Loading...
HomeMy WebLinkAboutDERR-2025-000130195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144840 • Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 • Fax (801) 359-8853 • T.D.D. (801) 536-4284 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director ERRC-130-24 August 23, 2024 Phil Schull Poindexter Properties, LLC 600 Travis Street, Suite #400 Houston, Texas 77002 RE: Technical Review Comments - Semi Service Site Characterization Report North Salt Lake, Davis County, Utah Dear Mr. Schull: The Division of Environmental Response and Remediation (DERR) has reviewed the Site Characterization Report,dated May 24, 2024, for the referenced site. The review was conducted in accordance with the requirements of the Voluntary Cleanup Program (VCP). Based on our assessment, the DERR has enclosed technical comments for your review. Please address these comments and submit a revised Site Characterization Report. Thank you for your continued participation in the VCP. If you have any questions, please contact me at (801) 536-4100. Sincerely, Leigh Anderson, Project Manager Division of Environmental Response and Remediation KLA/tt cc: Brian E. Hatch, Director, Davis County Health Department Jay Clark, Environmental Health Director, Davis County Health Department Page 2 DERR Review Comments Site Characterization Report (SCR) Comments – Semi Service VCP Site General Comments: 1. During prior discussions on the development of the Site Characterization Workplan, it was agreed that sampling for PFAS constituents would be deferred until appropriate standards and laboratory methods were established. As discussed during our recent meeting, these standards have now been established. Given the site’s proximity to a historical landfill, PFAS sampling is now requested. Please propose additional sampling to address this comment. 2. Since the Site Characterization Report (SCR) recommended further sampling to better assess the site, it would be acceptable to include the PFAS sampling requested in General Comment #1 within a single additional workplan. Please submit this revised workplan for review. 3. Groundwater sample results should be compared to Maximum Contaminant Levels (MCLs). If no MCL exists, please use the EPA Regional Screening Levels for Tap Water as a reference. 4. The designations for TB, EB, and RB samples are unclear. If these represent Trip Blank, Equipment Blank or other QA/QC samples, please clarify this in the report. 5. The Quality Assurance Project Plan (QAPP) indicated that the Sensitivity evaluation for groundwater samples would be based on comparing the Method Detection Limit to screening levels. However, the tables in the report use the Reporting Limit instead. Please revise the table to ensure consistency with the QAPP Technical Comments: 1. Page 7: Please revise the text that indicates the site is downgradient of the Old North Salt Lake Landfill. The boundaries of the former landfill are unclear, and it is uncertain whether the landfill may have extended beneath the site. 2. Figure 3: Please include numeric values for screening levels so that the results can be compared to those values. If concentrations are below detection limits, please report the detection limits. 3. Figure 4: Several analytes are reported below detection limits, but these limits are above screening levels, which could raise concerns regarding quality assurance (Sensitivity). Please propose a strategy to address this issue, particularly for potential contaminants such as PCBs and hexavalent chromium. 4. Table 5: The laboratory results include both Heptane and n-Heptane. Please revise the table to distinguish between these results.