HomeMy WebLinkAboutDERR-2025-000449PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 1/10/2024 7-Eleven Air Quality Report P.O. Box 711 Dallas, TX 75221 Test Date: 1/9/2024 Order Number: 2364001 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #38870, MKT 2811 W 4000 S State ID 1200663 ROY, UT 84067 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-ELEVEN #38870, MKT Name :TANKNOLOGY INC. Address :2811 W 4000 S State ID 1200663 ROY, UT 84067 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :385-305-3253 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :12 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) RUL RUL 19782 11783 7999 10:32 2.00 1.98 1.96 1.94 1.92 1.90 1.88 Pass PUL PUL 7901 3807 4094 10:41 2.00 1.97 1.95 1.93 1.91 1.88 1.78 Pass Total 27683 15590 12093 All Comments: Tester :David Mathie Test Date :1/9/2024 Signature :Work Order :2364001 WO: 2364001 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 20 0.0424 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.08 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -3.88 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 6 0.0127 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.62 Pass Neg Leak Rate (CFH)0.21 19 0.0403 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.91 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 18 0.0382 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 2.14 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -4.04 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 5 0.0106 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.68 Pass Neg Leak Rate (CFH)0.21 17 0.0360 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -7.93 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0233 Total -ve LR: 0.0763 Test Date 1/9/2024 Technician Name David Mathie WO #2364001 Facility Name / Loc #7-ELEVEN #38870, MKT 38870 Street 2811 W 4000 S State ID 1200663 City, St, Zip ROY, UT 84067 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2364001 Site ID / Name:38870 / 7-ELEVEN #38870, MKT Address:2811 W 4000 S State ID 1200663 City:ROY State:UT Zip:84067