HomeMy WebLinkAboutDAQ-2024-0069551 DAQC-PBR032660001-23 Site ID 3266 (B1) MEMORANDUM TO: FILE – OVINTIV USA, INC. – Ute Tribal 2-19-4-1 THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager FROM: Stephen Foulger, Environmental Scientist DATE: November 29, 2023 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: November 2, 2023 SOURCE LOCATION: Ute Tribal 2-19-4-1 Lat: 40.12616 Long: -110.0356 Business Office: 370 17th Street, Suite 1700 Denver, CO 80202 SOURCE TYPE: Tank Battery Duchesne County API: 4301350271 SOURCE CONTACTS: Brandon Lithgoe, Local Contact Phone: 281-847-6093, Email: brandon.lithgoe@ovintiv.com Ryan Zillner, Local Contact Phone: 720-876-3144, Email: ryan.zillner@ovintv.com OPERATING STATUS: Operating PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go through a separator where the oil and any water products are sent to storage tanks and the gas is used to power equipment on site (pump jack engine, tank heater, separator, flare, combustor, etc.) Any remaining gas is sent to a pipeline that feeds a local gas plant. The oil and process water in the storage tanks is loaded into tanker trucks and hauled off site for processing and disposal. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventory. 2 SOURCE EVALUATION: Site Type: PBR-Uncontrolled No Flare Controls Site has Line Power The source registered: 3,199 Estimated Oil BBL. DOGM current 12 month rolling production is: 2,174 Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. REGISTERED EQUIPMENT: Pneumatic controls, Tank Battery. 8 15 Oil and Gas Industry Registration Requirement 16 The source is registered with the DAQ. [R307-505-3(3)] In Compliance. This source was found properly registered with the DAQ at the time of inspection. 17 Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. This source was found properly registered with the DAQ at the time of inspection. 18 Storage Vessels 19 Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance. Thief hatches were found closed and latched at the time of inspection. 23 Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2). [R307-506-4(6)] In Compliance. The combustor was removed from this source after production dropped below required levels. 38 46 Visible Emissions 47 Visible emissions, except for unavoidable irregularities that do not exceed three minutes, are within the following opacity limits: Installations constructed on or before 4/25/1971 40% Installations constructed after 4/25/1971 20% Gasoline engines 0% Diesel engines manufactured after 1/1/1973 20% Diesel engines manufactured before 1/1/1973 40% Note: Required VOC control devices shall have no visible emissions per R307-508-3.[R307-201-3] In Compliance. No visible emissions were observed at the time of inspection. 48 55 Emission Inventory: 56 An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. This source was found properly reported in the most recent emissions inventory. 3 PREVIOUS ENFORCEMENT ACTIONS: No enforcement actions within the past five years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to: Ute Tribal 2-19-4-1: In Compliance RECOMMENDATION FOR NEXT INSPECTION: This source was found non-compliant at the time of inspection. This source has dropped below production levels and the combustor has been removed. Recommend to keep inspection frequency the same. ATTACHMENTS: