Loading...
HomeMy WebLinkAboutDDW-2024-014912 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144830 • Salt Lake City, UT 84114-4830 Telephone (801) 536-4200 • Fax (801) 536-4211 • T.D.D. (801) 536-4414 www.deq.utah.gov Printed on 100% recycled paper State of Utah SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF DRINKING WATER Nathan Lunstad Ph.D., P.E. Director December16, 2024 Justin Hambleton Upper Whittemore Water Co 13083 S 2730 W Riverton, Utah 84065 Dear Mr. Hambleton, Subject: RTCR Level 2 Assessment Upper Whittemore Water Co UTAH25136 I would like to thank you for taking the time to meet with me on October 4th, 2024, for a Level 2 Assessment (L2) of your water system. Your willingness to accommodate this request is greatly appreciated. Observations: This site visit was triggered by a Routine and Repeat TC+ EC- July/August 2024 distribution system samples. September 2024 systems Routine was TC+EC- With No repeats. July, August, September 2024 the system had multiple TC+ samples from 2 of its spring sources and TC+EC+ from Spring WS003. System Closed out the season with TC-EC- distribution sample and TC-EC- source assessment samples. System is in the design process of installing chlorinators at all 3 of their spring sources. Conclusions: 1. TC + Routine & Repeat samples in the distribution system are likely caused by low quality spring source water. And possibly stagnant water age, as this system is large covering a considerable amount of area with very little usage being a non-primary weekend cabin/home site. 2. TC+EC- and TC+EC+(WS003) source samples, are likely a combination of low-quality source water and possibly sampler error as these source samples have to be dipped out of the spring boxes which makes the process prone to contamination. Justin Hambleton Page 2 December 16, 2024 Recommendations: Install Chlorination as planned at all 3 spring sources. 1. Follow RTCR and Ground Water Rule with regards to Repeat sampling and Triggered source sampling following a routine TC+ sample. Contact DDW if not sure on follow up sampling. 2. Follow sanitary sampling protocol of sufficient flushing and disinfection, using a strong chlorine-based solution (applying, allowing contact time, flushing, sample collection). 3. Contact Rural Water Association of Utah for Further Technical assistance or questions on sampling procedure: Terry Smith 435-691-0691 tsmith@rwau.net Feel free to contact me at (385) 270-7272 or bpattee@utah.gov, with questions or if we can be of further assistance. If you have any questions regarding the work performed, please contact Field Services Section manager, Ryan Dearing, at rdearing@utah.gov (801) 560-8456. Sincerely, Brian Pattee Environmental Scientist III Utah Division of Drinking Water cc: Brian Pattee, Division of Drinking Water, bpattee@utah.gov Sitara Federico, Division of Drinking Water, sfederico@utah.gov Daymon Swenson, Utah County Health Department, daymons@utahcounty.gov Brent Arns, DDW Engineer, barns@utah.gov Chris Martin, DDW Engineer, cmartin@utah.gov Justin Hambleton Page 3 December 16, 2024