HomeMy WebLinkAboutDSHW-2024-0094841
Division of Waste Management and
Radiation Control
Solid Waste Management Program
Mailing Address Office Location Phone (801) 536-0200
P.O. Box 144880 195 North 1950 West Fax (801) 536-0222
Salt Lake City, Utah 84114-488 Salt Lake City, Utah 84116 www.deq.utah.gov
APPLICATION FOR A TEMPORARY PERMIT TO OPERATE AN
EXPLORATION AND PRODUCTION WASTE FACILITY
In 2019, the Utah Legislature made changes to the Solid and Hazardous Waste Act, Utah Code § 19-6-
101 et seq., which required jurisdiction over the disposal of Oil and Gas Exploration and Production
Waste move from the Department of Natural Resources’ Division of Oil, Gas, and Mining (DOGM) to the
Department of Environmental Quality’s Division of Waste Management and Radiation Control (DWMRC).
In preparation for this regulatory shift, DWMRC has proposed a temporary permitting mechanism for
existing Exploration and Production (E&P) facilities as defined in the proposed Utah Admin. Code R315-
301-2(22)(a).
The proposed rules state that the Director of DWMRC may issue a temporary permit for the purposes of
facilitating the owner’s or operator’s good faith transition from regulation under Utah Admin. Code R649-9
to regulation under Utah Admin. Code R315-321 or R315-322. Applications for temporary permits must
be received by the Director of DWMRC no less than 30 days before October 1, 2024. The temporary
permits will expire one year from the effective date, which is the date the financial assurance mechanism
held by DOGM is transferred to DWMRC.
To complete a temporary permit application to operate an E&P facility, an owner or operator of an existing
E&P facility must:
1. Register the company in DWMRC’s Community Portal and complete facility information within the
Community Portal.
2. Complete the attached Exploration and Production Waste Facility Temporary Permit Application
Form.
3. Provide DWMRC with the following required documentation, to the extent it has not already been
provided to DWMRC or is not already in DWMRC’s possession:
a. Facility map with each landfarm cell, landfill cell, and surface impoundment labeled;
b. Copy of Division of Oil, Gas, and Mining Permit;
c. Copy of Division of Oil, Gas, and Mining Permit Approval/Issuance Letter; and
d. Copy of Division of Oil, Gas, and Mining Bonding (financial assurance).
4. Submit the Application Form and required documentation to DWMRC through the Community
Portal Miscellaneous Document Submission.
5. Within 120 days of DWMRC’s issuance of a temporary permit, the financial assurance
mechanism held by DOGM must be transferred to DWMRC. If the Director issues a temporary
permit, it shall not become effective until the financial assurance mechanism held by DOGM is
transferred to DWMRC. An effective temporary permit is required to operate an E&P Facility
under DWMRC’s jurisdiction.
2
Exploration and Production Waste Facility Temporary Permit Application Form
I. Facility Name and Location
Name of Facility
Recapture Brine Disposal Pond
Facility Address (Street or Directions to Facility)
5 Miles west of Montezuma Creek (Mile Post 5)
County
San Juan
City
Montezuma Creek
Zip Code
84534
Telephone
(435) 220-0609
Township
T40S
Range
R22E
Section
14
Quarter Section
Quarter/Quarter
Section
Main Gate Latitude: 37.30279 Longitude: -109.46703
II. Existing E&P Facilities
☐ Open Landfarm Cell(s)
☐ Evaporation Pond(s)
Number of Open Land farm Cells: 8
Number of Evaporation Ponds: 3
III. Facilities to be Permitted by DWMRC
☐ Landfill Cell(s)
☐ Surface Impoundment(s)
Number of Landfill Cells:
Number of Surface Impoundments:3
III. Facility Owner(s) Information
Legal Name of Facility Owner
Montezuma Well Service Inc.
Mailing Address
PO Box 540
City
Montezuma Creek
State
UT
Zip Code
84534
Telephone
(435) 651-3469
IV. Facility Operator(s) Information
Legal Name of Facility Operator
Montezuma Well Service Inc.
Mailing Address
PO Box 540
City
Montezuma Creek
State
UT
Zip Code
84534
Telephone
(435) 651-3469
V. Property Owner(s) Information
Is the property leased? Yes
Name of Property Owner
Trust Lands Administration
Mailing Address
102 Tower, 102 South 200 East #600
City
Salt Lake City
State
UT
Zip Code
84111
Telephone
(801) 538=5100
VI. Designated Contact Information
Facility Owner Designated Contact (if different than
above). Melvin Capitan Jr
Title
Consulting Manager
3
Mailing Address
PO Box 540
City
. Montezuma Creek
State
UT
Zip Code
84534
Telephone
(435) 220-0609
Email Address
mc47654@gmail.com
Alternative Telephone (cell phone or other)
Facility Operator Designated Contact (if different than
above)
(Same as Facility Owner VI.)
Title
Mailing Address
City
State
Zip Code
Telephone
Email Address
Alternative Telephone (cell phone or other)
Property Owner Contact (if different than above)
Jim Davis
Title
Lease Manager, Surface Resources
Mailing Address
102 Tower, 102 South 200 East #600
City
Salt Lake City
State
UT
Zip Code
84111
Telephone
(801) 538-5162
Email Address
jimdavis1@utah.gov
Alternative Telephone (cell phone or other)
(801) 440-1032
VII. Waste Types to be Disposed of (check all that
apply) VIII. Facility Area
☐ Exploration and Production wastes that are exempt from
hazardous waste rules (R315-260-4(b)(5)).
☐ Very Small Quantity Generator hazardous waste
Facility Area: 40 acres
Disposal Area: 9 acres
IX. Application Documents
Indicate documents attached to this application (all are required):
☐ Facility Map with each landfarm cell, landfill cell, and surface impoundment labeled
☐ Copy of Division of Oil, Gas, and Mining Permit
☐ Copy of Division of Oil, Gas, and Mining Approval/Issuance Letter
☐ Copy of Division of Oil, Gas, and Mining Bonding (Financial Assurance)
State of Utah
DEPARTMENT OF NATURAL RESOURCES
GARY R. HERBERT
Governor
SPENCER J. COX
Lieutenant Governor
MICHAEL R. STYLER
Executive Director
Division of Oil, Gas and Mining
JOHN R. BAZA
Division Director
Permit to Operate
********************
Facility Name:Recapture Brine Disposal
Facility Type: Commercial Waste Disposal Facility
Location: Section 14, Township 40S, Range 22E
County:San Juan
Approval Date:September 10, 2019
1. Issued to:
Montezuma Well Services Inc (81105)
2. Authority:
Pursuant to Utah Code Ann. §§ 40-6-1 et seq., and Utah Admin. Code §§ R649-9 et seq., the
Utah Division of Oil, Gas and Mining (“Division”) issues this Permit to operate an E and P waste
disposal facility.
3. Duration:
This Permit shall expire five years from the Approval Date (or at such time there is not an
approved variance). The Division may revoke, suspend, or impose additional operating
conditions or limitations on a disposal facility permit at any time, for good cause, after notice to
the operator. The Division may suspend a waste disposal permit or impose additional conditions
or limitations in an emergency to forestall an imminent threat to fresh water, public health, or
safety of the environment. Suspension of a disposal facility permit may be for a fixed period of
time or until the operator remedies the violation or potential violation. If the Division suspends a
disposal facility permit, the disposal facility shall not accept E and P waste during the suspension
period.
4. General:
4.1 Effect on Prior Permits. This Permit supersedes any existing E and P waste disposal permit
previously obtained for the Facility and provides the terms that govern operations at this
Facility.
4.2 Incorporation of Application.The Division issues this Permit in response to Montezuma’s
“Permit Renewal Application” dated 4/1/2018 and received by the Division on 7/1/2018,
(“Application”). The Facility shall operate in accordance with the best management practices
described in the Application.
4.3 Compliance with Applicable Laws. The Facility shall comply with Utah Code Ann. §§ 40-6-
1 et seq. and Utah Administrative Code §§ R649-9 et seq..
5. Reporting and Recordkeeping Requirements:
1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114-5801
telephone (801) 538-5340 x facsimile (801) 359-3940 x TTY (801) 538-7458 x www.ogm.utah.gov
The Facility shall comply with the reporting and recordkeeping requirements in Utah Admin.
Code § R649-9-11.
6. Modifications:
This Permit only applies to the Facility as it is described in the Application. Any additions to the
Facility or modifications of the waste treatment processes described in the Application are not
allowed and require a permit modification.
7. Enforcement:
The issuance of this permit does not supersede local ordinances, county planning and zoning
requirements, or other permits required to conduct business at the Facility. A copy of this
approval should be kept at the Recapture field office, and field personnel shall be aware of the
Conditions of Approval.
8. Approval:
Therefore, having met all the technical permit requirements of Utah Admin. Code §§ R649-9 et
seq., final approval to operate the Facility in accordance with this Permit is hereby granted.
9. Contact Information:
The following are Division of Oil, Gas and Mining contacts and their telephone numbers:
Dayne Doucet, Permit Manager: 801-538-5303
Bart Kettle, Operations Manager: 435-820-0862
Ammon McDonald, Environmental Scientist: 801-538-5337
Approved By:
________________________
By: Dayne Doucet
Title: Permit Manager
Dayne
Doucet
Digitally signed by Dayne Doucet
DN: cn=Dayne Doucet, o=DNR,
ou=DOGM,
email=daynedoucet@utah.gov,
c=US
Date: 2019.09.10 09:42:55 -06'00'
Conditions of Approval:
1. Evaporation Facilities
1.1 A minimum of 2 feet of freeboard shall be maintained in the pit(s) at all times, and that a
method of obviously displaying the freeboard shall be devised and implemented. Utah
Admin. Code § R649-9-4.6.4. Pit B can only accept waste water up to 50% of the depth of
the pit (4’).
1.2 Pit(s) are to be maintained such that hydrocarbons will not collect on the surface.
Hydrocarbon accumulations, other than de minimis quantities, shall be removed within 24
hours. Utah Admin. Code § R649-9-4.6.4.
1.3 Spraying water to accelerate evaporation should be closely monitored. Overspray outside the
lined pit area is considered a violation. Utah Admin. Code § R649-9-4.9.2.
1.4 The leak detection system must be checked weekly. Any leak must be reported to the
Division immediately, and corrective measures must be taken as directed by the Division.
1.5 The compacted secondary containment berms at the Facility shall be inspected quarterly and
after a major rainstorm or windstorm to ensure integrity Utah Admin. Code § R649-9-11.3.2.
1.6 Evaporation ponds are permitted to accept produced water.
1.7 Remove liner from Pit A and sample soils beneath liner within 24 months.
2. Landfarms
2.1 E and P waste accepted by the landfarm shall be sufficiently free of liquid content to pass a
60-mesh liquid paint filter test (i.e., no produced water or drilling mud).
2.2 Pooling of liquids in the landfarm is prohibited.
2.3 Within 72 hours after receipt of E and P waste, the operator shall prepare materials for
remediation.
2.4 Soils shall be turned regularly, a minimum of once a month.
2.5 Additional materials shall not be added until the soil concentrations of the current lift meet
the Division’s salinity and hydrocarbon cleanup standards.
2.6 Sample landfarms annually by July 1
st until materials meet DOGM abandonment levels.
2.7 Complete reclamation work for landfarm cells 1-6 within 12 months.
FAILURE TO COMPLY WITH THE ABOVE LISTED CONDITIONS OF
APPROVAL MAY RESULT IN CLOSURE OF THE FACILITY.
STATE OF UTAH Waste Disposal Permit
DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT
DIVISION OF OIL, GAS AND MINING Original Filing Date: 9/3/2019
WASTE DISPOSAL PERMIT
1. Name of Operator
Montezuma Well Services Inc
2. Utah Account Number
101465.0
3. Address of Operator City State Zip
PO Box 540 Montezuma Creek UT 84534
4. Phone Number
435-651-3469
5. Name of 3rd Party Contractor
Envirotech
6. Facility Name
Recapture Brine Disposal
7. Address of Contractor City State Zip
5796 US Highway 64 Farmington NM 87401
7. Phone Number
5056320615
9. Additional Comments
September 10, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Operator: Montezuma Well Services Date: 5/14/2018
Facility: Recapture Brine
Number of Acres to be Reclaimed Estimated 36 Acres
Contamination Remediation Cost Estimates $1,972,025.00
Removal of Infrastructure Costs Estimates $110,650.00
Earthwork and Grading Cost Estimates $163,990.00
Revegetation Cost Estimates $327,980.00
Post Closure Cost Estimates $186,292.00
Total Cost Estimate $2,760,937.00
(Increase above total cost estimate by 26.8% if indirect costs are not included) $739,931.12
Total Reclamation Cost Required $3,500,868.12
Bond Posted $0.00
Difference Between Cost Estimate and Bond -$3,500,868.12
Contamination Remediation Cost Estimate-This price includes
mobe/Demobe of equipment, transportation and disposal of estimated
35,000 cubic yards of salt to White Mesa Landfill facility in Blanding,
Utah if it meets criteria. This also includes labor, equipment to remove
the remaining sludge from pits, and liners with disposal included.
Removal of Infrastructure Costs Estimate - This price includes
mobe/demobe, labor to clean out, load, transport and dispose or
recycle any surface equipment (Tanks, Vessels, piping, etc.) Also labor
and equipment to dig up visible contamination beneath surface
equipment and apply to landfarm cells.
Earthwork and Grading Cost Estimate-This price includes
mobe/demobe equipment to disc-plow the landfarm cells every quarter
for two years until they meet regulatory guidelines. If there are any cells
that don't meet standards after two years, trucking and disposal of up
to 3000 cubic yards of soil to remove from site.
Five Year E&P Waste Disposal Facility Bond Calculation Summary Form
Direct and Indirect Costs
If you have questions about this form please contact Bev Wiser at 801-538-5346 or email
btwiser@utah.gov.
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
Revegetation Cost Estimate - This price includes mobe/demobe of
equipment, labor to re-seed all native vegetation.
Post Closure Cost Estimate - This price includes mobe/demobe of
equipment, labor to remove all fencing, and remaining equipment and
or debris and labor to conduct closure sampling and reporting.
Sundry Number: 98887 File: Detailed Site Description
RECEIVED: Sep. 03, 2019
&ŽƌŝǀŝƐŝŽŶhƐĞKŶůLJ
Compliance Review Completed:
No outstanding compliance
Active violation/compliance matter
Signature:
Comments
&ŝǀĞzĞĂƌΘWtĂƐƚĞDisposal Facility Wermit Renewal Checkůisƚ
WĞƌŵŝƚZĞŶĞǁĂůƉƉůŝĐĂƚŝŽŶ^ƵďŵŝƐƐŝŽŶ
^ƵďŵŝƚĂŶĂƐƐĞƐƐŵĞŶƚŽĨƐŝƚĞƌĞĐůĂŵĂƚŝŽŶƌĞƋƵŝƌĞŵĞŶƚƐĨƌŽŵĂĐĞƌƚŝĨŝĞĚ
ƚŚŝƌĚƉĂƌƚLJĐŽŶƚƌĂĐƚŽƌZϲϰϵͲϵͲϴ͘Ϯ
^ƵďŵŝƚĐůŽƐƵƌĞĐŽƐƚĞƐƚŝŵĂƚĞƐĨƌŽŵĂĐĞƌƚŝĨŝĞĚƚŚŝƌĚƉĂƌƚLJĐŽŶƚƌĂĐƚŽƌ
ZϲϰϵͲϵͲϴ͘Ϯ
WƌŽǀŝĚĞďŽŶĚĂŵŽƵŶƚĂƉƉƌŽǀĞĚďLJƚŚĞŝǀŝƐŝŽŶZϲϰϵͲϵͲϴ
ĞƚĂŝůĞĚ^ŝƚĞĞƐĐƌŝƉƚŝŽŶ
&ƵŶĐƚŝŽŶŽĨƚŚĞǁĂƐƚĞĚŝƐƉŽƐĂůĨĂĐŝůŝƚLJ
ƵƌƌĞŶƚĨĂĐŝůŝƚLJŵĂƉ
^ŝƚĞĚĞƐĐƌŝƉƚŝŽŶƐĂŶŶŽƚĂƚĞĚǁŝƚŚĨĂĐŝůŝƚLJŝŶĨƌĂƐƚƌƵĐƚƵƌĞĂŶĚĂƐƐŽĐŝĂƚĞĚĨƵŶĐƚŝŽŶ
ŽŶƚĂŵŝŶĂƚŝŽŶƐƐĞƐƐŵĞŶƚ
ĞƐĐƌŝƉƚŝŽŶŽĨĞdžŝƐƚŝŶŐĐŽŶƚĂŵŝŶĂƚŝŽŶǁŝƚŚƐĂŵƉůĞƌĞƐƵůƚƐ
WƌŽƉŽƐĞĚŵŽŶŝƚŽƌŝŶŐͬƌĞŵĞĚŝĂƚŝŽŶ
WƌŽƉŽƐĞĚƉƌĂĐƚŝĐĞƐƚŽƉƌĞǀĞŶƚĨƵƌƚŚĞƌĐŽŶƚĂŵŝŶĂƚŝŽŶ
ƋƵŝƉŵĞŶƚƐƐĞƐƐŵĞŶƚ
ĞƐĐƌŝƉƚŝŽŶĂŶĚĂƐƐĞƐƐŵĞŶƚŽĨĞƋƵŝƉŵĞŶƚůŽĐĂƚĞĚĂƚƚŚĞĨĂĐŝůŝƚLJ
ĞƐĐƌŝďĞŝŶĚĞƚĂŝůƐĞƌǀŝĐĞůŝĨĞĨŽƌĞƋƵŝƉŵĞŶƚƵƐĞĚŝŶĨĂĐŝůŝƚLJŽƉĞƌĂƚŝŽŶƐĞƐĐƌŝƉƚŝŽŶŽĨƚĞƐƚŝŶŐ
ĐŽŵƉůĞƚĞĚĨŽƌĞƋƵŝƉŵĞŶƚ;ƚĂŶŬƐ͕ƉŝƉŝŶŐ͕ůŝŶĞƌƐ͕ůĞĂŬĚĞƚĞĐƚŝŽŶĞƋƵŝƉŵĞŶƚ͕ĞǀĂƉŽƌĂƚŝŽŶĨĂŶƐͿ
WƌĂĐƚŝĐĞƐƐƐĞƐƐŵĞŶƚ
ƐƐĞƐƐŵĞŶƚŽĨŵĂŶĂŐĞŵĞŶƚƉƌĂĐƚŝĐĞƐƵƚŝůŝnjĞĚƚŽŽƉĞƌĂƚĞƚŚĞĨĂĐŝůŝƚLJ/ĚĞŶƚŝĨLJĂůƚĞƌŶĂƚŝǀĞ
ƉƌĂĐƚŝĐĞƐǁŚŝĐŚĐŽƵůĚŝŵƉƌŽǀĞŽƉĞƌĂƚŝŽŶƐŽƌƌĞĚƵĐĞƉƌŽďĂďŝůŝƚLJŽĨĨƵƚƵƌĞĐŽŶƚĂŵŝŶĂƚŝŽŶ
Name of &ĂĐŝůŝƚLJOperator:
Name of &ĂĐŝůŝƚLJ͗
>ŽĐĂƚŝŽŶ͗
ĂƚĞ͗
WƌĞƉĂƌĞƌ͗
ĂƚĞ /ŶŝƚŝĂůƐ ĂƚĞ/ŶŝƚŝĂůƐ
ZĞĐĞŝǀĞĚ ZĞǀŝĞǁĞĚ
ZĞǀŝĞǁŽŵƉůĞƚĞĚ͗ƉƉůŝĐĂƚŝŽŶ^ƚĂƚƵƐ͗ WWZKs
&ŽƌŝǀŝƐŝŽŶhƐĞKŶůLJĞůŽǁdŚŝƐ>ŝŶĞ
Montezuma Well Services
Recapture Brine Disposal
T. 40 S., R 22 E., Sec 14 SWSE
05/14/18
Envirotech Inc
✔
Dayne Doucet Digitally signed by Dayne Doucet
DN: cn=Dayne Doucet, o=DNR, ou=DOGM,
email=daynedoucet@utah.gov, c=US
Date: 2019.09.03 15:28:16 -06'00'
07/01/18 BTK 08/19/19 DKD
07/01/18 BTK 08/19/19 DKD
08/19/19 DKD 09/03/19 BW $ 2,735,937
Cost Estimate Number are summed up for entire task and
not itemized out.
Variance approved to allow $1/bbl incremental bonding
payable monthly by 10th of month; minimum $1,000
monthly payment.
Dayne Doucet Digitally signed by Dayne Doucet
DN: cn=Dayne Doucet, o=DNR, ou=DOGM,
email=daynedoucet@utah.gov, c=US
Date: 2019.09.10 09:39:20 -06'00'✔
09/05/18 BTK Function of Facility not covered
Current Facility Map and site description included
09/05/18 BTK No Sample results for Salt in Pond C-BTK 9/5
Sample results provided for landfarm cells- BTK 9/5
09/03/19 DKD
04/03/19 BTK
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
/ŶĨƌĂƐƚƌƵĐƚƵƌĞZĞŵŽǀĂůŽƐƚƐ
Contouring or RegradingŽƐƚƐ
SeediŶŐŽƐƚƐ
Notes:
ŽŶƚĂŵŝŶĂƚŝŽŶŽƐƚƐ
ƐƚŝŵĂƚŝŶŐůŽƐƵƌĞŽƐƚĂŶĚŽŶĚŝŶŐǀĂůƵĂƚŝŽŶ
ZĞŵŽǀĂůͬZĞŵĞĚŝĂƚŝŽŶ
^ĂŵƉůŝŶŐ
WŽƐƚĐůŽƐƵƌĞŵŽŶŝƚŽƌŝŶŐ
džƉĞŶƐĞƐƚŽƌĞŵŽǀĞĂůůŝŶĨƌĂƐƚƌƵĐƚƵƌĞĂŶĚĞƋƵŝƉŵĞŶƚ
WƌŽũĞĐƚĞdžƉĞŶƐĞƚŽĐŽŶƚŽƵƌƐŝƚĞďĂĐŬƚŽŽƌŝŐŝŶĂůŐƌĂĚĞ
sŽůƵŵĞƐŽĨŵĂƚĞƌŝĂů
ƋƵŝƉŵĞŶƚĐŽƐƚƐ
>ĂďŽƌĐŽƐƚƐ
DĞƚŚŽĚŽĨƌĞƐĞĞĚŝŶŐ
^ƉĞĐŝĞƐƵƐĞĚĨŽƌƌĞǀĞŐĞƚĂƚŝŽŶ
ĂƚĞ/ŶŝƚŝĂůƐ
ZĞĐĞŝǀĞĚ
Comments
DŽŶŝƚŽƌŝŶŐWƌŽŐƌĂŵ
ĞƚĂŝůĞĚĚĞƐĐƌŝƉƚŝŽŶŽĨŵŽŶŝƚŽƌŝŶŐƉƌŽŐƌĂŵƐŝŶƵƐĞŽƌďĞŝŶŐƉƌŽƉŽƐĞĚ;ǀŝƐƵĂůŝŶƐƉĞĐƚŝŽŶƐŽĨ
ĞƋƵŝƉŵĞŶƚ͕ƉƌĞƐƐƵƌĞƚĞƐƚƐ͕ůĞĂŬĚĞƚĞĐƚŝŽŶƐLJƐƚĞŵƐ͕ǁĂƐƚĞĂĐĐŽƵŶƚĂďŝůŝƚLJ͕ĂƵƚŽŵĂƚĞĚƐLJƐƚĞŵƐ͕
ƉƌŽƉŽƐĞĚƉƌĂĐƚŝĐĞƐǁŚŝĐŚĐĂŶƌĞĚƵĐĞƚŚĞƌŝƐŬŽĨĨƵƚƵƌĞĐŽŶƚĂŵŝŶĂƚŝŽŶͿ
09/03/19 DKD
Conduct annual sampling for land farm cells.
Need to address Pit A and Pit C
09/03/19 BW
09/03/19 BW
09/03/19 BW
09/03/19 BW
Application missing- BTK 9/5:
Monitoring Practices-annual sampling land farms, sampling bottom of Pond A, Content analysis Pond C
Itemized Cost estimate from 3rd Party.
COA's Recommended:
-Variance granted for 12 month intervals. Incremental bonding $1/bbl. MWS work Land Farm cells. MWS coordinate with Division. MWS sample Land Farm Cells by July 1 annually.
MWS complete reclamation of #1-6. MWS remove liner materials from Pit A and sample soils. MWS sample Pit C contents and explore options for materials. Accept fluids into Pit B up
%50 depth
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
Sundry Number: 98887
RECEIVED: Sep. 03, 2019
GARY R. HERBERT
Governor
SPENCER J. COX
State of Utah
DEPARTMENT OF NATURAL RESOURCES
1594 West North Temple, Suite 1210,
PO Box 145801, Salt Lake City, UT 84114-5801
telephone (801) 538-5340 facsimile (801) 359-3940 TTY (801) 538-7458 www.ogm.utah.gov
Executive Director
Division of Oil, Gas and Minin
Date of Mailing:
Certified Mail No.:Melvin Capitan
Montezuma Well Services Inc
PO Box 540
Montezuma Creek, UT 84534
12/15/2020
7015 0640 0003 5303 6971
1/18/2021
Has not paid monthly incremental bonding amounts as required by approved variance request
dated 8/21/2019. $3,029 was due October 10th; $2,178 was due November 10th; and the
payment for November was due December 10th. However, the November report has not been
submitted so the amount of incremental bonding for November is currently unknown.
Has not submitted variance extension request.
NOTE: NOV sent via email on 12/15/2020 to mc47654@gmail.com
Rule R649-9. Waste Management and Disposal
Well or API #Date of Inspection
This notice shall remain in effect until it is modified, terminated, or vacated by a written notice of an authorized representative
of the director of the Division of Oil, Gas and Mining. Failure to comply with this notice will result in the Division pursuing
further actions against said operator. Further actions may include initiation of agency actions to order full cost bonding and
plugging and abandonment of wells and requests for bond forfeiture and civil penalties.
cc
Submit the E&P Waste Facility Report for November and December (by due date).
Pay the incremental bonding amounts for September, October, November, and December (by
due date).
Submit a request to extend the variance for another year.
1/18/2021
Oil and Gas Permitting Manager (801) 538-5303
Compliance FileCompliance File
Well / Facility File
Josh Payne, Compliance Mgr
Rachel Medina, Bonding Tech
Bart Kettle, Acting Deputy Director
Haley Sousa, Attorney General's Office
Recapture Brine Disposal 12/10/2020
Digitally signed by Dayne K
Doucet
Date: 2020.12.15 14:23:01
-07'00'
06/29/2020 verMontezuma Well Services Inc
8/4/2021 State of Utah Mail - Fwd: Montezuma Well Service, Recapture Disposal, E106069 Final Report
https://mail.google.com/mail/u/0?ik=ad25b7bcd0&view=pt&search=all&permthid=thread-f%3A1705205880302670978%7Cmsg-f%3A1705205880302…1/2
Jean Sweet <jsweet@utah.gov>
Fwd: Montezuma Well Service, Recapture Disposal, E106069
Final Report
1 message
Melvin Capitan <mc47654@gmail.com>Tue, Jul 13, 2021 at 3:17 PM
To: Jim Davis <jimdavis1@utah.gov>, Jean Sweet <jsweet@utah.gov>, Bart Kettle
<bartkettle@utah.gov>, Lisha Cordova <lishacordova@utah.gov>, Rachel Medina
<rachelmedina@utah.gov>, "Candelaria, Margie" <mcandelaria@utah.gov>,
travisgray@utah.gov, Dayne Doucet <daynedoucet@utah.gov>
Cc: Tamera Lansing <tbenally03804@gmail.com>, Melvin Capitan <mc47654@gmail.com>
All,
Per your request, June 2021 yearly soil sampling results on land farms at Recapture
Brine Disposal Ponds.
Melvin
---------- Forwarded message ---------
From: Raina Schwanz <rainaschwanz@envirotech-inc.com>
Date: Wed, Jul 7, 2021 at 2:39 PM
Subject: Montezuma Well Service, Recapture Disposal, E106069 Final Report
To: mc47654@gmail.com <mc47654@gmail.com>
Cc: Walter Hinchman <whinchman@envirotech-inc.com>, Alexa Michaels
<labadmin@envirotech-inc.com>, Lynn Jarboe <ljarboe@envirotech-inc.com>
Melvin,
Thank you for Choosing Envirotech Analytical Laboratory. Attached is the final report for
the “Recapture Disposal” project. Let us know if you have any questions. Envirotech
Laboratory values your feedback. Please take this new, updated survey to let us know
how we did!
Survey time is approximately 1 minute.
https://www.surveymonkey.com/r/F5J58TH
8/4/2021 State of Utah Mail - Fwd: Montezuma Well Service, Recapture Disposal, E106069 Final Report
https://mail.google.com/mail/u/0?ik=ad25b7bcd0&view=pt&search=all&permthid=thread-f%3A1705205880302670978%7Cmsg-f%3A1705205880302…2/2
Raina Schwanz
Envirotech Analytical Laboratory
Laboratory Administrator / Analyst
Office 505-632-1881
rainaschwanz@envirotech-inc.com
5796 U.S. Highway 64, Farmington NM 87401
CONFIDENTIALITY NOTICE: The contents of this email message and any attachments are intended solely for the addressee(s) and may contain
confidential and/or privileged information and may be legally protected from disclosure. If you are not the intended recipient of this message or their
agent, or if this message has been addressed to you in error, please immediately alert the sender by reply email and then delete this message and
any attachments. If you are not the intended recipient, you are hereby notified that any use, dissemination, copying, or storage of this message or its
attachments is strictly prohibited.
E106069 Envirotech3_v13 FINAL 07 07 21 1002.pdf
2391K
Analytical Report
Montezuma Well Service
6/28/2021
08103-0002
E106069
Recapture Disposal
envirotech
Practical Solutions for a Better Tomorrow
Project Name:
Work Order:
Job Number:
Received:
Report to:
Melvin Capitan
5796 U.S. Hwy 64
Farmington, NM 87401
Phone: (505) 632-1881
Envirotech-inc.com
Revision: 1
Report Reviewed By:
Walter Hinchman
Laboratory Director
7/7/21
Envirotech Inc. certifies the test results meet all requirements of TNI unless noted otherwise .
Statement of Data Authenticity: Envirotech Inc, attests the data reported has not been altered in any way.
Partial or incomplete reproduction of this report is prohibited, unless approved by Envirotech Inc.
Envirotech Inc, holds the Utah TNI certification NM00979 for data reported.
Envirotech Inc, holds the Texas TNI certification T104704557 for data reported.
[TOC_1] Title Page [TOC]
Page 1 of 25
Date Reported: 7/7/21
Melvin Capitan
PO Box 540
Montezuma, UT 84534
Project Name: Recapture Disposal
Workorder: E106069
Date Received: 6/28/2021 8:10:00AM
Melvin Capitan,
Thank you for choosing Envirotech, Inc. as your analytical testing laboratory for the sample(s) received on,
6/28/2021 8:10:00AM, under the Project Name: Recapture Disposal.
The analytical test results summarized in this report with the Project Name: Recapture Disposal apply to the
individual samples collected, identified and submitted bearing the project name on the enclosed
chain-of-custody. Subcontracted sample analyses not conducted by Envirotech, Inc., are attached in full as
issued by the subcontract laboratory.
Please review the Chain-of-Custody (COC) and Sample Receipt Checklist (SRC) for any issues reguarding
sample receipt temperature, containers, preservation etc. To best understand your test results, review the entire
report summarizing your sample data and the associated quality control batch data.
All reported data in this analytical report were analyzed according to the referenced method(s) and are in
compliance with the latest NELAC/TNI standards, unless otherwise noted. Samples or analytical quality control
parameters not meeting specific QC criteria are qualified with a data flag. Data flag definitions are located in the
Notes and Definitions section of this analytical report.
If you have any questions concerning this report, please feel free to contact Envirotech, Inc.
Respectfully,
Walter Hinchman Raina Schwanz Alexa Michaels
Laboratory Director Laboratory Administrator Sample Custody Officer
Office: 505-632-1881 Office: 505-632-1881 Office: 505-632-1881
Cell: 775-287-1762 rainaschwanz@envirotech-inc.com labadmin@envirotech-inc.com
whinchman@envirotech-inc.com
Field Offices:
Southern New Mexico Area West Texas Midland/Odessa Area
Lynn Jarboe Tom Brown
Technical Representative/Client Services Technical Representative
Office: 505-421-LABS(5227)Cell: 832-444-7704
Cell: 505-320-4759 tbrown@envirotech-inc.com
ljarboe@envirotech-inc.com
Envirotech Web Address: www.envirotech-inc.com
[TOC_1] Cover Page [TOC]
Page 2 of 25
Table of Contents
Title Page 1
Cover Page 2
Table of Contents 3
Sample Summary 4
Sample Data 5
MWS.7 5
MWS.8 6
MWS.9 7
MWS.10 8
MWS.11 9
MWS.12 10
MWS.13 11
MWS.14 12
MWS.15 13
MWS.16 14
MWS.17 15
QC Summary Data 16
QC - Wet Chemistry by 9050A/2510B 16
QC - Nonhalogenated Organics by EPA 8015D - GRO 17
QC - Nonhalogenated Organics by EPA 8015D - DRO/ORO 18
QC - Soil Paste (SP) Leaching Procedure 19
Definitions and Notes 20
Chain of Custody etc. 21
Page 3 of 25
Client Sample ID SampledMatrix Received ContainerLab Sample ID
Sample Summary
Project Name:
Project Number:
Project Manager:
Reported:
Montezuma Well Service
PO Box 540 08103-0002
Melvin Capitan
Recapture Disposal
07/07/21 10:02Montezuma UT, 84534
MWS.7 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-01A
MWS.8 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-02A
MWS.9 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-03A
MWS.10 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-04A
MWS.11 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-05A
MWS.12 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-06A
MWS.13 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-07A
MWS.14 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-08A
MWS.15 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-09A
MWS.16 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-10A
MWS.17 06/27/21 06/28/21 Glass Jar, 4 oz.SoilE106069-11A
[TOC_1] Sample Summary [
envirotech Inc.Page 4 of 25
1594 West North Temple, Suite 1210 x PO Box 145801 x Salt Lake City, UT 84114-5801 x Telephone (801) 538-5340 x www.ogm.utah.gov
State of Utah
SPENCER J. COX
Governor
DEIDRE M. HENDERSON
Lieutenant Governor
NOTICE OF VIOLATION
UTAH OIL AND GAS CONSERVATION ACT
TO THE FOLLOWING OPERATOR: Emailed WR
(PDLOHG'DWH
'DWHRI0DLOLQJ
&HUWLILHG0DLO
Compliance Deadline:
Under the authority of the Utah Oil and Gas Conservation Act, Section 40-6 et. Seq., Utah Code Annotated,
1953, as amended, the undersigned authorized representative of the Division of Oil, Gas and Mining (Division)
has conducted an inspection of the described site and/or records on the date listed below and has found alleged
violation(s) of the act, rules or permit conditions as described below.
Description of Violations:
Rule Reference(s)/Violation(s):
Department of Natural Resources
Division of Oil, Gas and Mining
JOEL FERRY
Executive Director
0,&.7+20$6
Division Director
7KH6WDWHZLOOSXUVXHSHQDOWLHVDFFRUGLQJO\SHU5XOH5ZKLFKDOORZVWKH
'LYLVLRQWRDVVHVVDSHQDOW\DJDLQVWDSHUVRQRUSHUVRQVQRWWRH[FHHGSHU
GD\SHUYLRODWLRQZLWKDPD[LPXPRISHUYLRODWLRQSHUSHUVRQ
:HOOVRU)DFLOLW\LQ9LRODWLRQOLVWHGRQQH[WSDJH
Melvin Capitan
Montezuma Well Services Inc.
PO Box 540
Montezuma Creek, Utah 84534
mc47654@gmail.com
10/23/2024
10/07/2027
7015 0640 0003 5275 9550
11/8/2024
Violation 1: Failure to report production water in the leak detection within 24 hours.
(R649-9-11-1)
Violation 2: Production water in the leak detection. (R649-9-11-4)
Violation 3: Berm around the land farm not in compliance. (R649-9-11-3.2)
Class I Rule R649-9. Waste Management and Disposal
Class I Rule R649-9. Waste Management and Disposal
Class I Rule R649-9. Waste Management and Disposal
5HTXLUHG$FWLRQV
3DJHRI
$GPLQLVWUDWLYHSHQDOWLHVPD\EHDVVHVVHGIRUXQDEDWHGYLRODWLRQVLVVXHGXQGHUWKHDXWKRULW\SURYLGHGLQ8WDK&RGH
$QQDQG8WDK$GPLQ&RGH56HHDWWDFKHG$GPLQLVWUDWLYH3HQDOW\6FKHGXOH
7KLVQRWLFHVKDOOUHPDLQLQHIIHFWXQWLOLWLVPRGLILHGWHUPLQDWHGRUYDFDWHGE\DZULWWHQQRWLFHRIDQ
Well or )DFLOLW\1DPH API #RU)DFLOLW\Date of Inspection
DXWKRUL]HGUHSUHVHQWDWLYHRIWKHGLUHFWRURIWKH'LYLVLRQRI2LO*DVDQG0LQLQJ)DLOXUHWRFRPSO\ZLWKWKLV
QRWLFHZLOOUHVXOWLQWKH'LYLVLRQSXUVXLQJIXUWKHUDFWLRQVDJDLQVWVDLGRSHUDWRU)XUWKHUDFWLRQVPD\LQFOXGH
LQLWLDWLRQRIDJHQF\DFWLRQVWRRUGHUIXOOFRVWERQGLQJDQGSOXJJLQJDQGDEDQGRQPHQWRIZHOOVDQGUHTXHVWVIRU
ERQGIRUIHLWXUHDGPLQLVWUDWLYHSHQDOWLHVDQGFLYLOSHQDOWLHV
<RXKDYHWKHULJKWWRUHTXHVWDFRPSOLDQFHFRQIHUHQFHZLWKDQDXWKRUL]HGUHSUHVHQWDWLYHZLWKWKH
'LYLVLRQWRUHYLHZWKHFRPSOLDQFHVWDWXVRIDQ\FRQGLWLRQRUSUDFWLFHDWDQ\RSHUDWLRQXQGHU8WDK$GPLQLVWUDWLYH
&RGH5
&RPSOLDQFH'HDGOLQH
/LVWRI:HOOVRU)DFLOLW\LQ9LRODWLRQ
Violation 1: Must report all water in leak detection within 24 hours, to the division.
Violation 2: No water shall be put into pond until the pond liner is repaired and no water is present
in the leak detection.
Violation 3: Repair berm.
Montezuma Well Services, Inc. must apply for a temporary permit with WMRC within 30 days of
issuance of this NOV and submit a plan of action for all repairs.
Orlan J. Wallace Digitally signed by Orlan J.
Wallace
Date: 2024.10.04 10:57:02 -06'00'11/8/2024
Permitting Manager (435)722-7589
cc:Compliance File SITLA
Well / Facility File Andrew Haynes, AG's Office
Bart Kettle, Deputy Director
Joshua Payne, Compliance Mgr
Patricia Everett, Compliance Specialist
Recapture Brine Disposal 220 7/9/2024
Montezuma Well Services Inc.9/4/2024
3DJHRI
"ENJOJTUSBUJWF1FOBMUZ4DIFEVMF
31FOBMUZ4DIFEVMF
5IF EJWJTJPOhT QFOBMUZ TDIFEVMF FTUBCMJTIFT B EBJMZ QFOBMUZ CBTFE PO UIF
DMBTTJGJDBUJPOPGUIFSVMFWJPMBUJPO
$MBTT*
**
PS***BTQSPWJEFEJO4VCTFDUJPO
BOE
BOEUIFEFHSFFPGBDUVBMPSUISFBUFOFEBEWFSTFJNQBDUSFTVMUJOHGSPNUIF
WJPMBUJPO
NJOPSPSNBKPSBTQSPWJEFEJO4VCTFDUJPOT
BOE
5"#-&%BJMZ1FOBMUZ4DIFEVMF
7JPMBUJPO $MBTT* $MBTT** $MBTT***
%FHSFF
.JOPS
.BKPS
5IF%JWJTJPONBZJNQPTFBENJOJTUSBUJWFQFOBMUJFTOPUUPFYDFFE
QFSEBZGPSFBDIEBZPG
WJPMBUJPO
"ENJOJTUSBUJWFQFOBMUJFTBDDSVFGSPNUIFEBUFPGUIF/07VOUJMBCBUFE
OPUUPFYDFFE
QFSWJPMBUJPOQFSQFSTPO
3%FHSFFPGBDUVBMPSUISFBUFOFEBEWFSTFJNQBDU
%FHSFF PG BDUVBM PS UISFBUFOFE BEWFSTF JNQBDU " NJOPS WJPMBUJPO BOE
BTTPDJBUFE QFOBMUZ BNPVOU NBZ CF JODSFBTFE UP B NBKPS WJPMBUJPO BOE QFOBMUZ
BNPVOUCBTFEPOUIFEFHSFFPGBDUVBMPSUISFBUFOFEBEWFSTFJNQBDUUPQVCMJDIFBMUI
TBGFUZBOEXFMGBSF
PSSFTPVSDFEFUSJNFOUSFTVMUJOHGSPNUIFWJPMBUJPO5IFEJWJTJPO
TIBMMEFUFSNJOFUIFEFHSFFPGBDUVBMPSUISFBUFOFEBEWFSTFJNQBDUUPQVCMJDIFBMUI
TBGFUZ
BOEXFMGBSF
PSSFTPVSDFEFUSJNFOU
CBTFEPOUIFUPUBMJUZPGDJSDVNTUBODFTJO
FBDIDBTFUIBUNBZJOWPMWFJODSFBTJOHB$MBTT*WJPMBUJPOUPB$MBTT**PS$MBTT***
WJPMBUJPO
PSJODSFBTJOHB$MBTT**WJPMBUJPOUPB$MBTT***WJPMBUJPO
Sundry Number: 98887
RECEIVED: Sep. 03, 2019