Loading...
HomeMy WebLinkAboutDERR-2024-005169APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 TEI 5000 NON VOLUMETRIC, TEI 4000 VOLUMETRIC, TEI ULLAGE, TEI LT3 PRECISION TANK & LINE TEST RESULTS SUMMARY INVOICE ADDRESS:TANK LOCATION: WORK ORDER # TECH # 94027 TECHNICIAN: SM STATE TECH # STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 IRON COUNTY ROAD 1105 NORTH BULLDOG ROAD CEDAR CITY, UTAH 84721 24023 UT 0121 DATE: 3-7-2024 TIME START: 10:00 TIME END: 15:00 GROUNDWATER DEPTH: N/A DW TK TANK TANK CAPACITY 11996 PRODUCT DSL TANK PASS VENT PASS PRODUCT LINE PASS LINE LEAK DETECTOR PASS WATER IN TANK 0.0" PUMP TYPE PRESS TANK MATERIAL DWF1. 2. 3. 4. 5. 6. PRODUCT LINES TESTED AT 50 PSI FOR 15 MIN LINE RATES (GPH) 1. 2. 3. 5. 6. DSL -.010 ADDITIONAL INFORMATION: CERTIFIED TECHNICIAN SIGNATURE:DATE:3-7-2024 These systems meet all requirements set forth by USEPA 40 CFR and has received third party certification. 4. TEST METHODS USED FOR THIS LOCATION TEI 5000 NON VOLUMETRIC TANK TEST TEI 4000 VOLUMETRIC TANK TEST TEI TANK ULLAGE TEST TEI LT3 LINE TESTXX X LINE LEAK DETECTOR TYPE & SIMULATED LEAK RATE 1. 2. 3. M = MECHANICAL E = ELECTRONIC # = (GPH) RATE 4. 5. 6. M 3 All tests were performed according to manufacturer protocol, and within the common practices of the industry. However due to the variables of tightness testing, these results cannot be guaranteed. There are no warranties expressed, written or implied. DEQ ID#6000090 Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.15 11:22:35 -07'00' Reason: I am the author of this document STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UT 84141-1152 (801) 619-7232 GAS STATION INSPECTION REPORT Facility ID# Facility Name and Site Address: Date: Purpose:Regular______Reinspection_____Complaints______Annual Inspection ______ Nu m b e r Te s t e d Sa t i s f i e d Re j e c t e d Ad j u s t e d Pumps tested for calibration Water tests/Fuel storage Storage tanks properly labeled Fill caps and underground storage covers-good Fuel filters on pumps Overfill prevention valve Security seals intact MOTOR FUEL PRODUCTS USED FOR INSPECTION Regular_____ gallons Unleaded Regular_____ gallons Unleaded Plus_____ gallons Unleaded Premium_____ gallons Diesel_____ gallons Product was returned to fuel storage tanks. Inspection Remarks: Received by:Inspected by:Steven B. Martin UT0121 Applied Environmental Services L.C. ACTION TAKEN IRON COUNTY ROAD DEPARTMENT 1105 NORTH BULLDOG ROAD CEDAR CITY, UTAH 3-7-2024 6000090 X 1-2 X X XX X X X X 12 Dispenser Continuity Test X IRON COUNTY ROAD DEPARTMENT 1105 NORTH BULLDOG ROAD CEDAR CITY, UTAH 6000090 STATE FUEL NETWORK APPLIED ENVIRONMENTAL SERVICES PO BOX 141152 SALT LAKE CITY, UT BRETT GURNEY 385-602-4872 801-540-9258 3-7-2024 1 DSL VAPORL 2000 X 33 32 100 2 19 2 X X X X STEVEN B MARTIN Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.15 12:01:57 -07'00' Reason: I am the author of this document IRON COUNTY ROAD DEPARTMENT 1105 NORTH BULLDOG ROAD CEDAR CITY, UTAH 6000090 APPLIED ENVIRONMENTAL SERVICES STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 3-7-2024 DISP SU DSL X X X X X X X X STP SUM DSL X X X X X X X X TK INTER DSL X X X X X X X X STEVEN B MARTIN APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 AESUTAH@AOL.COM Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.15 11:59:38 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: IRON COUNTY ROAD DEPARTMENT 1105 NORTH BULLDOG ROAD CEDAR CITY, UTAH 6000090 AES UTAH TESTER # UT 0121 STATE FUEL NETWORK PO BOX 141152 SALT LAKE CITY, UTAH 84141-1152 BRETT GURNEY 385-602-4872 801-540-9258 3-7-2024 1 DSL TLS 300C 11996 96 YES YES YES YES 81 YES 2 YES PASS BATTERY BACKUP FUNCTIONS PROPERLY SETUP REPORT PRINTED Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.03.15 11:25:51 -07'00' Reason: I am the author of this document