HomeMy WebLinkAboutDERR-2024-005118Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name Diamond C Fuels Address 2041 S MAIN ST BLANDING, UT 84511 Contact Diamond C Fuels Phone Email diamondc.mike@gmail.com TANK LOCATION Name DIAMOND C SHELL Address 215 E MAIN ST GREEN RIVER, UT 84525 A Operator MIKE V. CHRISTENSEN Phone (435) 459-4686 B Operator SAME Phone SAME Facility ID: 5000014 Inspection Date: 03/12/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 Gasoline No Booted Steel Flex None None Yes No None None 2 - 3/4 Gasoline No Booted Steel Flex None None Yes No None None TANK DETAILS Tank ID/Alt ID 4 / 4 E-Gen/AST No / No Siphon/Compart No / No Tank Status Temporarily Out of Use Installed/Cap/Loc May 7, 1998 / 10000 / South Substance Stored Gasoline / Regular Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG / LTT Test None LLD Test None Pipe Material-Mod Flexible Plastic / Double- Walled Pipe type/STP Cont Pressurized / No STP Flex Connectors Booted Steel Flex LLD Model Vaporless LD2000 Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Ball float valve / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det CP Tank Test July 11, 2022 CP Pipe Test None Tank ID/Alt ID 5 / 5 E-Gen/AST No / No Siphon/Compart No / No Tank Status Temporarily Out of Use Installed/Cap/Loc May 7, 1998 / 8000 / North Substance Stored Gasoline / Premium Tank Material- Mod Galvanic Cathodic Protection (STIP3)-None ATG / LTT Test None LLD Test None Pipe Material-Mod Flexible Plastic / Double- Walled Pipe type/STP Cont Pressurized / No STP Flex Connectors Booted Steel Flex LLD Model Red Jacket / VR FX1V Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Ball float valve / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det CP Tank Test July 11, 2022 CP Pipe Test None INSPECTION COMMENTS Title: USTs temporarily out of use CP test current. Tanks empty and locked. No annual and tri annual testing required other than CP. 2024-03-12 Page 1 of 5 Title: dispensers covered by plywood. Not accessible. Title: Owner Mike Chrstensen Want to remove USTs ASAP. 2024-03-12 Page 2 of 5 FACILITY RESPONSES Financial Responsibility Financial responsibility method is ok?Yes Operator Training A Operator current?Yes B Operator current?Yes Monthly checklist available and complete?Yes Cathodic Protection The results of the last two cathodic protection tests are available (within six months of installation and every three years thereafter)? Yes The above accurately represents the facility's release detection records Yes TANK RESPONSES Tank 4 Temporary Closure Is release detection being maintained or is the depth of product less than 1 inch? Yes What is the depth of product? (Inches)<1 The cathodic protection system being maintained?Yes The tanks are locked and secured?Yes Tank 4 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes Tank 5 Temporary Closure Is release detection being maintained or is the depth of product less than 1 inch? Yes What is the depth of product? (Inches)<1 The cathodic protection system being maintained?Yes The tanks are locked and secured?Yes Tank 5 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes Tank 4 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 4 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 5 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 5 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes DISPENSER RESPONSES 2024-03-12 Page 3 of 5 Dispenser 3/4 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 1/2 Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Mar '23 Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 5 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS All items are in compliance. 2024-03-12 Page 4 of 5 Prepared by fueloperator.com Inspection Information Inspector:Wilson, David Record Created: March 12, 2024, 11:27 a.m. Inspection Date:March 12, 2024 2024-03-12 Page 5 of 5