Loading...
HomeMy WebLinkAboutDAQ-2025-000091,.tttF$nctor January 3,2023 Mr. Bryce Bird Division of Air Quality Utah Department of Environmental Quality 195 North 1950 West Salt Lake City, UT 84115 I,TAH DEPARTMENT OF ETWHONMENTAL OI'AUTY JAN - I 2023 DIVISION OF AIR QUALITY Certified Mail: 7019 1120 0000 0079 9758 Notification of lnaccessible Valves and Monitoring Plan R307-326-9 Leaks from Petroleum Refinery Equipment Dear Mr. Bird: ln accordance with R307-326-9(3XaXvii), attached is a list of the 340 valves at HF Sinclair Woods Cross Refining LLC - Woods Cross Refinery that are considered inaccessible. Valves are considered inaccessible if the valve is in a location that cannot normally be reached, but can be accessed with a man lift or scaffolding. These valves are scheduled for annual monitoring during the period July L,2023 through December 3L,2023 in accordance with our leak detection and repair program. lf you have any questions or need additional information, please contact me at (801) 299-6645. Environmenta I Specia list Attachment cc: E. Benson (rl File 2.2.2 HollyFrontier Woods Cross Refining LLC 1070 W. 500 S, West Bountiful, UT 84087 801 -299-6600 | HFSinclair.com REVIEWEDInitials: Date: Jan 8, 2025Compliance Status: OK File #: 10123 (B2) DIFFICUTT MONITORVALVE UST REVIEWEDInitials: Date: Jan 8, 2025Compliance Status: OK File #: 10123 (B2) Unlt 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 04-FCCU 05-REFORM 06-REFORM 05-REFORM OS.REFORM 06-REFORM 06-REFORM 06-REFORM O6-REFORM 05-REFORM 06-REFORM 06-REFORM 06-REFORM 06-REFORM 06-REFORM 06-REFORM OS.REFORM 06-REFORM 05-REFORM 05-REFORM 06-REFORM 06-REFORM 06-REFORM 05-REFORM OS.REFORM O6-REFORM 06-REFORM 06-REFORM 05-REFORM 06-REFORM 05-REFORM OS.REFORM 06-REFORM 05-REFORM 05-REFORM 05-REFORM 06-REFORM 05-REFORM Tag 03620 03621 03622 03623 0352s 03626 0367L 03576 03581 03689 03592 o3707 03708 03709 03736 o3737 03738 03739 o3740 o3749 L6L72 L6L73 L6L74 16189 L795L t7952 L7953 L7954 L7955 L7956 17957 18882 18885 19s86 036804 33181 01280 OL28L oL282 01283 o7284 01285 01286 oL287 01329 01330 01331 01332 01335 01335 02436 02446 o2447 02469 02470 0247L 02472 02473 02474 02475 02476 02477 02478 02479 02480 02487 02482 02483 02484 02485 02486 02487 02488 Description I Size RV DECK SESD OF ANLYZER HS IN PIPE RACK 1.5 1.50 3OFT HI SE SIDE OF ANLZR HOUSE-2 SESD. IN PIPE RACK O.25 3OFT HISE SIDE OF ANLZR HOUSE-2. IN PIPE RACK O.5O 3OFT HI SE SIDE OF ANLZR HOUSE-2. IN PIPE RACK 0.75 3OFT HI E SIDE OF ANLZR HOUSE-2. IN P]PE RACK 3.OO 3OFT HI E SIDE OF ANLZR HOUSE-2. IN PIPE RACK 3.OO 25FT HI NW SIDE OI 4-C.4. DEETH ABS TOWER. IN PIPE RACK 1.OO 22FT HI ABOVE 4-E-LL. CMP GAS COOLER O.5O 22FT HI IN PIPE RACK ABOVE 4-E-29. DEETH ABS REBLR 2.OO 21FT HI IN PIPE RACK W SIDE OF 4-E-29. DEETH ABS REBLR 1.50 21FT HI IN PIPE RACK W SIDE OF 4-E-29. DEETH ABS REBLR 4.OO 2OFT HI W SIDE OF 4-V-4,IN PIPE RACK L2.OO 2OFT HI W SIDE OF 4-V-4. IN PIPE RACK 4.OO 2OFT HIW SIDE OF 4-V-4. IN PIPE RACK 4.OO 3OFT HISW SIDE OF 4.11.3 CMB AIR HEATER 2.OO 4-LL-3 CMB ArR HTR BLD ON LN TORISER SWSD 0/30 4.00 3OFT HI SW SIDE OF 4-11-3 CMB AIR HEATER 2.OO 35FT HISW SIDE OF 4-11-3. CMB AIR HEATER 0.75 35FT HISW SIDE OF 4-11.3. CMB AIR HEATER 0.75 3OFT HI ON FLARE LINE SOUTH SIDE OF FURNACE IN PIPE RACK 2.OO RV DECK SESD OF ANLYZER HS IN PIPE RACK RELIEF TO FLARE O.3O 3.OO 3OFT HI E SIDE OF ANLZR HOUSE.2. IN PIPE RACK O.75 3OFT HI E SIDE OF ANLZR HOUSE-2. IN PIPE RACK 3.OO 24FT HI SW SIDE OF 4.C-4. DEETH ABS TOWER 0.25 3OFT HI ON FUEL LINE SOUTH SIDE OF FURNACE IN PIPE RACK 3.OO 30 FT HI ON FG LINE S OF 4H1 PIPE RACK 3.OO 30 FT HI ON FUEL LINE SOUTH OF FURNACE PIPE RACK 3.OO 30 FT HI ON FUEL LINE SOUTH OF FURNACE PIPE RACK O.75 35 FT HI ON FUEL LINE SOUTH OF FURNACE PIPE RACK 0.75 29 FT HI ON FUEL LINE SOUTH OF FURNACE PIPE RACK O.5O 3OFT HI ON FLARE LINE SOUTH SIDE OF FURNACE IN PIPE RACK O.5O PIPE RUN S OF UNIT 4 CAUSTIC AREA BY BRIDGE FRESH SOLVENT BLK TO BLD 0.1 0.75 N/S ptpERACK OVER UN|T 4 prpERUN S SD OF RD FRESH SOLVENT BLK TO BLD 0.30 0.75 SOUR OFF GAS LN BLD IN PR ABOVE NE ANALYZER SHACK O.3O O.75 22FT HI IN PIPE RACK SE OF 4-E-11. CMP GAS COOLER 0.75 lo'swsD oF 4-v-4 FRM TOP 0.38 0.75 7-V-2O FG KO POT lN PR (FALL PROTECTION NEEDED) 3.00 rN pR TO 7-V-2O BLK 1.1 (FALL PROTECTION NEEDED) 6.00 FUEL GAS LN IN PR TO 7-V-20 BLK 1.1 IN PR N TO S 5.OO FUEI GAS LN IN PR TO 7-V.20 BLK 1.1 IN PR N TO S 5.OO FUEL GAS LN IN PR TO 6-H1 BLK 1.-1 IN PR N TO S 6.00 FG LN IN PR N TO S BLK TO 5PT629 l.l OVRRAIL O.75 FG LN IN PR N TO S BLK TO PILOT GAS 1.1 OVRRAIL 2.OO FG LN IN PR N TO S BLK TO FG LIQUID KO POT 1.1 5.OO 1.1 pR 4FT S OF 6-Es (FALL PROTECTION NEEDED) 1.00 1.2 PR 4FT S OF 6-Es (FALL PROTECTTON NEEDED) 4.00 LN FRM 11 REB TOCOOLERS BLD 1.-1PR 4FT S OF 5-E5 4.OO LN FRM 11 REB TOCOLD CHRG EX BLKTO PSV1O IN PR 4.OO LN FRM 11 REB TOCOLD CHRG EX BLKTO PSV1O IN PR 0.75 LN FRM 11 REB TOCOLD CHRG EX BLKTO PSV1O IN PR 4.OO S OF 6C-1 PREF TWR UPSTRM CNLP FV 443 0.18 XMTR urAH DEpAHTMENT oF O.75 1OFT S OF 5C_1 PREF TWR OVHD pR O.3O ENVTRONMENTAL QUAUry 5.OO 1OFT S OF 6C-1 PREF TWR OVHD PR O.3O O.75 N/S pR 3RD LVL STAB OVHD GAS VENT 0.28 W SD OF RX-3 JAN - ' 2C?? 0.7s N/S pR 2ND LVL FG LN BLK Fr42L TO 6H-3 0.20 W SD OF RX-3 o.75 N/S pR 2ND LVL FG LN BLK Fr42l rO 6H-3 0.20 W SD OF RX-3 _ 0.7s N/s pR 2ND LVL FG LN BLK Fr42tro 6H-3 o.2o w sD oF Rx-3 DlVlSloN OF AIR OUALITY o.so E/W pR 2ND LVL BLK TO PRV39 0.20 ABV 6E-16 4.00 E/W PR 2ND LVL BLK TO PRV39 0.20 ABV 6E-16 4.00 E/W pR 2ND LVL PRV39 0.20 ABV 5E-15 4.00 E/W PR 2ND LVL OUTLET BLK FRM PRV39 TO FLR HDR 0.20 6.00 N/S PR 2ND LVL BLK TO FLR HDR 0.20 ABV 6E-15 3.00 E/W PR 2ND LVL 0.20 SE OF TWR 6C-2 (FALL PROTECTION NEEDED) 6.00 E/W pR 2ND LVL 0.20 SE OF TWR 6C-2 (FALL PROTECTION NEEDED) 3.00 E/W PR 2ND LVL 0.20 SW OF TWR 6C-2 (FALL PROTECTION NEEDED) 1.00 E/W pR 2ND LVL 0.20 SW OF TWR 6C-2 (FALL PROTECTION NEEDED) 1.00 E/W PR 2ND LVL 0.2 SW OF TWR 6C.2 (FALL PROTECTION NEEDED) 1.OO E/W PR 3RD LVL LN OFF 6V-5 (FALL PROTECTION NEEDED) 0.s0 E/W pR 3RD LVL LN OFF (FALL PROTECTTON NEEDED) 0.50 E/W pR 3RD LVL LN OFF 6V-s (FALL PROTECTTON NEEDED) 0.s0 E/W pR 3RD LVL LN OFF 6V-5 (FALL PROTECTION NEEDED) 0.s0 E/W PR 3RD LVL LN OFF 5V-5 (FALL PROTECTTON NEEDED) 0.50 E/W pR 3RD LVL LN OFF 6V-5 (FALL PROTECTION NEEDED) 0.50 05-REFORM 06-REFORM 06-REFORM 05-REFORM 05-REFORM O7-ALKY O7-ALKY OT.ALKY 07-ALKY O7-ALKY O7-ALKY O7-ALKY O7-ALKY O7-ALKY O7-ALKY O7-ALKY O7-ALKY 07-ALKY 07-ALKY O7-ALKY 07-ALKY O7-ALKY OT.ALKY O7-ALKY O7-ALKY O7-ALKY 07-ALKY 07-ALKY 07-ALKY 07-ALKY O7-ALKY 07-ALKY O8-CRUDE O8-CRUDE O8-CRUDE O8-CRUDE O8-CRUDE OS.CRUDE O8-CRUDE O8-CRUDE O8-CRUDE O8-CRUDE 10-sDA 10-sDA 10-sDA 10-sDA 10-sDA 10-sDA 1O-SDA 1O-SDA 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 1.1-GAS PLANT 11-GAS PLANT ].1-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT t6454 25588 25648 31023 37L92 06106 05110 06111 o6Lt2 06113 06115 06118 067t3 L4483 L4484 t4485 14486 74487 74523 27448 29557 32405 32406 32682 32683 32684 064724 064728 33193 33L94 33757 33758 18645 20277 27998 28697 28807 28842 29L90 29191 292L6 292L8 o4527 o4522 04668 04669 15577 15578 78647 18548 L4798 L4799 14800 14801 L4802 14803 L4804 14805 14839 L4840 L484L L4842 74843 L4844 L4845 74846 L4849 14850 14851 r4852 14853 L4854 14855 14855 SE SD OF 6-E1OA BLD IN PR ABOVE 5-E-1OA 0.24 10 FT N OF 6-E-27 IN PR BLK FROM 6-V-22 FUEL GAS KO POT O.3O E/W pR ABOVE 6-pC-619C OFF CATWALK BELOW E SD OF FIN FAN H2 LN BLK TO BLD 1.7 LN FRM 11 REB TOCOLD CHRG EX BLKTO PSV1O IN PR LN FRM 11 REB TOCOLD CHRG EX BLDTO PSV1O IN PR 7.V-L9 ACID STRG BLK IN PR 0.21 NWSD HGH PNT BLD 7-V-34 OLEF COAL BLK IN PR 0.25 NESD 7-E-2 REGEN CLR BLK IN PR O.3O NESD ON FLR HDR 7-E-2 REGEN CLR BLK IN PR O.3O NESD ON FLR HDR 7-E-2 REGEN CLR BLK IN PR O.3O NESD ON FLR HDR 7-V.9 AUX ACID STRG SW SD CHN VLV BUT LN BLK IN PR O.2O 7-V-4 OLEF DRYER CHN VLV IN PR 0.22 NESD OF VSL 1OFT HIGH IN PIPE RACK N OF 7-V-28 7-V-T3 HF STRPPR FT449 ORF BLK 0.24 SWSD OF TWR 7-V.L3 HF STRPPR FT449 ORF BLK 0.24 SWSD OF TWR 7-V-L3 HF STRPPR FT449 BLK ON FTO.24 SWSD OF TWR 7-V-24 ALKY DPRP FT448 BLK ON FTO.22 SWSD 7-V-24 ALKY DPRP FT448 BLK ON FTO.22 SWSD 25 FT Hr WEST END OF 7-V-26. (FALL PROTECTIION REQUIRED) OVR RLNG lN PR N OF 7-V-28 TOP OF DECK OVER S RAIL BLK TO FLARE HDR FROM EXTRACTION COL2.-2 7-4L-7TO DEBUT RBLR OH TWR BYP CHN BLK 0.22 SSD NE SD 7V.6 SMALL TOP DECK PR O,3O' FT 4O7 NE SD 7V-6 SMALL TOP DECK PR O.3O' FT4O7 NE SD 7V-6 SMALL TOP DECK PR O.3O' FT4O7 NE SD 7V-6 SMALL TOP DECK PR O.3O' FT 4O7 NE SD 7V-6 SMALL TOP DECK PR O.3O' FT 4O7 7-V-26 DPRP STRP ACCU BLK ON TOP OF 10 IN LN OH 7-V-26 DPRP STRP ACCU BLK ON TOP OF 10 IN LN OH 5' NWSD OF 7-P-L4IN PR BLK TO FLR 0.35 5' NWSD OF 7-P-T4IN PR BLK TO FLR O.4O NE SD 7V-6 SMALL TOP DECK PR O.3O' NE SD 7V.6 SMALL TOP DECK PR O.3O' SW OF 8-H-2 BLK TO BLD ON FG OUTLET LN O.3O 10FT N OF CRUDE/ATMOS GAS OtL EXCH 8E-6 ABV ESD CNLP 8FV-4002 OHD PR 0.24 ABOVE N/S PR lN UNIT 8 H2 LN BLK TO BLD (ORANGE HANDLE) 2.7 over wsd rl BTWB 8P3 & 8P3A BLK ON FLR HDR O.2O LZFT E OF PMP 9P-2 1OFT W OF HI PRESSURE FLASH DRM 8V15 OHD BLK O.2O LZFT E OF PMP 9P-2 1OFT W OF HI PRESSURE FLASH DRM 8V15 OHD BLK O.2O ABV SSD OF PMP 9P-3 OHD BLK ON FLR HDR O.2O ABV SSD OF PMP 9P-2 OHD BLK ON FLR HDR O.2O 10FT N OF CRUDE/ATMOS GAS OtL EXCH 8E-6 ABV ESD CNLP 8FV-4002 OHD PR 0.24 10FT N OF CRUDE/ATMOS GAS OrL EXCH 8E-6 ABV ESD CNLP 8FV-4002 OHD PR 0.24 70E-6A{B/C DAO SOLV COND BYPASS - VNT VLV - 0.12 7OE-6A(B(C DAO SOLV COND BYPASS - VNT VLV - 0.12 1OV-4 FLASH TWR OUTLETBLK 2,8 1OV-4 FLASH TWR OUTLETBLK 2.8 FLARE LINE 15FT SOUTH OF 1O-950-OO2O O.3O PIPE RACK FLARE LINE 15FT S AND 30 FT W OF 1O-950-OO2O O.3O PIPE RACK N OF 1OV5 ASPH STRIP IN E/W PR BLK ON OUTLET LN O.3O N OF 1OV5 ASPH STRIP IN E/W PR BLK TO BLD ON OUTLET LN O.3O 2OFT HI 1OFT W OF TL.V.22 2OFT HI 1OFT W OF 7L.V-22 2OFT HI 1OFT W OF LI-V-22 2OFT HI 1OFT W OF LL-V-22 2OFT HI 1OFT W OF 7L-V-22 2OFT HI 1OFT W OF LT-V-22 2OFT HI 1OFT W OF LT-V-22 2OFT HI 1OFT W OF TL-V-22 14FT HI 6FT W OF 7L-V-22 14FT HI ATOP S END OF LL-V-22 14FT HI ATOP S END OF LL.V.22 14FT HI ATOP S END OF LL-V-22 14FT HI ATOP S END OF TL.V-22 14FT HI ATOP S END OF LL-V-22 14FT HI ATOP S END OF LI-V-22 14FT HI ATOP S END OF LL-V.22 28 FT HI W OF 1ST DECK OF 11-V-10 29FT HI W OF 1ST DECK OF 11-V-10 28FT HI W OF 1ST DECK OF 11-V-10 28FT HI W OF 1ST DECK OF 11-V-10 29FT HI W OF 1ST DECK OF 11-V-10 -]"FT HI UNDER S END OF RV DECK 2OFT W OF 11-V-10 -2FT HI UNDER S END OF RV DECK 2OFT W OF 11-V-10 -2FT HI UNDER S END OF RV DECK 2OFT W OF 11-V-10 1.00 2.00 0.75 4.00 o.75 0.75 3.00 8.00 8.00 8.00 2.OO 3.00 1.00 0.50 0.s0 0.38 0.38 0.38 4.00 4.00 3.00 0.50 50.00 0.2s 0.25 0.25 1.00 1.00 1.00 1.00 1.00 1.00 o.75 0.75 5.00 1.00 4.00 2.00 3.00 6.00 o.75 o.75 o.75 o.75 2.00 4.00 2.00 2.00 6.00 2.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 4.00 0.25 0.75 o.75 6.00 o.75 3.00 3.00 0.75 0.75 0.s0 4.00 1.00 1.00 11-GAS PLANT 11-GAS PLANT 11.GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 11-GAS PLANT 1].-GAS PLANT 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12.NHDS 12-NHDS 12.NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 12-NHDS 13-rSOM 13-tSOM 13-rSOM 13-rSOM 13-tSOM 13-rSOM 13-rSOM 13-tSOM 13-rSOM 13-tSOM 13-tSOM 13-rSOM 13-tSOM 13-rSOM 13-tSOM 13-tSOM 13-rSOM 13-tSOM 13-tSOM 13-rSOM 13-rSOM 13-rSOM 13-tSOM 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT 19-LCO/DHT L579L 16L32 16133 L6734 15135 16136 27502 33726 33727 33728 0531s 05316 05317 05318 05319 05322 0s323 05324 0532s 0s325 05327 0s328 05333 05334 0s335 25045 25046 25047 25048 27999 02528 02529 o25L4 02615 02811 02897 17658 17958 L7959 L7960 t7961 17962 77963 30692 30820 30821 31801 31802 319s3 31954 31955 31956 *o26L6 08369 08370 08371 08401 08402 08403 08404 08406 08407 09393 09543 09597 09598 09599 19289 19290 79297 23307 23308 24854 24855 sFT N OF 7L-AE.4 PIP RACK E TO W LN O.3O 25FT HIW OF 1ST DECK OF 11-V-10 25FT HI W OF 1ST DECK OF 11.V.10 26FT HI W OF 1ST DECK OF 11-V-10 26FT HI W OF 1ST DECK OF 11-V.10 25FT HI W OF 1ST DECK OF 11-V-10 14FT Hl ATOP S END OF Lt-V-22 East Ndl PLATFORM E OF LEAN OIL SURGE TANK OVR NE CORNER RAIL 20' IN PR HAS LOCK ON IT PLATFORM E OF LEAN OIL SURGE TANK OVR NE CORNER RAIL 20' IN PR PLATFORM E OF LEAN OIL SURGE TANK OVR NE CORNER RAIL 20' IN PR ABOVE H2 MANFLD E OF PSV112 DCK IN PR HGH PNT BLD ABOVE H2 MANFLD E OF PSV112 DCK IN PR BLD 0.25 ABOVE H2 MANFLD E OF PSV112 DCK IN PR BLD 0.22 12-95-50 H2 SUCTSCRUB E OF PSV-112BLDO.22 L2-T6-LO H2 RECY CMP BLD ON SUCT IN PR 0.22 12-95-50 STAB OH ACC BLK SE OF H2 CMP IN PRO.22 12-95-50 STAB OH ACC BLD SE OF H2 CMP IN PRO.22 72-4L-TO FD EFF EX INLT BLD N SD IN PR 0.25 T2-4T.7O FD EFF EX INLT SHELL SD BLD IN PR 0.25 BLK IN PR NW OF STAB REB FRM FUL GAS HDR 0.27 BLK IN PR NW OF STAB REB FRM FUL GAS HDR 0.27 FV415 OUTL HGH PNT BLD IN PR 0.22 t2-95-20 LO TEMP SEP N SD IN PR FRM FD EFF EX 72-95-20 LO TEMP SEP BLD IN PR N OF PSV DCK T2-95-2O LO TEMP SEP BLK IN PR N OF PSV DCK NE OF 12-AE-1A tN N/S PR LN BLK TO 11-PY-640 2.3 NE OF ].2-AE-1A tN N/S PR 11-PY-640 BYPASS BLK 2.5 NE OF 12-AE-1A tN N/S PR LN BLK FROM LL-PY-64O2.3 NE OF 12-AE-1A rN N/S PR LN BLK 2.3 NE OF 12-AE-1A rN N/S PR LN BLK TO BLD 2.2 18FT HI 15 FT SE OF 13-H1. NEXT TO CHECK VLV 18FT HI 15FTSW OF 13-H1. NEXTTO CHECKVLV 13C-1 FD SPLTR TWR TOP OF TWR VENT FRM O\H LN 7.7 13E-2 FD SPLTR REBLR S O\H BLD O.2O 16FT Hr NE S|DE OF 13E-3A/B F\F 13-20 ON LN TO RX FD VAPRZR ESD OF F\F OH 4.9 13H-1 RX FD FRNC BLK TO BLD TOP OF PIPE FRM H-1 IN PR O.3O 13H-1 RX FD FRNC BLK ON FT.416 S OF H-1 IN PR 0.25 13H-1 RX FD FRNC BLK ON FT-416 S OF H-1 IN PR 0.25 13H.1 RX FD FRNC BLK ON FT-4L6 S OF H-l IN PR E VLV 0.25 13H-1 RX FD FRNC BLK TO FT-425 S OF H-1 IN PR 0.25 13H-1 RX FD FRNC BLK TO FT-425 S OF H-1 IN PR 0.25 13H-1 RX FD FRNC BLK ON FT-425 S OF H-1 IN PR E VLV 0.25 15FT HIGH 3RD LEVELOFSTAB TWR 95.50 BLK TO BTMS EX 41-80 ESD EXT PROB NED 16FT Hr NE S|DE OF 13E-3A/B 13H-1 RX FD FRNC BLK TO BLD ON TOP OF PIPE S OF H-1 IN PR O.3O 25FT HI zOFT SE OF 13-H1 25FT HI 2OFT SW OF 13-H1 13H-1 RX FD FRNC BLK ON FT-4T6 S OF H-1 IN PR West NdIO.25 13H-1 RX FD FRNC BLK ON FT-416 S OF H-1 lN PR Top Ndl 0.25 13H-1 RX FD FRNC BLK ON FT-425 S OF H-1 lN PR Top VLV 0.25 13H-1 RX FD FRNC BLK ON FT-425 S OF H.1 IN PR WEST NDL 0.25 13E-2 FD SPLTR REBLR N O\H BLD O.2O t9-v-7 coLD sEP BLD ON TOP SSD OF VSSL 1/13 L9-V-7 COLD SEP TOP SG COL BLK ON TOP 1/13 t9-v-7 coLD sEp ToP sG coL BLD ON TOP 1/15 19V16 RECYC H2 SUCT DRM TOP BLK TO EDUCT O.2O 19V16 RECYC H2 SUCT DRM TOP PT613 BLK OH O.2O 19V16 RECYC H2 SUCT DRM TOP PT613 BLD OH O.2O 19V16 RECYC H2 SUCT DRM TOP PT613 OH O.2O 19V16 RECYC H2 SUCT DRM TOP OUTLT PSI BLK O.2O 19V15 RECYC H2 SUCT DRM TOP VNT 20 FT HIATOP 19-V-33 KO DRUM BLK TO FUEL GAS HDR SESD OF 19H1IN PR O/30 BLD ON FLR HDR SE OF RV DCK IN PR 1.3 BLK ON FLR HDR S OF RV DCK BY COMPRESSOR HOUSE IN PR 1.3 BLD ON FLR HDR S OF RV DECK BY COMPRESSOR HOUSE IN PR 1.3 N/S PR TOP BLD ON SOUR GAS LN BETWEEN UNIT 19/12 0.35 N/S PR TOP BLK ON SOUR GAS LN BETWEEN UNIT 19/12 TO NASH O.3O N/S pR CHN VLV BLK TO |NLET TO 19-E-16 SOUR GAS LN BETWEEN UNIT 19/12 0.30 15 FT SE OF RV DECK BY COMP BLDG IN PIPE RACK LN BLK FROM H2 REC 1.3 15 FT SE OF RV DECK BY COMP BLDG IN PIPE RACK BLK TO BLD FROM H2 REC LN 1.2 L9-V-7 COLD SEP SWSD SG BLK ON TOP 1.11 T9-V.7 COLD SEP SWSD SG BLK ON TOP 1.10 2.00 0.7s o.75 0.50 0.50 0.50 0.25 1.00 1.00 1.00 0.75 o.75 o.75 o.75 o.75 3.00 o.75 0.75 0.75 2.00 2.O0 0.75 o.75 0.75 2.OO 6.00 6.00 6.00 6.00 0.75 0.75 0.75 0.75 0.75 8.00 o.75 0.75 0.50 0.s0 0.2s 0.50 0.50 o.25 2.00 o.75 o.75 0.50 0.s0 0.2s 0.25 0.2s 0.25 o.75 2.00 4.00 0.75 4.00 0.75 0.50 0.50 0.75 2.00 o.75 3.00 1.00 1.00 12.00 o.75 4.00 6.00 o.75 0.75 2.00 1.50 19-LCO/DHT 2O-GHT 2O.GHT 2O-GHT 2O-GHT 2O-GHT 2O-GHT 2O-GHT 2O-GHT 2O.GHT 24.CRUDE 24-CRUDE 24-CRUDE 24-CRUDE 24-CRUDE 24-CRUDE 24-CRUDE 24-CRUDE 24-CRUDE 2s-FCCU 25-FCCU 25-FCCU 26-POLY 26-POLY 25-POLY 26-POLY 5l.BOILERS 51-BOILERS 5l.BOILERS 51-BOILERS 51-BOILERS 51-BOILERS 51-BOILERS 51-BOILERS 51-BOILERS 66.FLARE 66-FLARE 65-FLARE 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 58-WEST TK FRM 68-WEST TK FRM 68.WEST TK FRM 68-WEST TK FRM 68.WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 58-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 3L573 13808 14347 74342 74343 L4344 L4345 L4346 27787 27782 23146 26640 26750 26751 26753 26780 2678L 26782 26783 22904 229LO 229tL 23023 23078 23099 23100 0s827 0s828 05829 0s830 05831 0s832 05833 05834 05835 24846 24847 24848 0s570 05622 0s623 05624 05625 05626 05627 05628 0s629 05654 05663 05664 05677 05684 0s589 05690 0s691 06000 06801 06803 06891 09878 09879 09885 09886 09898 09899 09900 09922 10094 13189 13190 14499 14500 14501 L7L79 SESD COMP BLD RV DK TO FLR HDR BLD 1.4 15FT HI 1OFT N OF 2O.V-4. 24FT HI E SD OF 2O-V-18 IN PIPE RACK 25FT HI E SD OF 2O.V-18 IN PIPE RACK 24FT HI E SD OF 2O-V-18 IN PIPE RACK 24FT HI E SD OF 2O-V-18 IN PIPE RACK 24FT HI E SD OF 2O-V.18 IN PIPE RACK 24FT HI E SD OF 2O-V-18 IN PIPE RACK 2O-V-73 N SD 5.6 EXT POLE FROM WSD 2O-V-13 NESD 7.-3 EXT POLE 24-V-LO 7FT NW FUEL GAS LN BLD 0.28 24-E-TT 8FT N HEAVY SLOP LN BLD 0.25 24-P-6S 12FT N HEAVY SLOP HDR 0.22 24-P-6512FT NE HEAVY SLOP HDR BLD 0.21 24-P.651OFT NE LIGHT SLOP HDR BLD 0.18 24-V-TO 1OFT N CRUDE LN S BLD 0.32 24-V-LO 1OFT N CRUDE LN N BLD 0,32 24.V-TO 15FT NW CRUDE LN S BLD O.3O 24-V-LO 15FT NW CRUDE LN N BLD O.3O 25-V-14 WSD 1.-1 25-V-7412FTN S 1.6 25-V-1.412FTN NBLK1.6 26-AE-1A ABV WSD from RV DK FLARE LN From 26V5 2.2O 25-V-10 NSD 3.-2 26-V-615FT NE FLR HDR BLD 0.33 26-V-615FT NE FLR HDR 0.32 PR OH 51-35-30 FG FLTR PSV378 FLR BLK 0.35 PR OH 51-35-30 FG FLTR PSV378 BYP BLK 0.35 PR OH 51-35-30 FG FLTR PSV378 FLR BLK 0.35 PR OH 51-35.30 FG FLTR PSV378 FLR BLD 0.35 PR OH 51-35-30 FG FLTR PSV378 0.35 PR OH 51-35.30 FG FLTR PSV378 BLD 0.35 PR OH 51-35-30 FG FLTR PSV378 BLK 0.35 PR OH 51-35-20 FG FLTR PSV373 FLR BLK 0.35 PR OH 51-35-20 FG FLTR PSV373 0.35 40FT S OF S. FLR KO DRUM N/S PR 65-P-1A DSCH LN 0.25 40FT S OF S. FLR KO DRUM N/S PR 66-P-1A DSCH LN 0.30 39FTS OF S. FLR KO DRUM N/S PR 66-P-1A DSCH LN O.3O TK 141 W SD TOP OF LG TOP BLK-COL 0\25 TK 141 E SD 10 FT N OF TK E LN BLD-V O\20 TK 141 E SD 10 FT N OF TK E MID LN BLD-V O\20 TK 141 E SD 10 FT N OF TK MID LN BLD-V O\20 TK 141 E SD 10 FT N OF TK W MID LN BLD-V O\20 TK 141 E SD 10 FT N OF TK W LN BLD-V O\20 TK 141W SD 5 FT N OF TK E LN BLD-V O\20 TK 141 W SD 5 FT N OF TK W LN BLD-V O\20 TK 141 W SD 15 FT N OF TK N LN BLD-V O\20 TK 136 DECK ON TOP OF TK FLR LN BLD-V 1\5 TKL22 DECK ON TOP OF TK 5 FT N OF TK VCON 1\6 TKt22 DECK ON TOP OF TK 5 FT N OF TK BLK 1\6 TK 134 DECK ON TOP OF TK BLK-BFLG 1U TK 134 DECK ON TOP OF TK FLR LN BLD-V 1U TK 133 DECK ON TOP OF TK BLK-BLD 1U TK 133 DECK ON TOP OF TK BLK-PT 1U TK 133 DECK ON TOP OF TK BLD-N 1\2 TK123 W END TOP TK123 W END TOP TK123 W END TOP TK136 W END TOP VNT TK153 E END TOP PSV32O TK153 E END TOP PSV3zO TK153 E END TOP PSV32O TK153 E END TOP PSV32O TK324 E ENDTOP TK324 E ENDTOP TK324 E END TOP TK149 E END TOP FLR LN TK159 LN TO TK141 OH BLD From SW side deck, WEST END OF TANK 122 1FT HIGH ON TOP OF WEST END OF TANK 122 BLK TO 68PT6L22 TK 141 W SD 5 FT N OF TK E LN BLD-V O\20 TK 141 W SD 5 FT N OF TK E LN BLD.V O\20 rK147 E END TOP FLR LN BLEED TK123 W END TOP o.75 0.50 4.00 4.00 4.00 0.75 o.75 o.75 o.75 o.75 o.75 o.75 2.00 0.75 0.75 o.75 o.75 o.75 0.75 3.00 0.50 0.50 0.75 2.00 1.00 2.00 3.00 1.50 3.00 o.75 3.00 o.75 1.50 o.75 0.75 2.00 3.00 3.00 2.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.00 1.00 2.00 2.00 0.50 0.50 0.50 2.00 2.OO 2.00 o.75 0.75 2.00 2.OO 1.00 1.00 2.00 0.75 0.s0 o.75 1.00 1.00 0.s0 o.75 REVIEWEDInitials: Date: Jan 8, 2025Compliance Status: OK File #: 10123 (B2) 58-WEST TK FRM 68-WEST TK FRM 68.WESTTK FRM 68-WEST TK FRM 68-WEST TK FRM 58.WEST TK FRM 68-WESTTK FRM 68-WEST TK FRM 68-WESTTK FRM 68-WEST TK FRM 58-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 68-WEST TK FRM 58-WEST TK FRM 58-WESTTK FRM 58-WESTTK FRM 68-WEST TK FRM 58.WEST TK FRM 68-WEST TK FRM 58-WEST TK FRM 68-WESTTK FRM 68-WEST TK FRM 58-WEST TK FRM 68-WEST TK FRM 68-WESTTK FRM 58-WEST TK FRM 68-WEST TK FRM 58-WEST TK FRM 86-CRUDE UNL 86-CRUDE UNL 86-CRUDE UNL 86-CRUDE UNL 86-CRUDE UNL 85-CRUDE UNL 86-CRUDE UNL 86-CRUDE UNL 85-CRUDE UNL 86-CRUDE UNL 85-CRUDE UNL 86-CRUDE UNL 86-CRUDE UNL 85-CRUDE UNL 86.CRUDE UNL 86-CRUDE UNL 1-7L80 L7r8l L7L82 L7663 L7664 L957L 20429 20430 20431 20432 26985 26986 26987 25988 26989 2699s 27OTL 270L2 270L3 270L4 270L5 27382 33388 9808A 981sA 98274 98374 9865A 9868A 07LgL 07203 07238 07239 18158 18159 18150 18151 L8t62 18153 18164 18165 18451 18464 18465 18456 TK123 W END TOP BLK TO TEMP TK123 W END TOP BLK TO TEMP TK123 W END TOP BLK TO TANK O.3O 1FT ON TOP OF WEST END OF TANK 122. BLK TO 68PT6T22 1FT ON TOP OF WEST END OF TANK 122. BLK TO BLD 30 FT W OF COOLTNG TOWER 7 lN N/S PR BLK TO BLACK WAX 0.30 S OF 90 DAY CONTAIN TOP OF PR FLARE GAS LN BLK TO BLD O.3O SW OF COOLING TOWER 7 IN PR TOP OF FLARE HEADER BLK TO BLD 0.35 SW OF COOLING TOWER 7 IN PR BTM OF FLARE HEADER BLK TO BLD 0.32 sw oF coolrNG TowER 7 rN PR BLK TO FLARE HEADER (ORANGE HANDLE) 0.35 PR W OF 58P148A BLK TO 68FT4O2O ON FC4O2O MIN FLOW LN O.2O PR W OF 68P148A LFT BLK TO 68FT4O2O ON FC4O2O MIN FLOW LN 0.19 PR W OF 68P148A CNTER BLK TO 68FT4O2O ON FC4O2O MIN FLOW LN 0.19 PR W OF 58P148A RIGHT BLK TO 68FT4O2O ON FC4O2O MIN FLOW LN 0.19 PR W OF 68P148A BLK TO 68FT4O2O ON FC4O2O MIN FLOW LN O.2O BETWEN 68PL44 & 68P145 PR BLK TO BLD ON 58P148 LN 0.18 Over W SD OF MCC 197 PR BLK TO FT4O23 N VLVE 0.15 Over W SD OF MCC 197 PR BLK TO FT4O23 CENTR VLVE 0.15 Over W SD OF MCC 197 PR BLK TO FT4O23 S VLVE 0.15 Over W SD OF MCC 197 PR BLK TO FT4023 N VLVE 0.16 W SD Over OF MCC 197 PR BLK TO FT4O23 S VLVE 0.16 E OF TK 171 BELOW NW CORNER OF DECK PROPANE FLARE LN BLK TO BLD 2.-8 TK151 E END BTM OH PI BLK 0.15 TKL47 E END BTM OH PI BLK TK148 E END BTM OH Pl BLK TK149 E END BTM OH PI BLK TK15O E END BTM OH PI BLK TK152 E END BTM OH PI BLK TK153 E END BTM OH PI BLK 86P36 NGL UNLD PMP FLR LN BLD.V O/25 86PV5O9 VPR RECOVERY OH BLD-V PIPE RACK B/W C AND D NGL LN BLD-V O/25 PIPE RACKB/W D AND E NGL LN BLD-V O/25 N S PR INBETWN NEW & OLD TRUCK UNLOAD BLK TO BLD ON U BEND TO OULET O.3O W SD OF BAY A PR BLK TO BLD BEHIND MCCU ON BLACK WAX LN 0.25 W SD OF BAY A PR BLK TO INLET BEHIND MCCU ON BLACK WAX LN 0.25 W SD OF BAY A PR BLK TO BLD ON BYPASS ON BLACK WAX LN O.3O W SD OF BAY A PR BLK TO BYPASS ON BLACK WAX LN O.3O W SD OF BAY A PR BLK TO BLD ON BYPASS ON BLACK WAX LN O.3O w sD oF BAY A PR E/W BLK TO BYPASS ON BLACK WAX LN 0.24 W SD OF MCCU BLK TO BLD ON BLACK WAX/ WTER LN O.3O TNBETWEEN BAY B & C rN E/W PR BLK TO BLD ON U BEND ON OUTLET LN 0.30 BAY D E/W PR BLK TO BLD ON BLCK WAX WTER LN 0.25 BAy E E/ W PR BLK TO BLD ON BLCK WAX WTER LN 0.25 INBETWN BAY E & F E/ W PR BLK TO BLD ON BLCK WAX WTER LN 0.25 0.25 0.25 2.00 2.00 2.00 6.00 0.75 o.75 0.75 4.00 0.7s 0.25 0.25 0.2s 0.75 0.75 0.2s 0.25 0.2s 0.75 o.75 o.75 o.75 1.00 1.00 1.00 1.00 0.75 o.75 0.50 o.75 0.75 o.75 0.75 o.75 8.00 o.75 8.00 o.75 8.00 0.75 o.75 2.00 2.00 2.00 ri Drvrs;oN;il- "r# REVIEWEDInitials: Date: Jan 8, 2025Compliance Status: OK File #: 10123 (B2)