Loading...
HomeMy WebLinkAboutDERR-2025-000445PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 7/20/2022 7-Eleven Air Quality Report P.O. Box 711 Dallas, TX 75221 Test Date: 7/19/2022 Order Number: 2356076 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-Eleven 38442 200 S 1000 West State ID 3000540 Syracuse, UT 84075 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-Eleven 38442 Name :TANKNOLOGY INC. Address :200 S 1000 West State ID 3000540 Syracuse, UT 84075 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :385-320-4199 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :12 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK1 RUL RUL 19782 6384 13398 10:33 2.00 1.99 1.98 1.97 1.96 1.96 1.93 Pass TNK2 PUL PUL 7901 2995 4906 10:40 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Pass Total 27683 9379 18304 All Comments: Tester :David Mathie Test Date :7/19/2022 Signature :Work Order :2356076 WO: 2356076 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 2.12 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -5.04 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 10 0.0212 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.60 Pass Neg Leak Rate (CFH)0.21 60 0.1272 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.72 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 2.15 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -5.08 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 10 0.0212 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.66 Pass Neg Leak Rate (CFH)0.21 60 0.1272 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.75 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0424 Total -ve LR: 0.2544 Test Date 7/19/2022 Technician Name David Mathie WO #2356076 Facility Name / Loc #7-Eleven 38442 38442 Street 200 S 1000 West State ID 3000540 City, St, Zip Syracuse, UT 84075 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2356076 Site ID / Name:38442 / 7-Eleven 38442 Address:200 S 1000 West State ID 3000540 City:Syracuse State:UT Zip:84075