HomeMy WebLinkAboutDDW-2025-000911DDW Reports <ddwreports@utah.gov>
Fwd: Significant Deficiencies Due Next Month #06015
2 messages
DDW IPS <ddwips@utah.gov>Mon, Jan 27
To: DDW Reports <ddwreports@utah.gov>
Please import into the site visit folder title 06015 Def Corr 1-2025
---------- Forwarded message ---------
From: Angie Jones <ajones@co.davis.ut.us>Date: Mon, Jan 6, 2025 at 3:33 PM
Subject: Re: Significant Deficiencies Due Next Month #06015To: Kraig Christensen <kchristensen@bountiful.gov>
Cc: DDW IPS <ddwips@utah.gov>
Jen,Hello! I hope your holiday season was wonderful and the new year is off to a good start.I know these are due today, nothing like getting things done at the last minute.Sorry for the delay.Please see attached information for Bountiful City (UTAH06015) IPS corrections.I have attached the correction notice, IPS report and supportive documents. I am also including an email correspondence for ST009 that should have been corrected in September of 2021.This is also on the correction notice. When I spoke with Kraig today he stated that Zesiger should be listed as inactive. That is not the case in Waterlink for the treatment plant but it is for the well. Do they have to request both be listed as inactive?Let me know if you have any questions or need further information.
Thanks!
Angela Jones
Environmental Health Bureau Manager
Davis County Health Department
Physical: 22 S State Street, Clearfield, UT 84015
Mailing: PO Box 618, Farmington, UT 84025
(o) 801-525-5120 | ajones@co.davis.ut.us
On Wed, Dec 11, 2024 at 12:26 PM Kraig Christensen <kchristensen@bountiful.gov> wrote:We have been working with Angie Jones at DCHD. We have sent pictures of all the repairs that have been made from our deficiencies to Angie. In the next week or so t
informa on she has gathered from our repairs will be coming your way.
Kraig Christensen / Water Director
Boun ful City Water
260 W. 1050 S.
Bountiful Utah, 84010
(801) 298-6180
From: Kraig Christensen <kchristensen@bountiful.gov>
Sent: Wednesday, December 11, 2024 12:12 PM
To: DDW IPS <ddwips@utah.gov>
Subject: Re: Significant Deficiencies Due Next Month #06015
Thanks for reaching out about our report. We have been working to make the correc ve ac ons to get the deficiencies.
Correc ve ac on taken per facility.
ST004 Stoneridge storage. Lid access hatch was replaced and operational with new gaskets.
ST007 Barton Creek storage. Replaced gaskets on both access hatch's.
ST009 Holbrook storage. Gaskets replaced on both access hatch's.
TP001 Zesiger Well. Inactive site. We removed the chlorine cylinders to use at other sites. Nothing to restrain at this point.
WS003 Calder Well #1. Well house & head not secured. We are having a cage built and powder coated that will be installed when it is finished.
WS018 100 East Well. This site is getting the same style cage built as Calder Well. Still have not got a delivery yet but will install when they are rea
I will send suppor ng pictures of the repairs we made in another email with the details. I might need to click the link to add more me to install the security cages on t
different loca ons. Kind of at the mercy of the cage delivery.
1/28/25, 7:16 AM State of Utah Mail - Fwd: Significant Deficiencies Due Next Month #06015
https://mail.google.com/mail/b/AEoRXRTEo9BVkyH_orvWHDvCX0am7TXJ52k6dGwWYeZV961SyVQ_/u/0/?ik=2401283fbe&view=pt&search=all&per…1/4
Kraig Christensen / Water Director
Boun ful City Water
260 W. 1050 S.
Bountiful Utah, 84010
(801) 298-6180
From: jyee@utah.gov <jyee@utah.gov> on behalf of DDW IPS <ddwips@utah.gov>
Sent: Wednesday, December 11, 2024 11:30 AM
To: Kraig Christensen <kchristensen@bountiful.gov>
Subject: Significant Deficiencies Due Next Month #06015
On August 14, 2024, a sanitary survey was conducted on Bountiful City Water System, revealing seven significant deficiencies. Our records indicate that six of thesdeficiencies are on active facilities and remain unresolved.
ST004 STONERIDGE STORAGE A 0 Hide Details ( 1 )
Code Description Severity Comments Determined
Date Pending
V009
STORAGE TANK LID
LACKS A FUNCTIONING
GASKET BETWEEN THE
LID AND FRAME
SIG Lid broken unable to see gasket.08/14/2024 25
ST007 BARTON CREEK STORAGE A 0 Hide Details ( 1 )
Code Description Severity Comments Determined
Date Pending
V009
STORAGE TANK LID
LACKS A FUNCTIONING
GASKET BETWEEN THE
LID AND FRAME
SIG Not properly gasketed.08/14/2024 25
ST009 HOLBROOK STORAGE A 15 Hide Details ( 2 )
Code Description Severity Comments Determined
Date Pending
V009
STORAGE TANK LID
LACKS A FUNCTIONING
GASKET BETWEEN THE
LID AND FRAME
SIG Not properly gasketed.08/14/2024 25
TP001 ZESIGER WELL CHLORINATOR + FLUORIDE A 0 Hide Details ( 2 )
Code Description Severity Comments Determined
Date Pending
TD15 CHLORINE CYLINDERS
NOT RESTRAINED SIG Cylinder not restrained.08/14/2024 25
WS003 CALDER WELL 1 A 0 Hide Details ( 1 )
1/28/25, 7:16 AM State of Utah Mail - Fwd: Significant Deficiencies Due Next Month #06015
https://mail.google.com/mail/b/AEoRXRTEo9BVkyH_orvWHDvCX0am7TXJ52k6dGwWYeZV961SyVQ_/u/0/?ik=2401283fbe&view=pt&search=all&per…2/4
Code Description Severity Comments Determined
Date Pending
S002
WELL HOUSE NOT
PROTECTED AGAINST
VANDALISM
SIG Wellhead not secured.08/14/2024 25
WS018 100 E WELL (REPLACE)A 0 Hide Details ( 1 )
Code Description Severity Comments Determined
Date Pending
S002
WELL HOUSE NOT
PROTECTED AGAINST
VANDALISM
SIG Wellhead not protected well.08/14/2024 25
If these issues have already been addressed, kindly provide detailed documentation outlining the corrective actions taken, along with any supporting photographic e
The system was granted 120 days to rectify these deficiencies, with the deadline set for January 6, 2025. If additional time is required to complete the necessary coplease follow this link to request a Corrective Action Plan.
Your prompt attention to this matter is greatly appreciated.
Thanks,Jen-
--
Jennifer Yee
IPS Rule Manager
Environmental Scientist | Division of Drinking Water
M: (385) 515-1501
drinkingwater.utah.gov
(801) 536-4200
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA
requirements.
CAUTION: This email originated from outside the organization. Do not click links or open attachments unless you recognize the sender and know the content is safe.
--
Jennifer Yee
IPS Rule Manager
Environmental Scientist | Division of Drinking Water
M: (385) 515-1501
drinkingwater.utah.gov
(801) 536-4200
Emails to and from this email address may be considered public records and thus subject to Utah GRAMA
requirements.
3 attachments
IPS Correction Notice UTAH06015_2024.pdf57K
IPS CORRECTIONS UTAH06015.pdf785K
Davis County Mail - Fw_ Bountiful City Sanitary Survey (06015).pdf404K
DDW IPS <ddwips@utah.gov>Mon, Jan 27, 2025 at 2:23 PM
To: DDW Reports <ddwreports@utah.gov>
1/28/25, 7:16 AM State of Utah Mail - Fwd: Significant Deficiencies Due Next Month #06015
https://mail.google.com/mail/b/AEoRXRTEo9BVkyH_orvWHDvCX0am7TXJ52k6dGwWYeZV961SyVQ_/u/0/?ik=2401283fbe&view=pt&search=all&per…3/4
Please import into the site visit folder title 06015 Def Corr 1-2025
Sorry, please replace this attachment from the the email I just sent.
---------- Forwarded message ---------
From: Angie Jones <ajones@co.davis.ut.us>Date: Mon, Jan 6, 2025 at 3:49 PM
Subject: Re: Significant Deficiencies Due Next Month #06015To: Kraig Christensen <kchristensen@bountiful.gov>
Cc: DDW IPS <ddwips@utah.gov>
Jen,One more item.Disregard the first IPS Corrections sheet.Somehow the two of the pictures for ST004 did not save. This one has two additional pictures of the replacement lid and gasket.
Thanks again!
Angela Jones
Environmental Health Bureau Manager
Davis County Health Department
Physical: 22 S State Street, Clearfield, UT 84015
Mailing: PO Box 618, Farmington, UT 84025
(o) 801-525-5120 | ajones@co.davis.ut.us
[Quoted text hidden]
[Quoted text hidden]
IPS CORRECTIONS.pdf
870K
1/28/25, 7:16 AM State of Utah Mail - Fwd: Significant Deficiencies Due Next Month #06015
https://mail.google.com/mail/b/AEoRXRTEo9BVkyH_orvWHDvCX0am7TXJ52k6dGwWYeZV961SyVQ_/u/0/?ik=2401283fbe&view=pt&search=all&per…4/4