Loading...
HomeMy WebLinkAboutDERR-2025-000317PV VENT CAP STAGE 1 PD 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 3/10/2022 7-Eleven Air Quality Report P.O. Box 711 Dallas, TX 75221 Test Date: 3/8/2022 Order Number: 2354376 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-Eleven 36336 47 S 850 E Lehi, UT 84043 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting 2 inch Pressure Decay Test TP201.3 Store Information Testing Company Site Name :7-Eleven 36336 Name :TANKNOLOGY INC. Address :47 S 850 E Lehi, UT 84043 Address :11000 N. MoPac Expressway Suite 500 Austin, TX 78759 Phone :801-768-0539 Phone :(800) 800-4633 Stage I System?DUAL Stage II System?NONE Total # of Nozzles :8 Products per Nozzle :3 Tanks Manifolded ?No Drop-Out tank present?NO Total # of Tanks Tested :2 Tank Information : Product Grade : Tank Capacity, gallons : Gasoline, gallons : Ullage, gallons : Testing Information : Start Time : Initial Pressure, wcg : Pressure @ 1 minute(s) : Pressure @ 2 minutes : Pressure @ 3 minutes : Pressure @ 4 minutes : Pressure @ 5 minutes : Allowable Final Pressure : Pass/Fail (Enter "GF" Gross Failure) TNK1 RUL 11627 9440 2187 10:20 2.00 1.99 1.98 1.97 1.96 1.95 1.59 Pass TNK2 PUL 7829 4177 3652 10:29 2.00 1.99 1.98 1.97 1.96 1.95 1.74 Pass Total 19456 13617 5839 All Comments: Tester :David Mathie Test Date :3/8/2022 Signature :Work Order :2354376 WO: 2354376 PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 2.06 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -5.10 Fail PVVC tested ==>RUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 10 0.0212 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.41 Pass Neg Leak Rate (CFH)0.21 60 0.1272 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.38 Pass PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Fail PVVC Manuf. ==>OPW Model Number ==>623V-2203 Is this Original or Replacement? Original If this cap is being replaced, check here: Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 25 0.0530 Fail Low High Measured Pos Cracking (in H2O)2.50 6.00 2.03 Fail Neg Leak Rate (CFH)0.21 100 0.2120 Fail Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -5.06 Fail PVVC tested ==>PUL Manifolded Final Test Result (Pass / Fail) ==>Pass PVVC Manuf. ==>OPW Model Number ==>723V Is this Original or Replacement? Replacement Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH)0.05 10 0.0212 Pass Low High Measured Pos Cracking (in H2O)2.50 6.00 3.36 Pass Neg Leak Rate (CFH)0.21 60 0.1272 Pass Low High Measured Neg Cracking (in H2O)-10.00 -6.00 -8.32 Pass PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) PVVC tested ==> Manifolded Final Test Result (Pass / Fail) ==> PVVC Manuf. ==>Model Number ==> Is this Original or Replacement? Manf Spec (CFH) Measured Leak Rate in ml/Min; Cracking (in H2O) Calc CFH (ml/min x .00212) Result (Pass /Fail) Pos Leak Rate(CFH) Low High Measured Pos Cracking (in H2O) Neg Leak Rate (CFH) Low High Measured Neg Cracking (in H2O) 11000 N. MOPAC EXPRESSWAY, SUITE 500, AUSTIN, TX 78759 (800) 800-4633 QP-08-03-FF-02 Pressure Vacuum Vent Cap TP-201.1E Field Form Rev C 1/27/2011 Site Overall Test Results: Pass Total +ve LR: 0.0424 Total -ve LR: 0.2544 Test Date 3/8/2022 Technician Name David Mathie WO #2354376 Facility Name / Loc #7-Eleven 36336 36336 Street 47 S 850 E City, St, Zip Lehi, UT 84043 Pressure Vacuum Vent Cap Test Form TP-201.1E Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2354376 Site ID / Name:36336 / 7-Eleven 36336 Address:47 S 850 E City:Lehi State:UT Zip:84043 W.O.# NW1-2354376 LD C9