HomeMy WebLinkAboutDAQ-2025-000046Yr.*sms_g.s"r
Huntington Power Plant
8 miles west of Huntington, Utah on Hwy. jl
P.O. Box 680
Huntington, Utah 84528
October 31,2024
Mr. Bryce Bird, Director
Utah Department of Environmental Quality
Division of Air Quality
195 North 1950 West
P.O. Box 144820
Salt Lake City, UT 84114-4820
RE: Outage Notification, Unit I, Huntington Power Plant (Title V Permit#1501001005)
Dear Mr. Bird:
As required by ll.B.1 .f.3c of the Huntington Plant Title V operating permit, the purpose of this letter is to inform you of
a maintenance outage at the Huntington Plant. Boiler Unit was taken offline at 1:11 AM on Tuesday, October 29,
2024, due to a boiler tube leak. The tube leak was repaired, and the unit was back online with the completion of start-
up parameters achieved at 8:06 AM on Thursday, October 31 ,2024.
Please see the attached Maintenance Outage Report for details.
I am authorized to make this submission on behalf of the owners and operators of the affected source or affected
units for which the submission is made. I certify under penalty of law that I have personally examined, and am familiar
with, the statements and information submitted in this document and all its attachments. Based on my inquiry of those
individuals with primary responsibility for obtaining the information, I certify that the statements and information are to
the best of my knowledge and believe true, accurate, and complete. I am aware that there are significant penalties for
submitting false statements and information, or omitting statements and information, including the possibility of fine or
imprisonment.
For further information on this outage contact Terry Guthrie, Hunter & Huntington Plant Environmental Manager,
at 435-748-6059.
D""' ///,4{
DtPAt]TMENT OF
ENVIHONMENIAL QUALTTY
NO\/ - 6 2024
DIVISION OF AIB OUAL]IY
REVIEWED
Initials JBR Date 1/8/2025
Comp Status Meets
File # 10238 Blue 2
outage with table
Enclosures: U1 Maintenance Outage Report - PacifiCorp, Huntington Plantcc: Terry Guthrie - Environmental Manager, Hunter and Huntington Plants
Scarlet Lewis - Environmental Services - NTO 210
Russ Willson - Huntington Plant Files w/enclosures
Maintenance Outage Report,
Iluntington Plant Boiler Unit #1 Short Outage -
Tube Leak Date: rcn9n024
Date Time Description
ii
"LaD812024 1l:57 PM Unit I load lowered in anticipation of the outage.Shrtt-down
begins
t0/29/2024 l:l I AM BFO Down-time
begins
t0/29/2024 l:l I AM Stopped producing electricity
t0/30/2024 8:53 PM BFI Start-up begins-
t0/3U2024 2:40 AM Started producing electricity
t013U2024 3:23 AM <l0%oheat input from fuel oil
\lo/31/2024 4:03 AM 3 coal mills in service
10131/2024 8:06 AM Stable operation (<10% heat input from oil, 3 coal mills in service, baghouse temps
>200 degrees)Start-up ends
BFO - Boiler Fire Out
BFI - Boiler Fire In
All times shown are in Mountain Standard Time.
.- I /.JJ NEPAR'TMFNT OF
r{vrnqrugqru14ugg4=qv
I)IVISION OF AIR OUALIW