HomeMy WebLinkAboutDAQ-2025-0003291
DAQC-PBR033130001-25
Site ID 3313 (B1)
MEMORANDUM
TO: FILE – OVINTIV USA, INC. – Ute Tribal 8-16-4-1W
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Fred Goodrich, Environmental Scientist
DATE: January 13, 2025
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: December 12, 2024
SOURCE LOCATION: Lat:40.138176, Long: -109.995179
Duchesne County
Business Office:
Ovintiv USA, Inc.
370 17th Street, Suite 1700
Denver, CO 80202
SOURCE TYPE: Tank Battery
API: 4301350452
SOURCE CONTACTS: Ryan Zillner, Corporate Environmental Contact
Phone: 720-876-3144, Email: ryan.zillner@ovintiv.com
OPERATING STATUS: Operating.
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local
gas plant. The oil and process water in the storage tanks is
loaded into tanker trucks and hauled off-site for processing and
disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories. Federal Subpart: 40 CFR 60 Subpart OOOO.
SOURCE EVALUATION: Site Type: PBR – Uncontrolled
No Flare Controls, Site powered by Engine. The source
registered: 3199 Estimated Oil BBL.
, -
2
DOGM current 12 month rolling production is: 1,084 BBL's.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make -
Arrow (Lufkin) Model - L-795 Mfg Year - 2011 Horse Power -
65 Combustion - Natural Gas, Pneumatic, Tank
Visible Emissions
Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines
0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile
source dust 10%. [R307-201-3]
In Compliance. No excessive opacity limits were observed during evaluation.
VOC emissions are, at all times, minimized as reasonably practicable by equipment design, maintenance
and operation practices. [R307-501-4(1)]
In Compliance. Source meets uncontrolled requirements. All other internal components of tank
battery functioning as designed.
Pneumatic Controllers
All natural gas-driven pneumatic controllers are in compliance with 40CFR 60.5390 or 60.5390a as
applicable. Tagging and record keeping requirements are not required. [R307-502-4]
In Compliance. This source does not use continuous bleed controllers.
Truck loading is done by bottom filling or submerged fill pipe [R307-504(1)]
In Compliance. The truck loading valves were built and designed for submerged loading.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. All hatches were found closed at the start of the evaluation.
Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The DAQ did not identify any modifications or unauthorized equipment.
Natural Gas Engines
Engines that were installed, relocated or modified after January 1, 2016 are required to show compliance
3
with Table 1 of R307-510-4 through a performance test evaluation that is reviewed by the DAQ and
found to be in compliance. [R307-510-4(1)]
In Compliance. Meets this requirement. Pre-2016 source. Initial startup on source was 2011.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. The operator submitted for the 2020 emissions inventory.
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance. Source appears to be in order.
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance.
Records for each of the following are kept for three years:
Monthly storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if controlled.
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled. [R307-506-5]
In Compliance. Records observed at local field office and appear to be orderly and complete.
NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance. Source meets this criteria of NSPS (Part 60).
PREVIOUS ENFORCEMENT
ACTIONS: None in the past 5 years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to the site, the overall status is: In Compliance.
OGI camera was used during evaluation, no fugitive emissions
were detected. Source was clean and well kept. DAQ
recommends frequency of inspections remain current as
scheduled.
4
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ has no recommendations for the next inspector other
than what are customary.
RECOMMENDATIONS FOR NSR: None.
ATTACHMENTS: None.