730 N 1500 W
City: Orem
Zip: 84057
Phone Number: 801-802-6933
Email: kgarfield@clydeinc.com
Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea...
No
All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo...
73b13d7b-545f-4a3e-b3db-fa0f0007aa43
Briefly give directions to the site and/or physical address:
Ash Grove Leamington Cement Plant Quarry
Proposed Relocation Information:
Closest City Leamington
County Juab
UTM X Coordinates 39.556196°
UTM Y Coordinates -112.186136°
Approximate distance to the nearest house/business 5.1 miles
UTM X Coordinates to nearest house/business 39.535991°
UTM Y Coordinates to nearest house/business -112.273057°
Does this site currently have a permit with DAQ?
1/6/25, 3:14 PM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1820181318564231482%7Cmsg-f:1820181318564231482&s…1/2
Yes
If yes, what is the Permit (DAQ-AN) # ?
DAQE-AN103030030-22
If yes, what is the Permit Holder's Name?
Ash Grove Cement Company
Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX)
DAQE-AN125750006A-21
Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine...
1
Equipment Type Jaw Crusher
Make/Model KPI-JCI CS3144
Serial or ID# 76-4049
Manufactured Date TBD
Design Capacity 600 tph
2
Equipment Type Crusher-Screen Plant
Make/Model Cedarapids 1316
Serial or ID# 76-4022
Manufactured Date TBD
Design Capacity 600 tph
3
Equipment Type Generator
Make/Model Caterpillar C15
Serial or ID# 62-4200
Manufactured Date TBD
Design Capacity 708 hp
Please attach a site diagram showing the equipment layout and general site dimensions for this re...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_23WxQgEPMYoWqtC
Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for...
No
Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re...
Total Hours of operation per 24 hr period 16
Starting time of operation (am/pm) 6 am
Ending time of operation (am/pm) 10 pm
Maximum hourly production rate for project 600 tph
Expected startup date 01/12/2025
Expected completion date 06/30/2025
What type of application is this for?
New Application
In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q...
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_ZlukBKtnb6RIAr7
Owner/Operator Representative:
https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_UyGtVZCZsD4RvVf
1/6/25, 3:14 PM State of Utah Mail - Portable/Temporary Relocation Form
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1820181318564231482%7Cmsg-f:1820181318564231482&s…2/2
Susan Weisenberg <sweisenberg@utah.gov>
Re: question regarding Ash Grove project
1 message
Kamren Garfield <kgarfield@clydeinc.com>Mon, Jan 13, 2025 at 6:36 PM
To: Susan Weisenberg <sweisenberg@utah.gov>
Cc: Chad Gilgen <cgilgen@utah.gov>
Hi Susan,
This is a different project. The processing equipment was moved out of there for over a year since the last project. When
Sunroc crushes for ash grove it's usually a pretty short duration (a couple of months). Hopefully this clears things up.
Thanks!
Kamren
Get Outlook for iOS
From: Susan Weisenberg <sweisenberg@utah.gov>
Sent: Monday, January 13, 2025 6:11:47 PM
To: Kamren Garfield <kgarfield@clydeinc.com>
Cc: Chad Gilgen <cgilgen@utah.gov>
Subject: ques on regarding Ash Grove project
Hello, I've been requested to check if the project submitted for Ash Grove Cement is a continuation of what was
authorized in 2023 (See C-327-23) or if it is a different project. Thanks, let me know if you have any questions.
Susan Weisenberg,
Environmental Scientist
Office: 385-306-6512
1/13/25, 6:49 PM State of Utah Mail - Re: question regarding Ash Grove project
https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r6498984732539562667%7Cmsg-f:1821186271487277446&…1/1
Susan Weisenberg <sweisenberg@utah.gov>
Re: Sunroc/Ash Grove TRP
1 message
Susan Weisenberg <sweisenberg@utah.gov>Tue, Jan 14, 2025 at 9:55 AM
To: Chad Gilgen <cgilgen@utah.gov>
Sorry, I already sent that one through yesterday. I'll see if I can still cancel it. Thanks
Susan Weisenberg,
Environmental Scientist
Office: 385-306-6512
On Tue, Jan 14, 2025 at 8:12 AM Chad Gilgen <cgilgen@utah.gov> wrote:
Hi Susan,
When you send this one back through eSign, please remove the sentence referencing the production of aggregate and
condition II.A.4 and, instead, reference the hours of operation and TPH submitted with Sunroc's TRP letter. You can
use the previous, 2023, TRP that was issued as a template for this one.
Thanks,
Chad
Chad Gilgen | Manager | Minor Source Compliance
385-306-6500 (cell)
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements.
On Mon, Jan 13, 2025 at 12:15 PM Chad Gilgen <cgilgen@utah.gov> wrote:
Hi Susan,
See attached for some comments and some supporting documentation for the comments.
Thanks,
Chad
Chad Gilgen | Manager | Minor Source Compliance
385-306-6500 (cell)
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements.
1/15/25, 11:28 AM State of Utah Mail - Re: Sunroc/Ash Grove TRP