HomeMy WebLinkAboutDERR-2024-005230TODD KING UTAH STATE FUEL NETWORK 4315 S 2700 W SALT LAKE CITY, UT 84129 RE:Request for Petroleum Storage Tank Records UTAH STATE ITS, located at 350 S 900 W, RICHFIELD Facility Identification No. 2000689 Dear TODD KING: PST operators are required to ensure that certain tests are conducted for their tank system. Dates highlighted in "Yellow" - tests are due soon. Dates highlighted in "Red" - tests are due and you are out of compliance. Tank ID/Alt ID Description LTT -------------------- LLD Spill Bucket -------------------- Overfill Tank or Flex -------------------- Pipe CP ATG -------------------- Sump 1/1 Diesel-Diesel #2 (U.L.S.)-12000 N/A N/A N/A 3/9/2024 N/A 2/9/2024 N/A N/A LTT - Line Tightness Test LLD - Line Leak Detector Overfill ±Overfill Device Tank or Flex/Pipe CP - Corrosion Tests ATG ±Automatic Tank Gauging Sump - Tank Top Sump and applicable Dispenser Sumps Please note that UDC tests are not listed, but are required on your facility's next sump test cycle starting July 1, 2023, if applicable. Also, effective immediately pressure vent valves must be tested every three years for gasoline tanks. Please submit a copy of the required tests to the DERR within 30 days of the date due. If you have any questions please call Sean Warner at 801-536-4100. 195 North 1950 West - Salt Lake City, UT Mailing Address: - P.O. Box 144840 - Salt Lake City, UT 84114-4840 Telephone (801) 536-4100 - Fax (801) 359-8853 - T.D.D. (801) 536-4414 www.deq.utah.gov Printed on 100% recycled paper March 11, 2024 State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF ENVIRONMENTAL RESPONSE AND REMEDIATION Brent H. Everett Director UST OVERFILL EQUIPMENT INSPECTION AUTOMATIC SHUTOFF DEVICE AND BALL FLOAT VALVE Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: This data sheet is for inspecting automatic shutoff devices and ball float valves. See PEI/RP 1200, Section 7 for inspection procedures. Owner: Address: City, State, Zip Code: Phone# Tester Phone# Product Grade: Tank Number: Tank Volume, gallons: Tank Diameter, inches: Overfill Prevention Device Brand: Overfill Type AUTOMATIC SHUTOFF DEVICE INSPECTION 1. Drop tube removed from tank? 2. Drop tube and float mechanisms are free of debris? 3. Float moves freely without binding and poppet moves into flow path? 4. Bypass valve in the drop tube is open and free of blockage (if present)? 5. Flapper is adjusted to shut off flow at 95% ?* A "NO" to any item in Lines 1-5 indicates a test failure. BALL FLOAT VALVE INSPECTION * * 1. Tank top fittings are vapor-tight and leak free? 2. Ball float cage free of debris? 3. Ball free of holes and cracks and moves freely in cage? 4. Vent hole in pipe open and near top of tank? 5. Ball float pipe is proper length to restrict flow at 90% capacity?*** A "NO" to any item in Lines 1-5 indicates a test failure. Test Results: * Use manufacturer's suggested proceedure for determining if automatic shutoff device will shut off flow at 95% capacity. Tester's Name: RICHFIELD DTS DATA CENTER 350 SOUTH 900 WEST RICHFIELD, UTAH 2000689 AES UTAH LICENCE # UT 0121 STATE FUEL NETWORK PO BOX 841152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 Date: 3-14-2024 DSL 1 12031 95.75 FRANKLIN AUTOMATIC YES YES YES YES Steven B. Martin Testers Signature: * * If a ball float is found to fail the inspection , another method of overfill must be used. * * * Use manufacturer's suggested procedure for determining if flow restriction device will restrict flow at 90% capacity. Comments PASS Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.19 16:36:34 -07'00' Reason: I am the author of this document RICHFIELD DATA CENTER 350 SOUTH 900 WEST RICHFIELD, UTAH 200689 APPLIED ENVIRONMENTAL SERVICES STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 3-14-2024 PIPING SMP DSL X X X X X X X X TK INTER DSL X X X X X X X X STEVEN B MARTIN APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 AESUTAH@AOL.COM Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.19 16:34:35 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. This procedure is applicable to tank level monitor stems that touch the botom of the tank when in place. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: RICHFIELD - DTS SERVICE CENTER 350 SOUTH 900 WEST RICHFIELD, UTAH 2000689 APPLIED ENVIRONMENTAL, L.C. STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 3-14-2024 1 DSL TLS-350 12031 95.75 YES YES YES YES 81 YES 2.0 YES PASS TANK MONITOR BACKUP BATTERY FUNCTIONS PROPERLY, SETUP REPORT PRINTED BOTH SUMP SENSOR AND TANK INTERSTICIAL SENSORS FUNCTION PROPERLY Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.19 16:33:09 -07'00' Reason: I am the author of this document