Loading...
HomeMy WebLinkAboutDAQ-2025-000303,.dttFfinctur December 28,2023 Director, Air Enforcement Division CERTIFIED MAIL: 7022 0410 0002 3551 6738 Office of Civil Enforcement U.S. Environmental Protection Agency Mail Code 2242-A 1200 Pennsylvania Avenue, NW UIAH DEPARruENT OF Washington, DC 20460-0001 EI{VmONMENTAL OuALJlY AirProgramDirector. ^ ,i:-,--- o- n---:-^--^-r-r r--^+:^^ JAN 3 z[jz4Office of Enforcement, Compliance & Environmental Justice Environmental Protection Agency, Region 8 1595 Wynkoop Street Denver, CO 80202_|l2s DlvlsloN oF AIR QUALITY Executive Secretary, Utah Air Quality Board Division of Air Quality Utah Dept. of Environmental Quality 195 North 1950 West P.O. Box 144820 Salt Lake city, utah 841164820 RE: Controlled Heater and Boiler NOx Reduction Annual Progress RePort ln compliance with paragraph 46d of the Holly Refining and Marketing Company Consent Decree entered July 2,z}O8,the following is the annual progress report for Holly's program to reduce NOx emissions from controlled heaters and boilers. Crude Heater 8Hl was decommissioned as of May 28,2015. l. Controlled Heaters and Boilers for which NOx Control Technoloey was installed a. Crude Heater 8Hlb. NIIDS Feed Heatei l2Hl c. Clark Compressor I l-2 (in lieu of Reformer Heater 6H1 - See Consent Decree Appendix B, note a.)d. #5 Boiler 5l-5e. #6 Boiler 5l-6f. #8 Boiler 5l-8g. FCCU Feed Heater 4-l HF Sinclair Woods Cross Refining LLC 1070 W. 500 S, West Bountiful, UT 84087 801 -299-6600 | HFSinclair.com REVIEWEDInitials: Date: Jan 17, 2025Compliance Status: OKFile #: 10123 (B2) Director, Air Enforcement Division, et. al. December 28,2023 Page2 2. Type of NO- Control Technolog.v that was installed on each heater and boiler a. Crude Heater 8HlType: Next Generation Ultra Low-NOx Burners Manufacturer: Increase Perforrnance, Inc. Model: IPLN-SR6 Designed emission factors: 0.020 lb NOx/mmBTU corrected to 3Yo 02 on clean natural gas, natural draft b. NHDS Feed Heater 12Hl Type: Next Generation Ultra Low-NOx Burners Manufacturer: Increase Perfonnance, Inc. Model: IPLN-SRl2 Designed emission factors: 0.020 lb NOx/mrnBTU corrected to3o/o Oz on clean natural gas, natural draft c. Clark Compressor l1-2 (in lieu of Reformer Heater 6Hl) Tlpe: Replaced existing gas driven compressor with an electric driven compressorManufacturer: N/A Model: N/A Designed emission factors: Eliminated 100% of the emissions from the prior gas drive. d. #5 Boiler 5l-5Type: Selective Catalytic Reduction Manufacturer: Nationwide Boiler Inc. Model: SCR-61 Package Designed emission factors: 0.020 lb NOx/mrnBTU corrected to 3o/o Oz e. #6 Boiler 5l-6Type: Decommissioned Boiler Manufacturer: N/AModel: N/A Designed emission factors: Eliminated 100% of the emissions. f. #8 Boiler 5l-8Tlpe: Selective Catalytic Reduction Manufacturer: Nationwide Boiler lnc. Model: SCR-80 Package Designed emission factors: 0.020 lb Nox/mrnBTU corrected to 3%o oz Director, Air Enforcement Division, et. al. December 28,2023 Page 3 FCCU Feed Heater 4-1 Type: Manufacturer: Model: Designed emission factors: N/A N/A N/A Fuel gas limit to 40 mmBTulhr or less by physical restriction. ob. 3. Performance Test Results Results of the performance tests on 8Hl and 12Hl were attached to the previous annual report dated December 15, 2008. Results of the perforrnance test on #5 Boiler were attached to the previous annual report dated December 22,2010. Results of the perfonnance test on #8 Boiler were attached to the previous armual report dated December 3 1 , 20 I 3. No test is needed for the electric drive on the replacement for the Clark Compressor ll-2, the decommissioning of the CO Boiler, or the restriction on the FCCU Feed Heater. 4. Heaters and boilers scheduled to have NOx Control Technology installed next calendar year None. 5. Proposed and established permit limits applicable to each heater or boiler for which NO- Control Technolosy has been installed Permit limits forNOx from 8Hl and l2Hl were proposed by Holly at a level of 0.l0lbs/mmBtu. The established NOx perrnit limits for 8Hl and 12H1 incorporated into UDEQ permit DAQE- AN0l0l230O27-09 are 0.10 lbs/mmBtu. The permit limit for NOx from #5 Boiler was proposed by Holly at a level of 0.03 lbs/mmBtu. The established NOx permit limit for #5 Boiler incorporated into UDEQ permit DAeE-AN0101230036-10 is 0.03 lbs/mmBtu. The permit limit for NOx from #5 Boiler was proposed by Holly at a level of 0.02 lbs/mmBtu. The established NOx permit limit for #8 Boiler incorporated into UDEQ permit DAQE-ANO 1 0 I 23004 I - I 3 is 0.02 lbs/mmBtu. Sincerely, AnU{/- lov ursrvr Srm,rnonds Vice President & Refinery Manager Dustin Simmonds Director, Air Enforcement Division, et. al. December 28,2023 Page4 cc: Director, Air Enforcement Division R. Bagherian Office of Civil Enforcement Environmental Fi1e2.6.3.1.046 c/o Matrix New World Engineering Inc. . 26 Columbia Turnpike, 2d Floor Florham Park, NJ 07932 Megan J. Houdeshel Dorsey & Whitney LLP 111 S. Main Street, Suite 2100 salt l^ake city, uf 84lll-2176 ec: csullivan@matrixneworld.com foley.patrick@epa. gov gallagher.bob @W ^ail.epa. gov T. Go -UTAH DEPARTUENT OF EI.IVIRONMETITAL OI,AITTY JAN 3 Z0Z4 DIVISION OF AIR QUALITY REVIEWEDInitials: Date: Jan 17, 2025Compliance Status: OKFile #: 10123 (B2)