Loading...
HomeMy WebLinkAboutDERR-2024-005197 October 6, 2023 Project No. 23-14-101-514 Utah Department of Environmental Quality Department of Environmental Response and Remediation 195 North 1950 West P.O Box 144840 Salt Lake City, Utah 84114-4840 Attn: Ms. Eileen Brennan, DERR Project Manager Re: Release OIN Report, Flying J Travel Plaza #773, 773 E. Flying J Drive, Richfield, Utah Dear Ms. Brennan: Broadbent & Associates, Inc. (Broadbent) is pleased to present this report associated with Release OIN which occurred on August 7, 2023 at Flying J Travel Plaza #773, located at 773 E. Flying J Drive in Richfield, Utah (Site). A summary of the incident and response actions are provided below. Broadbent was notified by Pilot Travel Centers LLC (Pilot) of an August 7, 2023 incident at Flying J #773 where contractors dropped a piece of concrete on product piping. Contractors were replacing concrete and trench drains adjacent to Dispensers 13, 14, and 15. The product line was damaged near dispenser 14 when a piece of concrete was dropped and hit the product line. A spray of fuel from the pressurized line was discharged. Contractors engaged the emergency shutoff and response actions were initiated. The discharge fuel spray impacted exposed soil at the damaged product line. Volumes were estimated at approximately 2-3 gallons of diesel released. Csesco was mobilized to repair the damaged section of the product line, but appropriate parts were not available until August 8, 2023 when the repair was completed. Broadbent mobilized to Flying J #773 on August 8, 2023 to collect a soil sample in native soil beneath the damaged section of product piping. Aric Morton of Broadbent (GS-1836) collected soil sample PS-1-36” underneath the damaged section of piping. The soil sample was collected in native soil approximately 36 below grade utilizing a decontaminated hand auger. The collected sample was preserved prior to and during transportation to Pace Analytical’s sample center in West Valley City, Utah. The sample was analyzed for benzene, toluene, ethylbenzene, total xylenes, and naphthalene (BTEXN) via EPA Method 8260B. The sample was also analyzed for Diesel Range Organics (DRO) via EPA Method 8015. Laboratory analytical results are provided below. Laboratory Analytical Results ID Date Depth B T E X N DRO PS-1-36” 8/8/23 36” <0.00146 <0.0073 <0.00365 0.0188 0.0298 30.7 ISLs 0.2 9.0 5.0 142 51 500 Review of laboratory analytical results indicates that minor detections of xylenes, naphthalene, and DRO were present in the sample; however, these residual impacts are well below Utah ISLs. Soil excavation was limited to an approximate volume equal to one-half of a 55-gallon drum. Impacted soil was placed in on-site hazardous waste drums and properly disposed. Disposal documentation has not been provided as of the date of this report. Broadbent & Associates, Inc. Spill Report OIN Sandy, Utah Flying J Travel Plaza #773 October 6, 2023 Page 2 Several photographs have been attached to this report providing documentation of the area of repair. No further action appears to be warranted based on the information provided herein. Please do not hesitate to contact us directly at (801) 505-9251 if you should have questions or require additional information. Sincerely, BROADBENT & ASSOCIATES, INC. Aric Morton Principal Geologist Certified UST Consultant CC 0276 Utah Professional Geologist No. 11585804 Attachments: Pace Analytical Laboratory Report Site Photographs ec: Mr. Chip Hughes, Pilot Travel Centers LLC, 5508 Lonas Drive, Knoxville, Tennessee, 37939-0146 chip.hughes@pilottravelccenters.com Attachment A Laboratory Analytical Report ANALYTICAL REPORT August 17, 2023 Broadbent & Associates - UT Pilot Sample Delivery Group:L1644165 Samples Received:08/09/2023 Project Number:773-605-13 Description:Flying J 773 - Richfield, UT Site:23.14-101-514 Report To:Aric Morton 186 East Main Street Suite 99 Sandy, UT 84070 Entire Report Reviewed By: August 17, 2023 [Preliminary Report] Jeff Carr Project Manager Results relate only to the items tested or calibrated and are reported as rounded values. This test report shall not be reproduced, except in full, without written approval of the laboratory. Where applicable, sampling conducted by Pace Analytical National is performed per guidance provided in laboratory standard operating procedures ENV-SOP-MTJL-0067 and ENV-SOP-MTJL-0068. Where sampling conducted by the customer, results relate to the accuracy of the information provided, and as the samples are received. Pace Analytical National 12065 Lebanon Rd Mount Juliet, TN 37122 615-758-5858 800-767-5859 www.pacenational.com 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 1 of 11 August 17, 2023 Jeff Carr Project Manager ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 1 of 11 TABLE OF CONTENTS Cp: Cover Page 1 Tc: Table of Contents 2 Ss: Sample Summary 3 Cn: Case Narrative 4 Sr: Sample Results 5 PS-1-36" L1644165-01 5 Qc: Quality Control Summary 6 Total Solids by Method 2540 G-2011 6 Volatile Organic Compounds (GC/MS) by Method 8260B 7 Semi-Volatile Organic Compounds (GC) by Method 8015 8 Gl: Glossary of Terms 9 Al: Accreditations & Locations 10 Sc: Sample Chain of Custody 11 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 2 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 2 of 11 SAMPLE SUMMARY Collected by Collected date/time Received date/time PS-1-36" L1644165-01 Solid Aric Morton 08/08/23 09:30 08/09/23 08:30 Method Batch Dilution Preparation Analysis Analyst Location date/time date/time Total Solids by Method 2540 G-2011 WG2112022 1 08/11/23 08:49 08/11/23 08:57 MT Mt. Juliet, TN Volatile Organic Compounds (GC/MS) by Method 8260B WG2112591 1 08/08/23 09:30 08/12/23 23:30 DWR Mt. Juliet, TN Semi-Volatile Organic Compounds (GC) by Method 8015 WG2113453 1 08/16/23 07:31 08/16/23 14:37 KAP Mt. Juliet, TN 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 3 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 3 of 11 CASE NARRATIVE All sample aliquots were received at the correct temperature, in the proper containers, with the appropriate preservatives, and within method specified holding times, unless qualified or notated within the report. Where applicable, all MDL (LOD) and RDL (LOQ) values reported for environmental samples have been corrected for the dilution factor used in the analysis. All Method and Batch Quality Control are within established criteria except where addressed in this case narrative, a non-conformance form or properly qualified within the sample results. By my digital signature below, I affirm to the best of my knowledge, all problems/anomalies observed by the laboratory as having the potential to affect the quality of the data have been identified by the laboratory, and no information or data have been knowingly withheld that would affect the quality of the data. [Preliminary Report] Jeff Carr Project Manager 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 4 of 11 Jeff Carr Project Manager ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 4 of 11 SAMPLE RESULTS - 01 L1644165 PS-1-36" Collected date/time: 08/08/23 09:30 Total Solids by Method 2540 G-2011 Result Qualifier Dilution Analysis Batch Analyte %date / time Total Solids 83.9 1 08/11/2023 08:57 WG2112022 Volatile Organic Compounds (GC/MS) by Method 8260B Result (dry)Qualifier RDL (dry)Dilution Analysis Batch Analyte mg/kg mg/kg date / time Benzene ND 0.00146 1 08/12/2023 23:30 WG2112591 Toluene ND 0.00730 1 08/12/2023 23:30 WG2112591 Ethylbenzene ND 0.00365 1 08/12/2023 23:30 WG2112591 Xylenes, Total 0.0188 0.00949 1 08/12/2023 23:30 WG2112591 Naphthalene 0.0298 0.0183 1 08/12/2023 23:30 WG2112591 (S) Toluene-d8 106 75.0-131 08/12/2023 23:30 WG2112591 (S) 4-Bromofluorobenzene 104 67.0-138 08/12/2023 23:30 WG2112591 (S) 1,2-Dichloroethane-d4 95.3 70.0-130 08/12/2023 23:30 WG2112591 Semi-Volatile Organic Compounds (GC) by Method 8015 Result (dry)Qualifier RDL (dry)Dilution Analysis Batch Analyte mg/kg mg/kg date / time TPH (GC/FID) High Fraction 30.7 4.77 1 08/16/2023 14:37 WG2113453 (S) o-Terphenyl 33.7 18.0-148 08/16/2023 14:37 WG2113453 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 5 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 5 of 11 QUALITY CONTROL SUMMARYWG2112022 Total Solids by Method 2540 G-2011 L1644165-01 Method Blank (MB) (MB) R3959791-1 08/11/23 08:57 MB Result MB Qualifier MB MDL MB RDL Analyte %%% Total Solids 0.000 L1644164-08 Original Sample (OS) • Duplicate (DUP) (OS) L1644164-08 08/11/23 08:57 • (DUP) R3959791-3 08/11/23 08:57 Original Result DUP Result Dilution DUP RPD DUP Qualifier DUP RPD Limits Analyte %%%% Total Solids 82.0 84.5 1 3.02 10 Laboratory Control Sample (LCS) (LCS) R3959791-2 08/11/23 08:57 Spike Amount LCS Result LCS Rec.Rec. Limits LCS Qualifier Analyte %%%% Total Solids 50.0 50.0 100 85.0-115 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 6 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 6 of 11 QUALITY CONTROL SUMMARYWG2112591 Volatile Organic Compounds (GC/MS) by Method 8260B L1644165-01 Method Blank (MB) (MB) R3960246-3 08/12/23 18:52 MB Result MB Qualifier MB MDL MB RDL Analyte mg/kg mg/kg mg/kg Benzene U 0.000467 0.00100 Toluene U 0.00130 0.00500 Ethylbenzene U 0.000737 0.00250 Xylenes, Total U 0.000880 0.00650 Naphthalene U 0.00488 0.0125 (S) Toluene-d8 107 75.0-131 (S) 4-Bromofluorobenzene 106 67.0-138 (S) 1,2-Dichloroethane-d4 100 70.0-130 Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD) (LCS) R3960246-1 08/12/23 17:15 • (LCSD) R3960246-2 08/12/23 17:34 Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits Analyte mg/kg mg/kg mg/kg %%%%% Benzene 0.125 0.135 0.137 108 110 70.0-123 1.47 20 Toluene 0.125 0.144 0.135 115 108 75.0-121 6.45 20 Ethylbenzene 0.125 0.142 0.135 114 108 74.0-126 5.05 20 Xylenes, Total 0.375 0.416 0.401 111 107 72.0-127 3.67 20 Naphthalene 0.125 0.113 0.129 90.4 103 59.0-130 13.2 20 (S) Toluene-d8 109 105 75.0-131 (S) 4-Bromofluorobenzene 109 106 67.0-138 (S) 1,2-Dichloroethane-d4 107 107 70.0-130 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 7 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 7 of 11 QUALITY CONTROL SUMMARYWG2113453 Semi-Volatile Organic Compounds (GC) by Method 8015 L1644165-01 Method Blank (MB) (MB) R3961701-1 08/16/23 15:57 MB Result MB Qualifier MB MDL MB RDL Analyte mg/kg mg/kg mg/kg TPH (GC/FID) High Fraction U 0.769 4.00 (S) o-Terphenyl 66.7 18.0-148 Method Blank (MB) (MB) R3961701-5 08/16/23 15:44 MB Result MB Qualifier MB MDL MB RDL Analyte mg/kg mg/kg mg/kg TPH (GC/FID) High Fraction U 0.769 4.00 (S) o-Terphenyl 65.3 18.0-148 Laboratory Control Sample (LCS) (LCS) R3961701-4 08/16/23 21:37 Spike Amount LCS Result LCS Rec.Rec. Limits LCS Qualifier Analyte mg/kg mg/kg %% TPH (GC/FID) High Fraction 50.0 36.9 73.8 50.0-150 (S) o-Terphenyl 63.8 18.0-148 L1644012-01 Original Sample (OS) • Matrix Spike (MS) • Matrix Spike Duplicate (MSD) (OS) L1644012-01 08/16/23 16:09 • (MS) R3961701-2 08/16/23 16:22 • (MSD) R3961701-3 08/16/23 16:34 Spike Amount Original Result MS Result MSD Result MS Rec.MSD Rec.Dilution Rec. Limits MS Qualifier MSD Qualifier RPD RPD Limits Analyte mg/kg mg/kg mg/kg mg/kg %%%%% TPH (GC/FID) High Fraction 48.3 ND 29.5 31.3 56.6 60.1 1 50.0-150 5.92 20 (S) o-Terphenyl 43.8 45.5 18.0-148 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 8 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 8 of 11 GLOSSARY OF TERMS Guide to Reading and Understanding Your Laboratory Report The information below is designed to better explain the various terms used in your report of analytical results from the Laboratory. This is not intended as a comprehensive explanation, and if you have additional questions please contact your project representative. Results Disclaimer - Information that may be provided by the customer, and contained within this report, include Permit Limits, Project Name, Sample ID, Sample Matrix, Sample Preservation, Field Blanks, Field Spikes, Field Duplicates, On-Site Data, Sampling Collection Dates/Times, and Sampling Location. Results relate to the accuracy of this information provided, and as the samples are received. Abbreviations and Definitions (dry)Results are reported based on the dry weight of the sample. [this will only be present on a dry report basis for soils]. MDL Method Detection Limit. ND Not detected at the Reporting Limit (or MDL where applicable). RDL Reported Detection Limit. RDL (dry)Reported Detection Limit. Rec.Recovery. RPD Relative Percent Difference. SDG Sample Delivery Group. (S) Surrogate (Surrogate Standard) - Analytes added to every blank, sample, Laboratory Control Sample/Duplicate and Matrix Spike/Duplicate; used to evaluate analytical efficiency by measuring recovery. Surrogates are not expected to be detected in all environmental media. U Not detected at the Reporting Limit (or MDL where applicable). Analyte The name of the particular compound or analysis performed. Some Analyses and Methods will have multiple analytes reported. Dilution If the sample matrix contains an interfering material, the sample preparation volume or weight values differ from the standard, or if concentrations of analytes in the sample are higher than the highest limit of concentration that the laboratory can accurately report, the sample may be diluted for analysis. If a value different than 1 is used in this field, the result reported has already been corrected for this factor. Limits These are the target % recovery ranges or % difference value that the laboratory has historically determined as normal for the method and analyte being reported. Successful QC Sample analysis will target all analytes recovered or duplicated within these ranges. Original Sample The non-spiked sample in the prep batch used to determine the Relative Percent Difference (RPD) from a quality control sample. The Original Sample may not be included within the reported SDG. Qualifier This column provides a letter and/or number designation that corresponds to additional information concerning the result reported. If a Qualifier is present, a definition per Qualifier is provided within the Glossary and Definitions page and potentially a discussion of possible implications of the Qualifier in the Case Narrative if applicable. Result The actual analytical final result (corrected for any sample specific characteristics) reported for your sample. If there was no measurable result returned for a specific analyte, the result in this column may state “ND” (Not Detected) or “BDL” (Below Detectable Levels). The information in the results column should always be accompanied by either an MDL (Method Detection Limit) or RDL (Reporting Detection Limit) that defines the lowest value that the laboratory could detect or report for this analyte. Uncertainty (Radiochemistry)Confidence level of 2 sigma. Case Narrative (Cn) A brief discussion about the included sample results, including a discussion of any non-conformances to protocol observed either at sample receipt by the laboratory from the field or during the analytical process. If present, there will be a section in the Case Narrative to discuss the meaning of any data qualifiers used in the report. Quality Control Summary (Qc) This section of the report includes the results of the laboratory quality control analyses required by procedure or analytical methods to assist in evaluating the validity of the results reported for your samples. These analyses are not being performed on your samples typically, but on laboratory generated material. Sample Chain of Custody (Sc) This is the document created in the field when your samples were initially collected. This is used to verify the time and date of collection, the person collecting the samples, and the analyses that the laboratory is requested to perform. This chain of custody also documents all persons (excluding commercial shippers) that have had control or possession of the samples from the time of collection until delivery to the laboratory for analysis. Sample Results (Sr) This section of your report will provide the results of all testing performed on your samples. These results are provided by sample ID and are separated by the analyses performed on each sample. The header line of each analysis section for each sample will provide the name and method number for the analysis reported. Sample Summary (Ss)This section of the Analytical Report defines the specific analyses performed for each sample ID, including the dates and times of preparation and/or analysis. Qualifier Description The remainder of this page intentionally left blank, there are no qualifiers applied to this SDG. 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 9 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 9 of 11 Pace Analytical National 12065 Lebanon Rd Mount Juliet, TN 37122 Alabama 40660 Nebraska NE-OS-15-05 Alaska 17-026 Nevada TN000032021-1 Arizona AZ0612 New Hampshire 2975 Arkansas 88-0469 New Jersey–NELAP TN002 California 2932 New Mexico ¹TN00003 Colorado TN00003 New York 11742 Connecticut PH-0197 North Carolina Env375 Florida E87487 North Carolina ¹DW21704 Georgia NELAP North Carolina ³41 Georgia ¹923 North Dakota R-140 Idaho TN00003 Ohio–VAP CL0069 Illinois 200008 Oklahoma 9915 Indiana C-TN-01 Oregon TN200002 Iowa 364 Pennsylvania 68-02979 Kansas E-10277 Rhode Island LAO00356 Kentucky ¹ ⁶KY90010 South Carolina 84004002 Kentucky ²16 South Dakota n/a Louisiana AI30792 Tennessee ¹ ⁴2006 Louisiana LA018 Texas T104704245-20-18 Maine TN00003 Texas ⁵LAB0152 Maryland 324 Utah TN000032021-11 Massachusetts M-TN003 Vermont VT2006 Michigan 9958 Virginia 110033 Minnesota 047-999-395 Washington C847 Mississippi TN00003 West Virginia 233 Missouri 340 Wisconsin 998093910 Montana CERT0086 Wyoming A2LA A2LA – ISO 17025 1461.01 AIHA-LAP,LLC EMLAP 100789 A2LA – ISO 17025 ⁵1461.02 DOD 1461.01 Canada 1461.01 USDA P330-15-00234 EPA–Crypto TN00003 ACCREDITATIONS & LOCATIONS ¹ Drinking Water ² Underground Storage Tanks ³ Aquatic Toxicity ⁴ Chemical/Microbiological ⁵ Mold ⁶ Wastewater n/a Accreditation not applicable * Not all certifications held by the laboratory are applicable to the results reported in the attached report. * Accreditation is only applicable to the test methods specified on each scope of accreditation held by Pace Analytical. 1 Cp 2 Tc 3 Ss 4 Cn 5 Sr 6 Qc 7 Gl 8 Al 9 Sc ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 09:34 10 of 11 ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE: Broadbent & Associates - UT Pilot 773-605-13 L1644165 08/17/23 10:09 10 of 11 Attachment B Site Photographs Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 1, view facing SW: Site Orientation Photograph 2, view facing NW: Site Orientation Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 3, view facing SW: Area of pipe repair and location of soil sample PS-1-36” (under right boot) Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 4, view facing XXX: <<description>> Photograph 5, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 6, view facing XXX: <<description>> Photograph 7, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 8, view facing XXX: <<description>> Photograph 9, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 10, view facing XXX: <<description>> Photograph 11, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 12, view facing XXX: <<description>> Photograph 13, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 14, view facing XXX: <<description>> Photograph 15, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 16, view facing XXX: <<description>> Photograph 17, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 18, view facing XXX: <<description>> Photograph 19, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 20, view facing XXX: <<description>> Photograph 21, view facing XXX: <<description>> Broadbent & Associates, Inc. Spill OIN, FJ 773 Richfield Sandy, Utah Photographs by Broadbent Photograph 22, view facing XXX: <<description>> Photograph 23, view facing XXX: <<description>>