HomeMy WebLinkAboutDERR-2025-000617Utah Department of Environmental Quality - UST Release Detection
TANK OWNERSHIP
Name GREENWOOD MOTOR LINES, INC. DBA R+L
CARRIERS
Address 600 GILLAM ROAD- ATTN: LEGAL
WILMINGTON, OH 45177
Contact GREENWOOD MOTOR LINES, INC. DBA R+L
CARRIERS
Phone
Email JONATHAN.PARSON@RLCARRIERS.COM
TANK LOCATION
Name R+L CARRIERS - SALT LAKE CITY
Address 4375 W 1385 S
SALT LAKE CITY, UT 84104
A Operator None
Phone None
B Operator SAME
Phone SAME
Facility ID: 4002691 Inspection Date: 01/22/2025
DISPENSER DETAILS
DISP
ID/ALT
ID
SUBSTANCE UDC PIPE FLEX LOC
INSTALL
DATE
UDC
INSTALL
DATE
FIRE
VALVE
SAT
PRESENT
UDC
TEST
DISP
FLEX
CP
TEST
1 - 1 Diesel No None Jan. 1,
1910
No Yes None None
2 - 2 Diesel No None Jan. 1,
1910
No Yes None None
TANK DETAILS
Tank ID/Alt ID 1 / 1
E-Gen/AST No / Yes
Siphon/Compart No / No
Tank Status Currently In Use
Installed/Cap/Loc Jan. 1, 1910 / 12000 /
Substance
Stored Diesel / Diesel #2 (U.L.S.)
Tank Material-
Mod
Asphalt Coated or Bare Steel-
Double-Walled
ATG /
LTT Test None
LLD Test None
Pipe Material-
Mod Unknown / None
Pipe type/STP
Cont Pressurized / No
STP Flex
Connectors Not in contact with soil
LLD Model
Spill/Overfill/Sm
Delivery
Aboveground Catchment /
Overfill alarm / No
PST Fund/Other
Type Yes / None
Tank/Pipe Rel Det TankTightness
PipeLineTightness
CP Tank Test None
CP Pipe Test None
Tank ID/Alt ID 2 / 2
E-Gen/AST No / Yes
Siphon/Compart No / No
Tank Status Currently In Use
Installed/Cap/Loc Jan. 1, 1910 / 12000 /
Substance
Stored Diesel / Diesel #2 (U.L.S.)
Tank Material-
Mod
Asphalt Coated or Bare Steel-
Double-Walled
ATG /
LTT Test None
LLD Test None
Pipe Material-
Mod Unknown / None
Pipe type/STP
Cont / No
STP Flex
Connectors
LLD Model
Spill/Overfill/Sm
Delivery
Aboveground Catchment /
Overfill alarm / No
PST Fund/Other
Type Yes / None
Tank/Pipe Rel Det TankTightness
PipeLineTightness
CP Tank Test None
CP Pipe Test None
2025-01-22 Page 1 of 5
Tank ID/Alt ID 3 / 3
E-Gen/AST No / Yes
Siphon/Compart No / No
Tank Status Currently In Use
Installed/Cap/Loc Jan. 1, 1910 / 12000 /
Substance
Stored Diesel / Diesel #2 (U.L.S.)
Tank Material-
Mod
Asphalt Coated or Bare Steel-
Double-Walled
ATG /
LTT Test None
LLD Test None
Pipe Material-
Mod Unknown / None
Pipe type/STP
Cont / No
STP Flex
Connectors Steel Flex in Sump
LLD Model
Spill/Overfill/Sm
Delivery
Aboveground Catchment /
Overfill alarm / No
PST Fund/Other
Type Yes / None
Tank/Pipe Rel Det TankTightness
PipeLineTightness
CP Tank Test None
CP Pipe Test None
INSPECTION COMMENTS
None
2025-01-22 Page 2 of 5
FACILITY RESPONSES
The above accurately represents the
facility's release detection records Yes
Financial Responsibility
Financial responsibility method is ok?Yes
TANK RESPONSES
Tank 1 Pressure Piping Leak Detection
Does the pressurized piping system
have a valid annual line tightness test
or valid monthly monitoring?
Yes
Tank 2 Spill/Overfill
Tank has a spill prevention device?Yes
Are you able to visually inspect the spill
containment bucket(s) for functionality?
(i.e. are the buckets clean enough to
see cracks, etc?)
Yes
Is the spill containment bucket intact?Yes
Is the spill containment bucket(s) able
to contain a spill? (i.e. is there water,
product, debris, etc in the spill bucket
to prevent it from containing a spill?)
Yes
Does the spill bucket have a valid 3-
year test, valid monthly monitoring for
DW buckets, or the tank is exempt?
Yes
Tank 1 Spill/Overfill
Tank has a spill prevention device?Yes
Are you able to visually inspect the spill
containment bucket(s) for functionality?
(i.e. are the buckets clean enough to
see cracks, etc?)
Yes
Is the spill containment bucket intact?Yes
Is the spill containment bucket(s) able
to contain a spill? (i.e. is there water,
product, debris, etc in the spill bucket
to prevent it from containing a spill?)
Yes
Tank 1 Spill/Overfill
Does the spill bucket have a valid 3-
year test, valid monthly monitoring for
DW buckets, or the tank is exempt?
Yes
Tank 3 Spill/Overfill
Tank has a spill prevention device?Yes
Are you able to visually inspect the spill
containment bucket(s) for functionality?
(i.e. are the buckets clean enough to
see cracks, etc?)
Yes
Is the spill containment bucket intact?Yes
Is the spill containment bucket(s) able
to contain a spill? (i.e. is there water,
product, debris, etc in the spill bucket
to prevent it from containing a spill?)
Yes
Does the spill bucket have a valid 3-
year test, valid monthly monitoring for
DW buckets, or the tank is exempt?
Yes
DISPENSER RESPONSES
Dispenser 2
Fire valve is anchored properly?Yes
Does the line tightness test port on the
fire valve have the manufacturers plug
installed in it? (no ball valves)
Yes
Is the fire valve located properly below
grade?Yes
Is the fire valve's fuseable link intact?Yes
Dispenser 1
Fire valve is anchored properly?Yes
Does the line tightness test port on the
fire valve have the manufacturers plug
installed in it? (no ball valves)
Yes
Is the fire valve located properly below
grade?Yes
Is the fire valve's fuseable link intact?Yes
2025-01-22 Page 3 of 5
MONTHLY LEAK DETECTION MONITORING
Jan '24 Feb '24 Mar '24 Apr '24 May '24 Jun '24 Jul '24 Aug '24 Sep '24 Oct '24 Nov '24 Dec '24
Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl
Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl
Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl
Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl
Tank 3 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl
Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl
NON-COMPLIANCE ITEMS
All items are in compliance.
Inspection Information
Inspector:Warner, Sean
Record Created:Jan. 22, 2025, 11:16
a.m.
Inspection
Date:Jan. 22, 2025
2025-01-22 Page 4 of 5
Prepared by fueloperator.com
2025-01-22 Page 5 of 5