HomeMy WebLinkAboutDERR-2025-000326PV VENT CAP
STAGE 1 PD
STAGE I SURVEY
11000 N. MoPac Expressway, Suite 500
Austin, Texas 78759
Phone: (512) 451-6334
Fax: (512) 459-1459 Date Printed and Mailed: 4/19/2022
7-Eleven Air Quality Report
P.O. Box 711
Dallas, TX 75221
Test Date: 4/18/2022
Order Number: 2355470
Dear Regulator,
Enclosed are the results of recent testing performed at the following facility:
7-ELEVEN 41643
4184 E Pony Express Pkwy
Eagle Mountain, UT 84005
Testing performed:
Sincerely,
Dawn Kohlmeyer
Manager, Field Reporting
2 inch Pressure Decay Test
TP201.3
Store Information Testing Company
Site Name :7-ELEVEN 41643 Name :TANKNOLOGY INC.
Address :4184 E Pony Express Pkwy
Eagle Mountain, UT 84005
Address :11000 N. MoPac Expressway Suite 500
Austin, TX 78759
Phone :-Phone :(800) 800-4633
Stage I System?DUAL
Stage II System?NONE
Total # of Nozzles :10
Products per Nozzle :3
Tanks Manifolded ?No
Drop-Out tank present?NO
Total # of Tanks Tested :2
Tank Information :
Product Grade :
Tank Capacity, gallons :
Gasoline, gallons :
Ullage, gallons :
Testing Information :
Start Time :
Initial Pressure, wcg :
Pressure @ 1 minute(s) :
Pressure @ 2 minutes :
Pressure @ 3 minutes :
Pressure @ 4 minutes :
Pressure @ 5 minutes :
Allowable Final Pressure :
Pass/Fail (Enter "GF" Gross Failure)
RUL
RUL
19782
8231
11551
10:29
2.00
2.00
2.00
1.99
1.99
1.98
1.91
Pass
PUL
PREMIUM
7901
3556
4345
09:22
2.00
1.99
1.98
1.97
1.96
1.95
1.78
Pass
Total
27683
11787
15896
All
Comments:
Tester :David Mathie Test Date :4/18/2022
Signature :Work Order :2355470
WO: 2355470
PVVC tested ==>RUL Manifolded
Final Test Result (Pass / Fail) ==>Pass
PVVC Manuf. ==>OPW Model Number ==>623V-2203
Is this Original or
Replacement?
Original
If this cap is being
replaced, check here:
Manf Spec
(CFH)
Measured
Leak Rate
in ml/Min;
Cracking
(in H2O)
Calc CFH
(ml/min
x
.00212)
Result
(Pass /Fail)
Pos Leak Rate(CFH)0.05 15 0.0318 Pass
Low High Measured
Pos Cracking (in H2O)2.50 6.00 3.32 Pass
Neg Leak Rate (CFH)0.21 60 0.1272 Pass
Low High Measured
Neg Cracking (in H2O)-10.00 -6.00 -8.38 Pass
PVVC tested ==>PUL Manifolded
Final Test Result (Pass / Fail) ==>Pass
PVVC Manuf. ==>OPW Model Number ==>623V-2203
Is this Original or
Replacement?
Original
If this cap is being
replaced, check here:
Manf Spec
(CFH)
Measured
Leak Rate
in ml/Min;
Cracking
(in H2O)
Calc CFH
(ml/min
x
.00212)
Result
(Pass /Fail)
Pos Leak Rate(CFH)0.05 15 0.0318 Pass
Low High Measured
Pos Cracking (in H2O)2.50 6.00 3.36 Pass
Neg Leak Rate (CFH)0.21 60 0.1272 Pass
Low High Measured
Neg Cracking (in H2O)-10.00 -6.00 -8.41 Pass
PVVC tested ==> Manifolded
Final Test Result (Pass / Fail) ==>
PVVC Manuf. ==>Model Number ==>
Is this Original or
Replacement?
Manf Spec
(CFH)
Measured
Leak Rate
in ml/Min;
Cracking
(in H2O)
Calc CFH
(ml/min
x
.00212)
Result
(Pass /Fail)
Pos Leak Rate(CFH)
Low High Measured
Pos Cracking (in H2O)
Neg Leak Rate (CFH)
Low High Measured
Neg Cracking (in H2O)
PVVC tested ==> Manifolded
Final Test Result (Pass / Fail) ==>
PVVC Manuf. ==>Model Number ==>
Is this Original or
Replacement?
Manf Spec
(CFH)
Measured
Leak Rate
in ml/Min;
Cracking
(in H2O)
Calc CFH
(ml/min
x
.00212)
Result
(Pass /Fail)
Pos Leak Rate(CFH)
Low High Measured
Pos Cracking (in H2O)
Neg Leak Rate (CFH)
Low High Measured
Neg Cracking (in H2O)
PVVC tested ==> Manifolded
Final Test Result (Pass / Fail) ==>
PVVC Manuf. ==>Model Number ==>
Is this Original or
Replacement?
Manf Spec
(CFH)
Measured
Leak Rate
in ml/Min;
Cracking
(in H2O)
Calc CFH
(ml/min
x
.00212)
Result
(Pass /Fail)
Pos Leak Rate(CFH)
Low High Measured
Pos Cracking (in H2O)
Neg Leak Rate (CFH)
Low High Measured
Neg Cracking (in H2O)
PVVC tested ==> Manifolded
Final Test Result (Pass / Fail) ==>
PVVC Manuf. ==>Model Number ==>
Is this Original or
Replacement?
Manf Spec
(CFH)
Measured
Leak Rate
in ml/Min;
Cracking
(in H2O)
Calc CFH
(ml/min
x
.00212)
Result
(Pass /Fail)
Pos Leak Rate(CFH)
Low High Measured
Pos Cracking (in H2O)
Neg Leak Rate (CFH)
Low High Measured
Neg Cracking (in H2O)
11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759
(800) 800-4633
QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form
Rev C 1/27/2011
Site Overall Test Results: Pass
Total +ve LR: 0.0636
Total -ve LR: 0.2544
Test Date 4/18/2022
Technician Name David Mathie
WO #2355470
Facility Name / Loc #7-ELEVEN 41643 41643
Street 4184 E Pony Express Pkwy
City, St, Zip Eagle Mountain, UT 84005
Pressure Vacuum Vent Cap Test Form TP-201.1E
Stage I Vapor System Survey
Survey to determine compliance with Requirements of Title 40 Part 63 National Emission Standards for Hazardous Air Pollutants for Source Categories
Survey Date 4/18/2022 Work Order 2355470
Cust Name / Location Number 7-ELEVEN 41643
Street Address 4184 E Pony Express Pkwy
City, State, ZipCode Eagle Mountain UT 84005
Product
Stage I Type
Drop Tubes Type
Drop Tubes Max inches from tank Bottom
Fill Adapters Type
Vapor Adapters Type
NESHAP Work Required?
Vent Caps
Type
Labeled Positive Cracking Pressure
Labeled Negative Cracking Pressure
RUL
RUL
Dual Point
Straight w/ Flapper
5.00
Swivel
Swivel (poppet)
No
RUL
Pressure Vacuum cap
3
8
PUL
PREMIUM
Dual Point
Straight w/ Flapper
5.00
Swivel
Swivel (poppet)
No
PUL
Pressure Vacuum cap
3
8
Describe Work Required
Surveyed by Signature
Site Diagram
(This site diagram is for reference only and is not drawn to scale)
Work Order:2355470
Site ID / Name:41643 / 7-ELEVEN 41643
Address:4184 E Pony Express Pkwy
City:Eagle Mountain State:UT Zip:84005
W.O.# NW1-2355470 Cust Ref#: 2756456
LD C9