HomeMy WebLinkAboutDERR-2024-005241Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 3/11/2024 Tanknology WO#NW1-2369158 Test Purpose REQUEST Customer PO#69410059 Customer Location MURPHY OIL USA P.O. BOX 7300 EL DORADO, AR 71731 Murphy #8807 3853 West Campus View Drive West Jordan, UT 84084 Attn: BRAD WEINISCHKE Attn: (870) 875-7610 () Test / Inspection Description Item Tested Date Tested Result Overfill Protection Tank 2 Overfill 1 PREMIUM 3/11/2024 Pass Overfill Protection Tank 3 Overfill 1 Low Sulfur Diesel 3/11/2024 Fail Overfill Protection Tank 4CLEAR Overfill 1 REG - CONV(E0) 3/11/2024 Pass RP 1200 Overfill See test report for details 3/11/2024 P/F Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) Wilson, North Carolina 27893 Telephone: 252.243.0150 Web: www.emcoretail.com A1100 Overfill Prevention Valve Calculation Sheet This calculation sheet is to document the dimensions needed for proper installation and should be used only with the instructions. This sheet assumes 95% maximum fill based on NFPA30 guidelines. Length measurements are in inches. Contact the local Authority Having Jurisdiction (AHJ) to determine all regulatory requirements regarding fill capacity. TANK: Tank 2 - Overfill PREM PREMIUM Flapper Valve PRIMARY Test Date: 3/11/2024 Company:MURPHY OIL CO Site: 8807 Address:3853 West Campus View Drive ,West Jordan ,UT Overfill Valve Height Inspection 1. Tank Diameter is TD 118.38 2. Tank Capacity is TC 7901.00 3. Desired Shutoff Percentage (Note NFPA Guidelines)0.95 4. Shutoff Tank CapacityTC@ shutoff % = TC x 0.95 7505.95 5. Tank Level from Stick Chart for Shutoff Capacity (95%)106.88 6. Tank B DimensionB = TD - TL @ 95%11.50 7. Distance from top seal surface (1) to the top (inside) of the tank (2) is A 50.50 CAUTION: If tank has a manway make sure to account for the manway height. 8. Calculated Minimum Length of OPV top tube to (95% mark) on the A1100 is C See Picture. Measure C distance from the 95% line on valve and cut top tube 62.00 9. Actual Measured Length of OPV top tube to (95% mark) on the A1100 (measure)62.38 10. Result of Valve height Inspection (if Actual is >= Calculated PASS)Pass 11. Inspect the device for corrosion, damage, and confirm proper operation? P/F Pass comments: Drop Tube Tank Bottom Clearance Inspection 1. Distance from the top seal surface to the tank bottom 2. Distance from the top of drop tube to the highest point of bottom tube cut 3. Actual Maximum tube distance from tank bottom 0.00 comments: "C" 1. The sealing surface refers to the location of the OPV collar sealing point. It may be the riser pipe or the seal surface built in to some spill buckets. 2. If the tank uses a manway, be sure to use the tank top for measurement and not the top of the manway as shown in the diagram. Riser Pipe with Spill Containment Manhole Manway Style Tank WO: 2369158 Wilson, North Carolina 27893 Telephone: 252.243.0150 Web: www.emcoretail.com A1100 Overfill Prevention Valve Calculation Sheet This calculation sheet is to document the dimensions needed for proper installation and should be used only with the instructions. This sheet assumes 95% maximum fill based on NFPA30 guidelines. Length measurements are in inches. Contact the local Authority Having Jurisdiction (AHJ) to determine all regulatory requirements regarding fill capacity. TANK: Tank 3 - Overfill 3 Low Sulfur Diesel Flapper Valve PRIMARY Test Date: 3/11/2024 Company:MURPHY OIL CO Site: 8807 Address:3853 West Campus View Drive ,West Jordan ,UT Overfill Valve Height Inspection 1. Tank Diameter is TD 118.38 2. Tank Capacity is TC 10420.00 3. Desired Shutoff Percentage (Note NFPA Guidelines)0.95 4. Shutoff Tank CapacityTC@ shutoff % = TC x 0.95 9899.00 5. Tank Level from Stick Chart for Shutoff Capacity (95%)105.63 6. Tank B DimensionB = TD - TL @ 95%12.75 7. Distance from top seal surface (1) to the top (inside) of the tank (2) is A 47.88 CAUTION: If tank has a manway make sure to account for the manway height. 8. Calculated Minimum Length of OPV top tube to (95% mark) on the A1100 is C See Picture. Measure C distance from the 95% line on valve and cut top tube 60.63 9. Actual Measured Length of OPV top tube to (95% mark) on the A1100 (measure)59.63 10. Result of Valve height Inspection (if Actual is >= Calculated PASS)Fail 11. Inspect the device for corrosion, damage, and confirm proper operation? P/F Fail comments: Drop Tube Tank Bottom Clearance Inspection 1. Distance from the top seal surface to the tank bottom 2. Distance from the top of drop tube to the highest point of bottom tube cut 3. Actual Maximum tube distance from tank bottom 0.00 comments: "C" 1. The sealing surface refers to the location of the OPV collar sealing point. It may be the riser pipe or the seal surface built in to some spill buckets. 2. If the tank uses a manway, be sure to use the tank top for measurement and not the top of the manway as shown in the diagram. Riser Pipe with Spill Containment Manhole Manway Style Tank WO: 2369158 Wilson, North Carolina 27893 Telephone: 252.243.0150 Web: www.emcoretail.com A1100 Overfill Prevention Valve Calculation Sheet This calculation sheet is to document the dimensions needed for proper installation and should be used only with the instructions. This sheet assumes 95% maximum fill based on NFPA30 guidelines. Length measurements are in inches. Contact the local Authority Having Jurisdiction (AHJ) to determine all regulatory requirements regarding fill capacity. TANK: Tank 4 - Overfill 4CLEAR REG - CONV(E0) Flapper Valve PRIMARY Test Date: 3/11/2024 Company:MURPHY OIL CO Site: 8807 Address:3853 West Campus View Drive ,West Jordan ,UT Overfill Valve Height Inspection 1. Tank Diameter is TD 118.38 2. Tank Capacity is TC 7901.00 3. Desired Shutoff Percentage (Note NFPA Guidelines)0.95 4. Shutoff Tank CapacityTC@ shutoff % = TC x 0.95 7505.95 5. Tank Level from Stick Chart for Shutoff Capacity (95%)106.88 6. Tank B DimensionB = TD - TL @ 95%11.50 7. Distance from top seal surface (1) to the top (inside) of the tank (2) is A 50.75 CAUTION: If tank has a manway make sure to account for the manway height. 8. Calculated Minimum Length of OPV top tube to (95% mark) on the A1100 is C See Picture. Measure C distance from the 95% line on valve and cut top tube 62.25 9. Actual Measured Length of OPV top tube to (95% mark) on the A1100 (measure)62.63 10. Result of Valve height Inspection (if Actual is >= Calculated PASS)Pass 11. Inspect the device for corrosion, damage, and confirm proper operation? P/F Pass comments: Drop Tube Tank Bottom Clearance Inspection 1. Distance from the top seal surface to the tank bottom 2. Distance from the top of drop tube to the highest point of bottom tube cut 3. Actual Maximum tube distance from tank bottom 0.00 comments: "C" 1. The sealing surface refers to the location of the OPV collar sealing point. It may be the riser pipe or the seal surface built in to some spill buckets. 2. If the tank uses a manway, be sure to use the tank top for measurement and not the top of the manway as shown in the diagram. Riser Pipe with Spill Containment Manhole Manway Style Tank WO: 2369158 Murphy #8807 3853 West Campus View Drive West Jordan, UT 84084 8807 Tanknology, Inc. MURPHY OIL USA 870-875-7610 800-800-4633 03/11/2024 RUL 1 25431 118.375 E//WA1100 PREM 2 7901 118.375 E//WA1100 DSL 3 10420 118.375 E//WA1100 EO CLEAR 4 7901 118.375 E//WA1100 UT151 COULD NOT REMOVE RUL SIEZED IN RISER / DSL FAILED 95.5 David Mathie P.O. BOX 7300 EL DORADO, AR 71731 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2369158 Site ID / Name:8807 / Murphy #8807 Address:3853 West Campus View Drive City:West Jordan State:UT Zip:84084 W.O.# NW1-2369158 Cust Ref#: 69410059 OVF W.O.# NW1-2369158 Cust Ref#: 69410059 RUL W.O.# NW1-2369158 Cust Ref#: 69410059 W.O.# NW1-2369158 Cust Ref#: 69410059